| Sl. No. | Item Description |
| 1 | Demolition of brick work or stone boulder masonry, built in cement mortar including all quoins, arches, pillars etc.including removing of unserviciable material from site complete all as specified and directed. |
| 2 | Material and labour for brick work with sub class `B` bricks, old size,straight or curved on plan exc 6m mean radius built in cement mortar (1:6)complete all as specified and directed. |
| 3 | Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for key, scrubbingdown with water etc. and removing debrish from site complete all as specified and directed. |
| 4 | Material and labour for 10mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:6) andfinish the surfaceseven and smooth without using extra cement as in wall complete all as specified and directed. |
| 5 | Material and labourfor 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces with using water proofing coumpound (WPC) @ 200ml per 50kg bag of cement or as per manufacturers instructionand finish the surfaceseven and smooth without using extra cement as in wall complete all as specified and directed.Note : WPC will be measured and paid separately under respective item. |
| 6 | Material and labour for 10mm thick dubbing out plaster on irregular face of walls / ceiling and rough finished in cement mortar (1:4) and applying two coat of anti corrosive paint to exposed reinforcement and applying two coats of two component acrylic polymer-modified cementitious high performance coating as per manufacturer instruction including GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. including all laps, cutting complete all as specified and directed.(a) Anticorrosive paint and two component acrylic polymer-modified cementitious high performance coating will be measured and paid separately under respective item.(b) Cost for scaffolding shall be included in the quoted rates. |
| 7 | Material and labour for 10mm thick dubbing out plaster on irregular face of RCC Over head water reservior column/ beams/walls / ceiling and rough finished in cement mortar (1:4) and applying two coat of anti corrosive paint to exposed reinforcement and applying two coats of two component acrylic polymer-modified cementitious high performance coating as per manufacturer instructionincluding GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. including all laps, cutting and waste of RCC over head reservior height exc 10 M but n exc 20 M complete all as specified and directed.(a) Anticorrosive paint and two component acrylic polymer-modified cementitious high performance coating will be measured and paid separately under respective item.(b) Cost for scaffolding shall be included in the quoted rates. |
| 8 | Material and labourfor 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces with using water proofing coumpound (WPC) @ 200ml per 50kg bag of cement or as per manufacturers instructionand finish the surfaceseven and smooth without using extra cement to wall of RCC over head reservior height exc 10 M but n exc 20 M complete all as specified and directed.Note : (a) WPC will be measured and paid separately under respective item.(b) Cost for scaffolding shall be included in the quoted rates. |
| 9 | Material and labourfor 5mm thick rendering in cement mortar (1:3) on concrete surfaces with using water proofing coumpound (WPC) @ 200ml per 50kg bag of cement or as per manufacturers instructionand finish the surfaceseven and smooth without using extra cement to ceiling of RCC over head reservior height exc 10 M but n exc 20 M complete all as specified and directed.Note : (a) WPC will be measured and paid separately under respective item.(b) Cost for scaffolding shall be included in the quoted rates. |
| 10 | Material and labour for 5mm thick rendering onconcrete surfaces in cement mortar (1:3) andfinish the surfaceseven and smooth without using extra cement as in ceiling complete all as specified anddirected. |
| 11 | Supply only liquid water proofing compound complete all as specified and directed. |
| 12 | Supply only anti corrosive paint complete all as specified and directed.Make: -Apcolite Rust Shield PU Enamel brand of Asian Paints Ltd or equivalent brand of make Pidilite / Fosroc. |
| 13 | Supply only two component acrylic polymer-modified cementitious high performance coating complete all as specified and directed.Make: SmartCare Damp Block 2K brand of Asian Paints Ltd or equivalent brand of make Pidilite / Fosroc. |
| 14 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of acrylic washable distemper over a coat of alkali resistance primer complete all as specified and directed. |
| 15 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming one coat of exterior primer applied @ 0.90 litre/ 10 sqmcomplete all as specified and directed. |
| 16 | Material and labour for preparation of new plastered surfaces of walls/ ceiling and applying two coats of 100% premium acrylic emulsion paint (camouflage pattern) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming one coat of exterior primer applied @ 0.90 litre/ 10 sqmheight exc 10 M but n exc 20 M complete all as specified and directed.Note :- Cost for scaffolding shall be included in the quoted rates. |
