Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling timber scantling 40 sqcm and over in section in any position complete all as specified and directed by engineer-in-charge. |
| 2 | M&L for preparation of new steel surfaces and iron surfaces of any description over 10cm width or girth not otherwise described and applying twocoat of synthetic enamal paint over one coat of redoxide primer complete all as specified and directed by engineer-in-charge. |
| 3 | Dismantling of wall or ceiling boards (fibre,pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness including cover fillets complete all as specified and directed by engineer-in-charge. |
| 4 | Providing & fixing false ceiling with semi perforated 12mm thick micro tegular edged GRG false ceiling tilesat all heights with GRS (Glass Fiber Reinforced Gypsum) false ceiling tile of size 595X595 mm of approved texture, design and pattern having moisture content less then 2 %, humidity resistance of 99%,NRCO .50 to 0.75 as per IS 8225 :1987, Noncmbustiibleas per IS 476 (part 4)-1970 and light reflectance of 855 (minimum) to be laid in true horizontal level suspended on interlockingmetel T grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @120 gms per sqm including both side) comprising of main T runners of size 15X32 mm length 3000mm ,cross T of size 15X32 mm of length 600mm to fromgrid module of size 600mm X600mm suspended from Ceiling using galvanised mild steel items (galvanizing @ 80 gms per sqm) i e 50mm long ,8mm outer dia M-6 hanger rod upto 1000mm length and L shape level adjuster of size 85X25X2mm galvanised iron perimeter wall angle of size 24X24X0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plug at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications,drawing complete all as specified and directed by engineer-in-charge. |
| 5 | Dismantling plain or corrugated steel sheeting any gauge thickness, including nanital or similar patteren roof covering complete all as specified and directed by engineer-in-charge. |
| 6 | S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrrugations side lap, fixed with coach screws and washers, in roofs, wall etc. with grade of zinc coating 275 complete all as specified and directed by engineer-in-charge. |
| 7 | S&F 0.63mm thick galvanised, plain mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed by engineer-in-charge. |
| 8 | M&L for preparation of new steel and iron surfaces of any description over 10 Cm width or girth not otherwise described and applying two coats of synthetic enamel paint (1st base coat in single colour and 2nd coat in camoflauged pattern with atleast three colours) as approved by user and directed by Engineer-in-Chargeover a coat of moderant solution to remove zinc coating complete all as specified and directed by Engineer-in-Charge |
| 9 | Taking down cement plaster on brick wall upto any height and ceilings includingraking out joints hacking for key srcubbing down with water complete all as specified and directed by engineer-in-charge. |
| 10 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed by engineer-in-charge. |
| 11 | M&L for preparation of new plastered surfaces and applying total two coats (1st base coat in single colour and 2nd coat in camoflauged pattern with atleast three colours) of 100% premium acrylic emulsion paint having VOC less than 50gm/lit and UV resistance as perIS 15489:2004, Alkali and funggal resistance , dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre/10 sqm overcomplete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by engineer-in-charge. |
| 13 | M&L for preparation of new surface of wall and applying two coats of oil emulsion distemper over a coat of 3 mm thick wall putty complete all as specified and directed by engineer-in-charge. |
| 14 | Taking down chowkhat or frame with shutters (without taking off the shutter from the frame)not exc 1.5 sqm each complete all as specified and directed by engineer-in-charge. |
| 15 | S&F anodised aluminium powder coating minimum thickness of powder coating 50 micron frame for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and directed by engineer-in-charge. |
| 16 | S&F anodised aluminium powder coating minimum thickness of powder coating 50 micron door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber packing, anodised aluminium snap beading screws etc, complete all as specified and directed by engineer-in-charge. |
| 17 | S&F 5.5 mm thick tinted/plain glass for aluminium windows/doors having each pane exc 0.5 sqm including fittings complete all as specified and directed by engineer-in-charge. |
| 18 | S&F 100mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodisedtype C-21 complete all as specified and directed by engineer-in-charge. |
| 19 | M&L glazed ceramic colour tiles 300mmx450mm/300mm x200mm x7mm thick set and jointed in neat cement slurry and pointed in coloured cement on vertical surfaces such as skirting/dado over cement mortar rendering/screding 10mm thick 1:4 complete all as specified and directed by engineer-in-charge. |
| 20 | M&L for 20mm thick granite black slab, machine cut, well polished, bedded in 15mm thick in cement mortar 1:4 as in cooking plaforms & like and jointed with grey cement slurry and pointed with white cement(1:2) using marble dust with admixtures of pigments to match the shade of granite stone including cutting and polishing etc. complete all as specified and directed by engineer-in-charge. |
| 21 | Supply only water proofing compound complete all as specified and directed by engineer-in-charge. |
| 22 | S&F in repair single bowl sinks with drain boardmade of stainless steel 1mm thick kitchen with plugs, washers, including bedding in cement mortar or fixing cantilever bracket and connecting union to pipe, overall size 915mmX460mm bowl size 410mmX330mmX160mm complete all as specified and directed by engineer-in-charge. |
| 23 | S&FPVC connection, 60cm long, 15mm in size with PTMT nust and PVC washers at both ends complete all as specified and directed by engineer-in-charge. |
| 24 | S&F in repair swan necked brass CP Mixer for (WHB) mixing hot & cold water screwed for iron pipe acomplete all as specified and directed by engineer-in-charge. |
| 25 | S&F for pre-fabricated stainless steel plate rack made out of 1 mm thick stainless steel plate jointed with brass screws of size 600 x 750mmx 250mmcomplete all as specified and directed by engineer-in-charge. |
| 26 | S&F CP grating doom 125 mm dia with waste hole and cockroach trap fixed properly to the floor and sealed properly and finished with white cement complete all as specified and directed by engineer-in-charge. |
| 27 | Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface, work in soft disintergreted rock complete all as specified and directed by engineer-in-charge. |
| 28 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge. |
| 29 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed by engineer-in-charge. |
| 30 | M&L for surface exc not exc 30cm deep and averaging 15cm deep and getting out hard/dense soil complete all as specified and directed by engineer-in-charge. |
| 31 | M&L for hard core of broken stones of guage not exc 63mm, deposited spread and levelled in layers not exc 15cm thick watered and rammed to a true surface complete all as specified and directed by engineer-in-charge. |
| 32 | M&L for 100mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in floors, spike rolling to surfaces or making impressions of expandedmetal,whilst the concrete is green complete all as specified and directed by engineer-in-charge. |
| 33 | Providing and laying 60mm thick factory made chemfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footpath, parks, lowns, driver ways or light trafic parking etc.of required strength, thickness & size/shape, made by table vibratory method using PU mould,laid in required colour and petern over and including 50mm thick compected bed of fine sand ,compecting and proper embeding /laying of inter locking paver block into the sand bedding layer through vibratoey compection by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by engineer-in-charge. |
| 34 | S&F Fe 410-w (Gde E 250)quality A rolled mild steel in roof trusses (framed) trussed, purlins, crane gantries, rails and framing (beam, tee, angle, channel or flat sections) including distance pieaces cleats etc complete all as specified and directed by engineer-in-charge. |
| 35 | S&F MS plates plain or chequered square cut or notched forming holes drilled or welded any thickness complete all as specified and directed by engineer-in-charge. |
| 36 | Taking up or down steel tubing of 20 mm bore and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store complete with all fittings & valves etc complete all as specified and directed by engineer-in-charge. Note:- Excavation shall be measured and paid separately under relevent items. |
| 37 | Relaying only GI pipes of size 20 mm bore in trenches including thorough cleaning and descaling internally complete all as specified and directed by engineer-in-charge. Note:- GI pipe to be measured only found serviceable in all respect retrived item.). |
| 38 | M&L in replacement for layingof size 20mm dia tubes medium grade galvanized with all fittings laid in trenches complete all as specified and directed by engineer-in-charge. |
| 39 | S&F in replacement Gun metal globe or gate valve iron wheel head, screwed both ends for iron pipe of bore of 20 mm and length as required on site complete all as specified and directed by engineer-in-charge. |
| 40 | M&L in replacement for Lagging to pipe all around with 40mm thick bonded mineral wool perfomed \"SNAP ON\" pipe section of density 144kg/cum and provided with chicken mesh wire netting 25 gauge 20mm mesh on pipe of internal dia 25/20 mm includingrendering cement plastering 15mm thick (1:3) on top layer of lagging complete all as specified and directed by engineer-in-charge. |
| 41 | M&L in replacement for construction of valve pit brick masonry internal size 600x600x600mm (from top of PCC to bottom of cover ) including excavation in any type of soil returning, filling in around foundation and removal of surplus soil to a distance not exceeding 50 mtr, PCC 1:4:8 type D-2 in foundation brick work in cement mortar 1:6, 6mm thick plaster in cementmorter 1:4 to internal surface covered pit with MS sheet over 2 mm thick with locking arrangement, handle fixing arrangement and painting with aluminium paint two coats over a coat of red oxide primer complete all as specified and directed by engineer-in-charge. |
| 42 | Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e.light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1:3) or plaster of paris and to match/finish new surface as the existing surface either by using same colour distemper, putty or white/colour wash complete all as specified and directed by engineer-in-charge. |
| 43 | Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories of single/three phase complete all as specified and directed by engineer-in-charge. |
| 44 | M&L in replacement of Concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements withPVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes suitable for modular frame plate made out of MS sheet of thickness not less than 1.6 mm with earth dollyand with suitable modular frame plate ISI marked for fixing of switches / sockets, fan regulators, wall mountingfittings, door bell & bulkhead/telephone socket etcincluding PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed by engineer-in-charge. One light, fan, bell point controlled by one switch. |
| 45 | All as per item No 44 here-in-before but 5 Amp independent socket point controlled by one switch complete all as specified and directed by engineer-in-charge. |
| 46 | All as per item No 44 here-in-before but one 5 Amp socket point controlled by one switch on same board complete all as specified and directed by engineer-in-charge. |
| 47 | All as per item No 44 here-in-before but for power point wiring with 2.5 SqmmPVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by engineer-in-charge. |
| 48 | M&L in replacement of sub main wiring with two single core PVC-FRLSH insulated unsheathed multi stranded copper conductor cable of size 10.0 sqmm drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc laid in concealed position with 10.0 Sqmm PVC-FRLSH insulated unsheathed multi stranded copper conductor as a continuous earth wire including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed by engineer-in-charge. |
| 49 | All as per item No 48 above but of size 1.5 sqmm complete all as specified and directed by engineer-in-charge. |
| 50 | S&F in replacement of Modular Switch 1 way, 5/6 Amps, 1 module (ISI marked) complete all as specified and directed by engineer-in-charge. |
| 51 | S&F in replacement of modular switch 1 way, 16 Amps, 1 module (ISI marked) complete all as specified and directed by engineer-in-charge. |
| 52 | S&F in replacement of modular socket, 5/6 Amps, multi pin (ISI marked) complete all as specified and directed by engineer-in-charge. |
| 53 | S&F in replacement of modular socket, 6/16 Amps, multi pin (ISI marked) complete all as specified and directed by engineer-in-charge. |
| 54 | S&F in replacement of modular Bell push, 5/6 Amps, 1/2 module (ISI marked) complete all as specified and directed by engineer-in-charge. |
| 55 | S&F in replacement of Door bell multi music type 230V, single pole,ISI Marked complete all as specified and directed by engineer-in-charge. |
| 56 | S&F in replacement of Ceiling rose, surface backlite, 65 x 20 mm three terminal ISI Marked complete all as specified and directed by engineer-in-charge. |
| 57 | S&F in replacement of Lamp holder insulatedbody with back plate suitable for angle / batten fittingISI Marked complete all as specified and directed by engineer-in-charge. |
| 58 | S&F in replacement of sheet metal enclosure VTPN MCCB DB 4way, 415 V (vertical type) Double door with bus bar double door type IP 43 - IK 09 as per IEC 61439-3 suitable for flush mounting complete with 250 A copper bus bar for each phase with 2 neutral and 2 earth bus bars with cable ties for cable management for DB\"s when MCB & MCCB125 Amps (as incomer)to be used, fixed properly in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed by engineer-in-charge. |
| 59 | S&F in replacement ofMCCB 125 Amps, 3 Pole, 415V, 16 KA with thermal magnetic protection adjustable type with short circuit and overload protection complete all as specified and directed by engineer-in-charge. |
| 60 | S&F in replacement of Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DB of cables/wires complete all as specified and directed by engineer-in-charge. |
| 61 | S&F in replacement MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed by engineer-in-charge. |
| 62 | All as per item item No 61 avoce but SP 40 Amps complete all as specified and directed by engineer-in-charge. |
| 63 | All as per item item No 61 but SPN 16-40 Amps complete all as specified and directed by engineer-in-charge. |
| 64 | S&F in replacement ofDecorative ultra slimlinear LED lighting fixtures with extruded polycorbonate environmental friendly energy saver LEDlight fitting 1x20 watt (4\"), 230 Volts, single tube mounting including LED Tube20Watt complete with electronic driver spring loaded rotory type lamp holder, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection with three core copper cable from ceiling rose to led light fitting complete all as specified and directed by engineer-in-charge. |
| 65 | S&F in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V ACd ecorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by engineer-in-charge. |
| 66 | S&F in replacement ofLED Lamp 12 watt, 240 volts complete all as specified and directed by engineer-in-charge. |
| 67 | S&F in replacement ofrecess mounted LED panel, 36 watt ( 2\"x2\"), highly efficient suitable for celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable complete all as specified and directed by engineer-in-charge. |
| 68 | S&F in replacement of LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp with connected accessories like clamp, nut, bolt etc complete all as specified and directed by engineer-in-charge. |
| 69 | S&F in replacement ofbuilding security light fitting new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07of 35 watt LED, 240 Volts including bracket made out of GI pipe 25mm dia medium grade, 0.9 mtr long bent to shape with welded MS flat 25 x 6 mm for mounting of fitting & MS flat iron clamps made out of 25mmX 6mm thick fixed nuts, bolts complete all as specified and directed by engineer-in-charge. |
| 70 | S&F in replacement ofGyser including installation and testing ofISI marked, energy efficient, water heater storage typemade of ultra-thick super cold rolled steel plates, incoloy glass-coated heating element offering superior heating performance, electrically operated, single phase, 50 Hz (BEE 5 star rating), complete of 25 Ltr capacity suitable to withstand 8 bar pressure with whirlflow technology and adjustable knob for convenient setting of temperature with and including supply and fixing, wire armoured 450 mm long, 15 mm dia brass coupler etc, flexible pipe suitable to withstand upto 100 degree celcius for hot and cold water, anchor fastner - 04 Nos of suitable size, 3 core PVC insulated, FRLSH multistranded copper conductor cable and plug top 15 Amps capacity complete all as specified and directed by engineer-in-charge. Note : Old unserviceable geyser is to be deposited to MES store yard. |
| 71 | S&F in replacement ofheavy duty exhaust fan AC single phase 230/240 V of size 300 mm sweep 1400 RPMwith louver & shutterincluding connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and necessary grouting on wall complete and making good the wall surface after fixing of exhaust fan complete all as specified and directed by engineer-in-charge. Note : Old unserviceable Exhaust fan is to be deposited to MES store yard. |
| 72 | S&Fofexhaust fan of size 250 mm sweep made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper windingincluding connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and necessary grouting on wall complete and making good the wall surface after fixing of exhaust fan complete all as specified and directed by engineer-in-charge. Note : Old unserviceable Exhaust fan is to be deposited to MES store yard. |
| 73 | M&L Earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level) withtop edge of earth plate not less than 1.5 Mtr below normal ground level connected to earth lead wire 4 mm as earth lead by means of bolts, nuts washers and check nutsof steel/GI duly protected with 20 mm bore light grade pipe upto main board, 20mm bore watering pipe light gradewith CI/MS funnel and wire mesh including excavation , earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoaldust and common salt as all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel withwire mesh complete all as specified and directed by engineer-in-charge. |
| 74 | S&F in replacement of copper strip of size 20x3 mm complete with saddles/ insulators made out of PVC or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints complete all as specified and directed by engineer-in-charge. |
| 75 | S&F in replacement of air termination single pointed copper rod 12mm dia and 300mm long complete all as specified and directed by engineer-in-charge. |
| 76 | M&L in replacement for test point terminal block made of gun metal or phosphorus bronze of size 75X75X6mm drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head screw complete all as specified and directed by Engr-in-charge. |
| 77 | S&F in replacement of GI tubing light grade25 mm dia, cut to size and bent to shape all as required at site including fixing arrangement with necessary clamps of required size at site and providing appropriate size of insulators to pipe from foundation of air termination rod complete all as specified and directed by engineer-in-charge. |
| 78 | M&L Earthing complete with copper earth plate electrode 600x600x3.15 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level ) withtop edge of earth plate not less than 1.5 Mtr below normal ground level connected to copper Strip of size 20x3 mm as earth lead by means of bolts, nuts washers and check nutsof steel/GI duly protected with 40 mm bore light grade pipe upto main board, 20mm bore watering pipe light gradewith CI/MS funnel and wire mesh including excavation , earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoaldust and common salt after mixing with BFC (Back Fill Compound) inadeqate quantity as recommended by the manufacturer all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel withwire mesh complete all as specified and directed by engineer-in-charge. |
| 79 | Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for schedule of credit complete all as specified and directed by engineer-in-charge. |
| 80 | Supply, layingtesting and connecting 70 Sqmm 3.5 Core XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electrical cable with aluminium conductor, 1100 volts grade laid in trenches/ducts/wall or through pipe with suitable size of cable glands, crimping type cable lugs complete all as specified and directed by engineer-in-charge. |
| 81 | All as per item No 80 above but of size 50 x 3.5 sqmm complete all as specified and directed by engineer-in-charge. |
| 82 | All as per item No80 above but of size 25 x 2 sqmm complete all as specified and directed by engineer-in-charge. |
| 83 | M&L for excavation in trenches in any type of soil, not exc 1.5m wide and not exc 1.5m in depth, for foundation, laying of cables and getting out complete all as specified and directed by engineer-in-charge. |
| 84 | M&L for returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm each layer complete all as specified and directed by engineer-in-charge. |
| 85 | M&L for removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by engineer-in-charge. |
| 86 | M&L for tubing GI light grade 50 mm bore laid in trenches, ducts, floor for protection of cable,fixed to wall or poles including fixing arrangement all as required complete all as specified and directed by engineer-in-charge. |
| 87 | Supply, installation and testing and commissioning of LT cubical outdoor panel box (Feeder Pillar), IP-52 protection class, CPRI approved,floor mounted dust/vermin prooffactory fabricated , made out of MS sheet of thickness 3.15 mmmounted on angle iron legs made out of angle iron of size 40x40x6mmwith front & rear opening with locking arrangement, powder coated, CRCA sheet containing bus bar chamber to accommodate 3 phase & 1 neutral copper busbar covered with R Y B and black PVC heat shrinkable sleeve, size 40 x 10 mm mounted on hygroscopic insulators in horizontal position (stepped manner) in upper part of panel, middle part of distribution panel provided with separate chambers for 01 No. incomming MCCB, 03 Nos for outgoing MCCBs connected to copper busbar of size 20 x 5 mm in bottom partfor cable connection in distribution panel including PCC foundation of panel complete all as required at site and directed by Engr-in-charge to accomodate the following :- a) MCCB 250 Amps 4P, 25 kA, 415 volt, with S/C and O/L protection thermal magnetic release adjustable type as I/G - 01 Nos (b) MCCB 125 Amps 3P, 25 kA, 415 volt, with S/C and O/L protection thermal magnetic release adjustable type as O/G - 01 Nos, for VTPN DB 01 Nos(c) MCCB 100 Amps 3P, 25 kA, 415 volt, with S/C and O/L protection thermal magnetic release adjustable type as O/G - 02 Nos, spare for future work(d) Onload Changeover switch 200 Amps 4 pole. -01 Nos (e) Digital multi-function meter, 3 phase AC 415 volt, flush mounting 96x96 mm accuracy class 1.0, input voltage measurement range 50-520 VAC with suitable CT\"s capable of measuring V, A, F, PF, KW, KVA, kWh/kVAh, old energy, Load hours, CT secondary site selectable 1A/5A, CT/PT site programmable including all parameters - 01 No.(f) Set of LED phase indicator lamp (R,Y,B) - 01 set. Note :- All accessories pre wired with suitable size copper conductor cable and cable gland/lugs etc, proper arrangements for proper ventilation with provn of connecting earthing at both sides of panel board including making necessary arrangements for fixing all as required at site and directed by Engr-in-charge. |
| 88 | Fabrication, supply, installation and testingof LT feeder pillar box floor mounteddust/vermin proof outdoor type, powder coated of size 0.60x0.85x0.50 mtr factory fabricated, made out of MS sheet of thickness 3.15 mm mounted on angle iron legs made out of angle iron of size 40x40x6 mm within front & rear opening with locking arrangement , containing bus bar chamber to accommodate 3 phase & 1 neutral copper busbar of size 20x10mm drilled with suitables holes for fixing of cables and mounted on epoxy based insulator in horizontal position (stepped manner) in feeder pillar including necessary excavation and PCC (1:2:4) complete all as specified and directed by engineer-in-charge. |
| 89 | M&L in replacement ofLED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by engineer-in-charge. |
| 90 | M&L for pole painting of steel pole any type up to 7.5 mtr height above ground level including cross arms,clamps,stay clamps etc with two coats of aluminium paint after surface preparation complete all as specified and directed by engineer-in-charge. |
| 91 | S&F in replacement of street light pole box suitable for fixing on LT pole size 200x160x98 mm 25 sqmm terminal block 4 Nos, 4 sqmm Earth terminal 1 No with suitable gland, door and locking arrangment and suitable for terminal single phase including MCB 6-10A SP and fixing in position with nut, bolt, clamp, disconnection and reconnection of service wire/UG cabel in boxincluding dismentling old street pole box complete all as specified and directed by engineer-in-charge. |
| 92 | Supply, fix and laying of DWC pipe of size 90/75 mm dia (outer dia) with coupler including passing the LT Cables of size 70-95 sqmm through the DWC pipe for protection of cable complete all as specified and directed by engineer-in-charge. |
| 93 | Supply, fix and laying of DWC pipe of size 50/38 mm dia (outer dia) with coupler including passing the LT Cables of size 16-70 sqmm through the DWC pipe in trench/duct/on wall (with clamp) for protection of cable complete all as specified and directed by engineer-in-charge. |
| 94 | S&F in replacement of cable route indicator for LT UG Cable of 1100 Volts 50 mm dia CI Plate marked on LT cablebolted with 40 x 5 mm flat iron member of height 0.7 mtr, embedded in PCC 1:3:6 type C-2 of size 20 x 20 x 30 cm block complete all as specified and directed by engineer-in-charge. |
| 95 | M&L Earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level ) withtop edge of earth plate not less than 1.5 Mtr below normal ground level connected to GI Strip of size 25x4 mm as earth lead by means of bolts, nuts washers and check nutsof steel/GI duly protected with 40 mm bore light grade pipe upto main board , 20mm bore watering pipe light gradewith CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoaldust and common saltquantity as recommended by the manufacturer oras diirectred by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel withwire mesh complete all as specified and directed by engineer-in-charge. |
| 96 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary of capacity 2.0 TR complete all as specified and directed by engineer-in-charge. |
| 97 | S&F MCB protected socket combo box of ratting 16 Amps with sheet steel enclosuresfor AC complete all as specified and directed by engineer-in-charge. |
| 98 | M&L for sub main wiring with two single core PVC-FRLSH insulated unsheathed multi stranded copper conductor cable of size 6.0 sqmm drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc laid in concealed position with 6.0 Sqmm PVC-FRLSH insulated unsheathed multi stranded copper conductor as a continuous earth wire including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed by engineer-in-charge. |
| 99 | S&F Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed by engineer-in-charge. |
| 100 | S&F 415V 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning of size TPN 40 To 100 AMP complete all as specified and directed by engineer-in-charge. |
| 101 | M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 3.5 core complete all as specified and directed by engineer-in-charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail