| 1 | SCHEDULE A BOQ |
| 2 | Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan & getting out in hard/dense soil complete all as specified and directed. |
| 3 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 4 | Excavating over areas, n exc 1.5 m deep and getting out complete all as specified and directed. |
| 5 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. |
| 6 | M&L forPCC 1:2:4type B1using20 mm graded stoneaggregateas in pillars, post holes and mass concrete complete all as specifiedand directed. |
| 7 | Hardcore of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed. |
| 8 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cmthick, spread, levelled and rammed including watering complete all as specified and directed. |
| 9 | M&L 100mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate complete all as specified and directed. |
| 10 | M&L 50mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate Finished even & smooth without using extra cement complete all as specified and directed. |
| 11 | M&L River sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 12 | Demolition of brickwork or stone/boulder masonry, built in cement mortar complete all as specified and directed. |
| 13 | Dismantling wrought iron or mild steel work of any description not otherwiseprovided for complete all as specified and directed. |
| 14 | Dismantling to Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed |
| 15 | Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and directed. |
| 16 | Removing excavated soil exc. 1.50 Km and n exc 5.0 Km depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 17 | M&L for Pre-cast cement concrete block masonry (1:3:6, type C1 20 mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified. |
| 18 | M&L for rendering 15mm thick in two layers on fair faces ofbrick or concrete surfaces in cement mortar 1:4 finished even & fair complete all as specified and directed. |
| 19 | M&L Plain Cement Concrete 1:2:4, Type B1 (using 20 mm graded granite stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbsincluding demolition of existing one complete all as specified and as directed. |
| 20 | M&L Preparing new surfaces ofplastered or unplasteredwall and applying two coats of cement based paint over one coat of alkali resistant primer complete wash complete ll as specified and directed. |
| 21 | M&L Precast RCC 1:2:4, Type B–1 using 20mm graded stone aggregate as in landings, cover slabs, chullah hoods, Chajjas, water troughs, mangers, Shelves and similar articles with plain faces including formwork, set in cement mortar 1:4 complete all as specified and as directed. |
| 22 | M&L Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 23 | M&L for granite slab 20 mm thick machine cut , bedded and jointed with grey cement slurry and pointed with white cement admixture of pigment to match the sade of granite stone incl grinding and polishing such as steps, platform, counter, cills and other similar work including screed bed or bedding layer of mortar 15mm thick in cm 1:4 complete all as specified and directed. |
| 24 | Rounding for edges of store slab one edge, such as in steps cooking platform and other similar work complete all as specified and directed. |
| 25 | S&F M S angle & flats iron (Posts and struts) in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed |
| 26 | M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 5 to 10mm including taking down existing one complete all as specified and as directed. |
| 27 | Supply only Chain link mesh, made of galvanised wire and shallconfirm to IS 2712-2003 and having zinc coating of type heavy as laid down in IS 4826 including binding wire etc fixed to any type of standards posts complete all as specified and as directed. |
| 28 | Straining and fixing only chain link fencing includingline wires, any mesh size and type of to any type of standards, rails, straining bolts etc including provision 10mm dia MS bars as line wire welded to fencing posts and MS flat iron for fixing fencing wire mesh including taking down existing fencing complete all as specified and as directed. |
| 29 | S & F 10mm dia round bars, cut to length, stitches through chain link fencing between posts and welded to fencing posts and MS flat iron etc complete all as specified and as directed |
| 30 | M & LFramed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening Fe-290(Gde E-165) and fixing complete all as specified and as directed |
| 31 | S&F stainless steel letters 12 inches height made out of 1mm thick stainless steel plate, cut folded, welded to required shape including fixing on the granite with bolt nuts/ steel surface etc, including taking down existing one complete all as specified and directed. |
| 32 | M&L for painting two coats of synthetic enamel paint over one coat of red oxide primer including preparation of steel surfaces surfaces exc. 10 cm width or girth complete all as specified and directed. |
| 33 | Supply and fixing LED Solar street light fitting of output not less than 4000 Lumens including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed by Engineer-in-Charge.Note:- (i) The rates exclude earth work, PCC foundation, coping etc.(ii) The rates include satying the poles in a truely vertical position till the foundations are properly set.(iii) Crane charges for erection shall be deemed to be including in quoted rate.(iv) The rates include the painting of poles with aluminium paint. |
| 34 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m deep for laying of cable, pipes, foundion for poles etc, and getting out in soft / loose soil all as directed. |
| 35 | Removal of surplus soil to a distance exc. 50 m anddeposting where as directed at a level not exceeding 1.5 m above the starting point as directed . |
| 36 | M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling & foundation of pole complete all as directed |
| 37 | Supply and fixing post top lantern/bollardLED type 20 watt 230 watt volts AC outdoor type with decorativepost top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 38 | Supply and fixing track lights /focus lights 20Watts 230 watt volts AC outdoor type withindirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 39 | Supply and fixing ofsheet metal enclosures for DB double boor 4-way 200Amps, 1-ph, 240V, 50Hz complete all as specified and directed. |
| 40 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB,Complete with connection testing and commissioning complete all as specified and directed. |
| 41 | Supply and fixing 240V, 10 KA \"B\" curve Isoator carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 42 | Wiring for circuit/submain wiring alongwith earth wire with the following 2x1.5+1x1.5 sqmm sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed. |
| 43 | M&L for outdoor sheet metal enclousre for fixing SPN-4way DB including all necessary accessroies complete all as specified and directed. |
| 44 | S&F Wiring complete with 1.5 sqmm single core PVC insulated, sheathed FRLS 1100 volts grade,FRLS cable and incl PVC conduitwith accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with modular frame with cover etc and 1.5 sqmm PVC insulated, sheathed copper conductor multistrandedcable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for |
| 45 | One light point/fan/bell point controlled by one switch |
| 46 | S&F modular switch 1 way 6 Amps, 1 module complete all as specified and directed. |
| 47 | S&F white cover plate with frame, 6 Module complete all as specified and directed. |
| 48 | S&F metal flush box 6 module complete all as specified and directed. |
| 49 | S&F electronic modular fan regulator 230 volts, step type socket type, hum free 120 watt 2 Module complete all as specified and directed. |
| 50 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five starrated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 51 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and directed.Note: The rate including civil work wherever necessary. |
| 52 | S&F Flame proof Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl Stove enemelled steel conduitwith accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to wallsand 1.5 sqmm PVC insulated, unsheathed copper conductor multistrandedcable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for |
| 53 | One light point/fan/bell point controlled by one switch |
| 54 | S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. |
| 55 | S&F Flame proof class 1 zone 1 weather proof wall mounting fan 15\" (380mm) sweep 1440 RPM single phase suitable rated 240 volts 50 cycle with CMR/CPRI hazardous area gas group IIA/Iib with fabricated construction casing suitable propeller wheel with dynamically balanced blades to avoid frictional spark hazardous front and rear wire guards 01 No, M-20 cable entry etc suitable for wall/bracket mounting arrangement etc duly dark grey epoxy powder coated as per shade 632 of IS-5 complete in all respect including wiring MES No 2 CM height with synthetic enamelled black paint all as directed.Note:- Necessary Civil work is included in quoted rate. |
| 56 | S&F junction box dia 120x70H all as directed. |
| 57 | Taking down carefully of any type point wiring light fans socket or power complete fitting such as switch ceiling roses, pendent, regulator, sockets etc removing material and making good disturb surface of wall floor etc complete all as direct by Engr -in -charge. |
| 58 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary of capacity1.5TR complete all as specified and directed. |
| 59 | Supplyand fix voltage stabilizer for automatic operation single phase naturally cooled indoor type & designed for input variation between 170V to 250V with output voltage stablized at 230V with accuracy of +2.5% and of capacity4 KVA complete all as specified and directed. |
| 60 | S&F sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cable drawn through and including metalic steel conduit and conduit accessories consealed in wall,ceiling etc. ISI marked32mm dia(external) with wall thickness not less than 1.8mm with conduit accessories fixed on wall/roof and one run of 4 Sqmmsingle core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 volts grade cableas earth conductor complete as specified. |
| 61 | S&Fsinglepole MCB 6 to 32 Amps, 240 v, 50 Hz ACsuitable for exisiting loads(curve shall beprovied as per existing loads 10 KA breaking capacity conforming to IS 8828 of 1996all as specified. |
| 62 | S&F Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. incl making good to the disturbed surfaces complete all as specified. |
| 63 | S&F 1-ph,two pin with earth, metal clad earth plug socket with sheet metal enclosure controlled by Single pole MCB 5 to 32(selection of MCBrating & its load curve should be match with load) Amps-01 No capacity operating on 230 V AC 50Hz electric supply complete ,including making good all disturbed surface etc complete all as specified and directed.. |