| 1 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep in any type of soil and getting out, etc complete all as specified and as directed |
| 2 | Excavation in trenches n. exc 1.5m wide and n. exc 1.5m in depth in hard/dense soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n. exc 10 Sqm onplan and getting, etc complete all as specified and as directed |
| 3 | Excavation in trenches not exc 1.5 M deep and 1.5 M width and getting out in soft or loose soil for foundation of poles (or) cable laying , etc complete all as specified and as directed |
| 4 | Returning filling in hard/dense soil including spreading levelling watering and well ramming in layers n. exc 25cm thick , etc complete all as specified and as directed |
| 5 | Excavation in post hole in hard/dense soil (or similar holes) each n. exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface, etc complete all as specified and as directed |
| 6 | Removing excavated material (Soils) to a distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point, etc complete all as specified and as directed |
| 7 | Removing excavated material (any type of soil) to a distance exc 100m but n. exc 200m and depositing where directed at a level n. exc 1.5m above the starting point, etc complete all as specified and as directed |
| 8 | M&L for hardcore of broken stone or boulders of gauge n. exc 63 mm deposited spread and levelled in layers n. exc 15 cm thick watered and rammed to a true surface, etc complete all as specified and as directed |
| 9 | M&L Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations or mass concrete, etc complete all as specified and as directed |
| 10 | M&L for cement concrete 1:2:4 type B1 (Using 20mm graded stone agrregate) as in foundation of posts, railing and similar work , etc complete all as specified and as directed |
| 11 | M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping, edging including necessary form work , etc complete all as specified and as directed |
| 12 | M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and settingin cement mortar 1:4, etc complete all as specified and as directed |
| 13 | M&L for hardcore of broken stone or boulders of gauge n. exc 63 mm deposited spread and levelled in layers n. exc 15 cm thick watered and rammed to a true surface, etc complete all as specified and as directed |
| 14 | Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement, etc complete all as specified and as directed |
| 15 | S&F for stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc of required size on the top of floor or the side of waist slab with suitable arrangement , etc complete all as specified and as directed |
| 16 | S&F mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe-410W, Gde-E-250 Quality-A), etc complete all as specified and as directed |
| 17 | S&F mild steel roof trusses (framed), trrussed, purlins, crane gantries, rails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E-250) quality-A, etc complete all as specified and as directed |
| 18 | M&L plain anodised aluminium flat section as in wind tie with GI self tapping screws, etc complete all as specified and as directed |
| 19 | M&L for seamless designed gypsum board false ceiling 12mm thick including for any sunk or raised moulding with 25mm long self drilling/ tapping screws having philipshead with joining compound and 48mm wide fiber tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flangeof 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm c/c intermediate channel 0.9mm thick having two equal flanges of 15mm suspended from soffit at approx 900mm c/c with GI cleats and steel expansion fasteners with and incl ceiling section ( not exc 1.2m length) of 0.55mm thick having kurled web of 50mm an flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting across the intermediate channel at 457mm c/c incl hangers 6mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete and finally applying two coats of oil bound distember with roller finish over a coat of chalk whiting primer cmplete all as specified and directed |
| 20 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, etc complete all as specified and as directed |
| 21 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, fixed with self tapping screws, etc complete all as specified and as directed |
| 22 | M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in path finish the top surfaces even and rough to receive top layer, etc complete all as specified and as directed |
| 23 | M&L for chequered cement concrete tiles of size 30cm X 30cm X 25mm thick with grey cement and pigments set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor over and including 20mm thick screed bed in CM 1:4, etc complete all as specified and as directed |
| 24 | M&L for 15mm thick plaster in CM 1:4 on fair face of concrete surface or brick walls finished even and smooth without using extra cement, etc complete all as specified and as directed |
| 25 | M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm, etc complete all as specified and as directed |
| 26 | M&L forapplying two coat of synthetic enamel paint over a coat of red oxide primer includingpreparation of new steel surfaces of any description over 10cm width or girth not otherwise described , etc complete all as specified and as directed |
| 27 | Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) , etc complete all as specified and as directed |
| 28 | M&L for heavy duty Non skid tiles of size 300x300x9mm thick or high dimension (except thickness) of any colour any design durastone, weather proof impact ressistant, abrasion resistant exterior tiles, as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:4, etc complete all as specified and as directed |
| 29 | M&L for non glazed ceramic coloured wall cladding tiles 9-10mm thick area of each tiles n. exc 0.18 Sqm as in vertical surface incl cutting the tiles for fixing on curved surfaces set and jointed in neat cement slurry and pointed with white or coloured cement over and including 10mm thick rendering or bedding layer of cement mortar 1:3 complete all as per sample kept in the office, etc complete all as specified and as directed |
| 30 | M&L for 18mm thick designed rubco hut rubber wood frame shutter for cupboard, WHB counter cupboard, wall with finish to match all adjoining surfaces including sanding and applying mixture offiller and NCD thinner (Sheenlac make), pasting chalk putty, applying sealer (Sheenlac make) and wall nut colour stainer and finally applying waxpol (Silicon make), etc complete all as specified and as directed |
| 31 | M&L for preparation of new/old wooden surfaces and applying melamine polish through the process of snading with wood sanding paper of size 60 & 80 and applying wood filler mixed with NCD thinner including applying wood putty on shabby/ nailing area and sanding with sand paper of size 120 and applying sealer and walnut colour stainer and sanding with sand paper of size 320 and melamine polishing with spray application and again sanding with 400 sand paper and finally applying silicon of make Waxpol with soft fine cloth for better shining and finishing, etc complete all as specified and as directed |
| 32 | Supply, laying, testing and commissioning of underground LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 2 x 10 sqmm (laid in terenches,ducts,pole,wall etc.), etc complete all as specified and as directed |
| 33 | M&L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLSH PVCinsulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealedin walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green incolour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :-Make of wire : Polycab/ Gloster/ Anchor/ Havells/ Finolex and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab.Note :- The unit rate quoted shall deemed to include the cost of following :-(a) GI metal flush box of minimum thickness of 1.6mm and modular cover plate with frame of any module complete.(b) Proper colour coding is to be followed as per IS specification.(c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement.(d) Cutting chases in wall/floor /beam/ceiling to be concealed conduit and making good the disturbed surfaces. |
| 34 | All as per item Sl No 33 above, but, for One light/fan point controlled by one modular switch 5 Amps one way, etc complete all as specified and as directed |
| 35 | All as per item Srl No.33 above ,but ,point wiring with 4.0 sqmm PVC FRLSH insulated multistranded copper conductor suitable for one 3 pin 16 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board, etc complete all as specified and as directed |
| 36 | All as per item Sl No 33 above, but,point wiring for 3 pin switch socket outlet , 6 Amps on same board, etc complete all as specified and as directed |
| 37 | All as per item sl No 33 above, but,point wiring for 3 pin switch socket outlet ,6 Amps on independent board, etc complete all as specified and as directed |
| 38 | S&Ffor switchmodulartype, 6 Amps1 module, 230 volts AC circuit , etc complete all as specified and as directed |
| 39 | S&F for switchmodulartype, 16 Amps 1 module, 230 volts AC circuit , etc complete all as specified and as directed. Make : Roma (Anchor)/ Legrand/ Havells |
| 40 | S&Ffor socket outlet modular type 1 way 6 Amps, 3 pin, flush type 230 volts AC circuit, etc complete all as specified and as directed |
| 41 | S&F Socketoutlet 2 in 1 modular type,3 pin, 6 and 16 Amp , universal , etc complete all as specified and as directed. Make : Roma (Anchor)/ Legrand/ Havells |
| 42 | M&L for Submain wiring complete with two runs (1P+1N) of4.0 sq mm single core 1100 V grade with stranded copper conductor cableusing proper colour coding Phase Red /Yellow /Blue, Neutral- black and earth- green in and incl rigid PVC concealed/surface conduit(ISI marked) incl all specials/ accessories etc and provision of PVC insulated FRLSHcopper conductor single core cable of same size but green incolour as continuous earthing wire, etc complete all as specified and as directed.NOTE for item No 38: Twor runs (1P+1N) of copper conductor, One run ofcopper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length. |
| 43 | S&F Sub main wiring with PVC insulated cable 2 single core 1.5 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red/Yellow/Blue, Neutral- black and earth- green in and incl rigid PVC conduitconcealed in wall/ on surface(ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 1.5 sq mm for earthcontinuity all , etc complete all as specified and as directed. |
| 44 | S&F Sub main wiring with PVC insulated cable 2 single core 2.5 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red/Yellow/Blue, Neutral- black and earth- green in and incl rigid PVC conduitconcealed/surface in wall/ on surface(ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 2.5 sq mm for earthcontinuity, etc complete all as specified and as directed. |
| 45 | Supply & fix Cable Junction Box of size 130 x 130 x 77, IP 66 (Grey) with integrated membranes / metric knockouts for cable entry of size 2.5 sqmm to 6 sqmm twin core with earth, Lighting Outgoing cable : 3C x 1.5/ 2.5 Sq.mm cable, Degree of protection: IP66, including terminals, Material : PC-GFS (polycarbonate), Weatherproof, resistant to weather influences , etc complete all as specified and as directed. Make : Hensel model No DK 0606 Gor equivalent to Sintex |
| 46 | Supply and fixing on piller, wall etc post top lentern of cap 9 watt (max)with lamp E27 type ,highlight the outdoors IP65 fixture ideal ,aluminium body black premium finish, etc complete all as specified and as directed Engr in charge. Make :- Philips model No 58175 or equivalent to Havells/ CG |
| 47 | S&F high performance street light luminaire of cap 80 watt having single die ceramic base high power LED light source, IP66 protection, housing with finless design and polycarbonate cover, etc complete all as specified and as directed. Make:- Luker Model No-LSTE080S or equivalent to Havells/CG /Philips |
| 48 | Supply and fixing ofLED floodlight of cap 150 watt (of any coloured as reqd) made up of pressure die cast aluminium housing with toughened glass and high power LEDs included driver along with mounting bracketincludingfixing on pole/ wall/ iron structure etc complete all as specified and directedMake: Luker Model No : LFLSL150NSG or equivalent model of /Philips/Havells/CG |
| 49 | M&L for street light mounting bracket made up of 32 mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of angle iron/flat iron of suitable size, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer complete, etc complete all as specified and as directed. |
| 50 | Supply & fix FRP pole box 140 x 140 x 95 mm (inside dimension) consisting of 1 No 50 A 4 pole connector and 1 No 6 A MCB SP (as required) mounted on channel including taking down the old/unserviceable junction boxes, etc complete all as specified and as directed. Make : SINTEX Cat No. GS-JB-1414 or equivalent |
| 51 | Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipeof size 40 mm (OD) x 32 mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection, etc complete all as specified and as directed. |
| 52 | S&FModular Ac Box With 20A DP MCB \"C\" Type, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top, 240 volts AC supply for air conditioner, flush mounting in the wall, etc complete all as specified and as directed. Make :- Anchor (Roma) model no 98492 or equivalent in Legrand /Crabtree |