| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring from woodenbattan orconduits (light, fan, socket or power) complete including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc. |
| 2 | M&L point wiring concealed in wall with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing in& including rigid PVC conduit in walls and on surface conduit for Beam/ceiling/cloumn portion FRLS grade ,ISI marked ,terminal box of suitable thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly and making good to the disturb surfaces with cement, matching with existing color by painting all as specified for the following :- |
| 3 | (a)One light/fan/bell point controlled by one by one way switch ( switch to be measured and paid separtely) |
| 4 | (b)One 3 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable asearth wire connected to common earth and to earth dully socket & switches to be measured and paid separately. |
| 5 | (c)-ditto- as above item No 2 (a) but Same board. |
| 6 | M&L One power point concealed in wall with insulated stranded copper conductor cable 2.5 Sqmm single core and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 2.5 Sqmm stranded conductor as earth wire including PVC cunduit connected to dolly complete all as specified. ( socket and switches to be measured and paid separately) |
| 7 | M&L point wiring in existing conduit with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing in existing rigid PVC conduit FRLS grade ,ISI marked ,without terminal box and with 3 mm thick hylam sheet cover for terminal boxes as per requirement at site also including porvision of earth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly and making good to the disturb surfaces with cement, matching with existing color by painting all as specified for the following :- |
| 8 | (a)One light/fan/bell point controlled by one by one way switch ( switch to be measured and paid separtely) |
| 9 | (b)One light point controlled by two, two way switch ( switch to be measured and paid separtely) |
| 10 | (c)One 3 pin socket outlet 5 hole 5 Amp independent in existing conduit with insulated stranded copper conductor cable 1.5 Sqmm single core and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 1.5 Sqmm stranded conductor as earth wire connected to dolly complete ( socket and switches to be measured and paid separately) |
| 11 | (d)-ditto- as above item No 6 (a) but Same board. |
| 12 | M&L One power point in existing conduit with insulated stranded copper conductor cable 4 Sqmm single core and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to dolly complete ( socket and switches to be measured and paid separately) |
| 13 | M&L One power point in existing conduit with insulated stranded copper conductor cable 2.5 Sqmm single core and PVCinsulated FRLS 1100 Volts unsheathed copper conductor 2.5 Sqmm stranded conductor as earth wire connected to dolly complete ( socket and switches to be measured and paid separately) |
| 14 | M & L for One 3 pin socket outlet, 5 Amps, independent,with cables 1.5 sq. mm size PVC insulated and unsheathed cable 1.5 sq mm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 all as specified including PVC insulated and unsheathed cable 1.5 Sqmm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 of green colour asearth wire to common earth and connected to earth dolly drawn in sameconduit on surface of wall/ceiling in PVC conduit pipe/casing & caping with saddle and nut,screw with high strength PVC end terminal box and cover sheet to mount one piano type 5 Amp switch and 3 pin 5 Amp socket as required complete. Note: switch & socket to be measured and paid separately. |
| 15 | M & L for One 3 pin socket outlet, 15 Amps, independent,with cables 2.5 sq. mm size PVC insulated and unsheathed cable 2.5 sq mm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 all as specified including PVC insulated and unsheathed cable 2.5 Sqmm (nominal area) multi stranded copper conductor single core Conforming to IS : 694 of green colour asearth wire to common earth and connected to earth dolly drawn in sameconduit on surface of wall/ceiling in PVC conduit pipe/casing & caping with saddle and nut,screw with high strength PVC end terminal box and cover sheet to mount one piano type 15 Amp switch and 3 pin 15 Amp socket as required complete. Note:switch & socket to be measured and paid separately. |
| 16 | Supply and fix in repair switch piano flush type 5 Amp SP one way complete all as specified and directed. |
| 17 | Supply and fix in repair switch piano flush type 5 Amp SP two way complete all as specified and directed. |
| 18 | Supply and fix in repairswitch piano flush type 15 Amp SP one way complete all as specified and directed. |
| 19 | Supply and fix in repairsocket outlet 5 pin 5 Amp flush type complete all as specified and directed. |
| 20 | Supply and fix in repairsocket outlet 2 in 1,3 pin 5/15 Amps complete all as specified and directed. |
| 21 | Supply and fix in repairceiling rose 3 phase PVCpolycorbonate,insulated body complete all as specified and directed. |
| 22 | Supply and fix in repairswitch type normal electronic fan regulator 5 stepcomplete all as specified and directed. |
| 23 | Supply and fix in repairbell push,flush type,5 amp complete all as specified and directed. |
| 24 | Supply and fix in repairbell ding dong AC,230 volts,single pole complete all as specified and directed. |
| 25 | Supply and fix in repairinsulated body pvc , angle holder (metal ring) B22 type ISI marked complete all as directed. |
| 26 | Supply and fix in repairswitch Modular type 6 Amps one way 230V AC as per sample complete all as specified. |
| 27 | Supply and fix in repairswitch Modular type 16 Amps one way 230V AC as per sample complete all as specified. |
| 28 | Supply and fix in repairModular socket outlet 5 pin 6 Amp socket 2 module as per sample complete all as specified. |
| 29 | Supply and fix in repairswitch bell push Modular type 6 Amps 1W-1 module, 230V AC as per sample complete all as specified. |
| 30 | Supply and fix in repairModular socket outlet 5 pin 16 Amp socket 2 module as per sample complete all as specified. |
| 31 | Supply and fix in repairModular fan regulator 1 module as per sample complete all as specified. |
| 32 | Supply only in replacement 12 MODULE plate suitable for modular switch and socket in white colour. Make:- INDOASIAN/LEGRAND/ANCHOR |
| 33 | Supply only in replacement 8 MODULE plate suitable for modular switch and socket in white colour. Make:-INDOASIAN/LEGRAND/ANCHOR |
| 34 | Supply only in replacement 6 MODULE plate suitable for modular switch and socket in white colour. Make:-INDOASIAN/LEGRAND/ANCHOR |
| 35 | Supply only in replacement 4 MODULE plate suitable for modular switch and socket in white colour. Make:- INDOASIAN/LEGRAND/ANCHOR |
| 36 | Supply only in replacement 3 MODULE plate suitable for modular switch and socket in white colour. Make:- INDOASIAN/LEGRAND/ANCHOR |
| 37 | Supply only in replacement 2 MODULE plate suitable for modular switch and socket in white colour. Make:- INDOASIAN/LEGRAND/ANCHOR |
| 38 | Refixing of Ceiling fan / exhaust fan/ fresh air/ Wall mounted fanincluding taking down after necessary repairs/ replacement of unserviceable/ wornout part and testing the same as per entire satisfaction of Engr-in- Charge complete all as specified and directed.Note- Spare Parts shall be measured and paid separately under relevant item of supply only. |
| 39 | M&L for opening up the winding of ceiling fan 1200/1400 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Teating of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge. |
| 40 | Supply only gun metal bush of any size and make sutiable for ceiling fans 1200/1400 mm compete all as specified and directed. |
| 41 | Supply onlyball bearing No. 6202, |
| 42 | Supply onlyball bearing No. 6203, |
| 43 | Supply only worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as directed. |
| 44 | S&F Ceiling fan blade suitable for 1200mm sweep of any make with suitable size as per site requirement complete all as specified and directed.(As per sample) |
| 45 | S&F Ceiling fan blade suitable for 1400mm sweep of any make with suitable size as per site requirement complete all as specified and directed.(As per sample) |
| 46 | M&L in replacement Fan Condenser of capacity 2.5/3.5 mfd, 220 Volts, AC 50 Hz, plastic-casing, two terminal-copper wire, complete all as specified and directed. |
| 47 | M&Lin replacementCondenser of capacity 1.0/1.5 mfd, 220 Volts, AC 50 Hz, plastic-casing, two terminal-copper wire, for exhaust or ventilating fan complete all as specified and directed. |
| 48 | M&L in replacement louvr shutter of exhaust fan suitable for 250/300 mm size at the height from 3mtr to 6 mtr heightmaking good surface of distubed area complete all as specified & directed.Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed. |
| 49 | Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as directed. Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only. |
| 50 | Supply only base plate assembly (confirming to ISI ) complete for25/35 Ltrs capacity copper tankgeyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusiveofclamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site as directed. |
| 51 | S&F of thermostat for 25/35/50 ltrs capacityof geysers complete all as directed. Make-THEETA/Elcon/USHA |
| 52 | S&F heating element of 2/1.5 KW triangular type with nut bolt washercomplete all as directed. |
| 53 | M & L non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed. |
| 54 | M&L forsafety pressurevalve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge. |
| 55 | M & L chromium plated copper connection pipe 60 Cm long with two brass adopters and connecting up complete all as directed. |
| 56 | Supply only inner still tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as directed |
| 57 | M&L in repair MCB distribution board SPN8 way with 200 Amp rated bus bar double door complete all as specified and directed. |
| 58 | Supply and fixMCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete. |
| 59 | Supply and fix in repair Modular type AC/GEYSER BOXsingle pole and Neutral with a two pin earth plug and socket complete with a mini MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed. |
| 60 | Supply and fixingin repair amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 61 | (i) SP 5 To 63 AMP |
| 62 | (ii) SPN 40 to 63 AMP |
| 63 | Supply and fixing in repair 415V 10KA \"C\" curve miniature circuit breaker (MCB) TPN 100 AMP 4 pole complete all as specified and directed. |
| 64 | Taking down carefully sub main wiringthree single run 6/10 Sqmm of any make and type complete all as directed. |
| 65 | Supply and fix in repair for submain wiring with two single core PVCinsulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 6 Sqmm size stranded conductor as earthwire. |
| 66 | Supply and fix in repair for submain wiring with two single core PVCinsulated FRLS 1100 Volts unseathed stranded copper conductor cable 10 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 10 Sqmm size stranded conductor as earthwire. |
| 67 | M&L in replacement distribution board VTPN 4 way load line DBs IP 43-IK 09 With metal door with provision of MCCB 125 Amp incomer and including 200 Amp rated bus bar,415 Volts and also Iincluding outgoing SP/TP MCBs 12 nos.Note:- Mccb/Mcb shall be measured and paid separately. |
| 68 | Supply and fix in repair MCCB 100 Amps, 4 Pole 415 volts 16 KA 50 HZ complete all as specified and directed. |
| 69 | Supply and fix in repair MCCB 125 Amps, 4 Pole 415 volts 16 KA 50 HZ complete all as specified and directed. |
| 70 | Supply and fix in repair MCCB 250 Amps, 4 Pole 415 volts 25 KA 50 HZ complete all as specified and directed. |
| 71 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover sinle phase 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. |
| 72 | M&L in repair of earthing complete with GI steel earth plate electrode 60cm x 60cmx6.0mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI strip 32x6mm by means of nuts, bolts checks nuts and washers made of GI earth wire protected by GI pipe 40mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 using 20mm graded aggregate, pre-cast RCC (1:2:4) type-B, over slab 30cmx30cmx10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 3 of MES schedule Part-I and testing after completion. |
| 73 | Supply and fix in repair , 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC armoured,PVC sheathed 6 sq. mm nominal cross section, 2 core. |
| 74 | M & L forin replacement onlysingle core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 75 | M & Lin replacement foronlysingle core PVC insulated cable2.5Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 76 | M&L in replacement copper cable flexible 3 corePVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge. |
| 77 | M&L in replacement copper cable flexible 3 corePVC insulated of size 40/.0076 ll as specified and directed by Engr-in-Charge. |
| 78 | Supply and fix in repairhylum sheets 3 mm thick (ISI marked) of the following sizes :- |
| 79 | (a) Sheet as per sample suitable for mounting one piano switch 5Amp and one 5Amp socket dully cut for mounting as above complete all as specified and directed. |
| 80 | (b) Sheet as per sample suitable for mounting one piano switch 15Amp and one 15Amp socket dully cut for mounting as above complete all as specified and directed. |
| 81 | (c) Sheet as per sample suitable for mounting thre piano switch 5Amp dully cut for mounting as above complete all as specified and directed. |
| 82 | (d) Sheet as per sample suitable for mounting four piano switch 5Amp and one 5Amp socket dully cut for mounting as above complete all as specified and directed. |
| 83 | (e) Sheet as per sample suitable for mounting five piano switch 5Amp and one 5Amp socket dully cut for mounting as above complete all as specified and directed. |
| 84 | Supply and fix in repair LED batten luminaire surface mounted 2 feet system wattage of 10 watts and system lumen ≥ 100 output, CRI >80, power factor >0.95, THD <10%, color temperature 3000K-6500K, IP-20 protected meetsLED IS specifications, short |
| 85 | Supply and fix in repair LED batten luminaire surface mounted 4 feet system wattage of 20 watts and system lumen≥1000 output, CRI >80, power factor >0.95, THD <10%, color temperature 3000K-6500K, IP-20 protected meets LED IS specifications, short c |
| 86 | Supply and fix in repairs decorative Wall light fittings suitable forLED bulb of 9/12 watt (B-22), including connection with all necessary fixing accessoriescomplete all as specified and directed by Engr-in-Charge. |
| 87 | Supply and fix in repair 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W ,Power Factor >0.95, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature 3000K-6500K, including connecting up with necessary PVC sheathed 3 core 1.5 Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 88 | Supply and fix in repair 40/45 watts High efficient LED Building Security light fitting with pressure die castAluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarie is >100lm/W .The color temperature is around 6500 K .The luminaire is IP:66 protected It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 150-270V.Complete as specified and directed. |
| 89 | S&F GI Pipe bracket bent to shape drilled welded made out of light grade GI pipe 25mm dia 1.5 mtr long and fixing on the wall where as directed by the Engr-in-Charge for fixing of building security light fitting including clamps, nuts, bolts and washers complete all as specified by the Engr-in-Charge . |
| 90 | Supply & fix in repair Slim Surface mounted round LED panel aluminium die cast body with premium diffuser to ensure glare free & even distribution of lights capacity 18/20 watts, 6500 K , Luminarie is >100lm/W complete with electric connection all as specified and directed by Engr-in-Charge. |
| 91 | Supply & fix in repair Slim Surface mounted round LED panel aluminium die cast body with premium diffuser to ensure glare free & even distribution of lights capacity 10/12 watts, 6500 K , Luminarie is >100lm/W complete with electric connection all as specified and directed by Engr-in-Charge. |
| 92 | Supply and fix in repairs LED bulb of 9 watt (B-22),with lumen >900 lm/W including dully connecting, fixing with all accessoriescomplete all as specified and directed by Engr-in-Charge. |
| 93 | Supply only exhaust fan motor capacity 1/4 HP 230 volts suitable for300/ 250 mm size exhaust /ventilating fan complete all as directed. |
| 94 | Supply only exhaust fan motor capacity 1/2 HP 230 volts suitable for450 mm size exhaust fan complete all as directed. |
| 95 | S & F hole fastner madeup of MS 4\" long with complete nut bolt all as specified.Make:as per sample |
| 96 | S &F exhaust fan 300 mm in replacement sweep metal typeincluding provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductorfrom ceiling rose to fan, length as per requirement at site. |
| 97 | Supply and fixingin replacement Ventilating Fan250 mm sweep, 1250 RPM, non metallic resin body,single phase 240 volts AC 50 Hzand connecting up completeall as specified and as directed. |
| 98 | S &F Wallfan in replacement 400 mm 3 bladein replacement sweep metal typeincluding provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor, length as per requirement at site. |
| 99 | Supplying, laying, jointing, testing and commissioning LT, XLPEinsulated armoured, heavy dutyaluminium conductor electric cable 1100 Volts grade, cross sectional area 16 Sqmm, 4 core including taking out old existing cable in trench/wall/pipes/surface as required and making cannection in LT Panels/Feeder etc complete all as specified and directed. |
