| 1 | Ion meter with Electrode and accessories for fluoride & NitrateMeter: pH/Ion/ mV-Redox-ORP/ Temperature Benchtop meter with electrode for testing both fluoride & Nitrate separately in water samples. Technical Specification: pH • Range: -2.000 to 20.000 • Resolution 0.1, 0.01, 0.001 • Accuracy ±0.002 pH + 1 LSD • Calibration Points Up to 5 • Buffer Sets: USA/ NIST/ DIN/ Custom ORP • Range ±2000.0 mV • Rel. mV Range ±2000.0 mV • Accuracy ±0.2 mV • Resolution 0.1 mV • ION • Concentration 0.001 to 19999 ppm • Resolution Up to 3 digits • Relative Accuracy ±0.5 % full scale (monovalent) and 1 % full scale (divalent) • Calibration Points Up to 8 • Temperature • Range 0 to 100 °C, 32 to 212 ºF • Resolution 0.1 • Accuracy ±0.3 °C/ ±0.5 ºF • Compensation: Auromatic Temperature Correction • Other Requirement: Auto buffer recognition, Memory 500 with time and date stamp • RS 232 • Alarm for Calibration Due & Out of Range alurm • Auto Logging function. |
| 2 | Fluoride Electrode of Ion MeterSame Make that of the Ion Meter |
| 3 | Nitrate Electrode of Ion MeterSame Make that of the Ion Meter |
| 4 | Manifold filtration Assembly (to be used for micobiological Test)* Sturdy and easy to clean SS filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * Specification: # Funnel with inbuilt clamp: made of SS 316, Capacity: 300 mL, SS filter support base, SS Support Screan: 47 mm, made of SS 316L; Filtration area 9.6 cm2; Silicon Stopper: Size 8, with silicon lid and silicon o ring. # Filtration Manifold: 3 place manifold, Made of SS 316, Valves made of PTEE, Connection 12 mm; Suitable for both PP and SS funnel with rubber stopper fittings. # Vacuum Pump: Oil free, Piston powered, suitable to be used with 3 possition manifold; Max flow rate: 34 L/ min; Vaccum Stage: Double. Max Vaccum: 100 mbar. The vaccum pump should also have a vacuum suction bottle to protect the pump\"s componennt by preventing liquid or solid material from entering the pump during filtration process. |
| 5 | Voltage stabilizer (3 phase)# Capacity- 3 KVA # Input Voltage Range: 295 V - 465 V Normal range # Output Voltage Range 380 V / 400 V / 415 V # Output Regulation: ± 1 %; # Output Settability: 380 V - 420 V; # Frequency: 47 Hz - 53 Hz; Correction Rate: 70 V/ sec; # Aircooled Servo Stabilizer, Three phase. |
| 6 | Heating Mantle (Single station)⋆ Should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process ⋆ Technial specification: Flask capacity 250 mL, working Temp range: Ambiant + 5 to 350 degree celcius. Accuracy: 1.0 degree celcius, Display: LED display with temperature, Time; Construction Material: MS; Power consumption : 150 W |
| 7 | Semi Automatic Digestor for COD Analysis with all assssories• Material of construction – Epoxy painted with chemical resistant coating; • Temperature Range – Ambient to 450 Deg C # • Stability of Temperature – ± 0.5 Deg C # • Temperature Calibration - Automatic; Selectable Ramp: Upto 4 per program; Digestion Time Range: 1 to 999 minutes; Time selection: 1 minutes steps; Countdown: Digital readout; Heating places - 6 possition; Size of Tubes: 250 mL test tubes (42 mm); Power 1000 W; Number of Programmable Methods – 20 numbers. # • The thermal digestion unit should have high thermal homogeneity # • The setup should have small footprint. |
| 8 | Digital Thermometer with probe# Mini LCD Thermometer # Type: Digital, # Sensor Cable Length: 1 meter water proof probe # Batteries: 2 x batteries should be included, # Temperature Range: - 50 - 110 oC, # Temperature Measurement Accuracy: ± 1 0C |
| 9 | Micropippete Stand#Self-standing holder accommodates most major brands of pipettes. #Material: PMMA, # Capacity: 5 pipptes/stand |
| 10 | Conical flask draining rack#Material: Acrylonitrile-Butadiene-Styrene/polycarbonate, # No. of Pegs: 20, Please Enable Macros to View BoQ information |