| Sl. No. | Item Description |
| 1 | Note:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender documents, all drawings & all corrigendum/ amendments and General conditions of contracts before entering / quoting the rates.Lumpsum price worked out by the tenderer for BUILDING as listed in Schedule ‘A’ Part-I |
| 2 | Lumpsum price workedout by the tenderer for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATION as listed in Schedule ‘A’ Part-II. |
| 3 | Lumpsum price workedout by the tenderer for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III. |
| 4 | Lumpsum price workedout by the tenderer for RCC CULVERT as listed in Schedule ‘A’ Part-IV. |
| 5 | Lumpsum price workedout by the tenderer for AREA DRAINAGE INCL SUMP AND STONE / BOULDER PITCHING & POND LINING as listed in Schedule ‘A’ Part-V. |
| 6 | Lumpsum price workedout by the tenderer for RCC DYKE WALL as listed in Schedule ‘A’ Part-VI. |
| 7 | Lumpsum price workedout by the tenderer for MISC B/R WORKS as listed in Schedule ‘A’ Part-VII. |
| 8 | Lumpsum price workedout by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VIII. |
| 9 | Lumpsum price workedout by the tenderer for EXTERNAL ELECTRIC SUPPLY INCL DG SET as listed in Schedule ‘A’ Part-IX. |
| 10 | Subtotal of Schedule \"A\" Part-I to Part-IX |
| 11 | NOTE:Schedule \"A\" Part-X (MISC B/R & E/M SERVICES) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 siginifies this fact only. |
| 12 | Supplying and Laying at site, factory made (wet cast) high strength Pre-cast Reinforced Cement Concrete U-Shape Drain T-25 of internal size (600 mm × 600 mm) with provision for suitable Drain Covers/ Lids at top and minimum grade of concrete shall be M-40 (Design Mix) and as specified including the following: a)Drain units must be steam cured in a controlled environment and manufactured by using high performance Self-Compacting Concrete and must be designed considering a wheel load of 10 Tones Axel Load/ 5 Tons Wheel Load for heavy vehicular movement. The Drain units shall have a tie shape groove of 10-20 mm width and 25 mm depth on both sides for joining two precast units.b) Design should conform to BIS/ Guidelines/ other extant Codal provisions, furthermore taking into considerations the expected handling and erection stresses etc.c) The Precast Drain shall be manufactured using water tight formwork made up of automobile steel to have accurate dimensional product. d)Steel reinforcement with TMT bars (Fe 500/ 550 D) cut, bent, cranked, or spiraled for hoops, hooked and tied with annealed binding wire not less than 0.9 mm dia, all as per IS 456 and IS 1343. e)Safe transportation from factory to site, including loading, unloading, stacking, and yard handling. f)Laying, levelling, alignment, and jointing of drain units over a prepared PCC bed, sealing of joints by using non shrink mortar sealant material duly approved by GE. g) The Design of Precast RCC Drain shall be approved/ Proof Checked by any IIT/ NIT before mass production.h) All complete in compliance of IS: 15916: 2020 and any other latest Codal Provisions applicable and as per approved methodology, design mix, shop drawings, and directions. |
| 13 | Supplying and Laying at site, factory made (wet cast) high strength Pre-cast Reinforced Cement Concrete U-Shape Drain T-25 of internal size (750 mm × 750 mm) with provision for suitable Drain Covers/ Lids at top and minimum grade of concrete shall be M-40 (Design Mix) and as specified including the following: a)Drain units must be steam cured in a controlled environment and manufactured by using high performance Self-Compacting Concrete and must be designed considering a wheel load of 10 Tones Axel Load/ 5 Tons Wheel Load for heavy vehicular movement. The Drain units shall have a tie shape groove of 10-20 mm width and 25 mm depth on both sides for joining two precast units.b) Design should conform to BIS/ Guidelines/ other extant Codal provisions furthermore taking into considerations the expected handling and erection stresses etc.c) The Precast Drain shall be manufactured using water tight formwork made up of automobile steel to have accurate dimensional product. d)Steel reinforcement with TMT bars (Fe 500/ 550 D) cut, bent, cranked, or spiraled for hoops, hooked and tied with annealed binding wire not less than 0.9 mm dia, all as per IS 456 and IS 1343. e)Safe transportation from factory to site, including loading, unloading, stacking, and yard handling. f)Laying, levelling, alignment, and jointing of drain units over a prepared PCC bed, sealing of joints by using non shrink mortar sealant material duly approved by GE. g) The Design of Precast RCC Drain shall be approved/ Proof Checked by any IIT/ NIT before mass production.h) All complete in compliance of IS: 15916: 2020 and any other latest Codal Provisions applicable and as per approved methodology, design mix, shop drawings, and directions. |
| 14 | Supplying and Laying at site, factory made (wet cast) high strength Pre-cast Reinforced Cement Concrete U-Shape Drain T-25 of internal size (1200 mm × 1200 mm) with provision for suitable Drain Covers/ Lids at top and minimum grade of concrete shall be M-40 (Design Mix) and as specified including the following: a)Drain units must be steam cured in a controlled environment and manufactured by using high performance Self-Compacting Concrete and must be designed considering a wheel load of 10 Tones Axel Load/ 5 Tons Wheel Load for heavy vehicular movement. The Drain units shall have a tie shape groove of 10-20 mm width and 25 mm depth on both sides for joining two precast units.b) Design should conform to BIS/ Guidelines/ other extant Codal provisions, furthermore taking into considerations the expected handling and erection stresses etc.c) The Precast Drain shall be manufactured using water tight formwork made up of automobile steel to have accurate dimensional product. d)Steel reinforcement with TMT bars (Fe 500/ 550 D) cut, bent, cranked, or spiraled for hoops, hooked and tied with annealed binding wire not less than 0.9 mm dia, all as per IS 456 and IS 1343. e)Safe transportation from factory to site, including loading, unloading, stacking, and yard handling. f)Laying, levelling, alignment, and jointing of drain units over a prepared PCC bed, sealing of joints by using non shrink mortar sealant material duly approved by GE. g) The Design of Precast RCC Drain shall be approved/ Proof Checked by any IIT/ NIT before mass production.h) All complete in compliance of IS: 15916: 2020 and any other latest Codal Provisions applicable and as per approved methodology, design mix, shop drawings, and directions. |
| 15 | Supplying and Laying at site, factory made (wet cast) high strength Pre-cast Reinforced Cement Concrete U-Shape Drain T-25 of internal size (450 mm × 450 mm) with provision for suitable Drain Covers/ Lids at top and minimum grade of concrete shall be M-40 (Design Mix) and as specified including the following: a)Drain units must be steam cured in a controlled environment and manufactured by using high performance Self-Compacting Concrete and must be designed considering a wheel load of 10 Tones Axel Load/ 5 Tons Wheel Load for heavy vehicular movement. The Drain units shall have a tie shape groove of 10-20 mm width and 25 mm depth on both sides for joining two precast units.b) Design should conform to BIS/ Guidelines/ other extant Codal provisions furthermore taking into considerations the expected handling and erection stresses etc.c) The Precast Drain shall be manufactured using water tight formwork made up of automobile steel to have accurate dimensional product. d)Steel reinforcement with TMT bars (Fe 500/ 550 D) cut, bent, cranked, or spiraled for hoops, hooked and tied with annealed binding wire not less than 0.9 mm dia, all as per IS 456 and IS 1343. e)Safe transportation from factory to site, including loading, unloading, stacking, and yard handling. f)Laying, levelling, alignment, and jointing of drain units over a prepared PCC bed, sealing of joints by using non shrink mortar sealant material duly approved by GE. g) The Design of Precast RCC Drain shall be approved/ Proof Checked by any IIT/ NIT before mass production.h) All complete in compliance of IS: 15916: 2020 and any other latest Codal Provisions applicable and as per approved methodology, design mix, shop drawings, and directions. |
