| 1 | M & L for repairs to pot holes not exc 1 Sqm each, incl sweeping free from dust and mud or water scoring sunken surfaces in roads, path etc. cutting around edges to at least 25 mm in depth, making good by filling in screened and graded road metal, watering and well ramming the surface complete all as specified and directed. |
| 2 | M & L for preparing existing black top surface by brushing with wire brushes for removing cacked mud etc. scarifying or picking up gravelled macadam/bituminious macadam in area exc 400 sqm and n.exc 50mm deep, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc and applying evenly a priming/ tack coat with paving bituminous primer VG-10 grade at 7.50 Kg per 10 Sqm for below BM surfaces. |
| 3 | M&L for premix bituminous macadam with 4% binder content (paving bitumen grade VG-30/ laid/rolled and compacted using 8 to 12 tonne power roller to required gradient and camber (consolidated thickness n.exc. 50mm) all as specified and directed. |
| 4 | M&L for preparing black top surfaces by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc. and applying evenly a priming/tack coat with paving bitumen VG-10 @5 kg per 10 sqm complete all as specified and diirected. |
| 5 | M&L for bituminous premixed semi dense asphaltic concrete 30 mm consolidated/ compacted thickness using hot mix plant and mechanical paver with 5.50% (paving bitumen VG-30 grade) binder content by weight of total mix, rolled and compacted using 8 to 12 tonne power roller to required camber and gardient complete all as specified and directed.Note:- The work shall be executed using Hot mix plant and mechanical paver. |
| 6 | M & L for Marking strips, straight lines, zebra crossing and straight lines not less than 2mm thick and exc 10 cm width with hot applied thermoplastic road marking paint of approved brand (White or yellow) by using automatic mechanical road painting machine with 8% glass beads (intermixed) all as specified and as directed by Engineer-in-Charge. |
| 7 | Supply and fix solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono crystalline solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed. |
| 8 | S & F Cat eyesolar reflective type of metal body alloy of size 100mmx100 mmx20mm with PMA striplensreflector of modelNo DA 972 fixed withand incl MS stud of suitable size as per manufactures instructions Complete all as specified and as directed. |
| 9 | Dismantling of road furniture i.e cat eye & solar cat eye etc |
| 10 | Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc.15 cm thickness (below or above ground level) and removing from site all as specified and directed. |
| 11 | Demolition of Concrete of any description and in any position not otherwise specifically provided and removing from site all as specified and directed. |
| 12 | Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar. |
| 13 | M&L for 75mm thick plain cement concrete type D-2, 1:4:8 using 40mm graded stone aggregate as in floor complete all as specified directed. |
| 14 | M&L forprecast concrete interlocking paver rubber moulded glossy finish block of shape colour and sizeas approved by GE with grey cement and pigment confirming to IS 15658-2006 of 60mm thickness, M-35 Gradeall as specified. |
| 15 | Fixing only interlocking paver block of any shape , size and thickness, completed all as specified.Note: Reuseable interlocking paver block retrieved from item No-12 above shall be reused after necessary cleaning all as directed by Engr--in charge |
| 16 | M&L for 25mm thick sand filling under as in flooring under interlocking tiles complete all as specified and as directed. |
| 17 | M&L Cement concrete type B1 1:2:4 (20 mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 18 | M&L factory made kerb stone of M-25 grade cement concrete in position to the required line,level and curvature,jointed with cement mortar 1:3 including making joints with or without grooves(thickness of joints except sharp curve shall not tobe more than 5mm) including making drainage opening wherever required complete of design as approved by GE complete all as specified and as directed |
| 19 | M&L for preparing newconcrete/plaster surface of any description not otherwise described over 10cm width or girth strips and applyingtwo coats of synthetic enamel paint over a coat of priming paints plaster /concrete surface complete all as specified and as directed. |
| 20 | NOTE : SCHEDULE OF CREDIT (Amount on page No 25 shall be deducted offline from the total quoted amount to arrive at the net contract sum to be considered for acceptance.) |