| 17 | Material and labour for preparation of new plastered surfaces of ceiling and applying three coat of white wash completeall as specified and directed. |
| 18 | Material and labour for preparation of old decorated surfaces of walls and applying one coat of acrylic washable distemper complete all as specified and directed. |
| 19 | Material and labour for preparation of old decorated surfaces of walls and applying one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 0.715 litre/ 10 sqm complete all as specified anddirected. |
| 20 | Material and labour for preparation of old decorated surfaces of walls and applying one coat of 100% premium acrylic emulsion paint (camouflage patteren) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 0.715 litre/ 10 sqm complete all as specified anddirected. |
| 21 | Material and labour for complete removal of existing treatement on old decorated surfaces of walls/ceiling and applying two coats of 100% premium acrylic emulsion paint (camouflage pattern) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming one coat of exterior primer applied @ 0.90 litre/ 10 sqm including preperation of surfaceheight exc 10 M but n exc 20 M complete all as specified and directed.Note :- Cost for scaffolding shall be included in the quoted rates. |
| 22 | Material and labour for preparation of old decorated surfaces of wall and applying one coat of white wash complete all as specified and directed. |
| 23 | Material and labour for preparation of old decorated surfaces of ceiling and applying one coat of white wash complete all as specified and directed. |
| 24 | Material and labour for writing letters or figures / Numericals (Block, Roman, Italic or Indian) not exc. 30 cm high with synthetic enamel paint complete all as specified and directed. |
| 25 | Taking down chowkats or frames with shutters n.exc. 1.50 sqm each (without taking off shutters from the frames) complete all as specified and directed. |
| 26 | Taking down chowkats or frames with shutters exc. 1.50 Sqm but n.exc. 4.00 Sqm each (without taking off shutters from the frames) complete all as specified and directed. |
| 27 | Material and labour for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed. |
| 28 | Supply and fix factory made 30mm thick 2nd class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers and fitted to frame work/ chowkat complete all as specified and directed. |
| 29 | Supply and fix 30mm thick 2nd class hard woodGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers as specified in SSR Part I, Section 8, clause 8.24 (a)complete all asspecified and directed. |
| 30 | Supply and fix steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat of primer complete all as specified and directed. |
| 31 | Supply and fix steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat of primer complete all as specified and directed. |
| 32 | Supply and fix mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. conforming to Fe.290.Gde-E-165including one shop coat of primer complete all as specified and directed. |
| 33 | Material and labour for preparation of new wooden surfaces of any description exc 10 cm width or girthand applying two coats ofsynthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 34 | Material and labour for preparation of old painted wooden surfaces of any description over 10 cm width or girthand applying one coat ofsynthetic enamel paint complete all as specified and directed. |
| 35 | Supply and fix 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden/ aluminium / rubber beads, nails etc in square not exc 0.5 sqm in each pane complete all as specified and directed. |
| 36 | Supply and fix stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or nut bolt complete all as specified and directed. |
| 37 | Supply and fix in repair builder hardware for steel windows/ ventilators like left/right handles, stays, latches and projected type stays etc including required welding work or fixed with rivets/ nut bolts as required complete all as specified and directed. |
| 38 | Material and labour for welding in reapirs n.exc 2.5 cm in lengthand thickness of metal to be welded exc 6mm but n.exc 9mm thick complete all as specified and directed.Note : Scaffolding and necessary form work shall be deemed in item rate. |
| 39 | Material and labour for structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes including one shop coat of red oxide zinc chrome primer complete all as specified and directed. |
| 40 | Supply and fix structural steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing conforming to Fe-410 W (Gde E-250) quality-Aincluding one shop coat of red oxide zinc chrome primer complete all as specified and directed. |
| 41 | Material and labour for preparation of new steel surfaces of any description over 10 cm width or girthand applying two coats ofsynthetic enamel paint over a coat of red oxide zinch chrome primer complete all as specified and directed. |
| 42 | Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girthand applying one coat of synthetic enamel paint complete all as specified and directed. |
| 43 | Supply and fix 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified anddirected. |
| 44 | Demolition of cement concrete (un-reinforced) in ground floor and pavings n.exc. 15cm thickness (below or above ground level) and removing of unserviciable material from site works complete all as specified and directed. |
| 45 | Rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 46 | Material and labour for moorum/ red bajri filling in floors or pavings including spreading levelling water and well ramming in layers not exc 15 cm thick complete all as specified and directed. |
| 47 | Material and labour for hardcore of broken stone or boulder of gauge n.exc 63mm, deposited, spread and leveled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 48 | Material and labour for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate ) as in foundation, filling and mass concrete, foundation of post and DG set/ transformer complete all as specified and directed. |
| 49 | Material and labour for 75mm thick PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in plinth protection, laid in panels including finishing theconcrete surface even and smooth without using extra cement including forming costruction joint 30mm deep x 10mm wide filled with sealing compound of group \"A\" complete all as specified and directed. |
| 50 | Material and labour for 40mm thick PCC (1:2:4) type B-1 (using 20mmgraded stone aggregate) as in floor and finished the surface even and fair complete all as specified and directed. |
| 51 | Dismantling of stone slabs and tiles laid dry of any description or thickness in floors, aprons etc. complete all as specified and directed. |
| 52 | Material and labour for re-laying cement concrete paver block of any size as in footparth, parks, lawns, drive ways or light traffic parking etc.including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. Note- Serviceable paver block obtaintained from item No 51.00 shall be reused under this items. |
| 53 | Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 54 | Material and labour for providing, cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) in roof kerbs ormud stops, rounded or chamfered on edges of tile path/walls/columns complete all as specified and directed. |
| 55 | Material and labour for PCC (1:3:6) type C1 (using 20 mm graded stone aggregate ) as in foundation, flooring, sub base, paving, surface channels, drains complete all as specified and directed. |
| 56 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred /stopped endsetc complete all as specified and directed.Note:- Only inner girth shall be measuredforpayment. |
| 57 | Material and labour for greasing, oiling and resecuring with minor repair works to existing rolling shutters and making proper functionablecomplete all as specified and directed. |
| 58 | Supply and fix in repair safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 59 | Supply and fix in repair ball bearing for rolling shutters complete all as specified and directed. |
| 60 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 61 | Dismantling of fencing wire mesh of chain link or any type including removing of debris from site complete all as specified and directed. |
| 62 | Dismantling (wood, steel or RCC) posts or struts embedded in concrete, brick work masonry etc. any section, including taking out embedded portion and making good disturbed ground including removing of debris from site complete all as specified and directed. |
| 63 | Excavation in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus soil to a distance n.exc 50m and making good disturbed surface in soft/loose soil complete all as specified and directed. |
| 64 | Supply and fix mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including one shop coat of red oxide zinc chrome primer complete all as specified and directed. |
| 65 | Supply and fix mild steel screw bolts diameter of neck 11 to 15mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt n. exc 5cm long complete all as specified and directed. |
| 66 | Material and labour for mild steel round bars 10 mm dia as in tie bar of chain link fencing conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and directed. |
| 67 | Supply only chain link MS galvanisd fencing of any size complete all as specified and directed. Note:- Weight of chain link fence shall be ascertained through BOO as ordered by GE. |
| 68 | Fixing only chain link fencing including line wire, any mesh, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wires complete all as specified and directed. |
| 69 | Supply and fix in repair galvanised 2 strand, steel barbed wire 2.24mm dia. barbed with 2mm dia. barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified anddirected.NOTE: Each line wire to be measured for payment. |
| 70 | Material and labour for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1) (by weight) complete all as specified and directed. |
| 71 | Material and labour for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces complete all as specified and directed. |
| 72 | Demolition of cement concrete (un-reinforced) of any description and in any position including removing debris from site of work complete all as specified and directed. |
| 73 | Material and labour for PCC (1:2:4) type B0 (using 12.50 mm graded stone aggregate) mixed with water proofing compound @ 200 ml per bag of cement or as per manufacturer instruction as in levelling course to match undulation of roof, in coving, roof kerbs including benching or mud stops, rounded or chamfered on edges etc including necessary form work and finished the rough surface complete all as specified and directed.Note : WPC will be measured and paid separately under respective item. |
| 74 | Material and labourfor 5mm thick rendering in cement mortar (1:3) with using water proofing coumpound (WPC) @ 200 ml per bag of cement or as per manufacturers instruction on roof top while concrete is green to become integrated part of concrete padding layer and finish the surfaceseven and smooth without using extra cement complete all as specified and directed.Note : WPC will be measured and paid separately under respective item. |
| 75 | Complete removal of existing roof treatment in any layers and disposal of debris from sitecomplete all as specified and directed.Notes: - (a) The rates are inclusive of removal for any type of old water proofing treatement over RCC roof.(b) Bidders are advised to visit the site and ensure about site condition before quoting their rates.(c) Demolition of PCC padding shall be measured and paid saparately under respective items. |
| 76 | Material and labour for water proofing treatment to RCC roof surface comprising with the following course of treatment/specifications from bottom to top :- (a) Applying cold bituminous primer @ 0.30 liters per sqm confirming to IS 3384 over plastered surfaces of roof.(b) One layer of APP based polymeric membrane3mm thick, weight not less than 3.50 kgs per sqm, reinforced with non woven polyester matt central core fabric (weight not less than 160 GSM) and coated on both side with and including layer of APP modified bitumen and finished with and including micro-prefabricated heat fusible polythene film on both surfaces. (c) Applying one coats of hot bitumen 85/25 grade @ 1.20 kg per sqm over membrane surface.(d) Finally applying two coats of bituminous aluminum paint @ 0.10 ltrs per sqm per coat on top surface. |
| 77 | Note:-(i) The work shall be executed only through authorised applicator of manufacturer as approved by GE.(ii) Laying of APP based polymeric membrane shall be done by torch on method or as per manufacturers instructions. (iii) A minimum overlap of 150mm and 100mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instructions. Make of APP membrane:- Super Thermolay of M/s STP Ltd, Hyperplas of M/s IWL India Ltd, Hydrostop of M/s Tiki Tar Danosa (India) pvt ltd, , M/s FOSROC Chemicals, Smartcare APP membranes of M/s Asian Paints Ltd. |
| 78 | Supply and fix in repair cable duct tray trunking made up with MS/pre-galvanised stainless steel sheet along with interlocking fixing accessories to fix in of thickness 1.6mm as wall/roof/floor per IS-1079 suitable for industrial/commercial cable duct corrisive resistance of size 600mm(W)x100mm (H)x 1.5 m (L) ladder type load balanceing capacity 100Kg/m for 600W, open rung design and good ventilation solid bottom enclosed for dust and moisture protection complete all as specified and directed. |
| 79 | Supply and fix in repair duct cover plate cover plate made of GI sheet of size 600mmx600mmx1.6mm of conforimg to IS -277 corrosion resistance plate sheet provision of a handle for fixing /opening duct cover complete all as specified and directed. |
| 80 | Supply and laying of 40mm graded stone coarse agreegate including taking out old unserviceable existing aggregate complete all as specified and directed. |
| 81 | Supply and fix electrical insulation mat as per IS-15652/2006 of size 1 mtr X 2 mtr X 2.50 mm thick (suitable for upto 11 KV) complete all as specified and directed. |
| 82 | Supply and fix electrical insulation mat as per IS-15652/2006 of size 1 mtr X 2 mtr X 3 mm thick (suitable for upto 33 KV) complete all as specified and directed. |
| 83 | Supply and laying of 20mm graded stone coarse agreegate including taking out old unserviceable existing aggregate complete all as specified and directed. |
| 84 | Cutting out concrete blocks, slabs, brickwork or stone masonry (in alternate course), forming toothings for and bonding new work in mortar into old work, including material and labour for precast cement concrete (1:3:6) type C1 (using 20mmgraded stone aggregate) and set in cement mortar (1:4) in old work complete all as specified and directed. |
| 85 | Material and labour for earthing complete with copper earthplate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of galvanised iron steel,protected by GI pipe 40mm dia (medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 40 x 40 x 6cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion including taking down old existing unserviceable earthing set complete all as specified and directed.Note:- Strip upto 7.5m length including testing shall be included in quoted rates. |
| 86 | Material and labour for making glow sign board of size 1.00x 1.50 meter for E/M installations at different location, made of 2mm thick stainless steel andstainless steel frame of 50mm x 50mm hollow square section, stainless steel bar in all side including fixing arrangement of retro reflective sheet (encapsulated lens type) in white colour over the blue sticker, height exc. 100 mm but not exc. 150mm cut to size and paste on mild steel plate and paste on blue sticker which stick on stainless steel sheet as per manufacturer instructions and welded on two Nos 50 mm x 50mm hollow square section stainless steel of length 3.0 meter which fixed over PCC foundation with PCC type B1 (1:2:4) (using 20mm graded stone agregate) including taking down old unserviceable existing sign board complete all as specified and directed. |
| 87 | Material and labour for taking out and washing properly the old filter media by water pressure or any suitable method including re-loading the washed filter media into the iron removal filter vessel 20000 GPH flow capacity of size(2378 mm dia x 2044 mm overall height)/ 10000 GPH ( overall size 1751mm dia x 2200 mm overall height) i.e graded gravelsand sand including complete removal of existing treatement of internal surface of iron removal plant and applying two coats of black bitumen paint complete all as specified and directed. Location: Pump house No 2 & 4. |
| 88 | Taking out unserviceable filter media complete from pressure filterand depositing the same and removal of unserviceable materials to a distance n.exc 50m. The capacity and size ofpressure filter and oxidation chamber are as under:- |
| 89 | Pressure filter of capacity 20000 GPH (overall size 2378mm dia x 2044 mm overall height) and oxidation chamber of capacity 10000 GPH (overall size 1598mm dia x 1667mm overall height).Location:- Pump house No 2 & 4 |
| 90 | Pressure filter of capacity 10000 GPH (overall size 1751mm dia x 2200 mm overall height) and oxidation chamber of capacity 10000 GPH (overall size1019 mm dia x 1760 mm overall height).Location:- Pump house No 2 & 4 |
| 91 | Material and labour for filling and laying in different layers of new washed filter media of consisting gravels of different sizes and sand in to the pressure filter for following size :- |
| 92 | Treated green sand suitable for filter media of 16/32 mesh inside the pressure filter up to 6 layer from bottom. |
| 93 | Coarse sand suitable for filter media of 16/32 mesh inside the pressure filter up to 6 layer from bottom. |
| 94 | Gravels of size 1/8\" to 1/4\"for filter media. |
| 95 | Gravels of size 1/4\" to 1/2\" for filter media. |
| 96 | Gravels of size 1/2\" to 3/4\" for filter media. |
| 97 | Gravels of size 3/4\" to 1\"for filter media. |
| 98 | Gravels of size 1\" to 1½ \"for filter media.Note for item No 88.10 to 88.70:- Punned down thickness shall be measured for payments. |
| 99 | Supply and fix in repair PVC strainer tube for pressure filter as per existing shape and size complete all as specified and directed. |
| 100 | Supply and lay manganese di-oxide (MnO2) suitable for use in oxidation chamber and flow testing as per existing capacity complete all as specified and directed. |
| 101 | Material and labour for cleaning and washing properly the old catalyst (MnO2) by water pressure or any suitable method and drying including loading the media into the oxidation chamber and testing complete all as specified and directed. |
| 102 | Material and labour for dis-connecting the centrifugal pump set of capacity 5HP to 10 HP and repair, rewinding with good qualitymotor varnishing winding to improve the insulation capacity and refixing the pump set after repair and overhauling complete all as specified and directed.Note: Spares shall be measured and paid separately under respective items as supply only. |
| 103 | Supply only bearing of existing make and capacity. |
| 104 | Supply only Gasket set of existing make and capacity. |
| 105 | Supply only coupling of existing make and capacity. |
| 106 | Supply only fan blade of existing make and capacity. |
| 107 | Supply only CI Impeller of existing make and capacity. |
| 108 | Supply only Copper winding wire of existing guage. |
| 109 | Material and labour for repair, servicing, and overhauling of Altoc dozing pump 10kg/sqcm capacity and replace the unserviciable parts and refixing the pump after repair and overhauling complete all as specified and directed.Note: Spares shall be measured and paid separately under respective items as supply only. |
| 110 | Supply only spacer of existing size. |
| 111 | Supply only spacer spring of existing size. |
| 112 | Supply only pump housing of existing size. |
| 113 | Supply only Solenoid coil body of existing size. |
| 114 | Supply only Pulsar circuit of existing size. |
| 115 | Supply only Anti siphon valve of existing size. |
| 116 | Supply only Anti siphon spring of existing size. |
| 117 | Material and labour for repair and rewinding and overhauling of Altoc dozing motor of 10kg/sqcm capacity and replacement of theunserviceable parts and refixing the motor after repair and overhauling complete all as specified and directed.Note: Spares shall be measured and paid separately under respective items as supply only. |
| 118 | Supply only pump tube of existing size. |
| 119 | Supply only injection check valve of existing size. |
| 120 | Supply only duck bill of existing size. |
| 121 | Supply only \"O\" ring of existing size. |
| 122 | Supply only copper wire of existing guage. |
| 123 | Material and labour for taking out burnt submersible pumping set of capacity 10 HPto 20 HP from bore well located at 6 Wing, Pump house No 2 and dis-connecting of electric cable from the panel board and dismantling 80 mm to100 mm dia CI/GI column pipe by using chain pulley arrangement complete all as specified and directed. Note : The quoted rate shall be included for transporation of pumping set from site to workshop and return to the site. |
| 124 | Material and labour for taking out the pump of 10 HPto 20 HPcapacity from the motor and opening of submersible pump for repair and replacement of unserviceable parts and refixing the pump after repair and testing complete all as specified and directed.Note: Spares shall be measured and paid separately under respective items as supply only. |
| 125 | Supply only pump head of existing size. |
| 126 | Supply only gun metal bowl bush of existing size. |
| 127 | Supply only CI impeller of existing size. |
| 128 | Supply only impeller bush of existing size. |
| 129 | Supply only discharge case bush of existing size. |
| 130 | Supply only oil seal of existing size. |
| 131 | Supply only shaft sleeve of existing size. |
| 132 | Supply only shaft nut of existing size. |
| 133 | Supply only sand guard of existing size. |
| 134 | Supply only stuffing box bearing of pump |
| 135 | Material and labour for rewinding of submersiblemotor of capacity 10HP to 20HP with super enameled copper wire including removing burnt winding, cleaning of slots separation of rotor and starter making insulation to all joint and replacement of unserviceable parts and refixing of motor and testing and commissioning complete all as specified and directed.Note: Spares shall be measured and paid separately under respective items as supply only. |
| 136 | Supply only bearing bush upper of existing size. |
| 137 | Supply only bearing bush lower of existing size. |
| 138 | Supply only balancing ring of existing size. |
| 139 | Supply only jointing kit of existing size. |
| 140 | Supply only oil seal of existing size. |
| 141 | Supply only gun metal rotor housing bush of existing size. |
| 142 | Supply only super enamelled copper winding wire of existing guage. |
| 143 | Supply and fix in repair stuffing boxshaft with stud holes of motor of capacity 10HP to 20HP of existing size complete all as specified and directed. |
| 144 | Supply and fix in repair open type impeller made of CI suitable for motor of capacity 10HP to 20HP of existing size complete all as specified and directed. |
| 145 | Material and labour for lowering of the submersible pumping set of 10HP to 20HP into bore well by using the chain pulley arrangement with fixing of column pipe of size 80mm to 100mm dia, including nut, bolts, washers, and rubber gasket in replacement and tightening of submersible cable with pipe and connected of submersible cable from existing panel board. complete all as specified and directed. |
| 146 | Supply and fix in repair direct-on-line startersin sheet-steel enclosure type MKI for motor rating 7.5 HP , AC-3 duty, 415V, 50Hz suitable for three phase supply complete all as specified and directed. |
| 147 | All as per item No 101.00 here-in-before butof capacity 10 HP and -ditto-. |
| 148 | All as per item No 101.00 here-in-before butof capacity 15 HP and -ditto-. |
| 149 | All as per item No 101.00 here-in-before butof capacity 20 HP and -ditto-. |
| 150 | Material and labour for servicing and overhauling/repair of parts of air compressor of 5HP capacity vessel cylindrical in shape after dismantling it from its position, drying up of cylinder by de-watering complete system and washing with anti scalant chemical with the help of external compressor of 10Kg pressure, filling up of oil in its cylinder head after opening the head and re-fixing it including testing complete with existing system complete all as specified anddirected.Note: Spares shall be measured and paid separately under respective items as supply only. |
| 151 | Supply only compressor valves of existing size. |
| 152 | Supply only bearings of existing size. |
| 153 | Supply only backup ring of existing size. |
| 154 | Supply only pressure breaker for radial ring of existing size. |
| 155 | Supply only tangent ring of existing size. |
| 156 | Supply only gasket of existing size. |
| 157 | Supply only DOL starter 5HP 3 Ph, 415 V including relay and contactor. |
| 158 | Supply and fix 3 core flat copper cable, PVC insulated, PVC sheathed for submersible pump set 1100 volt 16 sqmm size includin taking down the old unserviceablecable complete all as specified and directed. |
| 159 | All as per item No 106.00 here-in-before butof size 10 sqmm and -ditto-. |
| 160 | Supply and fix in repair pressure gauge suitable for bearing pressure upto 20 Kg/sqcm complete all as specified and directed. |
| 161 | Material and labour for cleaning once in a month by spraying of weeds herbicide for kill unwanted vegetation around near E/M installation, cutting grass, removing unwanted bushes, removing debris etc and making good of undulated ground by filling fresh soil and levelling the area to existing ground level, removing unwanted debris from thesite complete all as specified and directed. Note:-(i) Location - Pump house No 1 to 4 and total approx area - 1600.00 sqm.(ii) In case of damage to any existing assets such as UG cables, pipelines or any type of things, contractor shall be make good as per the existing without any extra cost.(iii) Cleaning in pump house No 1 to 4 shall be considered as one job for payment purpose. |
| 162 | - ditto- all as per Ser item No 109.00 here in before but inLocation - Sub station No 1 to 4 and total approx area - 1200.00 sqm and -dittio-.Note:- Cleaning in Sub station No 1 to 4 shall be considered as one job for payment purpose. |
| 163 | Supply only Trichloro Isocyanuric Acid (TCCA) having 90% available chlorine complete all as specified in Generic Specification mentioned in Particular Specification of Tender Documents as Appendix- \"A\". |
| 164 | Supply only Ferric alum complete all as specified in Generic Specification mentioned in Particular Specification of Tender Documents as Appendix- \"B\".Note for item No 111.00 & 112.00 :- (i) The contractor shall produce original purchase voucher with manufacturer\"s test certificate mentioning date of manufacturing, batch No, date of expiry of materials etc before releasing payment.(ii) The contractor shall also produce test certificate from GOVT / NABL accredited labs to confirm Generic Specification as mentioned in Particular Specification of Tender Document. |
| 165 | Supply only crystal alum complete all as specified and directed. |
| 166 | Labour only to attend breakdown of motor starter panels to repair the contactor terminals, push bottons, cable joint terminals, connector terminals, repairing all kind of wiring of DOL / automatic star delta starter ranging from 5HP to 20HP capacity, minor repair of single phase preventor, phase sequenzer, delay timer, relay, R-Y-B indicators, minor repair of Ammeter and Volt meter etc, replacement of burnt out PVC insulated copper wire, copper thimble, re-connect the same after thoroughly clean and testing complete all as specified and directed. Note: Spares shall be measured and paid separately under respective items as supply only. |
| 167 | Supply only contactor of capacity 25 Amp, 3 pole, 415 volt, Type MNX 22 Including auxilary contact block 1 NO & 1 NC complete all as specified and directed. |
| 168 | Supply only thermal overload ralay of range 28-40 Amp complete all as specified and directed. |
| 169 | Supply only star delta timer adjustable type from 3 to 120 sec complete all as specified and directed. |
| 170 | Supply only single phase preventor SPPR type of existing size complete all as specified and directed. |
| 171 | Material and labour for cleaning / flushing out mud of bore well after lifting of submersible pumsets of capacity 10 to 15HP including pulling out of column pipe upto full depth of all pipes of size 80mm to 100mm flanged type and cleaning of column pipes and replacing corroded out nut bolts of flanged column pipes of all flange joints and replacing rubber gasket of all defective joints, after dismantling all kind of electric and water supply connections, cleaning of bore well upto 100mtr or as per existing depth by using heavy compressor having pressure of 20Kg or above to flush out the muddy and dirty water with adequate pressure till the achievement of smell free water, cleaning of porous of wall by injecting dry air through compressor or by using compressor air blower, testing of TDS of water complete at site after lowering the pump motor sets and cable complete all as specified and directed. Location: Pump house No-04. |
| 172 | Material and labour for complete removal of existing treatement of old painted metallic surfaces of inner and outer body of iron removal plants, Catalyst/Oxidation chambers, Pressed steel Over Head Reservoirs, misc metallic surfaces over 10cm width or girth and applying two coats of anti corrosive synthetic enamel paint over a coat of metalic zinc chrome primer including preperation of surfaces complete all as specified and directed.Note:-(i) Necessary arrangement for ladder/scafolding/any other structure shall be arranged by the contractor. (ii) As the this nature of work involves Over Head Tank cleaning and painting, Contractor has to take adequate safety precautions while doin work on high staging. |
| 173 | Material and labour for construction of brick masonry valve pitof size 1200x1200x1200mm (internal dimension) with one brick thick PCC (1:4:8) type D-2 (using 40mm gradedstone aggregate) as in foundation concrete including PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in bedding and coping 10mm thick cement plaster incement mortar (1:4) internally and externally upto 15 cm below ground level providing valve pit 50x50x6mm angle iron frame all round the fixed point by means of 4 Nos hold fast 150mm long made out of flat iron 40 x 6 mm embedded in PCC block (1:2:4) type B-1 (using 20mm gradedstone aggregate) of size 230 x200 x100mm. including provision of hinges welded with angle iron frame and mild steel cover 3 mm thick, mild steel handle of suitable and size welded with mild steel cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red-oxide primer including necessary excavation work in soft/ loose soil including dismantling of unserviciable existing valve pit complete all as shown in Drawing No AF/TD/240/15 of sheet 1/2 & 2/2 and directed. |
| 174 | All as per item no 117.00herein before but size 900x900x900mm (internal dimension) and -ditto-. |
| 175 | Dismantling of multi-stage centrifugal Pump set electrically driven horizontal Split case (two stage) pump set for clear water, centrifugal type with CI Casing , bronze impeller andStainless steel shaftmounted on heavy duty bearings suitable for rated capacity for 60HP, 440 V , 3 Phase. 50 Hzand pump has minimum 81m Head, 1658 LPM minimum discharge centrifugal, electric driven, SprayPainting to MS base frame and refixing the same in existing position complete all as specified and directed.Make Kirloskar, Model-DSM 80/36.Note:- (i) Spares parts shall be measured and paid separately as supply only (ii) Quoted rate shall be included for transportation of pump to civil workshop and return back at site. |
| 176 | Supply only PUMP SHAFT, PART NO : 180 , MOC : C-40, FOR PUMP MODEL : DSM 80/36 |
| 177 | Supply only WEAR RING, PART NO : 190 , MOC : CI, FOR PUMP MODEL : DSM 80/36 |
| 178 | Supply only SHOULDER RING, PART NO : 199 , MOC : MS FOR PUMP MODEL : DSM 80/36 |
| 179 | Supply only INTERSTAGE RING, PART NO : 204 , MOC : CI , FOR PUMP MODEL : DSM 80/36 |
| 180 | Supply only GLAND , PART NO : 223 , MOC : CI , FOR PUMP MODEL : DSM 80/36 |
| 181 | Supply only LANTERN RING , PART NO : 227 , MOC :CI , FOR PUMP MODEL : DSM 80/36 |
| 182 | Supply only LIQUID DEFLECTOR , PART NO : 236 , MOC : NATURAL RUBBER, FOR PUMP MODEL : DSM 80/36 |
| 183 | Supply only BEARING HOUSING DE PART NO : 240 , MOC : CI , FOR PUMP MODEL : DSM 80/36 |
| 184 | Material and labour for repair and maint of star delta starter of 60 HP capacity after disconnecting of incoming / outgoing connection, checking the serviceability of all components i.eexisting contactors, over load relay, timer, single phase preventer, indicator lights, replacement of burnt out PVC insulated copper wire, copper thimble, re-connect the same after throughly cleaning and replace the following unserviceable parts complete all as specified and directed. NOTE : Spares shall be measured and paid separately under following items as supply only. |
| 185 | Supply only contactor of capacity 95 Amp, 3 Pole, 415 Volt, AC rating 3, Type MNX 95 including auxiliary contact block 1-NO &1-NC. |
| 186 | Supply only thermal overload relay of range 45-75Amp, MN-5 suitable for MNX type contactor. |
| 187 | Supply only star deltatimer adjustable type from 3 to 120 sec. |
| 188 | Material and labour for rewinding ( copper appx 9 Kg)of three phase induction motor 10 - 15 HP, 1470 RPM (Make- Kirloskar Brothers Limited) with super enameled copper wire including removing burnt winding cleaning of slots separation of rotor and starter making insulation to all joint and replacement of the unserviceable parts of motor and refixing, testing & commissioning complete all as specified and directed. Note:-(i) Spares shall be measured and paid separately as supply only.(ii) Quoted rate shall be included for transportation of pump to civil workshop and return back at site. |
| 189 | Supply only stator core |
| 190 | Supply only shaft turning with metalizing |
| 191 | Supply only cover housing |
| 192 | Supply only bearing as per existing |
| 193 | Supply only flange |
| 194 | Supply only coolen fan |
| 195 | Supply only fan cover |
| 196 | Supply only heat varnishing |
| 197 | Supply and fix in repair 15mm bore gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 198 | All as per item No 122.00 above but 20mm bore and -ditto-. |
| 199 | All as per item No 122.00 above but 25mm bore and -ditto-. |
| 200 | All as per item No 122.00 above but 40mm bore and -ditto-. |
| 201 | All as per item No 122.00 above but 50mm bore and -ditto-. |
| 202 | Supply and fix antiscallen chemical dozing pump suction and discharge NRV accessories as per existing size complete all as specified and directed. |
| 203 | Supply and fix foot valve of suitable size for existing dozing pump complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail