| 1 | Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars, etc. but excluding ashlar facing, dressed stone work and precast concrete articles etc complete all as specified and directed. |
| 2 | M&L for brick work with old size fly ash bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 3 | M&L for brick work with sub class B bricks (Except bricks), straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 4 | M&L for 15 mm thick rendering on fair faces of brick work or concrete surface with cm (1:4) finishing fair and even complete all as specified and directed at site. |
| 5 | Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified. |
| 6 | M&L for Providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in copings, bed plates, drain channels including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed at site. |
| 7 | De-silting/cleaning of drain bed from grass/loose earth, roots etc complete all as specifed and directed. |
| 8 | Excavation in trenches n.exc 1.50 mtr wide and n. exc 1.50 mtr depthfor foundation etc or for shafts , wells, cesspits, manholes , pier holes etc n.exc 10 Sqm on plan & n. exc 1.5 m in depth andgetting out in soft/loose soil complete all as specified and directed. |
| 9 | M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) in surface channels and drain complete all as specified and directed at site. |
| 10 | Extra for forming fair finished drain or channel 45 cm inner girth in cement, concrete, using extra cement, including forms, moulds, mitered/stopped end etc complete all as specified and directed. |
| 11 | Description same all as per Item No 10 here in above but Add or deduct for each 25 mm girth or part thereof over or under 30 cm complete all as specified and directed. |
| 12 | Returning filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in soft/loose soil complete all as specified and directed. |
| 13 | Removal of excavated material (soil)to a distance exc250 mtrbut n exc 500 m and depositing where directed at a level n. exc 1.50 mtr above the starting point complete all as specified and directed |
| 14 | S&F for 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to walls with and including suitable size PVC clamps complete all as specified and directed. |
| 15 | M&L for cement concrete 1:4:8 , type D-2 using 40 mm graded stone aggregateas in fdn , filling and mass concrete, concrete bedcomplete all as specified and directed . |
| 16 | S&F for 450 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed. |
| 17 | Demolition of reinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) incl Separating, scraping and cleaning of reinforcement complete all as specified and directed. |
| 18 | Removing demolished building materials etc. to a distance of exc 100m but n exc 500 m, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed. |
| 19 | M&L for providingRCC 1:2:4 type B-1 using 20mmgraded stone aggregateas in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, cover slabs and in shelves and the like complete all as specified and directed. |
| 20 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 21 | M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for fair finished surface complete all as specified and directed. |
| 22 | M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in manhole covers/drain cover with weep hole/ without weep holes etc including necessary form work set in CM1:4 complete all as specified and directed. |
| 23 | M&L for mild steel TMTbars 10mm dia and over cut to length , bent to shape required including cranking bending etc and binding with mild steel wire (annealed ) not less than 0.90 mm dia as in reinforcement complete all as specified and directed. |
| 24 | Schedule of Credit (MINUS) Rs. 50,000.00 B/F from Serial Page No.[Note : Detailsof items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum |