| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation of poles, cables etc, not exc10 sqm on plan and getting out in soft/ loose soilincluding taking out brick protection etc. complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, levelling, watering andwell ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 3 | Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed. |
| 4 | M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: Punned down thickness shall only be measuered and paid. |
| 5 | M&L for laying brick sub class \"B\" using old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed |
| 6 | Supply and fixing/laying galvanised iron tubing 40 mm bore, light grade with all fittings for passing of under ground cable including taking down old pipe complete all as specified and as directed. |
| 7 | Supply and fixing/laying galvanised iron tubing 50 mm bore, light grade with all fittings for passing of under ground cable including taking down old pipe complete all as specified and as directed. |
| 8 | M&L for dismantling the servo controlled voltage stabilizer in position upto capacity 400 KVA including taking down all incoming/ outgoing connection and lifting of core from the stabiliser for identification of fault and reassembling after rectification of fault. Note:- Spares parts if required for replacement shall be paid under the respective item as under. |
| 9 | M & L for servicing of servo controlled voltage stablizer upto capacity of 400KVA,including refreshing the all connection, greasing, and conducting following tests:- (i) Testing of oil (ii) testing of insulation resistance (ii) testing of leakage current and output voltage all as specified and directed by Engr in charege. Note : If oil found unsv the oil shall be replaced with fresh transformer oil and transformer oil shall be paid under the respective item as under. |
| 10 | S & F in replacementof defective electronic circuit card (PCB) and making electrical connection for servo voltage stablizer of existing make and cap upto 400 KVA complete all as specified and as directed. |
| 11 | S & F in replacementof defective microproccessor based control card for each phase and making electrical connection for servo voltage stablizer of existing make and cap upto 400 KVA complete all as specified and as directed. |
| 12 | S & F in replacementof defective trigger transformer and making electrical connection for servo voltage stablizer of existing make and cap upto 400 KVA complete all as specified and as directed. |
| 13 | S & F in replacementof defective servo motor 3 Kg torque and making electrical connection complete all as specified and as directed. |
| 14 | S & F in replacementof defective servo motor 10 Kg torque and making electrical connection complete all as specified and as directed. |
| 15 | S & F in replacementof RC network for servo motor 3 Kg torque and making electrical connection complete all as specified and as directed. |
| 16 | S & F in replacementof RC network for servo motor 10 Kg torque and making electrical connection complete all as specified and as directed. |
| 17 | S & F in replacementof unserviceable carbon brush suitable for servo voltage stablizer of existing make and cap upto 400 KVAand making all electrical connections complete all as specified and as directed. |
| 18 | S & F in replacementof Dimmerstatfor servo voltage stablizer 100-125 Amp suitable for servo voltage stabilizer of cap 50 to 100 KVAand making electrical connection complete all as specified and as directed. |
| 19 | S & F in replacementof dimmerstat 150 to 200 ampsuitable for servo voltage stabilizer of cap100-150 KVA and making electrical connection complete all as specified and as directed. |
| 20 | S & F in replacementof dimmerstat 300 to 500 amp suitable for servo voltage stabilizer of cap 200-400 KVA and making electrical connection complete all as specified and as directed. |
| 21 | S & F in replacement ofservo voltage stablizer instrument transformer of existing make and cap upto 400 KVA and making electrical connection complete all as specified and as directed. |
| 22 | Supply onlytransformer oil strength not less than 40 KV at 4mm gap complete all as specified and as directed. |
| 23 | Supply, laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 35 Sqmm 3.5 core including taking out old unsv cable from trenches complete all as specified and as directed. |
| 24 | Supply, laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 50 Sqmm 3.5 core including taking out old unsv cable from trenches complete all as specified and as directed. |
| 25 | Supply, laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 70 Sqmm 3.5 core including taking out old unsv cable from trenches complete all as specified and as directed. |
| 26 | M&L forearthing with steelearth plate electrode ofsize 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, including necessary earthwork, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I including taking down old unserviceable material and testing on completion etc complete all as specified and as directed. |
| 27 | S&F in repairs MCCB, 4 pole, 250 Amps, 415 V, 36 KA breaking capacity, thermal magnetic release type ICS=100% ICU complete all as specified and as directed. |
| 28 | S&F in repairs MCCB, 4 pole, 200 Amps, 415 V, 36 KA breaking capacity, thermal magnetic release type ICS=100% ICU complete all as specified and as directed. |
| 29 | S&F in repairs MCCB, 4 pole, 160 Amps, 415 V, 36 KA breaking capacity, thermal magnetic release type ICS=100% ICU complete all as specified and as directed. |
| 30 | S&F in repairs MCCB, 4 pole, 125 Amps, 415 V, 36 KA breaking capacity, thermal magnetic release type ICS=100% ICU complete all as specified and as directed. |
| 31 | Supply and fixing TPN/FP 40 to 100 AMP, 415V ,10KA \"B\" curve miniature circuit breaker (MCB)in the DB complete with connection testing and commissioning complete all as specified and as directed. |
| 32 | Supply and fixing TP 63 AMP, 415V ,10KA \"B\" curve miniature circuit breaker (MCB)in the DB complete with connection testing and commissioning complete all as specified and as directed. |
| 33 | Supply and fixing SPN 40 to 63 AMP, 240V, 10KA \"C\" curve miniature circuit breaker (MCB)in the MCB DB complete with connection testing and commissioningcomplete all as specified and as directed by Engr-in-Charge. |
| 34 | M&L for preparation of old painted surfaces of voltage stabiliserafter scraping existing painted surfaces and priming with one coat of red oxide primer over and includingtwo coats of synthetic enamel colored paint as approved by engr -in - charge and GE complete all as specified and as directed by Engr-in-Charge. |
| 35 | Repairof 4 KW Thyristor type Constant Current Regulator (CCR) (Make: NASU ) by providing OEM service engineer including repairing/replacing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and complete checkingThyristor type CCR capacity 4KW complete all as directed and as directed by Eng-in-charge.Note: (i) All the components required for repairing to make the CCR serviceable shall be provided by the contractor and measured separately..(ii) The CCR shall be repaired and serviced by OEMs Rep/ his auth rep only. |
| 36 | Calibration of 4 KW Thyristor type Constant Current Regulator (CCR) (Make: NASU ) by providing OEM service engineer including servicing complete all as directed and as directed by Eng-in-charge.Note: (i) Calibration and servicing of CCR will be carried outquarterly.(ii) Each CCR test will becarried out and calibration report will be submitted to Eng-in-charge. (iii) The CCR shall be calibrated and serviced by OEMs Rep/ his auth rep only. (iv)Servicing includes dusting, cleaning, checking of all conection and making the connection healty. |
| 37 | Supply ofMain contact card including RMS to DC converter card and taking out unsv card complete all as directed and as directed. |
| 38 | Supply of Over current tripand taking out unsv card complete all as directed and as directed. |
| 39 | Supply ofRelay card-02 Nos andtaking out unsv card complete all as directed and as directed. |
| 40 | Supply ofTTM card andtaking out unsv card complete all as directed and as directed. |
| 41 | Supply of24 Volt DC plug in type relay andtaking out unsv relay complete all as directed and as directed. |
| 42 | Supply of48 volt DC plug in type relay suitable for 11 pin socket andtaking out unsv relay complete all as directed and as directed. |
| 43 | Supply of 240 volt AC plug in type relay andtaking out unsv relay complete all as directed and as directed. |
| 44 | Supply of thyristor 65 RK 160 andtaking out unsv part complete all as directed and as directed. |
| 45 | Supply ofHRC fuse link 32 Amps Set of 02 Nos andtaking out unsv fuse complete all as directed and as directed. |
| 46 | Supply ofHRC fuse link 4 Amp andtaking out unsv fuse complete all as directed and as directed. |
| 47 | Supply of 02 pole 8 way brilliancy switch Rotary , MB type andtaking out unsv switch complete all as directed and as directed. |
| 48 | Supply of Power transistors MJ 11016 (Set of 02 Nos) andtaking out unsv one complete all as directed and as directed. |
| 49 | Supply of 30 Amp contactor (Model: 3TF33) suitable for 4Kwh Constant Current Regulator (CCR)andtaking out unsv one complete all as directed and as directed. |
| 50 | Supply of high speed semi conductor protection fuse GSB 50 suitable for 4 KW CCR complete all as directed and as directed. |
| 51 | Supply and fix digital true RMS meter 10 amp for CCR complete all as directed and as directed. |
| 52 | Supply and fix digital true meter 100 micro amp DC coil moving meter (96x 96) complete all as directed and as directed. |
| 53 | Supply and fix lightning arrestor 4.5 KV grade suitable for 4 KW CCR complete all as directed and as directed. |
| 54 | Supplyand fix LED lamp Green, yellow and red as per existingsuitable for 4 KW CCR complete all as directed and as directed. |
| 55 | Taking out the connection from mains and carrying out bypass arrangement and disconnecting the connection of Online UPS upto 30 KVA and transporting to workshop and return back after repair with replacement of following itemsall as required and directed at site .Note :Cost of spare Iteparts will be measured and paid separately. |
| 56 | Supply only the cared IGBTcard with fixing etc complete all as directed and as directed. |
| 57 | Supply onlythe driver cardcomplete all as directed and as directed. |
| 58 | Supply onlycontrol card complete all as directed and as directed. |
| 59 | Supply onlythe Transformer copper wound suitable as per sample complete all as directed and as directed. |
| 60 | S&F in Repair/ Replacement ofmaintenance free starting battery 12 volts,42 AH etc all as specified and directed by engineer in charge. MAKE : EXIDE/ AMARON or equivalent as approved by GE. |
| 61 | Opening,dismantling and disconnecting all water Connection and electrical connection of Washer Extractor/ hydro extractor capacity Upto 15 Kg, of make Superfab and Reassembling the same after repair including oiling, greasing and alignment of inner basket, alignment of shaft, pulley alignment, contact set of contactor cleaning, servicing and cleaning of pneumatic kits, air filter cleaning, cleaning the drain system and turning work and reassemble the same for the smooth functioning of the machine.Note: The Washer extractor/ hydro extractor shall be repaired and serviced by OEMs Rep/ his auth rep only. |
| 62 | S & F PVC drain pipe of dia 32mm LDPE pipe for existing capacity and make complete all as specified and directed. |
| 63 | Opening, dismantling and disconnecting all water connection and electrical connection of Dryingtumbler capacity of 15 kg of make Superfab and reassembling the same after repairincluding Oiling, cleaning, servicing and greasing, balancing and alignment of cylindrical basket, balancing of blower, shaft turning, cleaning and servicing of steam radiator for the smooth functioning of the machine complete all as specified and directed.Note: The Drying tumbler shall be repaired and serviced by OEMs Rep/ his auth rep only. |
| 64 | S & F in replacement ofstrip heater of existing make complete all as specified and directed. |
| 65 | Opening dismantling and disconnecting all water connection and electrical connection of flat work Ironer with double roll make superfab and Reassemble the same for repair after removing nuts and bolts including Oiling, cleaning, servicing and greasing, balancing and alignment improvement of chest and rollers, servicing and cleaning of Pneumatic kits, servicing of electrical panel and variable frequency drive for the varying of speed of motor complete all as specified and directed. |
| 66 | Disconnecting all electrical connection of the air compressor and taking out cylinder from the compressor and repair the same with replacement of Engine oil, key of shaft and re-fixing the same including testing complete all as specified anddirected.Note:-Engine oil, key of shaft are deemed to be included in quoted rates. |
| 67 | S&F in replacement ofWater solenoid motorized Pneumatic valve of existing size and make for inlet and outlet complete all as specified and directed. |
| 68 | S&F in replacement ofscreen of panelof washer extractor machine as per existing complete all as specified and directed. |
| 69 | Disconnecting the electric induction motor from the existing machine of any size and taking out the unserviceable winding wire complete and cleaning the slots, rewinding the motor with super enameled copper windings wire of existing gauge including all other insulating material of the capacity03 HP of any make andre-fixing the same after repair of existing machine Including testing complete all as specified and as directed.Note:- Copper winding and other insulating materials to be replaced are inclusive of quoted rates. |
| 70 | S&F in replacement of iron steam resting pad of existing make and existing size complete all as specified and as directed. |
| 71 | S&F in replacement of Drying tumbler complete all as specified and as directed. |
| 72 | Supply and fixing of 4.00Sqmm 4 core multi stranded copper conductor cable (FRLSH) 1100 Volt grade drawn through20/25 mm diaPVC Casing Capingafter and inclduingtaking down existing submain wiring complete all as specifiedand as directed. |