| 1 | Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing all as specified and directed. |
| 2 | M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps. |
| 3 | All as per the desription of srl item No 02 here-in-before but one fan point controlled by one, one way switch 06 Amps. |
| 4 | All as per the desription of srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch. |
| 5 | All as per the desription of srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch. |
| 6 | All as per the desription of srl item No 02 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed. |
| 7 | S&F in repair switch piano flush type, 06 Amps, single pole, one way, 230 volts complete |
| 8 | S&F in repair bell push, flush type, 06 Amps, 230 volts with switch frame complete |
| 9 | S&F in repair switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete |
| 10 | S&F in repair socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete |
| 11 | S&F in repair socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete |
| 12 | S&F in repair ding dong bell, AC, 230 volts, single pole complete |
| 13 | S&F in repair ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, humfree, AC, 230 volts, 100 watts complete |
| 14 | S&F ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm sizecomplete |
| 15 | Supply and fix in repair lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9W LED bulb complete. |
| 16 | Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for Mylinc / Coral / Sleek model accessories etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light point controlled by one, one way switch 06 Amps. |
| 17 | All as per the desription of srl item No 16 here-in-before but one bell point controlled by one bell push switch 06 Amps. |
| 18 | All as per the desription of srl item No 16 here-in-before but one ceiling / Exhaust fan point controlled by one, one way switch 06 Amps. |
| 19 | All as per the desription of srl item No 16 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch. |
| 20 | All as per the desription of srl item No 16 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch. |
| 21 | All as per the desription of srl item No 16 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed. |
| 22 | Supply and fixing in repair modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed. |
| 23 | Supply and fixing in repair modular bell push with indicator, 06 Amps, single pole, one way, 230 volts,complete all as specified & directed. |
| 24 | Supply and fixing in repair modular switch, with indicator, 16 Amps, single pole, one way, 230 volts, one module complete all as specified & directed. |
| 25 | Supply and fixing in repair modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed. |
| 26 | Supply and fixing modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed. |
| 27 | Supply and fixing in repair modular ceiling fan regulator, 02 module, AC, 230 volts, 120 watts, duly ISI marked complete all as specified & directed. |
| 28 | S&F in repair 10/12W LED TL fitting (2 fit) attractive wall mounted type suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete. |
| 29 | S&F in repair on wall / ceiling LED batten lighting fixture 20 watts LED 5700K (4\"), with extruded aluminium heat sink, integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete. |
| 30 | S&F in repair decorative wall mounting light MS/Glass E-27 Base, lamp holder, including 9 Watts LED bulb for fixing in decorative wall mounting light and all accessories pre-wired including connecting upincluding taking down of existing u/s light fitting complete. |
| 31 | S&F in repair Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size completecomplete. |
| 32 | Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts & washers complete. |
| 33 | Removal of existing UNSV fitting, Supply and fixing in repair garden light fitting 9/10 watts, IP65 rated LED Bollard light including of brick/PCC work all as specified and directed. |
| 34 | Supply and fixing in repairs decorative colour of 3 mtr length having pole material GI PU painted pipe and light material as polycarbonate acrylic of length as per Halonix Cat Part No HLDC-45-75-TRI-3M with rated voltage and frequency 240V 150 Hz, system voltage 75W ±10 %, system current < 0.382 mA power factor >0.90 colour out put suffron, white & green (Tiranga colour with same sequence ) and driver efficiency >=80%. Base plate of the pole light shall be of dia 300mm and thickness 12mm PCB hole 260mm dia & 25mm dia light shall be mounted on a half feet PCC plaster, properly fixed with plate and foundation bolts complete all as specified and directed. |
| 35 | Supply and fixing in repair 12 Watt round LED panel recess/surface mountingdownlight in CDL with integraed driver to delivered superior light output and uniformity utilising the latestLED technology, ceiling cutout 145mm mm dia height max 35mmrecess luuminaries all as specified and directed. |
| 36 | Supply and fixing in repair 15 Watt round LED panel recess/surface mountingdownlight in CDL with integraed driver to delivered superior light output and uniformity utilising the latestLED technology, ceiling cutout 145mm mm dia hight max 35mmrecess luuminaries all as specified and directed. |
| 37 | Supply and fix in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed. |
| 38 | Supply and fix in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200mm, cutting of hole in wall, making of wooden frame, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed |
| 39 | S& F in replacementofLED 30 Watt Lamp type, Cast iron pole with base plate of 3 mtr height with die cast aluminiumlighting fixture, polycarbonate diffuser, sillicon rubber gaskat, stainless steel screws, corrosion and UV rays resistant coating and IP 65/66 including of brick/PCC workas reccmend by the manufacturer allasspecified and directed and connecting up with and includingprovision of PVC insulated copper conductor cable 1.5 Sqmm, 2/3 core as required for connections complete all as specified and directed. |
| 40 | Supply and fixing in repair wall mounted fan of 400 mm sweep, 230 volts, AC, 50 Hz capacity, including all arrangements for mounting of fan including connecting up with provision of PVC insulated flexible twisted type copper conductor cable 1.5 Sqmm, 2 core as required for connections complete all as pecified and as directed. |
| 41 | Supply and fix in repair exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed Note:-Old fan should be deposited in the MES yard) |
| 42 | Supply and fix in repair electric water heater, storage type 25 ltrs capacity, BEE star rated, vertical type with suitable size of fastner and incl provision 5 star rated and connecting up of SS braided pipe with adapter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode having adustable knobe for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure having heating element 2 KW and minium two year warranty on product, minimum three years on heating element 5 year warranty on inner tank complete all as specified and as directed Make-Smith/Havells/RacoldNote:- Old/ unsvGeysers to be deposited in MES store |
| 43 | Supply, Installation, Testing and Commissioning in repair of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete . and taking down old/unsv fan and deposit in E/M store yard complete all as specified and directedMake- Orient electric/Atombery/Crompton |
| 44 | Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring. |
| 45 | All as per the desription of srl item No 44 here-in-before but 06 Sqmm nominal cross sectional area and including continuous earth wire of size 06 Sqmm nominal cross sectional area. |
| 46 | All as per the desription of srl item No 44 here-in-before but 10 Sqmm nominal cross sectional area, four single core, with and including continuous earth wire of size 10 Sqmm nominal cross sectional area. |
| 47 | S&F in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 Amps, \"C\" curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete |
| 48 | S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 230 volts, 08 way, with 200 Amps rated copper bus bar and metal double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete |
| 49 | All as per the desription of srl item No 48 here-in-before but 12 way Ditto |
| 50 | S&F in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed. |
| 51 | S&F in repair MCB, SP, AC, 230 volts of 06 to 32 Amps capacity \"C\" curve, 10 KA breaking capacity and making connections by using copper lugs complete |
| 52 | All as per the desription of srl item No 51 here-in-before but SPN 16-40 AMP |
| 53 | S&F in repair MCB, DP, AC, 230 volts of 63 Amps capacity \"C\" curve, 10 KA breaking capacity and making connections by using copper lugs complete |
| 54 | S&F in repair MCCB, 100 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed. |
| 55 | S&F in repair or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete |
| 56 | M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete. (Note: On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.) |
| 57 | Supply and fixing in repair LED flood light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete. pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts & washers complete. Make : Eveready / Philips/ Havells |
| 58 | All as per the desription of srl item No 57 here-in-before but 100 watt |
| 59 | All as per the desription of srl item No 57 here-in-before but 120 watt |
| 60 | S&F in repair industrial type TPN enclosure with a three pin and neutral and earth plug and socket complete with and including 32 Amps MCB, four pole, AC, 415 volts and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete |
| 61 | S&F in repair industrial type TPN enclosure with a three pin and neutral and earth plug and socket complete with and including 63 Amps MCB, four pole, AC, 415 volts and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete |
| 62 | S&F in repair MCCB with fixed type125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete |
| 63 | S&F in repair MCCB, with fixed type 125 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete. |
| 64 | S&F in repair MCCB, with micropreocessor release 160 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete |
| 65 | S&F in repair MCCB, with micropreocessor release 200 Amps, 04 pole, AC, 415 Volts of 36 KA breaking capacity complete |
| 66 | S&F in repair LED strip light/profile lighting with power consumption-12 W/m, Input voltage- 24 V DC, IP 68 waterproof rating, LED density- 280 LEDs /m, 3000k warm white etc as required for connections complete all as specified and directed. |
| 67 | Supply and fixing in repair cuboid 400 mm remote controlled 3 blade ceiling fan with built in LED lights, fixing on grid ceiling suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete all as specified and directed |
| 68 | Supply and fixing in repairs LED 20 Watt post top lantern with die cast aluminium clear/opal acrylic diffuser and IP 65/66 including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 2/3 core as required for connections complete all as specified and directed. Make : Eveready / Philips/ Havells |
| 69 | All as per the desription of srl item No 68 here-in-before but 40 Watt |