| Sl. No. | Item Description |
| 1 | Demolition of rcc jali jaffri , cemented jalli , any type including taking out any section , including taking out embedded portion and making good disturbed ground all as specified and directed |
| 2 | M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed |
| 3 | M&L for 15 mm thick rendering in cement mortar 1:4 or fair faces of brick or cement concrete surfaces finished even and smooth without using extra cement complete all as specifed and directed. |
| 4 | S&F5mm thick ACPwall cladding sheet in colour as directed by Engr-in-charge fixed on MS frame . The size of each panel not exc 1.5sqm. MS frame to be fixed on walls, chajja and fasad with Min 08 Nos GI fastener 5\" long per 1.5 sqm, including all necessary repairing work as reqd, two coat of synthetic enamel paint over one coat of red oxide primer, including weather sealing sealent, masking tape, including cutting of V groves to fixing moulded ACP sheet self-tapping screw complete all as specified and directed |
| 5 | M&L forDholpur stone cladding gang saw cut 16-18 mmwith machine cut edges, uniform colour of each stone size notexceeding 0.25 sqm area and not exceeding 0.5 sqmfixed in cement mortar1:4with and including one number SS clamps (grade - 202) of flat-30mm X 2mm, 150mm long made to shape in each slab, making V groove at top and bottom of stone and drilling hole for hold fastener,polishing, rubbing & including silicon treatment complete all as specified and directed |
| 6 | M&L for Red sand stone jali gang saw cut 16-18 mmwith machine cut edges, uniform colour of each stone size not exceeding 0.5 sqm area fixed in cement mortar1:4withmade to shape in each slab, using red stone pattiat top and bottom of stone and Stone pillar for supporting of stone patti & Stone jali & including polishhing & rubbing. complete all as specified & directed. |
| 7 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.laid,bedded and pointed in any mortar complete all as specified and directed. |
| 8 | M&L for 16-18mm thick Granite slab on top of cooking plateform, bar counter and simillar work including cutting polishing rounding on edge etcmachine cut, bedded andjointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15mm thick screed bed in CM 1:4. including grinding and polishing complete all as specified and directed by Engr-In-Charge. |
| 9 | M&Lfor 16-18mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall with any height) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, cutting polishing rounding on edge etcmachine cut, bedded,jointed with grey cement slurry, pointed with white cement with admixture of pigment to match the shade of granite stone and holding with brass screw complete all as specified and directed by Engr-In-Charge. |
| 10 | S&F ifor 18-20mm thick exterior wpc wall cladding (Jalli) sheet of medium density in colour white or as directed by Engr-in-charge with computerized cutting as directed, fixed on MS frame. The size of each panel not exc 1.5sqm. MS frame to be fixed on walls, chajja and fasad with GI fastener 5\" long per 1.5 sqm, including all necessary repairing work as reqd, two coat of synthetic enamel paint over one coat of red oxide primer, including weather sealing sealant, masking tape, including cutting of V groves to fixing molded PVC sheet with S/S self-tapping screw complete all as specified and directed by Engineer-in-Charge. |
| 11 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge |
| 12 | M&L forvitrified ceramic tiles 9 to 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 15 mm thick screed in cement mortar 1:6 complete all as specified and directed by Engr-In-Charge. |
| 13 | M&L for Non skid ceramic coloured tiles size not less than 0.9 sqm and not exceeding 0.36 sqm 7 -8 mm thick in floors etc.Set and jointed in neat cemenbt slurry and pointed in white or coloured cement to matchand including over screed bed or bedding layer ofmortar15 mm thick laying floor finished in cement mortar 1:6 complete all as specifed and directed. |
| 14 | S&F lappato finish stone achieved through partial mechanical polishing using diamond abrasives (up to 800-1500 grit) to produce a soft sheen while retaining natural surface micro texture , should be installed using polymer modified adhesive , back buttered for full contact ,sealed before and after grouting and adequately protected until final completion, should be stain resistant, with mohs hardness about 6-7, compressive strength 100-250 MPa ,and including 15mm thick screed bed in CM 1:4. including grinding and polishing complete all as specified and directed. |
| 15 | M&L for preparing new/Old surfaces (plastered or unplastered) of walls and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed by the Engineer-in-Charge. |
| 16 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as directed by engineer in charge having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 17 | S & F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe 410-W (Gde E- 250) quality Acomplete all as specified and as directed. |
| 18 | M&L for two coats synthetic enamel paint over a coat of red oxideprimer on steel surfaces of any description not otherwise described over 10 cm width or girth including preparation of surfaces complete all as specified. |
| 19 | S & F Plates (plain or chequered)channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe 410-W (Gde E- 250) quality Aand fixing this base plates on RCC walls with iron fasteners of minm size 100mm with minm 4 fastener on each plates and welding iron of reqd size on the plates complete all as specified and as directed. |
| 20 | S&FGalvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of andard rails straining bolts, including, securing ortying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as rected (each line wire to be measured complete all as specified and as directed by the Engineer-in-Charge. |
| 21 | M&L PCC 1:2:4type B1 (using 20mm graded stone aggregate) mixed withwater proofing compound as per manufacturer instructions laid 40 mm thickness as in coping with surface finished even and smoothwithout using extra cement complete all as specified and as directed. |
| 22 | M&L Hardcore of gauge n exc. 63 mm, brocken bricks deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed |
| 23 | M&L for providing 75 mm thick cement concrete in 1:3:6 type C-1,(using 20 mm graded stone aggregate) finishing cement concrete surface even and smooth without using extra cement as in plinth protection complete all as specified anddirected. |
| 24 | Taking down cement plaster on brick or stone wall etc incl raking out joints hacking for key scrubbing down with water complete all as specifed and directed. |
| 25 | S&Fgalvanisedconcertina coil dia wire not less than 2.50 mm, coil dia not less than 610mm, zinc coating min 275 gm/RM, weight of coil not less than 1.40kg/Rm including securing and tying with galvanised mild steel wire staplesor steel pins etc including taking down old one complete all as specified anddirected. |
| 26 | M & L for brick work with sub-class `B\" bricks old size, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 27 | S&F for 2mm thick fibre glass reinforced translucent corrugated sheeting withtwo corrugated side lap fixed with L or J type or cranked hook bolts complete all as specifed and directed. |
| 28 | S&F in repair for 10-15mm thick exterior PVC OR WPC wall cladding (Jalli) sheet of medium denasity in colour white or as directed by Engr-in-charge with compterised numerical control (CNC cutting) as directed, fixed on MS frame. The size of each panel not exc 1.5sqm. MS frame to be fixed on walls, chajja and fasad with GI fastener 5\" long per 1.5 sqm, including all necessary repairing work as reqd, two coat of synthetic enamel paint over one coat of red oxide primer, including weather sealing sealant, masking tape, including cutting of V groves to fixing molded PVC sheet with S/S self-tapping screw complete all as specified and directed by Engineer-in-Charge.Note:-1.Work to be carried out up to four story bldg with MS scaffolding not bamboo. 2. MS frame should be fixed on wall after painting. |
| 29 | Material & Labourfor providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engr-In-Charge. |
| 30 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces (Cement plaster 1:6) finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge |
| 31 | M&L for preparation on existing treatment new/old surface of wall and apply 2 coat of plastc emultion paint over 2mm thick wallcare puttyover 10cm girth or width, not otherwise described complete all as specified and directed. |
| 32 | M&L for Prepolished chequered cement concrete tiles 30cmx30cmx25mm thick, set, jointed and pointed and in need cement slurry in floor with grey cement and pigment and including over screed bed or bedding layer ofmortar15 mm thick laying floor finished in cement mortor 1:6complete all as specified anddirected. |
| 33 | M&L for Non-SkidColoured Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles over 15mm screed bed exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, complete all as specified and as directed by the Engineer-in-Charge . |
| 34 | M&L for PCC 1:2:4 type B-0 (Using 12.5 mm graded stone aggregates) of 25 mm thickas in levelling course ,finished surfaces even and rough to receive floor finish complete all as specified and directed. |
| 35 | M&L for Vitrified coloured tiles(600mmx600mm)x9/10mm thick in skirting etc.Set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick plastering in CM 1:4 as in backing coat of tiles complete all as specifed and directed. |
| 36 | M&L forglazed ceramic coloured tiles/ light shade, premium quality tiles including designer tiles of size 350mm x 250mm x 7mm/450 x 350 x 7mm thick or as decided by EIC over and including 10 mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces or as in highlighter, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 37 | M&L for 5 mm thick rendering in cement mortar 1:3 on fair faces of ceiling or cement concrete surfaces finished even and smooth without using extra cement complete all as specifed and directed. |
| 38 | M&L for three coats of white wash on ceiling, soffit of staircase, chhajjas facia etc newly plastered surfaces including preparation of newly plastered surfaces or unplastered surfaces complete all as specified and as directed by the Engineer-in-Charge. |
| 39 | M & L Preparation ofnewly plastered or unplastered surface and applying two coats of distemper oil emulsion over acoat of primer on walls complete all as specified and directed. |
| 40 | M&L for complete removal of existing treatment of old decorated surfaces of walls by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down andstoping of existing surface and making the surface even and smooth and apply Two coats of distempering Ist quality acrylic distemper (ready mixed) having VOC content less than 50 gm/litre of approved manufacturer of required shade and colourover a coat of 1.50 mm thick (average) wall care putty to bring the surface even and smooth complete all as specified and as directed |
| 41 | M&L for complete removal of existing treatment of old decorated surfaces of walls by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down andstoping of existing surface and making the surface even and smooth and apply two coats of white wash on ceilings complete all as specified and directed. |
| 42 | M&L for complete removal of existing treatment machanically or mannually on old surface of wall and preparing surface and applying two or more coats 100 % acrylic based exterior emulsionpaint having VOC less than 50 gm/ltr and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt reistance 1st quality exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltr /10 sqm over and including priming coat of exterior grade primer applied @ 0.90 litre/10 Sqm including change of existing colour if required complete all as specified and as directed by Engineer-in-Charge.note; work will be executed upto fourth floor |
| 43 | Demolition of concrete of any description and in any position not otherwise specifically provided for.complete all as specified and directed |
| 44 | Excavation in trenchesn.exc 1.5m wide and n.exc1.5 min depthfor foundation, or shafts,wells, cess pits manholes, pier holes etcn.exc 10 Sqmonplanandn.exc1.5 min depthandgettingoutin anyhard / dense soilcomplete allasspecifiedanddirectedbyEngr-in-charge.Note:- Manual digging is permitted, if mechanical excavation is carried out by the contractor all damages of existing services shall be repaired by the contractor at his own expenses. |
| 45 | S&F 200 MM bore (inner dia) double wall corrugated HDPE pipes (SN8)in any length including all fittings and jointing with elastomeric rubber rings and couplers /other jointing materials as per manufacturers instructions,all as specified and directed. |
| 46 | M & Lforcutting in to existing manhole for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch camel ( 1/2round or 3/4 section) in cement concrete1:2:4 type B-1 smooth finished, and reforming benching as required of 150 mm/200mm/300mm dia of pipe completeallasspecifiedand directedbyEngr-in-charge. |
| 47 | M & L for concrete bed PCC 1:4:8 Type D2 (Using 40mm graded aggregate) to drain pipes 200 mm dia including packing under and hunching against the sides of pipes after they are laid and tested all as specified and as directed by Engr-in-Charge. |
| 48 | M & LforReturning & filling in including spreading, levelling, watering & well ramming in layers n.exc 25mm thick in soft/hard/ dense soil complete all as specified and directed by Engineer-in-charge. |
| 49 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed completeallas specified and directed by Engr-in-Charge. |
| 50 | S&F in repair precast factory made polycrete (SFRC) medium duty main hole / Drain covers 80mm thick rectangle in shape upto 0.60 sqm area for main hole/darin with at least 5cm bearing each sid complete all as specifed and directed |
| 51 | Demolition ofwall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets/board fixed in aluminium door or partition, any thickness, including cover fillets & framed work if necessary complete all as specifiedand directed. |
| 52 | S & F in\"E\" board (Design: Lake & hILL) MAKE: 605x605x4 mm thick, white pre laminated set embosed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped galvanised iron imposed grid with 24 mm wide T-sectionexposed flanges which shall be power coated white. The frame work shall be comprise of main runner made from 0.33 mm thickgalvanised steel sheet and of size 24 mm X32mmX300 mm board spaced at 120 mm maximum centre to centre, hangers of GI wire4 mm dia to be fixed by approved rawal plug level and fasterners and screws etc.,The last hanger at the end of each main runner shall not be greater than 450 mm from adjecent wall , flushing fitting of 1200 mm longer cross tee(with double stitching) to be interlocked between main runners at 600 mm centre to centre from 1200X600 mm modules cross tee longer than 600 mm to be supported independently . 600mm long cross tee centrally between the 1200 mm cross tee(with double stitching) to be interlocked between main runners at 600 mm centre to centre from 1200X600 mm modules cross Tee longer thyan 600 mm to be supported independently . The perimeter wall angle shall be 0.45 mm thick GS sheet of size 19 mm X 19 mm and 300 mm long of white colour all as per manufacturer\"s instructions complete all as specified and directed. |
| 53 | Taking down chowkats or frames with shutters (with out taking off shutters from the frames)not exc 1.5 Sqm each , incl removing.complete all as specified and directed by Engr-In-Charge. |
| 54 | S&F aluminium chequered grill of anodized section pf mesh100x100mm or80x80mm of 8/6/mm dia of bar fixed to frame with 20x20mm aluminium flat section with screw complete all as specified and as directed. |
| 55 | S&F for powder coated (minimum thickness of powder coating 50 micron) aluminum anodized three track slinding window with two or more shutter with 5 mm thick plane glass, one shutter of stainless steel mosquito proofing with good quality bearing ,handle lock,etc rubber beading and glazing clips etc using following sections as given in \"JINDAL\" catlogue etc as specified as per manufacturer instructions with the following size, complete all as specified and directed by Engr-in-Charge.Note : (1)Glass and wire not measured and paid separately however cost of all other connected accessories deemed included in unit rate. (2) faces of windows jamb should be given fair finish before fixing the window as per requirement of site |
| 56 | Taking down chowkats or frames with shutters (with out taking off shutters from the frames) exc 1.5 Sqm but n exc 4 Sqm each,incl removing complete and making good after fixing of new chowkat to match existing finish complete all as specified and as directed |
| 57 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45x85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length including making goodcomplete as per direction of Engineer-in-Charge: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extrapayment on this account shall be made. |
| 58 | S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) moulded decorative type door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 59 | S&F for Butt hinges of stainless steel 100mm size Heavy type complete all as spd and directed by Engr-in-Charge. |
| 60 | S&F for 150mm long stainless steel handles, fancy type, fabricated type. complete all as specified and directed. |
| 61 | S&F for 200 mm stainless steel, barrel tower bolts of extruded section and fixed complete all as specified anddirected. |
| 62 | S&F for Brass Mortice lock, vertical type, size 100mm 4 levers vertical with fancy handle (as decided by EIC) complete all as specified and directed. |
| 63 | S&Fin Door closer hydraulically regulated Aluminium (Die cast) body design No-3 universal type, suitable for door shutter of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed. Complete all as specified and directed by Engr-In-Charge. |
| 64 | S&F fordoor stopper of of brass body and tongue with hard drawn steel spring, (140mm size),complete all as specified and directed. |
| 65 | S&F for 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 66 | S & F in repair Aluminium door (single/double) leaf with anodized aluminium frame of section 62.5 x 37 x 2.5 mm thick, shutter with bottom & middle rail of section 112.50 x 37 x 2.5 mm thick and styles & top rail of section 83 x 37 x 2.5 mm thick with centrally locking arrangement with lock make of ‘GODREJ’ or ‘LINK’ 7 lever and self closing device with rebate includingjointingcleats, fixing of builders hardware fittings, necessary numbers of floor spring and glazing with 5.5 mm thick ordinary plain glass or alumium composite panel as per site reqr includingnecessary fittings, fixtures & aluminium snap beadsComplete all as specified and directed. |
| 67 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 68 | M&L cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 69 | S&F 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall including chesing& ceiling or laid in floors complete all as spd and directed by Engr-in-charge. |
| 70 | S&F 20mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors complete all as spd and directed by Engr-in-charge. |
| 71 | S&F for rotational molded polyethylene water storage tanks (white colour) of 500 ltrs capacity (cylindrical vertical with closed threaded top) hoisted and fixed in position including 20mm dia HD polythene float (ball) and epoxy coated aluminum rod (fly nut) screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 72 | S&F 15 mm pillar taps swan neck cast copper alloy, with capstan heads, chromium plated screwed down high pressure, with or without lettered \"Hot\" or Cold with long screwed shanks and fly nutsscrewed for iron pipes and fixed , fancy typecomplete all as specified and directed by Engr-In-Charge. |
| 73 | S&Fvitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolt, flushing cistern and flush pipe) including making goodcomplete all as specifed and directed. |
| 74 | S&F plastic water closet seat, black and white closed pattern with flat bottom and cover and mild steel chromium plated plated or aluminium hinging device complete all as specifed and directed. |
| 75 | S&Ffor 10 ltrs capacity PVC valve less syphonic action type flushing cistern low level white inlet ball valve, float , flush pipe and handle including brackets and fixedcomplete all as specifed and directed. |
| 76 | S&Fin for PVC connection 15mm dia and 600mm long complete all as specifed and directed. |
| 77 | S&F infor PVC waste pipe 32mm dia complete all as specifed and directed. |
| 78 | S&F invitreous china counter top wash hand basin of size 45cmx37cmx14.5cm white, ,complete all as specified and as directed by Engineer-in-Charge. (hindware Cat No.10104, or equivalent ) |
| 79 | S&F 32 mm dia brass chromium plated bottle trap complete all as specified and as directed |
| 80 | S&Ffor Vitreous china bowl urinal flat back size of 465X355X265 mm white (minimum) with grating and union for discharge pipe including flush pipe and waste pipe (excluding flushing cistern)complete all as specified and directed . |
| 81 | S&Ffor CP urinal spreader for fixing with 15mm dia pipe complete all as specified and directed. |
| 82 | S&F in half length wall hung urinal division of frosted glass of thick ness 8mm to 10mm, and size 600x1950mm complete all as specified and directed.(hindware Cat No.SU81CXF-06H19-CR 600 or equivalent ) |
| 83 | S&F in CP stop/angle valves, cast copper alloy, fancy type, chromium plated with long shank & cup (concealedtype) with crutch or butterfly handle, screwed both ends for iron pipe of 15 mm bore complete all as specified and directed by Engr-In-Charge. |
| 84 | S&F fancy type mirror of8 to 10 mm thick glossy glass decorative/ designer type, any size and shape bevelled edges all-round as decided by EIC, wall mounted mirror complete all as specified and directed by Engineer-in-Charge. |
| 85 | S&F infor brass CP towel railof 15mm dia with hook 600mm long complete all as specified and directed by Engr-In-Charge. |
| 86 | S &F in Toilet paper holder with flat recessed type stainless steelcomplete all as specified and directed by Engr-In-Charge. |
| 87 | S&F inCP bib taps long body , cast copper alloy, fancy type with with wall flange, chromium plated, screwed down to iron pipes or for brass ferrule of 15 mm borecomplete all as specified and directed by Engr-In-Charge. (hindware Cat F360004SCP or equivalent ) |
| 88 | S&F InHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hookincluding making connections and fixed in position complete all as specified and as directed |
| 89 | S&F in 15mm dia CP jet with CP flexible pipe 90cm long incl necessary fittings complete all as specified and directed . |
| 90 | S&F as in liquid soap dispenser with s/s metallic bottle complete, all as specified and directed by Engineer-in-Charge. |
| 91 | Demolition of cement concrete in ground floor and paving n.exc 15 cm thick (below or above ground level) etc complete all as specifed and directed. |
| 92 | M&L for Sand filling under floors or in foundationincluding watering and consolidationcomplete all as specified and directed. |
| 93 | M&L for 60mm thick, M-30 Grade Machine pressed precast concrete interlocking paver block any shape and size casted in plastic moulds and compated on vibratory table confirming to IS 15658-2006 with grey cement and pigmentcomplete all as specified and directed. |
| 94 | M&L for PCC 1:2:4 type B-0 (Using 12.5 mm graded stone aggregates) of 25 mm thickas in leveling course ,finished surfaces even and rough to receive floor finish complete all as specifed and directed. |
| 95 | S&F110mm bore PVC (SWR) pipe single socketed any length with rubber ring joints laid in trenches or in floor including taking down complete all as specifed and directed. |
| 96 | S&F PVC (SWR) bends any radius 110mm bore pipeincl taking down complete all as specifed and directed. |
| 97 | S&F75 mm bore PVC (SWR) pipe single socketed any length with rubber ring joints laid in trenches or in floor including taking downcomplete all as specifed and directed. |
| 98 | S&F75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 99 | Demolition of brick work built in cement mortar including all quains, arches, pillers etc andremoving debriesout site MOD landcomplete allasspeifiedand directedbyEngr-in-charge. |
| 100 | S &F \"Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners not paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extrapayment on this account shall be made. \" RM 25.00 960.30 24007.50 8100E |
| 101 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete includung 20 mm screed bed in cement mortar 1:6 complete all as specified and directed. |
| 102 | M&L for Point wiring using approved colour coding as per IS, with stranded copper conductor1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed stranded cable 1100 volts grade (FRLS),ISI-694 markedin and including heavy duty, PVC concealed conduit after cutting,chasing the wall etc and making good of disturbed surface, including all accessories etc, heavy duty ISI marked, includingmild steel sunken boxes with earth dolly duly powder coated suitable for modulater plates of required size, covered with modular plates, suitable for modular switches, sockets etc including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) (FRLS) single core cable as earth continuity conductor to common earth and connecting to earth dolly. ( Note- Modular Switch and sockets will be measured and paid seperately).(a) For one light/fan point controlled by one SP switch |
| 103 | All as per item No-102 above but for one 3 pin socket out let, 6 Amps on same board |
| 104 | All as per item No-102 above but for one 3 pin socket out let, 6 Amps on Independent board |
| 105 | All as per item No 102 above but with 2.5 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including Single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire 2.5 sqmm FRLSall as specified and directed by Engineer-in-Charge. ( Only one 15 Amp point will be in one circuit) |
| 106 | S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. |
| 107 | S & F Modular Socket, 6A -3 pin combined 2 module,suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. |
| 108 | S & F Modular switch 1 way 16A ,1 module suitable for 240 Volt AC complete all as specified and directed by Engr-in- Charge. |
| 109 | S & F Modular Socket, 16A -3 pin combined 2 module,suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. |
| 110 | Supply and fix electronic Fan Regulator rotary flush step type 120 watt, 240 volt complete all as specified and directed by Engineer-in-Charge. |
| 111 | Supply and fixing ofceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round blockcomplete all as specified and directed by Engineer-In- Charge. |
| 112 | Supply and fixingin replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCAmild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge.Note :- MCB shall be measured and paid seperately. |
| 113 | Supply and fixingin replacement load line vertical distribution boardmade out of CRCA sheet,double door, surface mounting TPN 8 way 415 volts suitable sizebus bar and stove enamels dust and vermin proof suitable for TP/FPincomer MCCB of 160 Amps complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Cutting ,chasing andmaking good of disturbed surface with existing colour painting also included in the unit quoted rate of item.(ii) MCB and MCCB shall be measured and paid seperately. |
| 114 | Supply and fixing of 3 pole MCCB 160 Amps, 50 HZ, 415 volts with rupturing capacity 16 KA, ,Ics=100%Icu, complete all as specified and directed by Engineer-in-charge. |
| 115 | S&F MCB TP25 to 63 Amps 10 KA, 240 volt50 HZ \"B\" Series all as specified and directed by engineer-in-charge. |
| 116 | S&F MCB SP 6 to 32 Amps 10 KA, 240 volt \"B\" Series all as specified and directed by engineer-in-charge. |
| 117 | S&F MCB SPN40 Amps 10 KA, 240 volt50 HZ \"B\" Series all as specified and directed by engineer-in-charge. |
| 118 | Supply and fixing LEDbatten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cablefrom ceiling rose to fitting,and testing complete all as specified and directed by the Engineer- In- Charge. |
| 119 | Supply and fixing LEDbatten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cablefrom ceiling rose to fitting,and testing complete all as specified and directed by the Engineer- In- Charge. |
| 120 | S&F of exhaust fan heady duty metal body type 300 mm sweep with blades, and frame and louvers includingnecessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge. |
| 121 | S&F of wall mounting fan heady duty 400 mm sweep including necessary fixing arrangement for proper fixing on wall as per site requirement complete all as specified and as directed by Engineer-in-Charge. |
| 122 | Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.complete all as specified and directed. |
| 123 | Supply and fixed Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 25 Amp MCB complete all as specified and directed. |
| 124 | M & L for in submain wiring with four run of 6.0 sqmm singlecore PVC insulated butunsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts gradeIS:694 marked and two run of 6.0 sqmm PVC insulated butunsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked complete with all acessories and fittingsall laid/fixed concealed in wall and surface conduit on ceiling portion only complete all as specified .(Note:- 6 Runs of 6.0Sqmm and one run of PVC conduit will be used as one unit for measurement purpose) . |
| 125 | M & L for submain wiring with two run of 4.0 sqmm singlecore PVC insulated butunsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts gradeIS:694 markedand one run of 6.0 sqmm PVC insulated butunsheathed FRLS cable for earth continuty conductor drawn throughsuitable size of rigid non metallic PVC conduit , medium grade, ISI marked complete with all acessories and fittings concealed in wall including making good of disturbed surface with existing colour painting and on surface conduit above falseceiling, complete all as specified .( Note : 3 runs of cable and conduit will measured one unit for payment purpose. |
| 126 | Supply installation commissioning testing of earthing in any kind of soil/strata complete with copper bonded earthing electrode chemical earthing system outer electrode dia 50 mm and 3 mtr long tightly filled with crystalline conductor mixture 250 microns copper coated along with bag of back bill compound 50 kg buried directly in the ground (earth pit not less than 2.25 meter deep below ground level) connected to and including galvanized iron strip 25 X4 mm as earth strip by means of GI bolts,nuts,check nuts and washers and connecting earthing test point ,including CI covers ,frame and PCC (1:3:6) type C-2 using 20 mm graded stone aggergate as in earthing pit with CI cover and framing including necessary earth work etc complete all as specified .Note- PCC chamber shall be constructed at least one meter away from the building shall be provided in slanting manner.Note- PCC cover pit shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 kg (sqm in liew of CI) |
| 127 | Material and labour for galvanisediron strip 25 X 4 mm with saddles and fixing screws and connected as per site requirement complete all as specified and as directed by Engineer-in-Charge. |
| 128 | Supply, laying and testing ofXLPELT 1100 Volt Grade, armourd underground cable size of16 Sqmm 2 core with stranded aluminium conductorin trenches /passing through pipes/ on poles etc complele all as specified and directed. |
| 129 | M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm. |
| 130 | Supplying and laying un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm laid in in trenches as protection to cable all as specified and directed by Engineer-in-charge |
| 131 | Supply and laying GI pipe light grade galvanizedwith all fittings as required laid in trenches or fix on wall/pole for cable protection of 50 mm bore copmlete all as directed by engineer-in-charge. |
| 132 | S&F ultra modern design architectural design 36 watt 2x2 recess LED, 6000 K luminaire having glare free symmetrical illumination Complete all as specified and directed by Engineer-in-Charge. |
| 133 | Taking down including disconnectingthe electric connection of ceiling fan and dismantling blades,greasingcomplete all as specified and directed |
| 134 | Hanging / fixing only ceiling fan received from item No 19 above and connecting up with suitable size of copper cable from connector of fans to ceiling rose complete all as specified and directed. |
| 135 | Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with remote control complete all as specified and directed by Engineer-in-Charge. |
| 136 | M & L for in submain wiring with two run of 6.0 sqmm singlecore PVC insulated butunsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts gradeIS:694 marked and one run of 6.0 sqmm PVC insulated butunsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 25 mm dia) complete with all acessories and fittingsall laid/fixed concealed in wall and surface conduit on ceiling portion only complete all as specified .(Note:- 3 Runs of 6.0Sqmm and one run of PVC conduit will be used as one unit for measurement purpose) . |
| 137 | M&L forearthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate& copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plateNO 5 of SSR Part I (1991)and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all asspecifiedNote :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note:- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI) |
| 138 | Dismantling including disconnectingthe electric connection for split AC 1.5/ 2.0 TRindoor and outdoor unit and deposited in the store of AGE E/M complete all as specified and directed |
| 139 | Servicing,Installation,connecting of Split AC 1.5/2.0 TR received from item no 138 including gas charging if requiredand testing upto satisfaction of Engineer in charge complete all as specified. Note: Gas charging and minor parts replacement required at site also included in the unit quote rate of item. |
| 140 | S&F refrigerant linecopper tube1/2\"bore incl insulation of AC pipe complete all as specified and directed. |
| 141 | S&F refrigerant linecopper tube 1/4\" bore incl insulation of AC pipe complete all as specified and directed. |
| 142 | Supply & Fixing of flexible thredded pipe from indoor unit to main line size of 15/20 mm dia , fixing on wall by using clamps and screwing complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail