| 1 | E and M Division Items |
| 2 | Dismantling of old unserviceable/damagedACSR or AAC conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separatelycomplete all as specified anddirected. |
| 3 | Dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of PCC and removing unserviceable meterials from site of work complete all as specified anddirected. |
| 4 | Dismantling of cross-arms of MS channel or angle of any sections, UNSV MS clamps, angle, MS flat iron and nuts, bolts and washerscomplete all as specified and directed. |
| 5 | Dismantling of insulators of any size/type complete all as specified and directed. |
| 6 | Taking up and down old steel tubing 100 mm bore and connections, complete all as specified and directed. |
| 7 | Taking up and down old steel tubing 50 mm bore and connections, complete all as specified and directed. |
| 8 | Taking up and down old steel tubing 40 mm bore and connections, complete all as specified and directed. |
| 9 | Taking up and down old steel tubing 25 mm bore and connections, complete all as specified and directed. |
| 10 | Taking up and down old steel tubing 20 mm bore and connections, complete all as specified and directed. |
| 11 | Taking down U/s sluice valvesize 100 mm dia complete all as specified and directed:- |
| 12 | Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, not exc 10 sqm on plan and not exe 1.5 m in depth and getting out soft / loosesoil complete all as specified and directed. |
| 13 | Returning, filling in trencheswith soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified anddirected. |
| 14 | Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed. |
| 15 | Supply and laying burnt bricks of sub-class \"B\" of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed |
| 16 | Supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqdcover after punning down complete all as specified and directed. Note: Thickness of sand cushioning after punning down will be measured and paid separately. |
| 17 | M&L for cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) foundation filling and mass concrete complete all as specified and directed. |
| 18 | M&L for PCC 1:3:6 type C-2, (using 40mm graded stone aggregate) as in coping including necessary use and waste of form work complete all as specified. |
| 19 | M&L for brick works with sub class \"B\" bricks, straight or cover on plan exceeding 6 m mean radius in cement mortar 1:6 complete all as specified and directed. |
| 20 | M&L for plastering 15 mm thick in cement mortar (1:4) on fair faces of brick masonry (Brick pillar) or concrete surface and finishing the surfaces even and smooth without using extra cement |
| 21 | M&L for cutting existing road / PCC drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified |
| 22 | S&F 3 core PVC insulated and sheathed cable with stranded copper conductor of size 1.5 sqmm, 1100 volt grade complete all as specified and directed. |
| 23 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 10 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note: Necessary earth work will be measured and paid separately under respective items |
| 24 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 16 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 25 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 35 sqmm 3-1/2 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 26 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 50 sqmm 3-1/2 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 27 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 70 sqmm 3-1/2 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 28 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 95 sqmm 3-1/2 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 29 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 120 sqmm 3-1/2 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 30 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 240 sqmm 3-1/2 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 31 | Supply and fix HOT moulded (FRP) jucntion box for street light pole with locking arrangementt with IP -65 protection of size 205x210x112 with 60 Amp 4 way heavy duty terminal block with 10 Amps MCB SP with two steel bracket to fix with polecompleteall as specified and directed by Engr - in - charge. |
| 32 | S&FHot moulded FRP Junction box for street light pole with locking arrangement with IP-65 protection of 205X210X112 with 60 Amp 4 way heavy duty terminal block with 10 Amps MCB SP with two steel bracket to fix with pole complete all as specified and as directed |
| 33 | M&L for preparation of old painted surfaces of steel tubular pole, 9 metre long and applying two coats of black synthetic enamel paint (1st grade quality) upto a height of 1 mtr from the ground level and two coats of aluminium paint over the remaining portion of pole including cross arms, bracing, clamps, etc. and numbering of pole with black paint over the base of white circle of 150mm dia completed for inspection complete all as specified and directed |
| 34 | Supply, install ,test & commissioning LT panel Outdoor, Floor mounted/pedestal type,cubical,self supported,CPRI approved make,front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides IP 52 protection with dust and vermin proof etc,fabricated out of 3.15 mm CRCA sheet duly powder coated, mounted /fixed on and including MS angle iron stand of 1 Mtr height (50 Cm above FFL and 50 Cm below FFL), fabricated out of 50 X50 X6 mm thick MS angles duly painted with two coats of Black enamel synhetic paint over one coat of red oxide primer duly grouted in PCC 1:3:6 foundation,control wiring copper stranded PVC insulated FRLS cables & interconnections od suitable size/ capacityof copper Strips for swirch gear connections from main bus bar,earth bus strip of 25 x 3 mm size for entire length of panel, Suitable size of MS gland with gland plate and aluminium lugs/thumbles for all incoming and outgoing cables etc. complete all as specified and directed by the enginner -in - charge including and accommodating the followings:(a) MCCB TPN 350 Amps 25ka- 1 No (01 No Incomer)(b) MCCB TPN 250Amps 25ka -1 No (outgoing)(c) MCCB TPN 100Amps 25ka -2 No (outgoing)(d) MCCB TPN 63Amps 25ka -2 No ( No outgoing )(e) LED type three Phase indicator with controlling fuses for RYB -01 set (f) 3 phase multifunction energy meter (voltage 0-500V amper 1-125 A and energy consumption in KWH or units consumption including CT\"s and PT\"s )(g) Electrolyte copper busbars PVC colour sleeved 400 Amps capacity TP and 250 Amps for neutral mounted on hygroscopic insulator duly colour coded RYB & Green sleeves |
| 35 | Supply, install ,test & commissioning LT panel Outdoor, Floor mounted/pedestal type,cubical,self supported,CPRI approved make,front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides IP 52 protection with dust and vermin proof etc,fabricated out of 3.15 mm CRCA sheet duly powder coated, mounted /fixed on and including MS angle iron stand of 1 Mtr height (50 Cm above FFL and 50 Cm below FFL), fabricated out of 50 X50 X6 mm thick MS angles duly painted with two coats of Black enamel synhetic paint over one coat of red oxide primer duly grouted in PCC 1:3:6 foundation,control wiring copper stranded PVC insulated FRLS cables & interconnections od suitable size/ capacityof copper Strips for swirch gear connections from main bus bar,earth bus strip of 25 x 3 mm size for entire length of panel, Suitable size of MS gland with gland plate and aluminium lugs/thumbles for all incoming and outgoing cables etc. complete all as specified and directed by the enginner -in - charge including and accommodating the followings:(a) MCCB TPN 250 Amps 36ka- 1 No (01 No Incomer)(b) MCCB TPN 100 Amps 25ka- 2 No (01 No Incomer)(c) MCCB TPN 63 Amps 16ka -2 No (outgoing)(d) LED type three Phase indicator with controlling fuses for RYB -01 set (e) 3 phase multifunction energy meter (voltage 0-500V amper 1-125 A and energy consumption in KWH or units consumption including CT\"s and PT\"s ) (f) Electrolyte Aluminium busbars PVC colour sleevedTPN 400 Ampsmounted on hygroscopic insulator duly colour coded RYB & black sleeves |
| 36 | Supply, fabricated, install, test, and commissioning LT outdoor panel weather proof, dust/vermin proof, made out of 3.15mm thick CRCA sheet double openable doorwith angle iron frame and locking arrangement , including bus bar suitable for 3 phase 4 wire system, 415v, 50Hz, AC supply wth bus bar aluminium 250 Amps capacity including with PVC sleeves / taps RYB colours for phases indication, confirming to IP-54, and fixed on raised PCC platform with PCC 1:2:4, type B1 (20 mm graded aggregate) raised base with control wiring and compressing cable gland brass, copper/brass lugs etc confirming to CPRI approved manufacture , complete all as specified and directed by the Engineer-in-charge including and accommodating the followings:Note; All MCCBs are of thermal megnetic release with adjustable type overload protection, shortcircuit protection.(a) MCCB 4 pole 160 Amps 50Hz, 415 V,36 KA-01 no (for incoming)(b) TPN Bus bar Aluminium 300 Amp-01 (outgoing), mounted on hygroscopic insulator duly colour coded RYB & Green sleeves (c) LED type three Phase indicator with controlling fuses for RYB -01 set (d) 3Phase Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96 x96 mm,Current Transformer of suitable rating - Set of three (e) LED type three Phase indicator with controlling fuses for RYB -01 set |
| 37 | Supply, fabricated, install, test, and commissioning LT outdoor panel weather proof, dust/vermin proof, made out of 3.15mm thick CRCA sheet double openable doorwith angle iron frame and locking arrangement , including bus bar suitable for 3 phase 4 wire system, 415v, 50Hz, AC supply wth bus bar aluminium 400 Amps capacity including with PVC sleeves / taps RYB colours for phases indication, confirming to IP-54, and fixed on raised PCC platform with PCC 1:2:4, type B1 (20 mm graded aggregate) raised base with control wiring and compressing cable gland brass, copper/brass lugs etc confirming to CPRI approved manufacture , complete all as specified and directed by the Engineer-in-charge including and accommodating the followings:Note; All MCCBs are of thermal megnetic release with adjustable type overload protection, shortcircuit protection.(a) MCCB 4 pole 160 Amps 50Hz, 415 V,36 KA-01 no (for incoming)(b) TPN Bus bar Aluminium 300 Amp-01 (outgoing), mounted on hygroscopic insulator duly colour coded RYB & Green sleeves (c) LED type three Phase indicator with controlling fuses for RYB -01 set (d) 3Phase Digital panel meter for Amp,Volt,KWH, power factor and other parameter flush mounting of size 96 x96 mm,Current Transformer of suitable rating - Set of three (e) LED type three Phase indicator with controlling fuses for RYB -01 set |
| 38 | S&Fjunction box made from SMC/FRP sheet of size 400x300x190mm having 100A capacity aluminum busbar with 4 way connector including 01No. MCB TPN 63 Amp 10kA 240V capacity fixed to pole /wall with MS clamp made out of FI 25x5mm with nuts, bolts, etc. as required complete all as specified and as directed |
| 39 | M&L for Steel Tubular Swaged Poles Type 410-SP-31(09 Metre long) including cast iron base plate, finial taper plug, cap, mild steel bolts, screws, etc. including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of aluminium primer (externally from top of RCC copping) including painting of black & white alternate strip of 30cm each externally from ground level upto 1.2m and writing MES Pole No. with synthetic enamel paint (first grade quality) complete all as specified directed by Engr-in-Charge. Note: Rate is inclusive of cost of excavtion, earth work & PCC for foundation. Excavation Size:- 0.9x0.9x1.8 mtr, foundation filling (0.6*0.6*1.8) by cement concrete type C2 1:3:6 (40mm gradedcrushed stone aggregates), PCC 1:3:6, type C-1, using 20mm graded stone aggregate add in coping (0.3x0.3x0.3) of poles, Removing excavated materials to a distance not exceeding 50 metre and depositing where directed. |
| 40 | Supply and fixingLED street light fitting 70Watt (incl 10 KV SPD) 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection having efficiency > 110 LPW complete all as specified and directed by Engineer-in-Charge . |
| 41 | Taking out old existing earthing and M&L for new Earthing complete formachinery equipment installed at power house/sub station with copperearth plate electrode 600mm x 600mm x 3.15mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to copper strip 20mm X 3mm main earthing leadby means of bolts, nuts, check nuts and washers of galvanised iron and protected with 40mm dia light grade GI pipe all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board andtesting on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm gradedcrushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4)type B-1 (using 20mm graded crushed stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 40mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. |
| 42 | Supply and Laying 100 mm bore Ductile iron Pressure pipe, Class K9, Centrifugally cast with socket spigot ends conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside Zinc coating with finishing layer of bitumen/Epoxy coating suitable for push-on-joint (rubber gasket D joining), in any length and all jointing material as per site requirement for branch connection etc complete all as specified and directed. |
| 43 | Supply and laid Pipes galvanized \"medium gradefor cable protection complete of 40mm dia completeincluding taking down old unserviceable pipe all as specified and directed by Engineer-in-Charge. |
| 44 | Supply and laid Pipes galvanized \"medium gradefor cable protection complete of 50mm dia completeincluding taking down old unserviceable pipe all as specified and directed by Engineer-in-Charge. |
| 45 | M&L Steel Tubes, \"Medium grade\", 50 mm bore galvanised, with all fittings(i.e bends , elbows , tees , short pieces , connectors , backnuts , diminishing pieces , caps , plugs , unions , flange etc) incl weldinglaid in trenches/wall/floorcomplete all as specified and directed. |
| 46 | M&L Steel Tubes, \"Medium grade\", 40 mm bore galvanised, with all fittings(i.e bends , elbows , tees , short pieces , connectors , backnuts , diminishing pieces , caps , plugs , unions , flange etc) incl weldinglaid in trenches/wall/floorcomplete all as specified and directed. |
| 47 | M&L Steel Tubes, \"Medium grade\", 25 mm bore galvanised, with all fittings(i.e bends , elbows , tees , short pieces , connectors , backnuts , diminishing pieces , caps , plugs , unions , flange etc) incl weldinglaid in trenches/wall/floorcomplete all as specified and directed. |
| 48 | M&L Steel Tubes, \"Medium grade\", 20 mm bore galvanised, with all fittings(i.e bends , elbows , tees , short pieces , connectors , backnuts , diminishing pieces , caps , plugs , unions , flange etc) incl weldinglaid in trenches/wall/floorcomplete all as specified and directed. |
| 49 | M&L for DI specials (Tee, Bend, Tail Piece etc) of size upto 150mm bore for fixing in existing or new pipe line complete all as specified and directed. |
| 50 | M& L for cutting out existing CI/GI pipe line of size 100 mm dia all as spoecified as directed. |
| 51 | S&F sluice valve cast iron size 100 mm dia, confirming to IS-14846 both end flanged with S/S spindle with nut class PN - 1.6 ISI marked complete with hand wheel nuts, bolts, washers & rubber gasket etc for the following size:- |
| 52 | S & F in replacement of u/s Gun metal globe or gate valves with iron wheel, head, screwed both ends for iron pipe and fixed for 50 mm bore pipe including dismantling of unserviceable valve complete all as specified and directed. |
| 53 | S & F in replacement of u/s Gun metal globe or gate valves with iron wheel, head, screwed both ends for iron pipe and fixed for 40 mm bore pipe including dismantling of unserviceable valve complete all as specified and directed. |
| 54 | S & F in replacement of u/s Gun metal globe or gate valves with iron wheel, head, screwed both ends for iron pipe and fixed for 25 mm bore pipe including dismantling of unserviceable valve complete all as specified and directed. |
| 55 | S & F in replacement of u/s Gun metal globe or gate valves with iron wheel, head, screwed both ends for iron pipe and fixed for 20 mm bore pipe including dismantling of unserviceable valve complete all as specified and directed. |
| 56 | M&Lfor drilling and tapping water mains of any dia (in position) for branch connections of the internal dia upto 20/25 mm dia complete all as specified and directed. |
| 57 | Supply and fix MS clamp , made out of any MS section as required at site incl nuts -bolts & washers of suitable size incl necessary welding & two coats of synthetic enamel paint over one coat of red oxide primer using steelconforming to Fe-290 Gde-E-165fixed in repairs complete all as specified. |