| 1 | Dismantling old plasteror skirting raking out joints and cleaning the surface for plaster up to the height 7.0 M including disposal of rubbish to the dumping ground within 50 metres lead |
| 2 | Demolishing brick work in cement mortarmanually / by mechanical means includng stacking of serviceable materials and disposal of unserviceable materials within 50 meter leads as per direction of Engr -in- Charge |
| 3 | M&L Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor 2nd floor level in all shapes and sizes in cement mortar (1:4) complete |
| 4 | M&L 15mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete . |
| 5 | Distempring Two or more coats on new workover a coat wall primer with Ist quality acrylic distemper , having VOC ( Volatile Organic Compound) content less than 50 grams / litre of approved brand and manufacture of required shade and colour incluidngapplying 1mm thick wall care puttycomplete as per manufacturer\"s specification |
| 6 | Finishing wall New work ( Two or more coats applied @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 Sqm with 100 % premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade ( Company Depot tinted ) with silicon additives |
| 7 | Distempering on old work ( wall/ ceiling) ( one or more coats)with 1st qualityacrylic distember ( Ready mix ) having VOC content less than 50 grams/ litre of approved brand over a coat of water thinnable cement primerand manufacturer to give an even shade |
| 8 | Taking out doors, windows and clerestory window shutters ( steel or wood) including stacking within 50 metres lead :- (i) of area 3 Sqm and below |
| 9 | Providing and laying cement concrete in retaining walls, return walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, sunken floors etc upto floor five level excluding the cost of centering shuttering and finishing :- (i)1:2:4(1 cement : 2 coarse sand ( zone -III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources ) |
| 10 | Painting on new steel surface ( two or more coats ) including a coat of approved steel primer ( red oxide primer)with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade |
| 11 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar (1:3) (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete and dismantling tile 10 to 25 mm thick work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 12 | Providing and fixing factory made uPVC glazed and wire mesh windows comprissing of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.7 mm for Series R1 and R2 profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and inline sash adaptor (where ever required) of appropriate dimensions, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion ( if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections ofuPVC profiles to be as per desigh approved by Engineer-in-Charge. Three track three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70 mm & above) x (40mm & above) & both glazed and screen sash (25 mm & above)x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook , ,stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching andincluding proving &fixing glazing float glass panes of 5mm thickness ( weight not less than 12.50 Kg/ Sqm) indoor, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings and the directions of Enginer-in-charge. |
| 13 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVCprofile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cutand fusion welded at all corners, mullion (if required) shall be also fusionwelded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.Variation in profile dimensionin higher side shall be accepted but no extra payment on this account shall be made. Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wallthickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension,stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching andincluding proving &fixing glazing float glass panes of 5mm thickness ( weight not less than 12.50 Kg/ Sqm) indoor, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings and the directions of Enginer-in-charge. |
| 14 | Providing and fixing factory made uPVC glazed and wire mesh windowscomprissing of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.7 mm for Series R1 and R2 profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and inline sash adaptor (where ever required) of appropriate dimensions, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion ( if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections ofuPVC profiles to be as per desigh approved by Engineer-in-Charge. Fixed window / ventilator with mullion / transomUsing R2 series with frame (39 mm & above) x (39mm & above) & mullion (39mm & above) x 60 mm & above) (Height upto 1.2 metre) and ,stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching andincluding proving &fixing glazing float glass panes of 5mm thickness ( weight not less than 12.50 Kg/ Sqm) indoor, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings and the directions of Enginer-in-charge. |
| 15 | Providing and fixingsteel E165 (Fe 290) confirming to IS 2062 -2006 workin gratings, frames, guard bars, ladders, railing, brackets, purlings, gates and similar workswelded in built up sections / frames work, incluidng cutting, hoisting, fixing in position and applying priming coat of approved steel primer using structural steel as required |
| 16 | Providing Half brick masonry with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in super structure above plinth level upto floor 2nd floor level in cement mortar (1:4) |