| 100 | S&F in repairfor energy saving recess/surface mounted luminaire 36/40 W, incl LED Driver, high efficiency, Ultra modern designed LED Luminaire which provides soft- glare free light and symmetrical illumination, suitable for Armstrong/Grid ceiling of 600X600 mm, incl Provn ofthree core cable of copper conductor of size 1.5 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on ceiling including cutting, grooving with proper finish and making good, disturbed surface withallfixing arrangement complete all as directed. |
| 101 | Supply and Fix 80 W High efficient LED Flood light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70.The luminaire is IP:66 protected with IK05 impact resistance.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV for fixing the light fittings on Wall fixed complete as specified and directed. |
| 102 | Supply and fixing new generation, post top energy saving environmently friendly 25W , long life aesthetically designed with symmetrical light distribuiton spun aluminium landscape luminaire with high power LED as light sources. |
| 103 | M&L for servicing, descaling with descaling agents (chemical solvents) for removing all silt/rust of the solar water heater 500/1000 LPD capacity solar water heating system and making good any leakages, replacement of gaskets etc testing complete and making the plant functional including replacement of minor spares parts for complete system (rubber gaskets , flange dummy, flange brass, hose clamps of suitable sizes, descaling agent, glass rubber beedings etc.,) complete all as specified and directed. Note: Rates of minor spares are deemed to be included in quoted rate. |
| 104 | Ditto- all as per Item No. 89 here-in-before but solar water heater of capacity 100/125/200 LPD. |
| 105 | S & F in repair copper heating element for solar water system, 3kW, embedded copper, sheathed tubular with theremostat as per site requirement complete all as specified and directed. |
| 106 | Supply & Fix in Repair toughened glass of thickness 4mm suitable for solar hot water system, complete all as specified and directed. |
| 107 | M&L for taking down hot water tank 300/500 ltrs capacity and replacement of PUF insulation 50mm thick of 40 kg/cum density covered with SS 304 stainless steel cladding with 1mm thick sheet and refixing the same complete all as specified and as directed. |
| 108 | M&L for taking down hot water tank 50/100 ltrs capacity and replacement of PUF insulation 50 mm thick of 40 kg/cum density covered with SS 304 stainless steel cladding with 1mm thick sheet and refixing the same complete all as specified and as directed. |
| 109 | M&L for cylindrical type hot water tank of capacity 500 ltrs per day made of stainless steel sheet 1mm thick including insulation with PUF 50mm thick of 40 kg/cum density covered with SS 304 stainless steel cladding with 1mm thick sheet incl taking down old unsv tank complete all as specified and as directed. |
| 110 | M&L for cylindrical type hot water tank of capacity 300 ltrs per day made of stainless steel sheet 1mm thick including insulation with PUF 50mm thick of 40 kg/cum density covered with SS 304 stainless steel cladding with 1mm thick sheet incl taking down old unsv one, complete all as specified and as directed. |
| 111 | M&L for cylindrical type hot water tank of capacity 100 ltrs per day made of stainless steel sheet 1mm thick including insulation with PUF 50 mm thick of 40 kg/cum density covered with SS 304 stainless steel cladding with 1mm thick sheet incl taking down unsv one, complete all as specified and as directed. |
| 112 | Supply & Fix in Repair hose pipe (EPDM) size 25mm inner dia and 36mm outer dia suitable for solar hot water system complete all as specified and as directed. |
| 113 | Supply & Fix in Repair temparature gauge ISI marked dial type having range 0 to 100 ºC complete all as specified and as directed. |
| 114 | Supply & Fix in Repair water make up tank of 15 ltrs capacity made of 1.6mm thick mild steel sheet, painting 2 coats of synthetic enamel paint surface & inner surface shall be painted with 02 coat of black bituminous paint complete all as specified and as directed. |
| 115 | M&L for preparation of surfaces of Solar water heater plant of capacity 300/500 LPD, hot water tank, make up water tank, staging for hot/cold water tank, with different colors following the color code system or as directed by the site-in-charge. Job includes removing the old paint by rubbing, brushing and applying one coat of red oxide zinc chrome primer and two coats of Synthetic Enamel Paint (1st grade quality) complete all as specified and as directed. |
| 116 | All as per srl item No 101.00 here-in-before but solar water heater of capacity 100/200 LPD. |
| 117 | M&L for lagging to hot water pipes all round with nitryl rubber insulation 9mm thick with 26 SWG aluminium cladding system for open surface 15/20/25 mm bore pipe on roofs/walls of single/multistorey bldgs, complete incl taking down unsv one complete all as specified and as directed. |
| 118 | Supply & Fix in Repair solar plate collector flat type of capacity 100/125 LPD, including glass cover plate, aluminium collector housing, absorber, copper tubes, suitable insulation complete all as specified and as directed. |
| 119 | M&L for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as required of capacity 500 ltrs including makinginlet and outlet pipe connection and all accessories along with one PVC 20 mm bore float valve incl taking down old unsv one, complete all as specified and as directed. |
| 120 | S & F in repair 25 mm Gun-metal gate valves,with iron wheelhead, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 121 | S & F in repair 20 mm Gun-metal gate valves,with iron wheelhead, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 122 | S & F in repair 3 layer 15/16 mm nominal dia Hot PP-R polypropylene random copolymer pipes SDR 7.4 UV stabilsed and antimicrobial welded having thermal stability for hot & cold water suppy including all PP-R plain & brass threaded polypropylene random fittings fixed complete to wall, ceiling or in floors etc. with all fitiings like socket, reducer,bend etc.fixed complete all as specified and as directed. |
| 123 | Supply and fix in repair sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and as directed. |
| 124 | M&L for galvanised steel (Gl) tubing medium grade 25 mm bore with screwed socket joints, together with all tube fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc.), fixed complete to walls and ceiling or laid in floors including making connection with existing pipeline incl taking down old unsv one complete all as specified and as directed. |
| 125 | M&L for galvanised steel (Gl) tubing medium grade 20 mm bore with screwed socket joints, together with all tube fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc.), fixed complete to walls and ceiling or laid in floors including making connection with existing pipeline incl taking down old unsv one complete all as specified and as directed. |
| 126 | M&L for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as required of capacity 1000 ltrs including makinginlet and outlet pipe connection and all accessories along with one PVC 20 mm bore float valve incl taking down old unsv one, complete all as specified and as directed. |
| 127 | M&L for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as required of capacity 300 ltrs including makinginlet and outlet pipe connection and all accessories along with one PVC 20 mm bore float valve incl taking down old unsv one, complete all as specified and directed. |
| 128 | M&L for disconnecting all electrical and water connections from hot/cold water tank and reinstalling after fabrication work with MS angle iron, flats, plates, clamps including nuts, bolts, washers, welding, bending, drilling holes for bolts in any shape or size as indicated or directed for making staging of the hot/cold water tank including all civil wks including taking downold unserviceable one complete all as specified and as directed. |
| 129 | Dismantling the existing staging of the hot/cold water tank, collector plate of any capacity and type from the PCC foundation and material & labour for PCC 1:2:4 type B1 with (using 20mm graded stone aggregate) with 15mm thick rendering in CM 1:6 finished even and smooth with out using extra cement, grouting legs of staging, complete all as specified and as directed. |
| 130 | S & F in repair 15 mm PP-R Stop/ball valves, including fixing to pipeline as per site requirement, complete all as specified and as directed. |
| 131 | Supply & Fix in Repair PVC ball valves high pressure of PTMTwith epoxy coated Aluminiumrod& high density plastic ball, ISI marked, 15mm bore complete assembly screwed for iron pipe and fixed, complete all as specified and as directed. |
| 132 | S&F in replacement fully automatic star delta starter suitable for motor of capacity 5 HP including contactors, timers, relays etc. including connections with suitable size of copper wire, complete all as specified and as directed. |
| 133 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area6 sq. mm, three core, incl taking down old unsv wiring of any size and type complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail