| 1 | Repairing of AMF Panel , Complete testing and taking out worn out Copper wire and copper lugs and rewiring with new copper wire and copper lugs of required size and length with sequence numbers including taking out worn out components and fixing only required components etc. Complete in all respect including testing. Making AMF Panel proper functional. Upto 82.5 KVA DG Set complete all as specified and directed (Note:-1.Components shall be measured and paid seperately under respective item if replaced and found defective existing during repairing of panel .2.Supply only parts if replaced shall be credited to the contractor under Sch of credit. |
| 2 | All as per item No 1 above but capacity 100/125/140/160/200 And 250 KVA DG set complete all as specified and directed |
| 3 | Supply only rotary selector switch. 4 Pole suitable for DG set up to capacity 250 KVA complete all as specified and directed . |
| 4 | Supply only rotary selector switch 3 pole complete all as specified and directed |
| 5 | Supply only Auto/Manual Selector Switch complete all as specified and directed |
| 6 | Supply only Volt Meter Led complete all as specified and directed |
| 7 | Supply only Ampere Meter Led complete all as specified and directed . |
| 8 | Supply only spreader upto 100 Amps.(Set of Two) complete all as specified and directed |
| 9 | Supply only spreader upto 200 Amps.(Set of Two) complete all as specified and directed |
| 10 | Supply only spreader upto 300 Amps.(Set of Two) complete all as specified and directed |
| 11 | Supply only Push Button complete all as specified and directed |
| 12 | Supply only Under Voltage Relay.complete all as specified and directed |
| 13 | Supply only single phase preventor. 3 phase.complete all as specified and directed |
| 14 | Supply only indicating light. R.Y.B complete all as specified and directed |
| 15 | Supply only Voltage monitoring relay. 3 phase complete all as specified and directed |
| 16 | Supply only Relay 12v, 24v and 220v. 8 pins with bracket complete all as specified and directed |
| 17 | Supply only Relay 14 pins 12v, 24v and 220v.with bracket complete all as specified and directed |
| 18 | Supply only Timer. 0-60 secs complete all as specified and directed |
| 19 | Supply only on delay timer complete all as specified and directed |
| 20 | Supply only Current Transformer. 100/5A complete all as specified and directed |
| 21 | Supply only Current Transformer. 160/5A complete all as specified and directed |
| 22 | Supply only Current Transformer. 200/5A complete all as specified and directed |
| 23 | Supply only Current Transformer. 300/5A complete all as specified and directed |
| 24 | Supply only Control MCB 10K SP. \"C\" Curve complete all as specified and directed |
| 25 | Supply only Terminal block TPN Upto 125 Amp complete all as specified and directed |
| 26 | Supply only Terminal block TPN Upto 300 Amp complete all as specified and directed |
| 27 | Supply only Battery Charger suitable of AMF Panel. Trickle battery charging system. 12v complete all as specified and directed . |
| 28 | Supply only Battery Charger suitable of AMF Panel. Trickle battery charging system. 24v complete all as specified and directed |
| 29 | S&F in repair AMF controller for 160/200 KVA. With configuration. |
| 30 | S&F in repair Controller DSE6120MK2 AMF with Configuration.complete all as specified and directed. |
| 31 | S&F in repair Controller GADC321 AMF with Configuration.complete all as specified and directed . |
| 32 | S&F in repair Controller KG934 AMF or equivalent with configurationcomplete all as specified and directed |
| 33 | S&F in repair Controller KG545 AMF or equivalent with configuration complete all as specified and directed |
| 34 | S&F in repair Controller Assy Cat no 0300/6014 complete all as specified and directed |
| 35 | S&F in repair Contactor 4 pole with 2no & 2nc Auxillary Contacts. Type MCX 32complete all as specified and directed |
| 36 | S&F in repair Contactor 4 pole with 2no & 2nc Auxillary Contacts. Type MCX 33/34 complete all as specified and directed |
| 37 | S&F in repair Contactor 4 pole with 2no & 2nc Auxillary Contacts. Type MCX 41.complete all as specified and directed |
| 38 | S&F in repair Contactor 4 pole with 2no & 2nc Auxillary Contacts. Type MCX 43. complete all as specified and directed |
| 39 | S&F in repair Contactor 4 pole with 2no & 2nc Auxillary Contacts. 90 to 125 AMP complete all as specified and directed |
| 40 | S&F in repair Contactor 4pole TC. Ref no. LC1FDP1504A complete all as specified and directed |
| 41 | S&F in repair Contactor 4pole TC. Ref no. LC1FDP3304 complete all as specified and directed |
| 42 | S&F in repair Contactor 3 pole with 2no 2nc auxillary contact. Type- MNX225 complete all as specified and directed |
| 43 | S&F in repair Operating Coil for Contactor from 225-350 Amp complete all as specified and directed |
| 44 | S&F in repair Operating Coil for Contactor below 200 Amp complete all as specified and directed |
| 45 | S&F in repairMCCB In existing AMF Panel ( For Mains cutoff) and fitting angel iron base ( for mccb) with welding/nutbolts in panel of 200 KVA DG Set. MCCB 400 AMP , 4 Pole . 50K. And required leads (copper) from MCCB to Contactor. 4 nos. Connection complete in all respect complete all as specified and directed |
| 46 | S&F in repair MCCB in existing AMF Panel ( For Mains cutoff) and fitting angel iron base ( for mccb) with welding/nutbolts in panel of 160 KVA DG Set. MCCB 320 AMP , 4 Pole . 36K. And required leads (copper) from MCCB to Contactor. 4 nos. Connection complete in all respect. |
| 47 | S&F in repair in existing AMF Panel ( For Mains cutoff) and fitting angel iron base ( for mccb) with welding/nutbolts in panel of 62.5-75 KVA DG Set. MCCB 125 AMP , 4 Pole . 36K. And required leads (copper) from MCCB to Contactor. 4 nos. Connection complete in all respect complete all as specified and directed |
| 48 | S&F in repair MCCB 4 Pole . 400 Amp. 50k. Make L&T, C&S or equivalent complete all as specified and directed |
| 49 | S&F in repair MCCB 4 Pole . 320 Amp. 36k. Make L&T, C&S or equivalent complete all as specified and directed |
| 50 | S&F in repair MCCB 4 Pole . 200 Amp. 36k. Make L&T, C&S or equivalent complete all as specified and directed |
| 51 | S&F in repair MCCB 4 Pole . 125 Amp. 36k. Make L&T, C&S or equivalent complete all as specified and directed |
| 52 | S&F in repair Lead Acid Battery. 150 AH 12V complete all as specified and directed.Make- EXIDE, SF SONIC(EXIDE), DYNEX, POWERZONE |
| 53 | S&F in repair Lead Acid Battery. 120 AH 12V complete all as specified and directed.Make- EXIDE, SF SONIC(EXIDE), DYNEX, POWERZONE |