| 1 | Excavation in trenches n.exc 1.5 M wide and n. exc 1.5 M depth and getting out in soft/loose soil getting out complete all as specified and as directed. |
| 2 | Excavation in trenches exc 1.5 M n. exc 3 M depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 3 m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Demolition and breaking up 150mm bore RCC / SGSW drain pipesincluding PCC packing under haunching against sides of pipe bed and complete PCC bed and removal of debris to a distance exceeding 1.5 Km but not exc. 5 Km as specified and as directed. |
| 4 | Demolition and breaking up 200mm bore RCC / SGSW drain pipesincluding PCC packing under haunching against sides of pipe bed and complete PCC bed and removal of debris to a distance exceeding 1.5 Km but not exc. 5 Km as specified and as directed. |
| 5 | Demolition and breaking up 100mm bore RCC / SGSW drain pipesincluding PCC packing under haunching against sides of pipe bed and complete PCC bed and removal of debris to a distance exceeding 1.5 Km but not exc. 5 Km as specified and as directed. |
| 6 | Demolition and breaking up 300mm bore RCC / SGSW drain pipesincluding PCC packing under haunching against sides of pipe bed and complete PCC bed and removal of debris to a distance exceeding 1.5 Km but not exc. 5 Km as specified and as directed. |
| 7 | Material and Labour for salt glazed stone ware pipes of 150 mm grade A, laid in trenches and jointed complete all as specified and as directed. NOTE: Earth work shall be measured and paid separately. |
| 8 | Material and Labour for salt glazed stone ware pipes of 100 mm grade A, laid in trenches and jointed complete all as specified and as directed. NOTE: Earth work shall be measured and paid separately. |
| 9 | Supply and laying Reinforced cement concrete hume pipes class NP2, laid and jointed complete with one collar per length of pipe, dia 200 mm complete all as specified and as directed. |
| 10 | Supply and laying Reinforced cement concrete hume pipes class NP2, laid and jointed complete with one collar per length of pipe, dia 300 mm complete all as specified and as directed. |
| 11 | Material and labour for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation and mass concrete complete all as specified and as directed. |
| 12 | Material and Labour for PCC 1:3:6, type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm dia pipe complete all as specified and as directed. |
| 13 | Material and Labour for PCC 1:3:6, type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 100mm dia pipe complete all as specified and as directed. |
| 14 | Material and Labour for PCC 1:3:6, type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm dia pipe complete all as specified and as directed. |
| 15 | Material and Labour for PCC 1:3:6, type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 300mm dia pipe complete all as specified and as directed. |
| 16 | Materialand Labour forplain cement concrete 1:2:4 type B1 using 20mm graded granite stone aggrgate as in coping, bed plate,and the like including weathering, slightly rounded or chamfered angles and throatingincluding use of necessary form work all as specified and as directed. |
| 17 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars or at any position and removal of debris from site complete all as directed. |
| 18 | Material and Labour for providing precast cement concrete type C1, 1:3:6 (20 mm graded stone aggregate) solid blocks exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed. |
| 19 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc including removal of debries out side MD land all specified and directed. |
| 20 | Material and labour for 15 mm thick renderingon brick/concrete surfaces in two layers in CM 1:4, finishing coat of 5mm thick using water proofing compound @3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directed.Note: Water proofing compound shall be measured separately. |
| 21 | Supply only integral water proofing compound all as specified and as directed. |
| 22 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding25 cm complete all as specified and as directed. |
| 23 | Removal of debris/malwa to a distance exc 1.5Km but n exc 5 Km and depositing out side the MD land and asdirected by Engr-in-charge. |
| 24 | Material and labour for preparation of new surfaces on wall and applying two coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistant, dirt resistant exterior paint of required shade(company depot tinted) with silicon additives @ 1.43 Litre/10 Sqm over and includingpriming coat of exterior primer applied @ 0.90 Litre per 10 Sqmover new surface complete all as specified and as directed. |
| 25 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 26 | Material and Labour for 75mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection, paving including finishing the surface even and fair including necessary formwork, Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed. complete all as specified and as directed. |
| 27 | Cleaning of sewage lines up to 100mm to 300mm dia pipe by rodding from one man hole to next man hole, washing thoroughly with fresh water and removing all sludges from the sewage lines including removing existing man hole covers and refixing properly after cleaning and disposal of sludges out side MD landcomplete all as specified and as directed. Note: The sludge/debris and other waste material obtained after cleaning the drains shall remove from defence land duly followed the instructions laid down by the local govt bodies and the quoted rate shall be deemed to be inclusive of the removal of sludge/debris. |
| 28 | Cleaning the blockages in floor trap, Nahani trap, Gully trap, WC \"P\" trap or \"S\" trap, and refixing the same after cleaning of pipes up to 1st manhole making good damaged cement complete all as specified. |
| 29 | Cleaning of man holes of any size, and upto 1.5m depth by taking out cover slab of any size andbailing out foul water, by pumping out liquid sludge soil & sediments& disposing off out side MD land, cleaning the external surfaces with fresh water & fixing the manhole covers including disposal of sludges/water out side MD land complete all as specified and as directed. Note: The sludge/debris and other waste material obtained after cleaning the drains shall remove from defence land duly followed the instructions laid down by the local govt bodies and the quoted rate shall be deemed to be inclusive of the removal of sludge/debris etc. |
| 30 | Taking out RCC cover slab of septic tank of 50 to 100 users capacity carefully, taking out the sludge including foul water, collect the sludge in closed container andremove from defence land duly followed the instructions laid down by the local govt bodies. after complete removal of sludgeinlet and outlet pipe, M.S ring and septic tank complete cleaning with fresh water as directed and placing the RCC cover slab in position and set in CM 1:6 complete all as specified and directedNotes:- (i)The sludge/debris and other waste material obtained after cleaning the drains shall remove from defence land duly followed the instructions laid down by the local govt bodies and the quoted rate shall be deemed to be inclusive of the removal of sludge/debris etc.(ii) The rates quoted in the above item include the cost of T&P like Cleaning Rod, Bamboo spade, sewage Cleaning/Pressure Machine with loader etc complete. (iii) The lines measured once cannot measured again within 3 months. If blocks in the same lines re-occur within 3 months the contractor shall not be paid extra for the same. (iv) Minimum 2 persons shall be deployed by contractor and they shall be present on all days for attending the complaints of cleaning sewage/Blockage. The complaints shall be detailed by JE/AGE concerned. In case of non attending of complaints within 12 hours the recovery @ Rs 100 per complaint per day shall be made from contractors dues. (Date and time in Complaint Slip is only the criteria of recovery of non attending blockage complaint) (iv) Recovery made by Engineer -in-Charge will be final and binding for non attending sewage complaint. |
| 31 | Dismantling Stone slabs and interlocking tiles of any description or thickness in floors, aprons etc laid and bedded and pointed in any mortar all as specified and as directed. |
| 32 | Material and labour for 100mm thick plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregateas in sub base of floors including necessary form work all as specified and as directed. |
| 33 | Material and labour formachine pressed precast concrete interlocking paver block, any shape and size of 80 mm thickness M-40 grade conforming to IS 15658-2006 with grey cement and pigment laid over and including 50mm thick cushion of dry river sand, compacted with mechanical surface vibrator ,complete all as specified and directed. |
| 34 | Dismantling and refixing only of existingmachine pressed precast concrete interlocking paver block after levelling sunk portions with sand cushioning all as specified and as directed. Note: The rate quated is inclusieve of Sand for leveling/cushioning nothing extra shall be paid seperately. |
| 35 | Material and labour for chequered cement concrete tiles 300mm x 300mm x 25mm mixed with grey cement and pigment as in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match shade of tile laid over and including 20mm thick screed in CM 1:6 all as specified and as directed. |
| 36 | Material and labour in repair for roof tiles, Mangalore pattern, interlocking at side laiddry with and including one coat of exterior grade terracotta paint on tiled surface area complete all as specified and as directed.(Note: The rate quoted is inclusive of dismantling of roof tiles nothing extra shall not be paid separately.) |
| 37 | Material and labour in repair for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in CM 1:6 with and including one coat of exterior grade terracotta paint on tiled surface area complete all as specified and as directed.(Note: The rate quoted is inclusive of dismantling of roof tiles nothing extra shall not be paid separately.) |
| 38 | Supply and fixing in repair 10 ltrs capacity PVC low level flushing cistern white with inlet , float valve and handle including bracket with 32mm dia PVC pipe 600 mm long complete all as specified and directed by Engr-in-charge. |
| 39 | Supply and fixing in repairsVitrious China squatting pan \" Orissa\"pattern of size 580 mm x 440 mm white with integral foot rest excluding flushing cistern and flush pipe including P or S trap making good the floor to match with existing floor complete all as specified and as directed. |
| 40 | Supply and Fix in repairvitreous china wash down water closet Pedastal patternwhite (excluding flushing cistren ) including trap set, seat cover and fixing of flushing cistern, brackets, flushing pipeetc, etc. with\"P\" or \"S\" trap, making good the floor to match with existing floor complete all as specified and as directed. |
| 41 | S&F in repair 15 mm dia bore CP Bib cock, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipes or for union and fixed complete all as specified and directed by Engr-in-charge.Make;Gem/Shakti/Hindustan |
| 42 | Supply and fix in repair stop valves/angle cock, 15mm bore, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 43 | Supply and Fixing in repair stop valves/angle cock, 15mm bore, fancy type, with long shank & cut concealed typechromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 44 | S&Fin repair Brass CP Health Faucet, as Approved, including Taking down unserviceable Health Fosset of any description, complete as all specified and directed.Make;Gem/Shakti/Hindustan |
| 45 | Supply and fix in repairs vitreous china wash hand basin size 550 x 400 mm white, flat back with and including waste fittings brass chromium plated 32mm with long and fly nuts screwed shank excluding taps all as specified and as directed. |
| 46 | S&F in repair PVC connection 15 mm dia and 450 mm long with both end brass fly nutcomplete all as specified and directed by Engr-in-charge. |
| 47 | Supply and fix in repair 15 mm dia bore pillar taps swan neck cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or “cold’ with long screwed shank and fly nuts, screwed for iron pipe and fixed complete all as specified and directed by Engr-in-charge.Make;Gem/Shakti/Hindustan |
| 48 | S&F in repair 32 mm bore of pipe low density (LDPE) of pressure rating 6 Kg per Sqcm fixed to wall or floor etc including fittings complete all as specified and directed by Engr-in-charge. |
| 49 | Supply & Fixing in repair Brass chromium plated bottle traps 32mm for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed, complete all as specified and as directed. |
| 50 | Supply and fixing in repair 32mm dia waste coupling fitting brass chromium plated for basin with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engr-in-charge.Make Hindware/DK enterprises/Jinda plasticindustry |
| 51 | Supply and fix in repairBrass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified. |
| 52 | Supply and fixing in repairs5 mm thick bevelled edge looking mirror of size 600 x 450 mm mounted on 6 mm thick AC Building board or commercial plywood/hard board backing andfixed to wooden plugs with CP Screws and cup washersall as specified and as directed. |
| 53 | Supply and fix in repairs toilet paper holder of size 13 cm x 13 cm x 7 cm chromium plated of glossy finish fixed to wall with chromium plated brass screw complete all as specified and directed by Engr-in-charge. |
| 54 | Dismantling floor, hearth or wall tiling including cement mortar bedding and removing rubbish off the premises complete all as specified and as directed. |
| 55 | Material and Labour for non-skid coloured Ceramic tiles 7 to 8mm thick (square/rectangular)area of each tiles exceeding 0.11 Sqm but not exceeding 0.18sqm as on floors and jointed in neat cement slurry and in coloured cement to match, fixed over and including provision ofbedding layerof 15mm thick in CM 1:6 complete all as specified and directed. |
| 56 | Description all as per item No 55 .above but on vertical surfaces over 10 mm thick backing coat of cement mortar 1:4 complete all as specified and directed by Engr-in-charge. |
| 57 | Material and Labour for vitrified tiles 7 to 8 mm thick (square/rectangular) light coloured, area of each tile exceeding 0.18 sqm and not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed of 15mm thick in CM 1:6 complete all as specified and as directed.Note:- (i) The colour, shade and pattern shall be approved by the EIC during execution work. (ii) No extra cost shall be allowed for Removing and refixing and necesary cutting of door etcif any required during execution of work. |
| 58 | All as per Item No.57 above but for vertical surface/skirting, dados and risers to steps etc... over and including backing coat/rendering of 10mm thick in CM 1:4 complete all as specified and directed. |
| 59 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as directed. |
| 60 | Supply and fix in repair Mild steel angle iron in brackets including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 61 | Supply and fix in repair Welded steel wire fabric Weight exceeding 3.5kg but not exceeding 4 Kg per square metre , fixed towood or steel members complete all as specified and as directed. |
| 62 | Material and labour for applying two coats of synthetic enamel paint over one coat ofred oxide primer on new steel surfaces over 10 cm wide or girth including preparation of surface etc., complete all as specified and directed. |
| 63 | Supply and fix in repairs PVC (SWR) Pipes 75mmdia single socket in any length with rubber ring joint fixed to wall, jointing with Solvent Cement and fixed-in-repairs,including taking down the existing unserviceable pipe including solvent complete all as specified and directed by Engr-in-charge |
| 64 | Supply and fix in repairs PVC (SWR) Pipes 110 mmdia single socket in any length with rubber ring joint fixed to wall, jointing with Solvent Cement and fixed-in-repairs,including taking down the existing unserviceable pipe including solvent complete all as specified and directed by Engr-in-charge |
| 65 | Supply and Fix in repairs75mm dia PVC bendincluding solvent complete all as specified and directed by Engr-in-charge. |
| 66 | Supply and Fix in repairs110 mm dia PVC bendincluding solvent complete all as specified and directed by Engr-in-charge. |
| 67 | Material and labour for Cutting salt-glazed stoneware drain pipe in position of dia less than 300mm, including jointing socket end of new pipe to same with packed spun yarn and cement mortar 1:1 includingremoving and replacing manhole covers and temporarily plugging drains as requiredcomplete all as specified and directed. |
| 68 | Taking down existing unserviceable water tank after disconnecting water supply line and Supply and fix 500 litres capacity tripple layer, rotational molded, polythene water storage tank with cover (Cylindrical vertical with closed top),colour white ,hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etccomplete all as specified and as directed. |
| 69 | Supply and fixing in repair ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed suitable for 25 mmISI marked and taking down unserviceable ball valves all as specified and as directed. |
| 70 | Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed. |
| 71 | Demolition of reinforced cement concrete of any description ad in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 72 | Material and labour for Precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregateas in cover slabs of man holes including necessary form work, placed in position, set in CM 1:4 complete all specified and as directed. |
| 73 | Material and labour for TMT bars(CRS/HCR), 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed. |
| 74 | Material and Labour for TMT(CRS/HCR) bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9 mm dia or secured with clips complete all as specified and as directed. |
| 75 | Supply and Fix in repair concertina coil of 600 mm outer dia made out of 2.60mm dia spring steel wire 230gm (2min) dipped with corrosion preventive fluid(rusilo 901)of castrol make incl white colour,and an average weight not less than 8.57 kg (plus or minus 5%) including handle and spike at both ends of coil errected in position on top of mild steel angle by fixing with MS rod for securing incl necessary welding to MS sections etc including taking out old concertina complete all as specified and directed. |
| 76 | Supply and fix in repairs Galvanized, 2 strand, steel barbed wire 2.24 mm dia, barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including secruing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc. complete all as specified and directed. (each line wire to be measured) |
| 77 | Note for Items 27to 30:- (i) The rates quoted include the cost of T&P like Cleaning Rod, Bamboo spade, sewage Cleaning/Pressure Machine with loader etc complete. (ii) The lines measured once cannot measured again within 3 months. If blocks in the same lines re-occur within 3 months the contractor shall not be paid extrafor the same. (iii) Minimum 2 persons shall be deployed by contractor and they shall be present on all days for attending the complaints of cleaning sewage/Blockage. The complaints shall be detailed by JE/AGE concerned. In case of non attending of complaints within 12 hours the recovery @ Rs 100 per complaint per day shall be made from contractors dues. (Date and time in Complaint Slip is only the criteria of recovery of non attending blockage complaint) (iv) Recovery made by Engineer -in-Charge will be final and binding for non attending sewage complaint. |
| 78 | Schedule of Credit (Minus) Rs.18155.00NOTE: Bidder shall insert credit amount of Rs. 18155.00 as ratein Green field under Col-13. |