| 1 | Servicing/ Inspection of water cooler of any cap/type/make installed at different units at DGQA area Avadi on site including disconnecting electric and water connection of water cooler finding of defect including dismantling of compressor, relay, capacitor, thermostat, motor, PVC hose pipe, condensing coil including fixing new spares complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare parts required to make the water cooler serviceable shall be measured and paid separately under relavent items. (ii) All T&P charges for carrying the water cooler from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates.(iii)Repair/Replacement of minor items whose cost are less than 100/- Rupees is deemed to be included in the quoted rate.(iv) Rectifying, detecting the Gas leakage, Flexing, Pressuring,,vacumising, filling for charging of refrigerant gas shall be included in the quoted rate no extra cost paid to the contractor for the same. Refrigerant gas shall be measured and paid seperately under relevent item.(v) All the material will be procured by the contractor in advance and deposite in MES store for replacement. material directly replaced by the contractor will not be paid. |
| 2 | Supply and fixingHermetic compressor unit for water cooler of 40/80 ltr Complete all as specified and as directed by Engr-in-Charge. |
| 3 | Supply and fixing Hermetic compressor unit for water cooler of 60/120 ltr cap Complete all as specified and as directed by Engr-in-Charge. |
| 4 | Supply and fixing Hermetic compressor unit for water cooler of 150 ltr cap Complete all as specified and as directed by Engr-in-Charge. |
| 5 | Supply and fixing starting relay CAJ-2612 Complete all as specified and as directed by Engr-in-Charge. |
| 6 | Supply and fixing over load protection relay suitablefor any cap of water coolerComplete all as specified and as directed by Engr-in-Charge. |
| 7 | Supply and fixing starting capacitor 40-80 Mfd for any cap of water cooler Complete all as specified and as directed by Engr-in-Charge. |
| 8 | Supply and fixing starting capacitor 100-120 Mfd for any cap of water cooler Complete all as specified and as directed by Engr-in-Charge. |
| 9 | Supply and fixingthermostat suitable for any cap water cooler Complete all as specified and as directed by Engr-in-Charge. |
| 10 | Supply and fixing fan motor of capacity 1/10 to 1/35 HP 50c/s, 230 voltsComplete all as specified and as directed by Engr-in-Charge. |
| 11 | Supply and fixing PVC hose waste pipe with SS clamp suitable for water cooler of any capacity Complete all as specified and as directed by Engr-in-Charge. |
| 12 | Supply and fixing drain tray , stainless steel for water cooler of any cap complete all as specified and as directed. |
| 13 | Servicing /Inspection of refrigerators of any cap/type/make installed at different units at DGQA Avadi on site, finding of defect including dismentling of compressor, relay, capacitor, thermostat, motor, condensing coil , door, rubber gasket, ice box assembly including fixing new spares complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare parts required to make the Refrigerator serviceable shall be measured and paid separately under relavent items. (ii) All T&Pcharges and transportation charges for carrying the refrigerator from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates.(iii) Repair/Replacement of minor items whose cost are less than 100/- Rupees is deemed to be included in the quoted rate.(iv) Rectifying, detecting the Gas leakage, Flexing, Pressuring,,vacumising, filling for charging of refrigerant gas shall be included in the quoted rate no extra cost paid to the contractor for the same. Refrigerant gas shall be measured and paid seperately under relevent item.(v) All the material will be procured by the contractor in advance and deposite in MES store for replacement. material directly replaced by the contractor will not be paid. |
| 14 | Supply and fixing hermetic compressor unit for refrigerator of capacity 210-360. Complete all as specified and as directed by Engr-in-Charge. |
| 15 | Supply and fixing over load protection relay for refrigerator of any capacity any type Complete all as specified and as directed by Engr-in-Charge. |
| 16 | Supply and fixing starting relay for refrigerator of any cap/ any type Complete all as specified and as directed by Engr-in-Charge. |
| 17 | Supply and fixing thermostat for refrigerator of any capacity/any type Complete all as specified and as directed by Engr-in-Charge. |
| 18 | Supply and fixing PC Board for 270 to 360 ltrinverter refrigerator suitable make all as specified and as directed by Engr-in-Charge. |
| 19 | Supply and fixing timer for refrigerator complete all as specfied and as directed. |
| 20 | Servicing/ Inspection of AC window type of any cap/type/make installed at different units atDGQA area Avadi on site, finding of defect including dismentling of compressor, blower motor, evaporating coil, relay,thermostat,condensing coil , including fixing new spares complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare parts required to make the water cooler serviceable shall be measured and paid separately under relavent items. (ii) All T&P charges and Transportation charges for carrying the Window AC from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates.(iii) Repair/Replacement of minor items whose cost are less than 100/- Rupees is deemed to be included in the quoted rate.(iv) Rectifying, detecting the Gas leakage, Flexing, Pressuring,,vacumising, filling for charging of refrigerant gas shall be included in the quoted rate no extra cost paid to the contractor for the same. Refrigerant gas shall be measured and paid seperately under relevent item.(v) All the material will be procured by the contractor in advance and deposite in MES store for replacement. material directly replaced by the contractor will not be paid. |
| 21 | Supply and fixing rotary hermetic compressor unit for window air conditioner 1.5/2 Ton capacity,specifications as per existing Complete all as specified and as directed by Engr-in-Charge. |
| 22 | Supply and fixing reciprocating hermetic compressor unit for window air conditioner 1.5 Ton capacity, specifications as per existing Complete all as specified and as directed by Engr-in-Charge. |
| 23 | Supply and fixing Copper condensing coil for window air conditioner of cap 1.5 /2 ton capacity Complete all as specified and as directed by Engr-in-Charge. |
| 24 | Supply and fixing evaporating coil for window air conditioner of cap 1.5/2ton capacity Complete all as specified and as directed by Engr-in-Charge. |
| 25 | Supplyand fixing thermostat for window AC 1.5/2 ton as per existng make complete all as specifeid and directed. |
| 26 | Supply and fixing micron filter suitable for 1.5/2 Ton window AC Complete all as specified and as directed by Engr-in-Charge. |
| 27 | Supply and fixing blower motor for window air conditioner of capacity 1.5 /2 ton, type & specification as per existing Complete all as specified and as directed by Engr-in-Charge. |
| 28 | Supply and fixing for Window AC front grill complete as per existing for 1.5 Ton Complete all as specified and as directed by Engr-in-Charge. |
| 29 | M&L for repair only of old unsv PCB for window air conditioner of capacity 1.5/2 ton, complete all as specified and directed by engineer-in-charge . |
| 30 | Supply and fixing PCB for window air conditioner of capacity 1.5/2 ton as per existing model/ make complete all as specified and directed by engineer-in-charge . |
| 31 | Servicing / Inspection of AC Split type of any cap/type/make installed at different units atDGQA area Avadi on site, finding of defect including dismentling of compressor, blower motor, evaporating coil, relay,thermostat,condensing coil , including fixing new spares complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare parts required to make the water cooler serviceable shall be measured and paid separately under relavent items. (ii)All T&P charges and Transportation charges for carrying the Split AC from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates.(iii) Repair/Replacement of minor items whose cost are less than 100/- Rupees is deemed to be included in the quoted rate.(iv) Rectifying, detecting the Gas leakage, Flexing, Pressuring,,vacumising, filling for charging of refrigerant gas shall be included in the quoted rate no extra cost paid to the contractor for the same. Refrigerant gas shall be measured and paid seperately under relevent item.(v) All the material will be procured by the contractor in advance and deposite in MES store for replacement. material directly replaced by the contractor will not be paid. |
| 32 | Supply and fixing hermetic compressor unit for split air conditioner 1.5/2.0 Ton capacity and specifications as per existingcomplete all as specified and directed by Engineer-In-Charge. |
| 33 | Supply and fixing inverter duty compressor unit for split air conditioner 1.5 Ton capacity and specifications as per existingcomplete all as specified and directed by Engineer-In-Charge. |
| 34 | Supply and fixing Copper condensing coil for split air conditionner of cap 1.5 ton capacity, complete all as specified and directed by engineer-in-charge |
| 35 | Supply and fixing evaporating coil for split air conditioner of cap 1.5/2ton capacity, Complete all as specified and as directed by Engr-in-Charge. |
| 36 | Supply and fixing blower motor for outdoor unit of split air conditioner of capacity 1.5 ton, specification as per existing complete all as directed by engineer-in-charge |
| 37 | Supply and fixing PCB for split air conditioner of capacity 1.5/2 ton, complete all as specified and directed by engineer-in-charge . |
| 38 | Supply and fixing PCB for Inverter AC split typeas per existing make of capacity 1.5 ton, complete all as specified and directed by engineer-in-charge . |
| 39 | Supply and fixing thermostat for Split AC 1.5/2 ton as per existng make complete all as specifeid and directed. |
| 40 | Supply and fixing remote control for split/window AC of existing make Complete all as specified and as directed by Engr-in-Charge. |
| 41 | Supply and fixing swing motor, 230 v AC, 4-6 RPM for split/window AC of any make complete all as specfied and as directed. |
| 42 | Supply and fixing starting/ runningcapacitor 100-120 Mfd for any cap of Window/Split AC Complete all as specified and as directed by Engr-in-Charge. |
| 43 | Supply and fixingmicron filter suitable for 1.5/2 Ton split AC |
| 44 | Supply and fixing filter strainer brass/copper for 1.5/2 ton. |
| 45 | Supply and fixing fan motor for indoor unit of 1.5/2 Ton split ACComplete all as specified and as directed by Engr-in-Charge. |
| 46 | Supply and fixing water overflow PVC pipe heavy duty on wall/floor of size15mm dia for water drainage. |
| 47 | Supply and fix in replacement of copper tubing set 1/4\" and 1/2\" suitable for Split AC including PUF insulation and connected accessories, fixcing for outdoor unit for user requirement complete all as directed by engr-in-charge |
| 48 | Taking out and refixing at another location window type and split typeAC 1.5 Ton/2 Ton including making hole in wall required sizeand making good disturb surface including electrical connection complete all a specified and directed. |
| 49 | M & Lin replacement of split Air conditioner outdoor unit wall mounting stand for suitable size of 1.5/2.0 TR split AC including necessary fastener 100mm length complete all as specified. |
| 50 | Supply and filling refrigerant gas suitable for compressor of water cooler/Refrigerator/Deep freezer and AC of any type , make, capacity and type complete all as specified and directed by Engineer-in-charge. |
| 51 | Supply & fix in replacementPVC cable flexible round/flat 3 Core Copper conductor cable 6 sqmm including taking out old unsv burnt out cable complete all as specified and directed by Engineer-in-charge. |
| 52 | Supply & fix in replacementPVC cable flexible round/flat 3 Core Copper conductor cable 2.5 sqmm including taking out old unsv burnt out cable complete all as specified and directed by Engineer-in-charge. |
| 53 | S&F in replacement sheet metal powder enclosure powder coated versatile double door 2 way (SPN) distribution board for MCB provisions 230Volt, 50Hz AC with neutrallink , earth bar complete all as specified. |
| 54 | Supply & fix 3 pin Plug Top 15 Amp in replacement ISI Mark. |
| 55 | Supply & fix 3 pin Plug Top 5 Amp in replacement Complete all as specified and as directed by Engr-in-Charge. |
| 56 | S&Fin replacement MCBs single pole (SP) 5 to 32 Amps with 10 KA breaking capacity of \"C\" series in distribution boards Complete all as specified and as directed by Engr-in-Charge. |
| 57 | S&F in replacementMCBs single pole and neutral (SPN) 40 Amps with 10 KA breaking capacity of \"C\" series in distribution boards Complete all as specified and as directed by Engr-in-Charge. |
| 58 | Supply and fix in replacement push cock/ bib cock and stop cock unserviceable/damage push cock with new push cock, chromium plated, for 15 mm bore pipe internal/external thread, suitable for water cooler of any type and any capacity, complete al as specified and as directed by Engineer-In-Charge. |
| 59 | Taking out old unserviceable gate valve and supply and fix new 15 /20 mm dia bore gun metal gate valve conforming to IS with iron wheel head screwed both ends for iron pipe all as specified and directed. |
| 60 | Material & Labour in replacement ofold/unserviceablesub main wiringPVC insulated, unsheathed 2 single core cable 1100 volts grade withcopperconductor of size 4.0 sq mm (Nominal area) multi stranded drawn into conduit (Existing ) with and including 4 sqmm green stranded copper conductor as contineous earthwire withlugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured seperately. |
| 61 | Material & Labour in replacement of old/unserviceablesub main wiringPVC insulated, unsheathed 2 single core cable 1100 volts grade withcopperconductor of size 6.0 sq mm (Nominal area) multi stranded drawn into conduit (Existing) with and including 6 sqmm green stranded copper conductor as contineous earthwire withlugs complete all as specified and as directed.Note: New conduit and conduit accossories shall be measured seperately. |
| 62 | Supply andInstall Hi wall split Air Conditioner 1.5 TRcapacity withIndoor, outdoor unitscomplete cordless remote control unit and with in-built ioniser and plasma filter for better indoor air quality with minium 5 star rating and EER 3.2 ( Copper Condenser Coil) |
| 63 | Supply and fix in replacement of voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input varition between 90V to 260V with out put voltage stablized at 230v with accuracy of +/- 2.5% and capacity 5KVA |
| 64 | Supply and fix in replacement of voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input varition between 90V to 260V with out put voltage stablized at 230v with accuracy of +/- 2.5% and capacity 4KVA |
| 65 | M&L for servicing descaling with descaling agents (chemical solvent) for removing all silt/ rust of the solar water heater 300/500 LPD capacity solar water heating system and making good any leakages replacement of gasket etc testing complete and making the plant functional including replacement of minor spares parts for complete system (rubber gaskets 63mm dia , flange dummy 63mm dia, flange brass dia 63mm , hose clamps suitables sizes flange pieces, descaling agenst, glass rubberbeedings and if any minor spares reqd etc) complete all as specified and directed.Note:- Rates deemed to be included in minor spares as above mentioned and necessary civil works for structure base complete. |
| 66 | Supply and fix in replacement of heating elements for solar water heating system05 KW with rubber gasket for any type of geyser |
| 67 | M&L for hose pipe (EPDM) Size 25mm inner dia and 36mm outer dia suitable for solar hot water system incl taking down unsv complete all as specified and directed. |
| 68 | Supply and fix inreplacement of GI Pipe medium grade with insulation dia 20mm complete all as specified and directed. |
| 69 | Supply and fix inreplacement thermostat forSolar water heater, AC, SP 220 volts including making necessary connection, ISI marked, complete all as specified and as directed. |
| 70 | Supply and fix inreplacement of temparature gauge for water heating systemISI marked, complete all as specified and as directed. |
| 71 | M&L for attending minor complaints of window AC/ split AC of 1.5/2 Ton capacity at DGQA area complete all as specified and as directed by Engr-in-Charge. Note :- (i) Contractor will attend the complaint within 24 hrs if he failed to rectified the same a panelty of Rs 500 Per complaint will be charged from the contractor dues.(ii) Only one or twourgent complaints will be given to contractor for rectification and the same will be attend on priority. contractor will not demand for all the complaint in one day. |