| 16 | Supplying and Laying at site, factory made (wet cast) high strength Pre-cast Reinforced Cement Concrete U-Shape Drain T-25 of internal size (900 mm × 900 mm) with provision for suitable Drain Covers/ Lids at top and minimum grade of concrete shall be M-40 (Design Mix) and as specified including the following: a)Drain units must be steam cured in a controlled environment and manufactured by using high performance Self-Compacting Concrete and must be designed considering a wheel load of 10 Tones Axel Load/ 5 Tons Wheel Load for heavy vehicular movement. The Drain units shall have a tie shape groove of 10-20 mm width and 25 mm depth on both sides for joining two precast units.b) Design should conform to BIS/ Guidelines/ other extant Codal provisions furthermore taking into considerations the expected handling and erection stresses etc.c) The Precast Drain shall be manufactured using water tight formwork made up of automobile steel to have accurate dimensional product. d)Steel reinforcement with TMT bars (Fe 500/ 550 D) cut, bent, cranked, or spiraled for hoops, hooked and tied with annealed binding wire not less than 0.9 mm dia, all as per IS 456 and IS 1343. e)Safe transportation from factory to site, including loading, unloading, stacking, and yard handling. f)Laying, levelling, alignment, and jointing of drain units over a prepared PCC bed, sealing of joints by using non shrink mortar sealant material duly approved by GE. g) The Design of Precast RCC Drain shall be approved/ Proof Checked by any IIT/ NIT before mass production.h) All complete in compliance of IS: 15916: 2020 and any other latest Codal Provisions applicable and as per approved methodology, design mix, shop drawings, and directions. |
| 17 | Supply and fixing of Factory made Precast Reinforced Cement Concrete Drain Covers/ Lidswith M-40 grade concrete (Design Mix) of size suitable for 450 mm x 450 mm Precast Drain with diamond shaped anti-skid chequered impression and sufficient perforations for drainage of storm water. The Drain Cover should be Pre-casted using Automobile Steel Moulds/ Formwork suitable for Self Compacting Concrete of required shape and size complete all as per design and as specified. The Design of Precast RCC Drain Covers/ Lids shall be approved/ Proof Checked by any IIT/ NIT before mass production. The contractor has the option to supply and fix Reinforced Cement Polymer Concrete drain cover suitable for heavy vehicular traffic as per details aforementioned without any financial effect. |
| 18 | Supply and fixing of Factory made Precast Reinforced Cement Concrete Drain Covers/ Lidswith M-40 grade concrete (Design Mix) of size suitable for 600 mm x 600 mm Precast Drain with diamond shaped anti-skid chequered impression and sufficient perforations for drainage of storm water. The Drain Cover should be Pre-casted using Automobile Steel Moulds/ Formwork suitable for Self Compacting Concrete of required shape and size complete all as per design and as specified. The Design of Precast RCC Drain Covers/ Lids shall be approved/ Proof Checked by any IIT/ NIT before mass production. The contractor has the option to supply and fix Reinforced Cement Polymer Concrete drain cover suitable for heavy vehicular traffic as per details aforementioned without any financial effect. |
| 19 | Supply and fixing of Factory made Precast Reinforced Cement Concrete Drain Covers/ Lidswith M-40 grade concrete (Design Mix) of size suitable for 750 mm x 750 mm Precast Drain with diamond shaped anti-skid chequered impression and sufficient perforations for drainage of storm water. The Drain Cover should be Pre-casted using Automobile Steel Moulds/ Formwork suitable for Self Compacting Concrete of required shape and size complete all as per design and as specified. The Design of Precast RCC Drain Covers/ Lids shall be approved/ Proof Checked by any IIT/ NIT before mass production. The contractor has the option to supply and fix Reinforced Cement Polymer Concrete drain cover suitable for heavy vehicular traffic as per details aforementioned without any financial effect. |
| 20 | Supply and fixing of Factory made Precast Reinforced Cement Concrete Drain Covers/ Lidswith M-40 grade concrete (Design Mix) of size suitable for 900 mm x 900 mm Precast Drain with diamond shaped anti-skid chequered impression and sufficient perforations for drainage of storm water. The Drain Cover should be Pre-casted using Automobile Steel Moulds/ Formwork suitable for Self Compacting Concrete of required shape and size complete all as per design and as specified. The Design of Precast RCC Drain Covers/ Lids shall be approved/ Proof Checked by any IIT/ NIT before mass production. The contractor has the option to supply and fix Reinforced Cement Polymer Concrete drain cover suitable for heavy vehicular traffic as per details aforementioned without any financial effect. |
| 21 | Supply and fixing of Factory made Precast Reinforced Cement Concrete Drain Covers/ Lidswith M-40 grade concrete (Design Mix) of size suitable for 1200 mm x 1200 mm Precast Drain with diamond shaped anti-skid chequered impression and sufficient perforations for drainage of storm water. The Drain Cover should be Pre-casted using Automobile Steel Moulds/ Formwork suitable for Self Compacting Concrete of required shape and size complete all as per design and as specified. The Design of Precast RCC Drain Covers/ Lids shall be approved/ Proof Checked by any IIT/ NIT before mass production. The contractor has the option to supply and fix Reinforced Cement Polymer Concrete drain cover suitable for heavy vehicular traffic as per details aforementioned without any financial effect. |
| 22 | Supply and fixing of HDPE Pipe of 300 mm dia laid in trenches at Suitable depth including provision of geo-textile cloth of required size at front opening pipe complete all as specified and directed. |
| 23 | M & L for Pond Lining on all vertical as well as bottom surface of pond using geosynthetic clay liners (GCLs) consisting of a layer of bentonite clay sandwiched between two layers of geotextile fabric to create a protective layer on the slopes and bottom, preventingsoil errosion complete all as specified and directed. |
| 24 | Supply and fixing 9 watt inverter type LED bulb with in-built rechargeable lithium ion battery of minimum capacity 2200 mAh for min 4 hours emergency backup. |
| 25 | Supply and fixing of blanking plate for DB. |
| 26 | Supply installation testing commissioning of automatic self priming pump set of 25 HP3 phase 415 V 50 Hz suitable for min 13 M head and min 225000 LPH discharge including connection to starterincluding necessary accessories required for pump, including CI foot valve of size 150 mm or as required, capable of discharging sludge and solid upto 40 mm size complete all as specified and directed. |
| 27 | Supply installation testing commissioning of automatic self priming pump set of 15 HP3 phase 415 V 50 Hz suitable for min 13 M head and min 125000 LPH discharge including connection to starterincluding necessary accessories required for pump, including CI foot valve of size 100 mm or as required, capable of discharging sludge and solid upto 35 mm size complete all as specified and directed. |
| 28 | Supply and fixing of PVC heavy duty suction hose pipe including clamp and other fixing arrangements of sizes 150 -200 mmfor connection /inlet/outlet of sewage/rainwater pump to required location as directed. |
| 29 | Supply and fixing of PVC heavy duty suction hose pipe including clamp and other fixing arrangements of sizes 100 - 125 mmfor connection /inlet/outlet of sewage/rainwater pump to required location as directed. |
| 30 | Supply and Install Diesel Engine driven self priming dewatering pump ofsuc & del 150x150 mm, head range 12 Mtr to 28 Mtr, Discharge capacity min 70 LPS to 18 LPS pump should have capability of handling solid particular of size min 40 mmalong with diesel engine of appx capacity 25 HP complete all as specified and directed. |
| 31 | Supply and Install Diesel Engine driven self priming dewatering pump ofsuc & del 100x100 mm, head range 12 Mtr to 28 Mtr, Discharge capacity min 40 LPS to 9 LPS pump should have capability of handling solid particular of size min 23 mmalong with diesel engine of appx capacity 16 HP complete all as specified and directed. |
| 32 | Supply, installation, testing and commissinoningLT Feeder Panel of size 1500 x 1500 x 500, 3 phase ,4 wire ,415 volts, AC ,50Hz ,indoor type, floor mounted, free standing, dust and vermin proof, air ventilationmade out of 2 mm thick CRCA sheet and suitable sizedangle iron and flat duly powder coated and any manufacturer shall befollowed CPRI norms and as approved by GE.Panel shall have front opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, including civil work/PCC foundation as per site requirement complete all as specified and directed including comprising of following:- Note:Panel will be accomodated in New prop.pump house.Incoming:(a) MCCB 200 Amps,FP,36 KA,415 volts,50Hz- 01 Nos(B)Onload manual changeover 200 AOut going:MCCB 40Amps, TP 25 KA 415 volts, 50 Hz-03NosFASDstarter,15 HP- 3 NosSingle phasing preventor -3 setDigital voltmeter,amp meter,selector switch incoming -1 SetDigital voltmeter,amp meter,selector switch out going - 1 SetLED phase indication lamps RYB-01 set Aluminium bus bar TPN 300 Amps rating -01 setCT,s 200/5- 3 setMCB 6 A SP 10 KA for protection.-3 nosPush buttons -3 Set |
| 33 | Supply, installation, testing and commissinoningLT Feeder Panel of size 1500 x 1500 x 500, 3 phase ,4 wire ,415 volts, AC ,50Hz ,indoor type, floor mounted, free standing, dust and vermin proof, air ventilationmade out of 2 mm thick CRCA sheet and suitable sizedangle iron and flat duly powder coated and any manufacturer shall befollowed CPRI norms and as approved by GE.Panel shall have front opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, including civil work/PCC foundation as per site requirement complete all as specified and directed including comprising of following:- Note:Panel will be accomodated in New prop.pump house.Incoming:(a) MCCB 250 Amps,FP,36 KA,415 volts,50Hz- 01 Nos(B)Onload manual changeover 250 AOut going:MCCB 200Amps, TP 25 KA 415 volts, 50 Hz-01NoMCCB 63Amps, SP 25 KA 415 volts, 50 Hz-03NosFASDstarter,25 HP- 3 NosSingle phasing preventor -3 setDigital voltmeter,amp meter,selector switch incoming -1 SetDigital voltmeter,amp meter,selector switch out going - 1 SetLED phase indication lamps RYB-01 set Aluminium bus bar TPN 400 Amps rating -01 setCT,s 250/5- 3 setMCB 6 A SP 10 KA for protection.-3 nosPush buttons -3 Set |
| 34 | Supply, installation, testing and commissinoningLT Feeder Panel of size 1200 x 1100 x 500, 3 phase ,4 wire ,415 volts, AC ,50Hz ,indoor type, floor mounted, free standing, dust and vermin proof, air ventilationmade out of 2 mm thick CRCA sheet and suitable sizedangle iron and flat duly powder coated and any manufacturer shall befollowed CPRI norms and as approved by GE.Panel shall have front opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, including civil work/PCC foundation as per site requirement complete all as specified and directed including comprising of following:- Note:Panel will be accomodated in New prop.pump house.Incoming:(a) MCCB 160 Amps,FP,36 KA,415 volts,50Hz- 01 Nos(B)Onload manual changeover 160 AOut going:MCCB 63Amps, TP 25 KA 415 volts, 50 Hz-03NosFASDstarter,25 HP- 2 NosSingle phasing preventor -3 setDigital voltmeter,amp meter,selector switch incoming -1 SetDigital voltmeter,amp meter,selector switch out going - 1 SetLED phase indication lamps RYB-01 set Aluminium bus bar TPN 200 Amps rating -01 setCT,s 150/5- 3 setMCB 6 A SP 10 KA for protection.-3 nosPush buttons -2 Set |
| 35 | Supply, installation, testing and commissinoningLT Feeder Panel of size 750 x 750 x 450, 3 phase ,4 wire ,415 volts, AC ,50Hz ,indoor type, floor mounted, free standing, dust and vermin proof, air ventilationmade out of 2 mm thick CRCA sheet and suitable sizedangle iron and flat duly powder coated and any manufacturer shall befollowed CPRI norms and as approved by GE.Panel shall have front opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, including civil work/PCC foundation as per site requirement complete all as specified and directed including comprising of following:- Note:Panel will be accomodated in New prop.pump house.Incoming:(a) MCCB 63 Amps,FP,25 KA,415 volts,50Hz- 01 Nos(B)Onload manual changeover 63 AOut going:MCCB 40Amps, TP 25 KA 415 volts, 50 Hz-01NoFASDstarter,15 HP- 01 NoSingle phasing preventor -1 setDigital voltmeter,amp meter,selector switch incoming -1 SetDigital voltmeter,amp meter,selector switch out going - 1 SetLED phase indication lamps RYB-01 set Aluminium bus bar TPN 200 Amps rating -01 setCT,s 60/5- 3 setMCB 6 A SP 10 KA for protection.-3 nosPush buttons -1 Set |
| 36 | Supply, installation, testing and commissinoningLT Feeder Panel of size 1500 x 1500 x 400, 3 phase ,4 wire ,415 volts, AC ,50Hz ,indoor type, floor mounted, free standing, dust and vermin proof, air ventilationmade out of 2 mm thick CRCA sheet and suitable sizedangle iron and flat duly powder coated and any manufacturer shall befollowed CPRI norms and as approved by GE.Panel shall have front opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, including civil work/PCC foundation as per site requirement complete all as specified and directed including comprising of following:- Note:Panel will be accomodated in New prop.pump house.Incoming:(a) MCCB 400 Amps,FP,50 KA,415 volts,50Hz- 01 NosOut going:MCCB 160Amps, 4P 36 KA , 50 Hz-01NosMCCB 100Amps, 4P 36 KA , 50 Hz-02NosMCCB 63Amps, 4P 36 KA , 50 Hz-03NosMCB 43Amps, TPN 10 KA 215 volts, 50 Hz-02NosMCB 43Amps, D 10 KA 215 volts, 50 Hz-02NosPower contractor MNX 32 3PAstronomocal timerDigital voltmeter,amp meter,selector switch incoming -1 SetDigital voltmeter,amp meter,selector switch out going - 3 SetLED phase indication lamps RYB-01 set Aluminium bus bar TPN 600 Amps rating -01 setCT,s 400/5- 3 setMCB 6 A SP 10 KA for protection.-3 nos |
| 37 | Supply, installation, testing and commissinoningLT Feeder Panel of size 1200 x 1100 x 500, 3 phase ,4 wire ,415 volts, AC ,50Hz ,indoor type, floor mounted, free standing, dust and vermin proof, air ventilationmade out of 2 mm thick CRCA sheet and suitable sizedangle iron and flat duly powder coated and any manufacturer shall befollowed CPRI norms and as approved by GE.Panel shall have front opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, including civil work/PCC foundation as per site requirement complete all as specified and directed including comprising of following:- Note:Panel will be accomodated in New prop.pump house.Incoming:(a) MCCB 160 Amps,FP,36 KA,415 volts,50Hz- 01 Nos(B)Onload manual changeover 160 AOut going:MCCB 63Amps, TP 25 KA 415 volts, 50 Hz-03NosFASDstarter,25 HP- 02 NosSingle phasing preventor -3 setDigital voltmeter,amp meter,selector switch incoming -1 SetDigital voltmeter,amp meter,selector switch out going - 1 SetLED phase indication lamps RYB-01 set Aluminium bus bar TPN 250 Amps rating -01 setCT,s 150/5- 3 setMCB 6 A SP 10 KA for protection.-3 nosPush buttons -2 Set |
| 38 | Material and labour for diversion/ Protection of HT cable ofsizes 95 Sq mm including 2 nos heat shrinkable joint ,4 mtr cable,excavation returning filling and HDPE pipe cover of dia 80 mm and length 4 mtr.Note:max 1 nos cable can be drawn in a single HDPE pipe complete all as specified and as directed. |
| 39 | Material and labour for diversion/Protection of HT cable ofsizes 120-400 Sq mm including 2 nos heat shrinkable joint ,4 mtr cable,excavation returning filling and HDPE pipe cover of dia 80 mm and length 4 mtr.Note:max 1 nos cable can be drawn in a single HDPE pipe complete all as specified and as directed. |
| 40 | Material and labour for diversion/Protection of GI Pipe of max sizes 80 mm dia including excavation ,opening the pipe inserting HDPE pipe and re laying with suitable fittins as requiredand returning filling etc as directed. |
| 41 | Material and labour for diversion/Protection of LT cable ofsizes 185- 400 Sq mm including 2 nos joint ,4 mtr cable,excavation returning filling and HDPE pipe cover of dia 80 mm and length 4 mtr.Note:max 1 nos cable can be drawn in a single HDPE pipe complete all as specified and as directed. |
| 42 | Material and labour for cutting hole and finishing as existing after fixing of radiator hot air discharge duct with MS pipe of dia 80 mm and asbostose rope insulation along with all other items required for throughing DG Pump smoke out of the building complete all as specified and as directed. |
| 43 | Material and labour for diversion/Protection of LT cable of max sizes 185 Sq mm including 2 nos joint ,4 mtr cable excavaation,returning filling etc and HDPE pipe cover of dia 80 mm and length 4 mtr.Note:max 2 nos cable can be drawn in a single HDPE pipe complete all as specified and as directed. |
| 44 | Material and Labour for taking down existing transformer max capacity 160 KVA, 11KV/ 433V after disconnecting cable lugs and etc and deposited to MES store yard not more than 1.5 Km away complete all as specified and as directed. |
| 45 | Supply install testing and commissioning Auto Mains Failure Silent type Diesel Engine Generating set 415 volts 100 KVA 3 -phasepower factor above 0.95, 50 Hz, 1500 RPM self exicited self regulated brushless AC generator installed including accoustic enclosure suitable for ambient condition at Barrackpore and should satisfy latest CPCB IV+ norms.and conforming to condition under IS 4722, 10001/10002, 13364, BS 5514/2613/5000 with following:-(i) The capacity of Generator set shall be net after all due derating factors as per relevant ISI design.(ii) Rate quoted shall be deemed to be inclusive of cable and terminations from Generator to the AMF Panel all as specified and directed(max distance 2 mtr).(iii) The quoted rate shall be deemed to be inclusive of first fill of oil/fuel and final successful acceptance test.(iv) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of half an hour on 10% overhead in presence of representative detailed by accepting Officer, all arrangements are to be made by the contractor for tests.(A). Alternator :-Standard design alternator rated at 100 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC,3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class \"H\" and voltage regulation of+ 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000, IS: 13364 and shall be in position to generate supply with frequecy regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and efficiency at 100 % load at 0.8 PF should be min 90 % shall generally confirm to BS - 2613/5000/ IS - 4722. |
| 46 | (B) Diesel Engine: - Adquate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details water cooled to drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexiable coupling multi cylinder multi stroke direct ignition, cold starting 1500 RPM, as per relevant ISI/BS -10001/10002/ 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- i) Fly wheel with housingii) Cooling system :- Moulded radiator with fan & belts.iii) Cooling Water pump :iv) Exhaust System :- Exhaust System complete with exhaust pipingupto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclousre.Exhaust gas turbo charger typeExhaust manifoldSilencer : Residual typeBellows |
| 47 | iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated/ (as recommended by OEM) for 1% speed /frequecy regulation.Fuel filtersFuel hosesv) Lub oil System :-Lubricating oil filterLubricating oil pumpvi) Air Intake System :- Air intake ManifoldAir cleaner dry typevii) Governor electronic / (as recommended by OEM)viii) Starting System :- Electric Self starter with and including battery charging alternator.ix) Batteries :- Batteries of maintenece free of capacity as recommended by the manufacturer complete with copper conductor multistranded leads of suitable length fromself starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and :Starter gear ringStart and stop push buttonIgnition key / SwitchHandling and operation : Salient features of accessories shall be as under: |
| 48 | Radiator with blower fanCorrosion inhibitor coolantPaper element filters for fuel, lub oil and by pass.Governer electronic/ (as recommended by OEM) controlled direct fuel injection systemFly wheel housing and fly wheel.x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standardpractice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display.xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine.xii) Coupling arrngement : - Flexiable coupling, fly wheel to suit flexiable coupling.xiii) Accessories :- AVM Pads built or separtely mounted to manufactrer base frames as per (as recommended by OEM) xv) Fuel Tank :- Daily service fuel tank (as recommended by OEM)with caliberated level indicating arrangement, stop cock, drain plug, complete on a common base in side the accoustic enclosure. |
| 49 | C) AMF Panel :- Factory made indoor type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally encosed with front and rear opeining of 415 volts 3 -phase4 - wire AC 50 Hz, including powder coated painted, Aluminium bus bar of of suitable size complete with internal wiring with PVC insulated single core copper condutor multistranded wire of 1100 volts grade of suitable capacity, all controls, indicators and standard fitting shall be as follows: Note:AMF panel will be installed in existing MRS.a) Digital Ammeter with selector switch of suitable capacity with CTs - 1 set.b) Digital Volt meter with slector switch- 1 Setc) Digital Frequency meter - 1 Nod) Digital KW meter - 1 Noe) Digital KWH meter panel mounted type- 1 Nof) Digital PF meter - 1 Nog) Annuciation with indication lamps for :(i) Low lub oil pressure.(ii) High Water Temperature.(iii) Engine over speed.(iv) Battery low voltage.Controls :-a) Load on Indicationb) Load off indicationc) Engine start push buttond) Engine stop push button |
| 50 | e) Fault accept / reset push buttonf) Battery Charger : (i) Transformer(ii) Rectifier(iii) Resistance(iv) DC Volt meter(v) DC Ammeter(vi) Charger rate selector switch.Note:Accoustic Enclosure:- Manufactured by OEM suitable for 100 KVA DG Set.(i) NAL approved as per CPCB(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(iii) The generating setbatteries and control panel should be inside the enclosure.(iv) Fuel tank should be in side the enclosure.v) The DG Set should be provided with external Emergency stop push button.vi) The enclosure should be suitably illuminated by CFL/FTL Lamp fittings.vii) The noise level should be 75 Db at 1m under free field conditions. |
| 51 | Subtotal of Schedule \"A\" Part-X |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |