Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for key, scrubbingdown with water etc. and removing debrish from site complete all as specified and directed. |
| 2 | Demolition of brick work or stone boulder masonry, built in cement mortar including all quoins, arches, pillars etc.including removing of unserviceable material from site complete all as specified and directed. |
| 3 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided including removing of rubish from site complete all as specified and directed. |
| 4 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises complete all as specified and directed. |
| 5 | Dismantling of stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed. |
| 6 | Taking down chowkats or frames with shutters n.exc. 1.50 Sqm each (without taking off shutters from the frames) complete all as specified and directed. |
| 7 | Taking down chowkats or frames with shutters exc. 1.50 sqm but n.exc 4.00 sqm each (without taking off shutters from the frames) complete all as specified and directed. |
| 8 | Resecuring or easing and adjusting without taking down shutters for easy closing / opening, end tightening of butt hinges in position, adjustement of butt hinges in position, adjustement of existing iron mongry, size of shutter exc 1 sqm but n. exc 2 sqm each complete all as specified and directed. |
| 9 | Taking down chowkats or frames with shutters exc. 1.50 sqm but n.exc 4.00 sqm each (without taking off shutters from the frames) and refixing in same opening opening with using hold fast, minor cement concrete work and making good complete all as specified and directed. |
| 10 | Material and labour for 10mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:6) andfinish the surfacesfair and even on wall complete all as specified and directed. |
| 11 | Material and labour for 5mm thick rendering onconcrete surfaces in cement mortar (1:3) andfinish the surfaceseven and smooth without using extra cementin ceiling complete all as specified anddirected. |
| 12 | Material and labour for preparation of new plastered surfaces of walls and applying two coats of acrylic washable distemper over a coat of alkali resistance primer including applying 2mm thick wall care putty complete all as specified and directed. |
| 13 | Material and labour for preparation of new plastered surfaces of ceiling and applying three coat of white wash completeall as specified and directed. |
| 14 | Materials and labour for complete removal of existing treatment of old decorated surfaces of walls and applying two coats of acrylic washable distemper over a coat of alkali resistance primer including applying2mm thick wall care putty including preperation of surface complete all as specified and directed. |
| 15 | Material and labour for preparation of old painted wooden surfaces of any description over 10 cm width or girthand applying one coat ofsynthetic enamel paint complete all as specified and directed. |
| 16 | Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girthand applying one coat ofsynthetic enamel paint complete all as specified and directed. |
| 17 | Material and labour for preparation of old decoratedsurfaces of wall and applying one coat of white wash complete all as specified and directed. |
| 18 | Material and labour for preparation of old decorated surfaces of ceiling and applying one coat of white wash complete all as specified and directed. |
| 19 | Materials and labour for half brick thick brick work with sub class `B` bricks, old size, straight or curved on plan to any radius built in cement mortar(1:4) complete all as specified and directed. |
| 20 | Material and labour for well-seasoned 2nd class hard wood plain fillets, square, rectangular or triangular in section, wrought, secured with nails or brads, sectional area exc. 13 sqcm but not exc. 25 sqcm complete all as specified and directed. |
| 21 | Supply and fix powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed. |
| 22 | Supply and fix powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and directed. |
| 23 | Supply and fix in repair solid PVC wall lining consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC/Aluminium frame complete all as specified and directed. |
| 24 | Material and labour for second class hard woodsmall fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary\" labours; articles n. exc 200 cu. cm each complete all as specified and directed. |
| 25 | Supply and fix stainless steel 100mm size butt hinges, medium weight complete all as specified and directed. |
| 26 | Supply and fix 150 mm long aluminum anodised barrel tower bolts cast type complete all as specified and directed. |
| 27 | Supply and fix 100mm long aluminium handles, cast type, anodized complete all as specified and directed. |
| 28 | Supply and fix 300mm long aluminium alloy, anodised, sliding door bolts with hasps, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. |
| 29 | Supply and fix in repair 300mm long aluminium alloy, anodised, sliding door bolts with hasps, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. |
| 30 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 31 | Supply and fix 4 mm thick figured glass pin head type and glazing with oil putty in square n. exc 0.5 Sqm in each pane complete all as specified and directed. |
| 32 | Supply and fix stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 33 | Material and labour for ceramic, non skid coloured tiles (premium quality) 7 to 8mmthick (square/rectangular) area of each tile exceeding 0.18sqm but not exc. 0.38sqmas in skirting and dado set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick rendering in cement mortar (1:4)complete all as specified and directed. |
| 34 | Material and labour for glazed ceramic tiles of size 600x1200x8-9 mm (premium quality) coloured in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick cement plaster in cement mortar (1:3) completeall as specified and directed. |
| 35 | Material and labour for 25mm thick PCC (1:2:4) type B-0 (using 12.50mmgraded stone aggregate) as in levelling course for laying floor / roof finishes complete all as specified and directed. |
| 36 | Material and labour for 20mm thick jet black granite for top shelves (of any type) work (table rubbed and polished) in cupboard shelves, steps, jambs, window cills, cooking platforms and like in cement mortar (1:4) including pointing, grooving to wall etc with white cement using marble dust with admixture of pigment to match with shade of granite including moulding/nosing fixed independently complete all as specified and directed. |
| 37 | Material and labour for machine cut cudappah stoneslab 20-25mm thick as in shelf including rubbing and polishing complete including taking down existing shelf complete all as specified and directed. |
| 38 | Material and labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations completeall as specified and directed. |
| 39 | Taking up or down 15 mm bore steel tubing and connections, including removal from site complete all as specified and directed. |
| 40 | Taking up or down 20 mm bore steel tubing and connections, including removal from site complete all as specified and directed. |
| 41 | Supply and fix 15 mm bore steel tubesmedium grade, galvanised, with all fitting and fixed to walls, ceilings, roofs or laid in floorscomplete all as specified and directed. |
| 42 | Supply and fix 20 mm bore steel tubesmedium grade, galvanised, with all fitting and fixed to walls, ceilings, roofs or laid in floors complete all as specified and directed. |
| 43 | Material and labour for cutting chases, pinning in brick wall making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 44 | Supply and fix in repair 15mm bore stop valves, castcopper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed bothends for iron pipe or for unions complete all as specified and directed. |
| 45 | Supply and fix in repair 15 mm bore two way bib taps fancy type cast copper alloy chromium plated with crutch or handles screwed down, screwed for iron pipes completeall as specified and directed. |
| 46 | Supply and fix in repair 15mm bore fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed. |
| 47 | Supply and fix in repair 15mm bore angle cock fancy type cast copper alloy chromium plated with crutch or handles screwed down, screwed for iron pipes as fixed complete all as specified and directed. |
| 48 | Supply and fix in repairPVC connection pipe 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed. |
| 49 | Supply and fix in repair brass chromium plated shower rose 125mm size with or without swivel joint complete all as specified and directed. |
| 50 | Supply and fix in repair 15mm bore fancy type pillar tap cast copper alloy, chromium plated, swan neck type screwed down high pressure with long screwed shanks, screwed for iron pipe complete all as specified and directed. |
| 51 | Supply and fix in repair 125mm PTMT grating doom(minimum weight 40gms) complete all as specified and directed. |
| 52 | Supply and fix in repair vitreous china wash down water closet pan (pedestal Pattern) white (excluding fixing bolts flusing cistern and flush pipe) including connection to drain (or out going pipe) and to flush pipe anti syphonage pipe including P or S trap fixed on floorcomplete all as specified and directed. |
| 53 | Supply and fix in repair plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 54 | Supply and fix in repair 10 litre capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe complete all as specified and directed. |
| 55 | Supply and fix in repair vitreous china wash basin oval type counter top of size 550 x 400mmflange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 56 | Supply and fix in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 57 | Supply and fix in repair toilet paper holder, brass, chromium plated, fixed with stainless screw complete all as specified and directed |
| 58 | Supply and fix in repair 40mm bore high density polyethylene pipes (HDPE) with all fittings of pressure rating 6 kgf/sqcm fixed to walls, ceilings or in floors etc. complete all as specified and directed. |
| 59 | Supply and fix in repair looking mirror ofsize 600mm x 450mm x 5mm thick bevelled edge of selected quality glass, decorative type mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers completeall as specified and directed. |
| 60 | Supply and fix factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45X85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 61 | Supply and fix factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws complete all as specified and directed.Note:- Stainless steel butt hinges with S.S screws shall be measured and paid seperately under respective items. |
| 62 | Material and labour for cutting holes into or through brick wall built in cementmortar of superficial area not exc 150 sqcm and making good in CM (1:3) or cement concrete (1:2:4) type B-1 as required complete all as specified and directed. |
| 63 | Material and labour for welding in repairs n. exc 2.5cm in length, thickness of metal to be welded exc 6mm but n. exc 9mm complete all as specified and directed. |
| 64 | Dismantling of 110/100/75mm dia PVC/ cast iron or reinforced concrete drain pipes with all fittings, jointed in cement mortar and taking out of trenches/ from wall, if required complete all as specified and directed. |
| 65 | Supply and fix 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including stack clamp of suitable size complete all as specified and directed. |
| 66 | Supply and fix 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 67 | Supply and fix 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including stack clamp of suitable size complete all as specified and directed. |
| 68 | Supply and fix 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 69 | Supply and fix 110mm bore PVC (SWR) juction single (singleT) equal or unequal with access door complete all as speified and directed |
| 70 | Supply and fix 110 mm bore PVC (SWR) bends with access door any radius complete all as speified and directed. |
| 71 | Supply and fix 75 mm bore PVC (SWR) bends any radius complete all as speified and directed. |
| 72 | Supply and fix 75mm bore PVC (SWR) juction single (singleT) equal or unequal complete all as speified and directed |
| 73 | Supply and fix in repair 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 74 | Supply and fix in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 75 | Supply and fix 32mm bore brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap complete all as specified and directed. |
| 76 | Supply and fix in repair 32mm bore PVC corrugated waste pipe 800mm long complete all as specified and directed. |
| 77 | Supply and fix in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 78 | Supply and fix in repair towel ring of CP fixed with and including chromium plated brass screws and wooden/ plastic cleats complete all as specified and directed. |
| 79 | Supply and fix in repair soap dish, brass, chromium plated complete all as specified and directed. |
| 80 | Supply and fix 6 door personal locker made of 0.50mm CRCA sheet with powder coated having inbuilt cam lock of overall size 0.45 (W) x 0.45 (D) x 1.95 (H) complete all as specified and directed.Make- PLU MAIN 6DR CAM LOCK model of Godrej or equivalent model of Methodex Sys Ltd/ Durian. |
| 81 | Material and labour for brick work with sub class `B` bricks, old size,straight or curved on plan exc 6m mean radius built in cement mortar (1:6)complete all as specified and directed. |
| 82 | Material and labour for 10mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:6) andfinish the surfaceseven and smooth without using extra cement as in wall complete all as specified and directed. |
| 83 | Material and labour for glazed ceramic tiles of size 300x450x7-8 mm (premium quality) coloured in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick cement plaster in cement mortar (1:4) completeall as specified and directed. |
| 84 | Material and labour for ceramic, non skid coloured tiles (premium quality) 7 to 8mmthick (square/rectangular) area of each tile exceeding 0.11sqm but not exc. 0.18sqmas in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar (1:6)complete all as specified and directed. |
| 85 | Supply and fix solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part–II (2020) complete all as specified and directed. |
| 86 | Supply and fix factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed. |
| 87 | Suplly and fix stainless steel 125mm size butt hinges, medium weight complete all as specified and directed. |
| 88 | Supply and fix 150mm long aluminium handles, cast type, anodized complete all as specified and directed. |
| 89 | Supply and fix vitreous china white wash down water closet pan (pedestal pattern) with ‘P’ or ‘S’ trap, front or back inlet, fixing bolts and making all necessary connections including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete as specified and directed. |
| 90 | Supply and fix counter top oval shaped vitreous china wash hand basin, white, of size 560mmx410mm fixed to granite/marble top slab, including cutting for and pinning in and including 32 mm bore cast copper alloy chromium plated waste fittings, 32mm dia PVC waste pipe 800mm long and 15mm bore fancy type long body swan neck pillar tap cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed. |
| 91 | Supply and fix gun-metal globe or gate valves 20 mm dia with iron wheel head screwed both ends for iron pipe complete all as specified and directed. |
| 92 | Supply and fix 15mm bore stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 93 | Supply and fix PVC connection pipe 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed. |
| 94 | Supply and fix brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 95 | Supply and fix health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 96 | Supply and fix 15mm bore angle cock fancy type cast copper alloy chromium plated with crutch or handles screwed down, screwed for iron pipes as fixed complete all as specified and directed. |
| 97 | Supply and fix looking mirror ofsize 600mm x 450mm x 5mm thick bevelled edge of selected quality glass, decorative type mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers completeall as specified and directed. |
| 98 | Supply and fix sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 99 | Supply and fix 110 mm bore PVC (SWR) vent cowl complete all as specified and directed |
| 100 | Supply and fix 32mm bore low density polyethylene pipes (LDPE) with all fittings of pressure rating 6 kgf/sqcm fixed to walls, ceilings or in floors etc. complete all as specified and directed. |
| 101 | Supply and fix 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 102 | Supply and fix 100mm PTMT grating doom(minimum weight 25gms) complete all as specified and directed. |
| 103 | Material and labour for vitrified ceramic tiles (light shade) (premium quality) 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match,laid over and including 15mm thick screed bed in cement mortar (1:6)complete all as specified and directed. |
| 104 | All as per item No 103.00 above but in skirting and dado laid over and including 10mm thick rendering in cement mortar (1:4) and -ditto-. |
| 105 | Supply and fix false ceiling with powder coated exposed GI grid suspension system (E-grid T-2430 or equivalent load carrying capacity- 12.50 Kg/sqm with mid span deflection n. exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long of size- 24x38mm x 0.25mm thick, cross tee of section size- 24x27mm x 0.25mm thick 1200mm/600mm long and wall angle of section size 22x22mm x 0.4mm thick. The wall angle shall be fixed on PVC dash fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The main runners to be placed @ 1200mm, The cross tee 1200mm will be inserted in pre-cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmx600mm. Additional cross tee of 600mm shall be placed perpendicular to the cross tee1200mm long to finally form a grid of 600mm x 600mm shall be supported by 4mm dia G.I. wire from perlins/soffits. 6mm thick high pressure steam cured non Asbestos fibre cement designer ceiling board (density> 1200kg/cum, modules of rupture (M.O.R)-15.85 Mpa, thermal conductivity (k)-0.0872 W/mk) of size 595mm x 595mm, confirming to IS 14862 & type B catagory III of ISO 8336-1993, (Reaction of fire-A2 -s1-d0) tested as per EN 13501 Part-I & BS-476 part-4, 5, 6 & 7, should be placed in the grid module to form a false ceiling complete all as specified and directed.Make: Armstrong/ Saint Gobain/ Lafarge/ Everest. |
| 106 | Material and labour for complete removal of existing treatement and providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 107 | Material and labour for preparation of new plastered/ puttysurfaces of walls and applying two coats of acrylic washable distemper over a coat of alkali resistance primer complete all as specified and directed. |
| 108 | Material and labour for PCC (1:2:4) type B2 (using 40 mm graded stone aggregate ) as in foundation, filling and mass concrete complete all as specified and directed. |
| 109 | Material and labour for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bres-summers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished flat surfaces of concrete complete all as specified and directed. |
| 110 | Material and labour for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or slopping) with rough finished flat surfaces of concrete complete all as specified and directed. |
| 111 | Material and labour for form work to edges of concreteflats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide with rough finished surfaces of concrete complete all as specified and directed. |
| 112 | Material and labour for RCC (1:2:4) (nominal mix) type B-1 (using 20mmgraded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 113 | Material and labour for RCC (1:2:4) (nominal mix) type B-1 (using 20mmgraded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 114 | Material and labour for mild steel TMT bar 10 mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm diaor securing with clips. complete all as specified and directed. |
| 115 | All as per item No 114.00 but 6mm dia and over upto and including 10mm dia in stirrups, spacers and binders and -ditto-. |
| 116 | Materials and labour for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:4) andfinished the surfaceseven and smooth without using extra cement complete all as specified and as directed. |
| 117 | Materials and labour for finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 118 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. .complete all as specified and directed. |
| 119 | Material and labour for light/fan point wiring (concealed type) with single core PVCinsulated unsheathedmultistranded FRLSH copper conductor cable of 1100 volts grade size 1.5 sqmm (nominal area) in and including 20mm dia heavy duty rigid non metalic PVC conduit with accessories including modular flush metal boxeswith inner and outer modular cover plates for housingswitches, sockets and regulatorswith all fittings and fixing materials with one single core PVC insulated unsheathed 1.5 sqmm (nominal area) multistranded FRLSH copper conductor as earth continuity wire and connected to earth dolly complete all as specified and directed.Note: (a) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for Each individual circuit from the distribution board.(b) Quoted rate shall be included for cuttings /chasing the wall and making good disturbed surfaces to fix PVC conduit and flush metal box.(c) Modular cover plate with frame shall be measured and paid seperately under respective items. |
| 120 | All as per item No. 119.00 here-in-before but for one five pins 5 Amps switch socket outlet point on independent board and -ditto-. |
| 121 | All as per item No. 119.00 here-in-before but for one five pins 5 Ampssocket outlet point on same board and -ditto-. |
| 122 | All as per item No. 119.00 here-in-before but for 15 amps socket outlet on independent board with 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade including 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade as earth continuity conductor and connecting to common earth dollyand -ditto-. |
| 123 | Supply and fix modular switch 1 way 6 amps, 1 module complete all as specified and directed |
| 124 | Supply and fix modular switch 1 way 16 amps, 1 module complete all as specified and directed. |
| 125 | Supply and fix modular shuttered sockets 6 amps, 3/5 pin combined two module complete all as specified and directed. |
| 126 | Supply and fix modular shuttered sockets 6/16 amps, 3/5 pin combined two module complete all as specified and directed. |
| 127 | Supply and fix modular fan regulator step type 120W, 2 module complete all as specified and directed. |
| 128 | Supply and fix modular white cover plate with frame of 3 module complete all as specified and directed. |
| 129 | Supply and fix modular white cover plate with frame of 8 module complete all as specified and directed. |
| 130 | Supply and fix modular white cover plate with frame of 6 module complete all as specified and directed. |
| 131 | Supply and fix in repair LED tube light fitting 1 x 20W (+/- 5%), 220V, AC with extruded strip in thermally conductive material & extruded housing in optically efficient material milky white with system lumen efficacy > 120 lumen per watt minimum system 2300 - 2400 and chip, Integrated electronic driver, SMD based LED constant current supply with double sided connection to avoid short circuit and surge protection greater than 2.5 KV, IP 20 protection and CRI>80, Power factor > 0.95, THD less than 15%, correlated Colour temperature (CCT) of 6500K, Operating Voltage of 140 V to 270 V, frequency of 50Hz burning hours 50000 hours with comprises of CRCA pre coated metal housing complete all as specified and directed. |
| 132 | Supply and fix in repair LED lights fittings with extruded aluminium housing, high quality PC diffuser, efficacy- 100lm/W, 10 watt, 220V, AC, 6500K, CRI ≥80, 2 feet long, integrated design including connecting up withflexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 133 | Supply and fix 300mm sweep steel body exhaust fan AC single phase 230/240 volt. 1400 RPM, heavy duty, ISI marked, along with metal blade powder coated metalic finish with GI sheet louvers, low noise including necessary electric connection with and including cutting/making opening having dia of the hole for 300mm sweep exhaust fan inany type of walls of any description with nut, bolt, washer and making good distrubed surfaces complete all as specified and directed. |
| 134 | Supply and fix in repair sheet metal enclosureSPN DB 8 waysdouble door having facility to fix MCB in incomer and MCBs in outgoing,metal door IP-43type complete fitted with bus bars, neutral links, blanking plates complete all as specified and directed. |
| 135 | Supply and fix in repair MCB SPN, 240 Volts, 40amps, \"C\" series, breaking capacity 10 KA complete all as specified and directed. |
| 136 | Supply and fix in repair MCB SP, 240 Volts, of 6 to 32 amps current rating, 10 KA breaking capacity \"C\" series complete all as specified and directed. |
| 137 | Supply and fix in repair ceiling fans complete with blades, down rods,and accessories, 230 V, 1200 mm sweep. minimum air delivery 210 CFM with service value 6.00 BEE. 5 star rated with brushless direct current motor (BLDC) complete all as specified and directed.Note:- Old unserviceable fan shall be deposited to E/M store. |
| 138 | Material and labour forconcealed submain wiring comprising single core , 2 run of 4 sqmm nominal cross sectional area, FR-LSHmultistrandedcopper conductor cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including appropriate dia. in PVC conduit and its fittings complete including provision of 1run of 4 sqmm nominal cross sectional area, FR-LSH multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earthwirecomplete including taking down old unserviceable sub main wiring complete allas specified anddirected.Note :-(a) Cost for extra length of cables / wire required for connection to MCBs/DB\"s shall be included in quoted rates.(b) Cost for cuttings /chasing of wall etc and making good the disturbed surface shall be included in quoted rates. |
| 139 | Material and labour for earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanized iron as steel,protected by 15mm dia GI pipe (medium grade) including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 6 cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion complete as specified and directed.Note:- GI wire upto 7.5m including testing shall be included in qouted rates. |
| 140 | Material and labour for earth continuity conductor or main earthing lead with4mm dia GI wire, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or DB\"s / Indoor type LT PBs orany other indicated situation for loop earthing etc complete all as specified and directed |
| 141 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store for keeping in safe custody for reuse complete all as specified and directed. |
| 142 | Supply and fix in repair 36 W LED recessed ceiling light with glare free uniform illumination, white powder coated CRCA housing, with transulcent frosted diffuser and driver inbuilt 4KV surge protection, efficacy > 100 lm/W, CRI ≥80, 5700K suitable for 600 x 600 mm (2 feet x 2 feet)grid ceiling complete with all accessories including internally prewired connecting upto flexible copper conductor cable of suitable size complete all as specified and directed. |
| 143 | Supply and fix in repair 25 Amp modular type starter 2 module including 16 Amp socket, blanking plate, flush to wall with flush box of 4 module for AC and geyser points complete all as specified and directed.Make- LEGRAND /HAGER /SIEMENS /ABB /L&T / SCHNEIDER / GE |
| 144 | Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed. |
| 145 | Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 m in depth for foundation etc or for cess well cess pits man holes pier holes etc n.exc 10 sqm on plan n.exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed. |
| 146 | Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 147 | Removing excavatedmaterial (soil) notexc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 148 | Supply and fix junction box of size 300 x 200 x 105 mm made out of 1.6mm thick SMC sheet weather proof dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 04 nos aluminium bus bar of size 20 x 5 mm fixed on insulator and one MCB of capacity 10 Amp complete fixed on pole with and including suitable size MS flat iron clamp nut , bolt and washers of suitable size etc. complete all as specified and directed. |
| 149 | Supply and fix 40mm outer dia PVC DWC pipe (double wall corrugated) duct pipe as per IS:16205 (Part-24) including coupler for passing of cable for protection of cable complete all as specified and directed. |
| 150 | Supply, laying, connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty with stranded aluminum conductor)of size 16 Sqmm, 4 core, 1100 Volts, confirming to IS-7098 (Part-I) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs complete all as specified and directed.Note : Earth work, brick protection and sand cushioning and protection pipe shall be measured and paid separately under respective item. |
| 151 | Materials and labour for steel tubular swaged poles, type-410, SP-55 (overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coats of black bituminous paint throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, painting black & yellow alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified anddirected.Note: Excavation and earth work and PCC shall be measured and paid separately under respective items. |
| 152 | Supply and fix PVC insulated multicore FR PVC sheathed 2.5 sqmm 3 core multistrand copper conductor for connection of security light from Junction Boxto security light complete all as specified and directed. |
| 153 | Supply and fix 400W LED Flood Light made of pressure die cast aluminium housing with integrated polycarbonate IP Lens cover, IP66 protection and system efficacy should be greater than 135 Lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device and 10 KV surge protection device in luminare. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till life complete all as specified and directed. |
| 154 | Supply and fix 250W LED Flood Light made of pressure die cast aluminium housing with integrated polycarbonate IP Lens cover, IP66 protection and system efficacy should be greater than 135 Lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device and 10 KV surge protection device in luminare. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till life complete all as specified and directed. |
| 155 | Material and labour for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate ) as in foundation, filling and mass concrete complete all as specified and directed. |
| 156 | Material and labour for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate ) as in foundation, filling and mass concrete complete all as specified and directed. |
| 157 | Material and labour for PCC (1:2:4) type B-1 (using 20 mm grade stone aggregate) for coping of pole foundationincluding form work complete all as specified and directed. |
| 158 | Materials and labour for cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail