| 1 | (A) TOILET BLOCK : |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. - All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 4 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 6 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 7 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo-Mechanically Treated bars |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 12 | (a) Foundations, footings, bases of columns, etc. for mass concrete. |
| 13 | (b) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 14 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 15 | (d) Suspended floors, roofs, landings, balconies and access platform. |
| 16 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 17 | Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricksin superstructure above plinth level upto floor V level in : Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 18 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : Local best quality Tolhao wood. |
| 19 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Local best quality Tolhao wood : 30 mm thick shutters |
| 20 | Providing and fixing in position collapsible steel shutters with vertical channels 20xl0x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 21 | Providing and fixing ISI marked oxidised M.S.sliding door bolts with screws etc. complete. (a) 250x16 mm |
| 22 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (a) 100 x 10mm |
| 23 | (b) 150 x 10mm |
| 24 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : (a) 75mm |
| 25 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate. |
| 26 | 12 mm cement plaster of mix : 1:4 (1 cement : 4 fine sand) |
| 27 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:3 ( 1 cement : 3 fine sand) |
| 28 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including priming coat of whiting to give an even shade:- |
| 29 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 30 | P/Fixing UPVC soil, waste, rain water and vent pipes i/c all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge :110 mm dia. |
| 31 | P/Fixing UPVC soil, waste, rain water and vent pipes i/c all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge : 75 mm dia. |
| 32 | P/Fixing 100mm HCI bent of required degree with access door, insertion rubber washer 3mm thick bolt and nuts complete. |
| 33 | P/Fixing 50mm HCI bent of required degree with access door, insertion rubber washer 3mm thick bolt and nuts complete. |
| 34 | P/Fixing MS holder bat clamps of approved design to 100mm HCI pipe socket i/c costing of hole and making good the wall etc. |
| 35 | P/Fixing MS holder bat clamps of approved design to 50mm HCI pipe socket i/c costing of hole and making good the wall etc. |
| 36 | P/Fixing white vitreous china water closet squatting pan Indian type 450 mm |
| 37 | P/Fixing white vitreous china pedestal type (European type/wash down type) water closet pan |
| 38 | White Vitreous China Flat back wash basin of size 450x300mm with single 15mm C.P brass pillar tap |
| 39 | (B) WATER SUPPLY |
| 40 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 20mm nominal outer dia Pipes (Internal work) |
| 41 | 20mm nominal outer dia Pipes |
| 42 | P/Fixing brass bib cock of approved quality. 15mm nominal bore |
| 43 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore |
| 44 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 20 mm dia nominal bore (External work) |
| 45 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 46 | (C) INTERNAL ELECTRIFICATION INSTALLATION : |
| 47 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd. |
| 48 | Group A |
| 49 | Group B |
| 50 | Group C |
| 51 | Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable inPVC sassing & capping etc.as reqd. |
| 52 | 2X2.5mm2+1X2.5mm2 earth wire |
| 53 | Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd. |
| 54 | 5/6 amps switch |
| 55 | Wiring for submain with 10m2 weather proof twin core Al. cond. Cableand G.I. bearer wire as reqd. |
| 56 | S/F brass batten/angle holder i/c connection etc.as reqd. |
| 57 | S/F 12W LED bulb. |
| 58 | S/F 5 amp to 32 amp rating 230V \"B\" series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole |
| 59 | Supplying & fixing (following rating) double pole 240V isolatorin existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp |
| 60 | (D) MOTOR PUMP: |
| 61 | Motor pump set i/c energisation |