| 1 | Supply and fixing in replacement of DOL starter , singlephase starter with relay capacity 2.5 to 10 Amps suitable for pump set of capacity up to 2 HP complete all as specified and directed . |
| 2 | Supply and fixing in replacement of DOL starter , three phase starter with relay capacity 9.5 to 20 Amps suitable for pump set of capacity up to 5 HP complete all as specified and directed . |
| 3 | Opening gland bracket/plate from pump setor sluice valve from gland hose of any type and capacity and fixing suitable size gland bracket/plate to avoid leakage of water from sluice valve and pump set complete all as specified and directed . |
| 4 | Supply and fix in repair/replacement of PVC foot valve of size 100 mm dia including removing old U/S foot valve complete all as specified and directed. |
| 5 | All as per item No 05 here-in-before but 80 mm complete all as specified and directed . |
| 6 | Material and labour for preparing surfaces ofstarter panel /LT panel forPump set of any capacity pumpby scraping, removal by hard iron brush of existing paint and applying two coat of synthetic enamel paint over a coat of red oxide zinc chromate primer complete all as specified and directed at site |
| 7 | Disconnecting the three phase electric supply from panel board and taking out the burned panel board wiring ,removing the unserviceable parts like ,Contactor, relays, timers, push button, NO/NCvolt coils, Thermal over load relays etc and replace the same which be required to make 100% serviceable of starter upto 12.5 HP- 03 Noscomplete all as specified and directed . |
| 8 | Supply and fix in repairs on wall/concealed on wallhigh pressure CPVC pipes 100 mm inner dia schedule-40 & plain schedule 80 fittings and jointed with CPVC yellow solvent cement, fixed to wall/ceiling or laying in floor includingtaking down old PVC/PPR/GI tubingcomplete all as specified and directed . |
| 9 | Supply and fix on wall/concealed on wallhigh pressure CPVC pipes50 mm dia SDR-13.5 & plain CPVC SDR 11 fittings and jointed with CPVC yellow solvent cement, fixed to wall/ceiling or laying in floor includingtaking down old GI tubingcomplete all as specified and directed . |
| 10 | All as per item No 09here in before but of size 25 mm diacomplete all as specified and directed . |
| 11 | Dismantling the submersible motor 3 phase ,50 Hz ,415 volts AC of 1HP to 7.5 HP capacity and taking out the defective Gun metal bush, thrust bearing including taking out by cutting the brunt out winding.Cleaning the winding core thoroughly by scrapping/washing and make the core suitable for re-winding.Rewinding the motor with water proof PVC insulated copper winding wire of existing gauge and size.Carry out necessary Machine work to motor shaft all as requiredincluding necessary sparescomplete all as specified and directed . |
| 12 | Supply , Installation, testing and commissioning in replacement ofof vertical outdoor type floor mounted self supporting pressure sand filter (totally anti corrosive),diameter of filter2200mm, height of filter 2200mm made out of FRP, with thickness as specified by the manufacturer for Sea Water Treatment and as per latest IS, dished ends complete with UPVC (un plasticized PVC and poly propylene) face piping ABS plastic with manual snap, dump drain valve, water drain valve, fitted with pressure gauge, sample cock, air vent , empty plug and all connected accessories as required the existing site for entire functionality of filtration plant with fully satisfaction with necessary piping connection with filter, necessary provn of valve of suitable size and necessary foundation and all piping joints, bends, elbow, tee , flange etc all accessories as required at site for 300 TPD RO Plant completeall as specified and directed with the following:-(a) Flow rate 30 m³/ Hr(b) Vessel dia-2200mm(c) Vessel height-2200mm(d) Max operating pressure- 10 bar.(e) Volume- 3218 Ltrs(f) Liner material LLDPE(g) Valve Battery Manifold made in PVC with flanges for connecting to filters as per DIN 2501 standards.(h) Provn of set of 5 Nosvalves for carrying out filtration, back-washing, rinsing and shut down of the filters.Note: - (i) Make and drawings for filter vessel layout shall be approved by GE before placement of order.(ii) colour coding of pipe lines with arrow marking shall be done after completion of connections.(iii) Cost of UPVC pipes inter connection inside filter up to inlet or outlet side Header with connected items and pressure gauge shall be deemed to be included in the quoted rate. |
| 13 | Supply, Installation, Testing & Commissioning in repalcement of Programmable Logic Controller based Pump Automation and Protection Panel suitable for control & monitoring the function of following :- (a) Upto 04 Nos pumps, (b) Upto 04 Nos Volt and Amphere meters, (c) Upto 10 Nosmotorized valves, (d) Upto 04 NosPressure transmitters, (e)Upto 09 Nossolenoid valves (f)Upto 12 NosMagnetic sensors. The panel shall consist of the following equipments :- (i)PLC with suitable Digital and analogue Inputs / outputs, expansion modules, RTC . (ii) 4\" LCD HMI(iii)Transformer with regulated output voltage of 230V +/-5%, (iv)SMPS of Suitable rating(v)Set of Control Relays and suitable MCB(vi)Audio visual generator (vii)Suitable No. of LED Indicators for easy visualisation(viii) SelectorSwitches (ix) Push Buttons / Illuminated Push Buttons (x) 0.5 sqmm multistrand internal wiring with ferruling and suitable lugs.(xi)Ethernet card (xii) Media Converter (xiii)Ethernet Switch(xiv)LIU(Light Interface Unit)box patch chord and mounting accessories with following specification.Communication: Primary- OFC, Stand by: GPRS (xv) PLC shall be upgraded and reanulated with the existing SCADA system. |
| 14 | Supply, Installation, Testing and Commissioning in repalcement of Programmable Logic Controller based Pump Automation and Protection Panel suitable for control and monitoring the function of following :-(a) 05 -07 Nos pumps, (b) 05 -07 Nos Volt and Amphere meters, (c) 11 to 16 Nosmotorized valves, (d) 05 -07 Nos Pressure transmitters, (e)10 - 17 Nossolenoid valves (f)13 - 25 NosMagnetic sensors. The panel shall consist of the following equipment :- (i)PLC with suitable Digital and analogue Inputs / outputs, expansion modules, RTC . (ii) 4\" LCD HMI(iii)Transformer with regulated output voltage of 230V +/-5%, (iv)SMPS of Suitable rating(v)Set of Control Relays and suitable MCB(vi)Audio visual generator (vii)Suitable No. of LED Indicators for easy visualisation(viii) SelectorSwitches (ix) Push Buttons / Illuminated Push Buttons (x) 0.5 sqmm multistrand internal wiring with ferruling and suitable lugs.(xi)Ethernet card (xii) Media Converter (xiii)Ethernet Switch(xiv)LIU(Light Interface Unit)box patch chord and mounting accessories with following specification. Communication: Primary- OFC, Stand by: GPRS(xv) PLC shall be upgraded and reanulated with the existing SCADA system. |
| 15 | Supply and fix in replacement ofunserviceable DOL starter for borewell motor up to 5 HP three phase motor complete all specified and directed. |
| 16 | Supply and fix in replacement of CPVC flangesof Size 100 mm complete all as specified and as directed |
| 17 | Supply and fix in replacement of CPVC flanges of Size 80 mm complete all as specified and as directed |
| 18 | Supply and fix in replacement ofDigital three phase basicvoltmeter with ammeter ,class-1 with selector switch of range 0 to 500 volts of size 96 x96 mm complete all as specified and directed at site. |
| 19 | Supply and fix in repair/replacement ofIndicatorslamp ofColour : Red / Yellow / Green/Bluecomplete all as specified and directed . |
| 20 | Supply and fix MCB SP 6-32 Amps, 240 volt,10 KA \"C\" curve conect with lugsincluding removing old Unserviceable MCB complete all as specified and directed. |
| 21 | Supply and fix MCB SPN 32/40 Amps, 240 volt,10 KA \"C\" curve conect with lugs including removing old Unserviceable MCBcomplete all as specified and directed. |
| 22 | Supply and fix MCB TPN 63 Amps 240 volt, 10 KA \"C\" curve conect with lugs including removing old Unserviceable MCBcomplete all as specified and directed. |
| 23 | Supply and fixMCCB 4 pole , 63 Amp, 415 Volts 16 KA ,fixed type conect with lugs including removing old Unserviceable MCCB complete all as specified and directed . |
| 24 | Supply and fixMCCB 4 pole , 100 Amp, 415 Volts 16 KA ,fixed type conect with lugs including removing old Unserviceable MCCBcomplete all as specified and directed . |
| 25 | Supply and Fix inreplacement ofsingle phase preventor of any type of pump starter for protect of motor suitable for3 phase ,415 voltsof any capacity of pumpcomplete all as specified and directed . |
| 26 | Demolition of cement concretein ground floors and paving exc 15 cm thickness, above ground level) and disposal of debriscomplete all as specified and directed . |
| 27 | Material and labour for cement concrete in foundations, filling and mass concrete type 1:3:6 (40mm graded aggregate)complete all as specified and directed . |
| 28 | Material and labour for rendering 15mm thick on fair faces of brick work or concrete surface, including even & smooth finish (without using extra lime or cement) using cement plaster of 1:4complete all as specified and directed . |
| 29 | Material and labour, for cross arms, bracing, supports clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size indicated or directed and inclusive of one primer coat one under coat and one finishing coat of synthetic enamel paint(Blue colour) complete all as specified and as directed. |
| 30 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4 mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified including taking down of old item complete all as directedNote :-(i) Cost of GI pipe 40 mm and GI strip for length of upto 7.5 RM shall deemed to be included in the quoted rate and over and above shall be measured and paid separately. |
| 31 | Material and labour for Paste Multicolour Chart / single line diagramon particle board dully print of single line diagram ofdrawing shows distribution of pipe lines / Installation details/ equipment details /installation drtailsetc in multi colour complete all as specified and as directedNote :- Rough drawing /Details ( Hard copy) of equipment and plants will beprovided by Department. The contractor has to develop the same with legends/ signs as per the standards on computer in multicolour and same get it approved from Engineer in Charge. |
| 32 | Supply and fix in replacement of MS Pipe header 200 mm dia size 5 mtr. length with flanged ends closed with end plates not less than 16 mm thick fixed with nut & bolts with washers aned rubber gaskets with and including provision of following incomming and out going connections of length 450 mm with flanged end incuding painting with two coat of enamal paint over a coat of red oxide primer including brick mansonary support pillers of suitable size with PCC 1:2:4 in foundation, plastering around with 1.4 cm 10 mm thick and coping 10 cm thick and including connecting existing incomming & outgoing pipe lines and priming tank pipes alsoall as specified and directed by Engr-in-Charge. |
| 33 | Supply and fix in repair/replacement of Top Cover for electric Actuator for 50/75/100/150mm dia complete all as specified and as directed |
| 34 | Supply and fix in replacement of out door type feeder pillar box factory made out of 3 mm thick CRCA sheet and 40 x 40 x 6 mm angle iron frame front and back opening complete with locking arrangement, duly painted with two coats of powder coated paint over a coat of anticorrosive primer, grouted on PCC pillar, complete with comprising of the following incoming and out going arrangement complete all as specified and as directed :-(a)MCCB 4 Pole 40 Amps 18 kA - 01 No(b)Phase indication lamps with control MCB\"s - 01 Set(c)40 3P MCB 18 KA with 12.5/15 HP SDS Starter with Single phasing preventor, & ON/OFF/Trip IL - 02 Set(d)One blank compartment suitable for housing 7.5 HP SDS, MCB, SPP, etc |
| 35 | Supply and laying XLPE insulated, armoured heavy duty electric cable 25 sqmm 3.5 corewith aluminium conductor, 1100 volts grade, including copper lugs of suitable rating and disconnecting and taking down old U/S existingcable complete all as specified and as directed |
| 36 | All as per item No 35 here-in-before but 35 sqmm and 3.5 core complete all as specified and as directed |
| 37 | All as per item No 35here-in-before but 50 sqmm and 3.5 core complete all as specified and as directed |