| 1 | Note: (i) Please refer Schedule \"A\" Notes given on serial page No. 21 to 28 of tender documents. |
| 2 | BUILDING WORKS |
| 3 | Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule \"A\" Part-I brought forward from serial page No. 29. |
| 4 | LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS |
| 5 | Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTHWORK as listed in Schedule \"A\" Part-II brought forward from serial page No. 30 & 31. |
| 6 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule \"A\" Part-III brought forward from serial page No. 32 & 33. |
| 7 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule \"A\" Part-IV brought forward from serial page No. 34. |
| 8 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule \"A\" Part-V brought forward from serial page No. 35 & 36. |
| 9 | Lump sum price worked out by the contractor for PQC FOR ARMING DE-ARMING BAY, HANG UP POINT & CONNECTIONTAXI TRACK TO BLAST PENS WORKSas listed in Schedule \"A\" Part-VI brought forward from serial page No. 37 to 39. |
| 10 | Lump sum price worked out by the contractor for PCC ROAD WORK as listed in Schedule \"A\" Part-VII brought forward from serial page No. 40. |
| 11 | Lump sum price worked out by the contractor for PCC DRAIN WORKS as listed in Schedule \"A\" Part-VIII brought forward from serial page No. 41. |
| 12 | Lump sum price worked out by the contractor for RCC DRAIN WORKS as listed in Schedule \"A\" Part-IX brought forward from serial page No. 42. |
| 13 | Lump sum price worked out by the contractor for SECURITY WALL WORKS as listed in Schedule \"A\" Part-X brought forward from serial page No. 43 & 44. |
| 14 | Lump sum price worked out by the contractor for VIFT WALL IN FRONT OF BLAST PEN,ARMING & DE-ARMING BAY AND HAND UP POINT WORKS as listed in Schedule \"A\" Part-XI brought forward from serial page No. 45 & 46. |
| 15 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule \"A\" Part-XII brought forward from serial page No. 47 & 48. |
| 16 | Lump sum price worked out by the contractor for FIRE FIGHTING AND FIRE ALARM SYSTEM WORKS as listed in Schedule \"A\" Part-XIII brought forward from serial page No. 49 to 53. |
| 17 | Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKS as listed in Schedule \"A\" Part-XVII brought forward from serial page No. 54. |
| 18 | MISCELLANEOUS ITEMS OF WORKS- SCHEDULE \"A\" PART-XXII (INTERNAL ELECTRIFICATION WORKS) |
| 19 | Supply and fix flame proof weather proof control panel in cast aluminium alloy LM6 construction Cat No. MCDB/ 186 certified by CMRS Dhanbad for Group IIA & IIB. 01 No of 63A TPN MCCB as a incomer and 12 Nos of 16A SP MCB as outgoing with common neutral link, earth bar including fixing to wall complete all as specified and directed. |
| 20 | Supply and fix flame proof weather proof control panel in cast aluminium alloy LM6 construction Cat No. MCDB/ 186 certified by CMRS Dhanbad for Group IIA & IIB. 01 No of 32A DP MCB as a incomer and 04 Nos of 16A SP MCB as outgoing with common neutral link, earth bar including fixing to wall complete all as specified and directed. |
| 21 | Supply and fix flame proof weather proof control panel in cast aluminium alloy LM6 construction Cat No. MCDB/ 186 certified by CMRS Dhanbad for Group IIA & IIB. 01 No of 32A DP MCB as a incomer and 08 Nos of 16A SP MCB as outgoing with common neutral link, earth bar including fixing to wall complete all as specified and directed. |
| 22 | Supply and fixing flame proof heavy duty, turbo force exhaust fan 380mm(15\") sweep, CFM 1120 and including three core 1.5 sqmm, PVC insulated but unsheathed FRLSH cable with multi-stranded copper conductors from ceiling rose to fan complete all as specified and directed. |
| 23 | SEWAGE DISPOSAL WORKS |
| 24 | Supply & fix conventional LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, Vent shaft, connection etc. complete for 10 users capacity complete all as specified and directed.. |
| 25 | SECURITY WALL WORKS |
| 26 | Supply and fixing punched tape concertina coil 600mm dia made with high tensile strength galvanized mild steel wire 2.50 mm dia as per IS 4454 strip material (galvanized MS strip as per IS-1730)with angle iron \"Y\" shaped placed 3.00 metre apart and with 9 horizontal R.B.T stud tied with G.I staples and GI clips to retain horizontal including necessary bolts on GI barbed wire tied to angle iron with reinforced barbed tape (RBT)/ spring core 2.6mm dia wire minimum barb 9 mm width, loop spacing 250± 20mm, coil length 8 metre and fixed in position complete all as specified and directed.Note :-(i) Themake of concertina coil & barbed wire shall be approved by GE conforming to the specifications beforeprocurement.(ii) Mild steel angle (Y-Shape) shall be measured and paid separately. |
| 27 | M&L for preparation of steel surface of any description n. exc. 10cm in width or girth when unconnected with other painting and applying one coat of rust removing paint complete all as specified and directed. |
| 28 | EXTERNAL ELECTRIFICATION WORKS |
| 29 | Supply Install, testing and commissioning of LT Distribution Panel (CPRI type tested) cubicle type IP-65, outdoor type confirming to IS-61439, factory fabricated prewired made out of 3.15mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulted with colour coated heat shrinkable sleeve and shall be mounted on DMC support. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves. The cubicle shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform of LT panel shall be pedestal type of suitable width and 600 mm height above ground level and minimum 400mm below the ground level constructed with bricks (sub class \"B\") work duly plastered in CM (1:3) and PCC copping (1:2:4) not less than 50mm thick over brick pedestal with adequate opening for entry of cable complete as per manufacture recommendation and directed by the Engr-in-charge. A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seventank phosphate treatment front & back opening type and fixing 2 Nos danger notice plan with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following:- |
| 30 | Incomer of LT Panel:(i)MCCB 4 pole 415 Volt, 150 Amps, 25 KA, with Thermal Magnetic Protection unit- 01 No.(ii) Bus bars: 250A TPN + E bus bars running throughout the length of panel.(iii) Multifunction digital meter to measure voltage, current, KWH, PF, Amp with CT\"s set with suitable size.-01 No.(iv) Indicating Lamp LED type 240 Volts AC set of three colour (RYB)- 01 set.(v) Indicating Lamps - 01 Set of threeOutgoing feeders:(i) MCCB 25 Amp TPN 25 KAwith fixed magnetic & thermal adjustable- 01 Nos.(ii) MCB 53 Amp 4P- 01 Nos(iii) MCB 32 Amp TPN - 01 Nos(iv) MCB 40 Amp SPN - 01 Nos(v) MCB 16 Amp SPN - 01 Nos.(vi) Industrial panel mounted plug socket as per IEC 61439 of capacity 63 Amp, 3P+N+Earth- 01 No.(vii) Industrial panel mounted plug socket as per IEC 61439 of capacity 32 Amp, 3P+N+Earth- 01 No.(viii) Industrial panel mounted plug socket as per IEC 61439 of capacity 32 Amp, 2P+Earth- 01 No.(ix) Industrial panel mounted plug socket as per IEC 61439 of capacity 16 Amp, 2P+Earth- 01 No. |
| 31 | (x) Each compartmentalized in construction to accommodate the incoming/ outgoing MCCB and TPN bus bars and outgoing feeders with CO2/ inert gas/ clean agent local flooding system with cylinder located outside the panel.Notes: (i) LT panel board should be Type Tested from CPRI (A copy of valid CPRI type test report to be enclosed while obtaining approval from GE).(ii)SLD diagram for LT panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door.(iii)Rate for the same deemed to include in the quoted rates. (ESP PANEL FOR BLAST PEN) |
| 32 | Supply & installation hot dip galvanised octagonal poles 7 mtr long; top dia 70mm and bottom dia 130mm having sheet thickness 3mm, base plate 200mm x 200mm x 12mm (L x B x T) including foundation bolt size 4 x 20mm dia, 200mm pitch circle dia, 600mm bolt length, 100mm projected bolt length having door opening of sizes 90mm x 500mm above GL and having hot dip galvanized single arm plane arm bracket 1000mm long for pole having top 70mm dia, for mounting street light fitting fixed on the top with nut bolts washers including provision of cable connector for three phase supply and one no MCB SP of 0.5A to 6A alongwith necessary earth work, PCC with iron work all as specified by the manufacture and as approved by GE and directed by Engineer-in-charge complete.Make: Bajaj Model No BOP-7030 or equivalent of Surya/ HPL. |
| 33 | S&F junction box poly carbonate with glass fibre reinforced, environment friendly, recyclable, UV resistant, halogen and silicon free anti acid and anti-corrosive IP65/ 66 in accordance with IE rule internally embedded gasket, junction box including 3 phase 415 volt aluminium bus bar and one no MCB SP 6A, 10 KA to control the street light including necessary clamps, nuts bolts to fix the junction box with poles all specified and directed. |
| 34 | S&F aviation obstacle light die-cast aluminium housing with red polycarbonate dome for better illumination with integral driver, IP-65 protection of capacity 10 watt complete all as specified and directed. |
| 35 | M&L for drilling hole under the road, pavement, hard standing etc. by trenchless technology using ultra sounding technique and necessary machine including supply and laying 150mm dia HDPE pipe suitable for 0.4 Mpa working pressure complete all as specified and directed. |
| 36 | FIRE FIGHTING AND FIRE ALARM SYSTEM WORKS |
| 37 | Supply & fixing automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve complete all as specified and directed. |
| 38 | Supply and fixing dual plates CI wafer type check valve, 80mm bore tested to pressure of 15Kg/ Sqcm complete all as specified and directed. |
| 39 | Supply & fixing of strainer for suction of size 80 mm with complete set all as specified and directed. |
| 40 | Supply and fixing Dual plates CI wafer type check valve, 80 mm bore tested to pressure of 15Kg/ Sqcm complete set all as specified and directed. |
| 41 | Supply & fixing 150 mm foot valve for fire hydrant suction line complete all as specified and directed. |
| 42 | Supply & fixing 80 mm foot valve for fire hydrant suction line complete all as specified and directed. |
| 43 | Supply & fixingof laser Etched LED light double sided exist signage on ceiling/ wall mounted with logo & exit arrow on transparent acrylic sheet of 303mm x 140mm wit powder coated top MS box with 4 hours backup complete all as specified anddirected. |
| 44 | SUMMER APPLIANCESAND COOLING APPLIANCES WORKS |
| 45 | Supply and fixing flameproof pedestal type air ciculator fan, single phase, 415mm (16\") sweep complete all as specified and directed. (04 Nos in each Blast Pen) |