| 1 | Fabricate, supply, install testing and commissioning ofLT panel indoor type 415 Volts, 50 Hz, 3 phase, 4 wire suitable foraccommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for indoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 2mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for aluminium bus bars 600 Amps capacity, hinged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specified and directed:- (a) ON Load changeover switch 4 pole 320 Amps, Incomer -1 No(b) 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA,-01 Nos(c) 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 25 KA,-01 Nos(d) 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA,-01 Nos(e) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA,-01 Nos(f)4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA,-01 Nos(g) Digital VAF Meter-01 Nos(h) CT\"s 400/5- set of 3 No(i) LED type Indication lamps (RYB)-one set (for each incoming and outgoing) Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr in Charge /GE before commencement of work. (ii) Switch gear and connected items should be of approved make. (iii) Bottom portion of panel should be 30cm above from the ground level. |
| 2 | Fabricate, supply, install, testing and commissioning of LT panel outdoor type 415 Volts, 50 Hz, 3 phase, 4 wire Suitable for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for outdoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for aluminium bus bars 400 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following accessories suitable for incoming/outgoing arrangements complete all as specifed and directed:-(a) 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 36 KA,-01 No , Incomer-1 No(b) 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA,-01 No(c) 4 Pole MCCB 100 Amp,50 Hz, 415V with rupturing capacity 25 KA- 01 No(d) 4 Pole MCCB 63 Amp,50 Hz, 415V with rupturing capacity 16 KA- 01 No(e)Multifunctional VAF meter -01 Nos (f) CT\"s 200/5- set of 3 No(g) LED type Indication lamps (RYB)-one set(for each incoming and outgoing) Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr in Charge /GE before commencement of work. (ii) Switch gear and connected items should be of approved make. (iii) Bottom portion of panel should be 30 cm above from the ground level. |
| 3 | Fabricate, supply, install, testing and commissioning of LT panel Outdoor type 415 Volts, 50 Hz, 3 phase, 4 wire for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for outdoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for aluminium bus bars 400 Amps capacity, hinged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following accessories suitable for incoming/outgoing arrangements complete all as specifed and directed:- (a) On load changeover switch 4 Pole 315 Amps, Incomer -1 No(b) 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, -1 No(c) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity16 KA, -01 No(d) 3 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 16 KA, -03 No(e) Multifunctional VAF Meter -01 No(f)Digital Ammeter-01 No(g) CT\"s 200/5- set of 3 No(h) LED type Indication lamps (RYB)-one set (For each incoming and outgoing ) Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr in Charge /GE before commencement of work. (ii) Switch gear and connected items should be of approved make. (iii) Bottom portion of panel should be 45 cm above from the ground level. |
| 4 | Fabricate, supply, install, testing and commissioning of LT panel outdoor type 415 Volts, 50 Hz, 3 phase, 4 wire for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for indoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for aluminium bus bars 600 Amps capacity, hinged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following accessories suitable for incoming/outgoing arrangements complete all as specified and directed:- (a) 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 50 KA, Incomer -1 No(b) 4 Pole MCCB 315 Amp, 50 Hz, 415 V with rupturing capacity 36 KA-01(b) 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 36 KA,-01 No(c) 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, -01 No(d) 2 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, -01 No(d) Digital Multifunctional VAF Meter -01 Nos (e) CT\"s 400/5- set of 3 (g) LED type Indication lamps (RYB)-one set of 03 (for each incoming and outgoing)Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr in Charge /GE before commencement of work. (ii) Switch gear and connected items should be of approved make. (iii) Bottom portion of panel should be 30 cm above from the ground level. |
| 5 | Fabricate, supply, install, testing and commissioning of LT panel outdoor type 415 Volts, 50 Hz, 3 phase, 4 wire for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for outdoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for aluminium bus bars 400 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specified and directed:- (a) 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, Incomer -1 No(b) 3 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA-03 Nos(c) 2 Pole MCCB 40 Amps, 50 Hz , 415V with rupturing capacity 16 KA-01 Nos (d) 2 Pole MCCB 32 Amps, 50 Hz , 415V with rupturing capacity 16 KA-01 Nos (d)Digital Multifunctional VAF Meter -01 nos(e) CT\"s 200/5- set of 3 No(e) LED type Indication lamps (RYB)-one set (for each incoming and outgoing)Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr in Charge /GE before commencement of work. (ii) Switch gear and connected items should be of approved make. (iii) Bottom portion of panel should be 30 cm above from the ground level. |
| 6 | Fabricate, supply, install, testing and commissioning of LT panel Outdoor type 415 Volts, 50 Hz, 3 phase, 4 wire suitable for accommodating the following accessories totally enclosed self supporting structure fully compartmentalized suitable for outdoor door use with bottom cable entry with suitable cable glands made out of CRCA sheet 3.15mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for aluminium bus bars 600 Amps capacity, hinged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following accessories suitable for incoming/outgoing arrangements complete all as specified and directed:- (a) 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA, Incomer -1 No(b) 4 Pole MCCB 315 Amp, 50 Hz, 415 V with rupturing capacity 36 KA-01Nos (c) Onload changeover switch 4 Pole 315 Amps -01 Nos (d) 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 36 KA-01Nos (e) 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA-01Nos (f)Digital Multifunctional VAF Meter -01(g) CT\"s 400/5- set of 3 No(h) LED type Indication lamps (RYB)-one setNote : (i) Contractor has to get the approval of drawings of LT panel from the Engr in Charge /GE before commencement of work. (ii) Switch gear and connected items should be of approved make. (iii) Bottom portion of panel should be 30 cm above from the ground level. |
| 7 | Supply,install,testing and commissioning of LT Panel board CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 300 Amps rating mounted on porcelain insulators .The panels shall be factorymade, double door, made out of 3.15 mm thick MS sheettotally enclosed dust, vermin and rust prooffront operated, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable sizeincludinglugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: -INCOMIMG:(a) 4 Pole MCCB 200Amp, 50 Hz, 415 V with rupturing capacity 25 KA, Incomer -1 NoOUTGOING(b) 4 Pole MCCB 100Amp 25 KA - 02 Nos (c) 4 Pole MCCB 63 Amp 16 KA -01 Nos (d) 3 Pole MCCB 32 Amps 16KA-01 Nos (b)Digital Volt meter (0-500 V)-01 No(c)Digital Ammeter-01 No(d) CT\"s 200/5- set of 3 No(e) LED type Indication lamps (RYB)-one set |
| 8 | Supply, installation and commissioning in repair LT out door loop in loop out terminal box with sloping canopy of size 600x600x450mm made out of 3.15 mm thick CRCA sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide, front and rear hinged doors mounted on 50x50x6 mm MS angle iron frame 90 cm height erected in ground with PCC foundation 1:4;8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 300mm lengthof capacity 600 Amps suitable for 8 outgoings respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 200 Amps 4 pole, 415 Amps, 50 Hz of breaking capacity 25 KA as incomer with RYB Indicator, including taking down old terminal boxes complete all as specified and directed.Note : (i) Contractor has to get the approval of drawings of LT panel from the Engr in Charge /GE before commencement of work. (ii) Switch gear and connected items should be of approved make. (iii) Bottom portion of panel should be 30 cm above from the ground level. |
| 9 | M&L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to25X4 mm galvanised iron stripas earth lead upto a length of 7.5 metre long by means of bolts, nuts, washers etc. and protected by GI pipe light grade 15mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc complete all as specified and directed.Note :(a)Earthing value should be less than 5 ohms.(b)If desired value of earth resistance not achieved during testing, the earthing work shall be redone by the contractor at free of cost to achieve the desire value of earthing resistance. The rate quoted by the contractor deemed to be inclusive of the provision. |
| 10 | Supply and laying in trenches, LT underground cable of size 10 Sqmm4 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as specified and directed. |
| 11 | All as per item No 10 here-in-before but 16 Sqmm 4 core |
| 12 | All as per item No 10 here-in-before but25 Sqmm 3.5 core |
| 13 | All as per item No 10 here-in-before but 35 Sqmm 3.5 core |
| 14 | All as per item No 10 here-in-before but 50 Sqmm 3.5 core |
| 15 | All as per item No 10 here-in-before but 70 Sqmm 3.5 core |
| 16 | All as per item No 10 here-in-before but 95 Sqmm 3.5 core |
| 17 | All as per item No 10 here-in-before but 185 Sqmm 3.5 core |
| 18 | All as per item No 10 here-in-before but 240 Sqmm 3.5 core |
| 19 | All as per item No 10 here-in-before but 300 Sqmm 3.5 core |
| 20 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed. |
| 21 | Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and as directed. |
| 22 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 23 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and as directed. |
| 24 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation complete all as specified and as directed. |
| 25 | M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) for stay and coping for poles including necessary form work to exposed surface finished smooth and even complete all as specified and as directed. |
| 26 | Supply and laying GI tubing light grade 50mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable complete all as specified and as directed. |
| 27 | Supply and laying GI tubing light grade 80mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable complete all as specified and as directed. |
| 28 | M&L for boring of holes under roof, pavement, hardstanding by trenchless technology and necessary machine including GI pipe of 50/80/100mm dia suitable for 0.4mpa working pressure complete all as specified and as directed. |
| 29 | Supply and fix in repair energy saving rectangular LED flood light fitting 150 Watts, 240 volts AC, cool white colour, CCT5700°K, CRI>70, THD<10%, system lumens not less than 100 lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories complete all as specified and as directed. |
| 30 | Supply and fixing in repairs of 7 metre high hot dipped octagonal poles with 130mm bottom dia & 70mm top dia made up of 3mm thick HT Sheet alongwith base plate of size 200x200x12mm including foundation bolts & bracket of size M20x600mm EN 8 grade \"J\" type foundation bolts and numbering of poles, in white paint over black painted back ground at a height of 1.5m from bottom of pole with 5cm large bold letters 2\" (inch) wide with etc including accessories as required complete all as specified and directed including dismantling existing pole. |
| 31 | Supply and fix in repair LED street light fitting 70/72 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed. |
| 32 | Supply and fix in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed. |
| 33 | Supply and fixing in repair, “Lithium based Energy Efficient Integrated Solar Street Light of 40Watt”inrust proof Aluminium housingwith Monocrystalline Solar PV Panel of 75W(-0/+4W)Mono, Lithium Battery 12.8V, 42AH(BIS Certified), IP 65, High brightness W-LED(150 Lm/watt) lamp with aluminium reflector for better light distribution,Colour Temperature 6500K +500K, Microcontroller based charge controller cum driver, automatic dimming function( with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 5 degree C to (+) 45 degree C, Charging time 1 day and Autonomy 2 days with dimming Protections: Short Circuit, overload, Reverse polarity and battery protections complete all as specified and directed |
| 34 | Supply and fixing in repair of 6 metre high hot dipped octagonal poles with 130mm bottom dia & 70mm top dia made up of 3mm thick HT Sheet alongwith base plate of size 200x200x12mm including foundation bolts of size M20x300mm EN 8 grade \"J\" type foundation bolts and numbering of poles, in white paint over black painted back ground at a height of 1.5m from bottom of pole with 5 cm large bold letters 2\" (inch) wide with etc including accessories as required and complete all as specified and directed including dismantling existing pole. |
| 35 | M&L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 36 | M&L for local sand dry, filling in trenches or around under ground cable complete all as specified and directed. Note: Consolidated thickness will be considered for payment. |
| 37 | M&L for aggregate for spreading / filling loose broken stone/boulders of 40mm to 80mm graded complete all as specified and directed. |