| Sl. No. | Item Description |
| 1 | M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100 Volts grade, over head/ underground system along with necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- |
| 2 | Replacement of worn out jumpers, jointing and tightening with new ACSR conductor.Note:- Single phase/ two wire or 3 phase/ 4 wire system will be considered as one job for payment purpose. |
| 3 | Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and re-joining the same to restore electric supply. Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately.(ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable along with protection pipes. |
| 4 | Notes for Item Nos 1.01 to 1.02 :-(a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/ her for completion of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint.(b) A detailed log of complaints with completion/ non-completion remarks from users/ MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed.(c) The contractor will make suitable arrangement for emergency complaints and will notify auth rep/ Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard.(d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. |
| 5 | Notes for Item Nos 1.01 to 1.02 (contd...) :-(e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad.(f) The contractor will maintain location wise record of each spare utilized as per inventory format given by AGE E/M, Secunderabad and the same shall be submitted to E/M No II store on daily basis. |
| 6 | M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, including disconnecting/ taking out old existing Unsv insulators complete all as specified and directed. |
| 7 | M&L for Shackle type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 Volt grade, section of straps 31x5 mm, including disconnecting/ taking out old existing Unsv insulators complete all as specified and directed. |
| 8 | S&F in replacement Stay assembly comprising of 7/10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/ bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, up to 50m including disconnecting/ taking out old existing Unsv stay assembly complete all as specified and directed. |
| 9 | M & L for cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/ taking out old existing Unsv cross arms complete all as specified and directed. |
| 10 | Supply & Replace in replacement MCCB along with both side spreader link and nut bolts of appropriate size in existing LT Panel box/ Feeder Pillar boxes (KIOSK), in MCCB DBs of capacity 315-400 Amps, 4 Pole, 36 KA, 415 Volt including disconnecting/ taking out existing old Unsv/ burned MCCB complete all as specified and directed. |
| 11 | All as per item No 6.00 here in before but of capacity 250 Amps, 4 pole, 36 KA |
| 12 | All as per item No 6.00 here in before but of capacity 200 Amps, 4 pole, 36 KA |
| 13 | All as per item No 6.00 here in before but of capacity 160 Amps, 4 pole, 36KA |
| 14 | All as per item No 6.00 here in before but of capacity 125 Amps, 4 pole, 16 KA |
| 15 | All as per item No 6.00 here in before but of capacity 100 Amps, 4 pole, 16 KA |
| 16 | All as per item No 6.00 here in before but of capacity 63 Amps, 4 pole, 16 KA |
| 17 | Supply and fixing in replacement of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should be based on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off > 10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.The sensor along with suitable power contactors incoming outgoing MCBS SP and auto manual (sensor bypass selection option should be enclosed in a pole / wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 single phase load of 8 KW with circuit wiring min 10 sq mm copper wire 63 Amps contactor and suitable MCBs at both positions at incoming and out goings of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos) for fixing on pole / wall complete all as directed including taking down old one. Make: Model no Swadeep-02 EC 8KW 1P or equivalent from Havells/ Legrand. |
| 18 | Supply and fixing in replacement of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should bebased on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off > 10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. The sensor along with suitable power contactors incoming outgoing MCBS SP and auto manual (sensor bypass selection option should be enclosed in a pole / wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 three phase load of 12 KW with circuit wiring min 10 sq mm, 3 nos contactor each of 40 - 50 amps, incoming outgoing MCB (3 nos) rating 40 amps of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos) for fixing on pole / wall complete all as directed including taking down old one.Make: Model no Swadeep-02 EC 12KW 3P or equivalent from Havells/ Legrand. |
| 19 | M&L for repairing of automatic operation of high mast lantern including all arrangements required including crane and replacement of all unserviceable spares of high mast lighting system of height 12 m to 16 meter.Quoted rates deemed to be inclusive of the following:-(i) Crane as required for taking down of high mast pole including light without any damage to the mast, lantern and lights etc.and refixing the same after repairing of the all problem on the same position(ii) Necessary disconnection and reconnection of electrical connection.(iii) Replacement of all unserviceable spare like High mast head, high mast ring, stainless steel wire, clamp, winch, transition plate, service door, Hook ring, nose plate, cabinet, gear, reel, transmission belt etc.including servicing of gear box, filling of gear oil, greasing etc.complete (quoted rates deemed to be inclusive of all spares required for proper functioning of lantern system except stainless steel wire, High mast head, high mast ring etc. |
| 20 | Supply only steel wire rope 6mm dia (7/19 construction) suitable for high mast system including u bolt complete all as directed |
| 21 | Taking down, transport to workshop, Re-winding of electric motor 3 phase installed at high mast pole of capacity up to 2.2/ 3 HP and refixing of the same including necessary arrangement complete all as directed |
| 22 | Supply and lay in replacement of cable lay in trenches/ fixed to walls/ poles etc.connecting buy using lugs, testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor 4 Core 10 Sqmm complete all, as specified and directedNote :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately. |
| 23 | All as per item No 18.00 above but 2 Core 10 Sqmm |
| 24 | All as per item No 18.00 above but 4 Core 16 Sqmm |
| 25 | All as per item No 18.00 above but 4.0 Core 25 Sqmm |
| 26 | All as per item No 18.00 above but 3.5 Core 35 Sqmm |
| 27 | All as per item No 18.00 above but 3.5 Core 50 Sqmm |
| 28 | All as per item No 18.00 above but 3.5 Core 70 Sqmm |
| 29 | All as per item No 18.00 above but 3.5 Core 95 Sqmm |
| 30 | All as per item No 18.00 above but 3.5 Core 120 Sqmm |
| 31 | All as per item No 18.00 above but 3.5 Core 150 Sqmm |
| 32 | All as per item No 18.00 above but 3.5 Core 185 Sqmm |
| 33 | All as per item No 18.00 above but 3.5 Core 240 Sqmm |
| 34 | Taking out and Relaying of LT cable of size 10 sqmm to 50 Sqmm 2/ 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection by using Lugs all as specified and directed by Engr in charge.Note: Earth work, sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevant Item |
| 35 | Taking out and Relaying of LT cable of size 70 sq mm to 150 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge.Note: Earth work, sand Cushioning, brick protection, LT Joints shall be measured and paid separately under Relevant Item |
| 36 | Taking out and Relaying of LT cable of size 185 sq mm to 300 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge.Note: Earth work, Sand Cushioning, brick protection, LT Joints shall be measured and paid separately under Relevant Item. |
| 37 | Supplying, erecting and fixing in replacement of steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed.Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. |
| 38 | Restreching/ Restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and pruning of tree complete all as specified and directed.Notes:(i) The distance between pole to pole in one span (contains 2/ 4/ 6 runs) i.e.one span will only be considered for payment purpose.(ii) No Extra conductor will be measured for binding to insulators / jumpering etc. |
| 39 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/ dense soil for foundation of poles, structures, stay rods, laying of underground cable and laying pipes etc.complete all as directed by Engr-in-Charge. |
| 40 | All as per item No 35.00 above but depth exc 1.5 mtr but not exc 3 mtr. |
| 41 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed. |
| 42 | Removing excavated material (soils) n exc.50m and depositing where directed at a level n exc.1.5 m above the starting point complete all as specified and directed. |
| 43 | Spreading riddled earth (after preparation of excavated earth) in Cable duct with sand cushioning of cable laid in trenches complete all as directed by Engineer-in-Charge.Note:- Punned thickness 18 CM (6.25 Cm below cable and 11.75 cm above cable) will be measured for payment purpose.Quoted rate inclusive of all arrangement as mentioned. |
| 44 | Supply and Laying bricks, common burnt clay building bricks, sub class \"B\" of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed. |
| 45 | M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as directed |
| 46 | M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as directed |
| 47 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as directed |
| 48 | Cutting the existing road/ PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil up to 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. |
| 49 | M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc.as required at site complete all as specified and directed. |
| 50 | M&L repair/ maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed. |
| 51 | M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc.with 1 coats of aluminium paint including thoroughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles.Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed. |
| 52 | M&L for Painting the existing LT PCC poles with 1 coats of synthetic enamel base paint including painting of cross arms, clamps, etc.with one coat of aluminium paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 metres height, writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed. |
| 53 | M&L in replacement Advance Maintenance Free G.I.SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia (THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvanised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m.The GI Electrode shall be pre-filled with Crystalline Conductive Material (CCM).The GI electrode shall be surrounded with 25 kg Backfill compound to provide maximum contact between the electrode and Back Fill Compound.The earthing pit should be cover with pcc(1:2:4, B1) cover, of 450 x 450 mm complete all as specified and directed.Make: ASHLOK / INDELEC/ JMV / TERCEL/ True Power. |
| 54 | Trimming/ pruning and removing of tree branches or any other foreign objects from HT/ LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way / 4 way/ 6 way conductor system.Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule.(ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. |
| 55 | Cutting unaxious green growth and grass by manual labour or by machine at all 11 KV Electric Installation premises/ around 2/ 4 Pole structure/ along the boundary fencing and removing rubbish from the site of work complete all as specified and directed. |
| 56 | Supply and fixing in replacement of steel light bracket made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified. |
| 57 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspend ded by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat of Size 4 Sqmm complete all as specified and directed. |
| 58 | All as per item No 53.00 above but of size 6 Sqmm complete all as specified and directed. |
| 59 | All as per item No 53.00 above but of size 10 Sqmm complete all as specified and directed. |
| 60 | S&F in replacement of hot press moulded SMC junction/ terminal box of size with internal dimensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or Bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/ glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3 mm 2 Set including dismantling of old unserviceable all as specified and as directed.Make : Syntex/ C&S/ Havells. |
| 61 | Supply and laying in replacement of GI tubing light grade of size 40 mm for cable protection on road/ drain/ floor/ pole including necessary clamps 40x4mm with ISI marked. |
| 62 | Supply and laying in replacement of GI tubing light grade of size 50 mm for cable protection on road/ drain/ floor/ pole including necessary clamps all as specified and directed. |
| 63 | Supply and laying in replacement of GI tubing light grade of size 80 mm for cable protection on road/ drain/ floor/ pole including necessary clamps all as specified and directed. |
| 64 | Dismantling of damage / broken coping of PCC/ steel pole of any size and removing the debris from site complete all as specified and directed |
| 65 | Supply only of aluminium cable lugs of following sizes :-Make : Dowell/ Jaison. |
| 66 | 16 to 25 Sqmm Size |
| 67 | 35 to 50 Sqmm Size |
| 68 | 70 to 95 Sqmm Size |
| 69 | 120 to 150 Sqmm Size |
| 70 | 185 to 240 Sqmm Size. |
| 71 | Supply and fixing in replacement of lantern of dia 60 CM for fixing of flood light, cap type to be fixed on the top of 9 m SP-31 Steel pole, made of MS pip medium grade dia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nos including two coat of aluminium painting over a coat of red oxide primer complete all as directed |
| 72 | Material and labour for Taking down UNSV LED Lights and removing Carbon from its connector joints incl replacement of Connecting wire with new PVC sheathed weather-proof 3X single core cable for electrical connection and refixing the fitting after repair to its original/ New location or as directed by Engr-in-charge.(connecting wire will be measured and paid separately only) |
| 73 | M&L for preparation of old painted surfaces for outdoor/ indoor Amf panel/ LT Panel of any size with applying two coat of synthetic enamelled grey paint after removing all dust & rust and paint shall confirm to IS 2032 complete all as specified. |
| 74 | Supply and install, testing and commissioning of Out door LT feeder panel in replacement of, factory made cubicle type of suitable size and 3.15 mm thick CRCA sheet outdoor type vermin proof with Aluminium bus bar of suitable size Al strip 600 amps 3 phase and neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories are fitted on suitable insulator all housed in suitable bus bar chamber and provision and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps complete along with provision of necessary cable entry/ exit boxes for all incoming and out going cables with suitable cable glands incl PCC foundation etc.complete testing and commissioning complete and consisting the following :- |
| 75 | (a) MCCB 4 Pole 100 Amps 16 KA -01 No.(incomer)(b) MCCB 4 Pole 63 Amps 16 KA -04 Nos.(Outgoing)(c) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 600/ 5A LT-CT operated complete - 01 Set(d) Indicating type lamp for Red, Yellow and Blue phases - 01 SetNote : (a)All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc.the cost of work is deemed to be included in the above item..(e) The cost shall also be include the breaking of floors/ walls etc.including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces. |
| 76 | Supply, fixing, connecting and commissioning and testing of outdoor type (automatic and manual operation) power factor improvement panel of capacity 100 Kvar including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/ Indoor) type panel factory made, weather proof, dust and vermin proof suitable for 1100 V/ 440 V grade 3 phase 50 HZ AC supply floor mounted, fabricated out of 3.15mm thick CRCA sheet and having four Nos angle iron legs made out of 50 x 50 x 6mm 90 cm long angle iron below frame with front door and Side/ Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles, lugs duly painted with Siemens grey epoxy powder coating after suitable chemical treatment, legs duly embedded in ground up to 45 Cms in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting, with required sheet metal enclosures, thimbles with on line monitoring of Power Factor on web based application as specified and directed by Engr-in-Charge. |
| 77 | Incoming feeder:- |
| 78 | A.Incomer MCCB 160- Amp, Three Pole, Thermal based release with adjustable O/ L, Adj S/ C Setting Front Face, 16 KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 1 No |
| 79 | B.Metering Section- Digital Ammeter (0-150)Amps, digital Volt Meter (0-500)Volts, RYB Indicating Lamps, 1 Set Control fuses, CTs.3 |
| 80 | C.Insulated Busbar of Aluminium of 150A Capacity for 3 phase, , fixed on Insulators, Busbar Should be PVC Sleeved with red.Yellow.Blue Colour, Busbar Support should be of smc/ dmc - 1 set. |
| 81 | D.Multi 10 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display. |
| 82 | Outgoing feeder :- |
| 83 | E.Accessories for 5 KVAR heavy duty box type Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 5 kvar with Damping Resistors which limits inrush current 440 volt, 3phase, 50 hz, coil-220vac, MCB TP 10 A having breaking capacity 10 KA with std.duty capacitor on indicators and selector switch. |
| 84 | F.Accessories for 10 KVAR heavy duty box type Capacitor Bank - 3 Nos :- Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase, 50 hz, coil-220vac, MCB TP 20 A having breaking capacity 10 KA with std.duty capacitor on indicators and selector switch. |
| 85 | G.Accessories for 20 KVAR heavy duty box type Capacitor Bank - 3 Nos :- Capacitor Duty Contactor 20 kvar with Damping Resistors which limits inrush current 440 volt, 3phase, 50 hz, coil-220vac, MCB TP 63 A having breaking capacity 10 KA with std.duty capacitor on indicators and selector switch. |
| 86 | H.Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/ off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/ h flying leads |
| 87 | J.10 Steps Automatic Power Factor controller steps Relay Micro processor based for switching ON and OFF of capacitors to Display of voltage, current, Active power, apparent Power display of COS Ø, THD voltage, THD current, alarm indication for defective step, low power factor and axcess temperature.The relay having volt free c/ o contact, automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching program :LIFO combi Filter, manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt, 45 to 65 HZ, current measuring 10MA-5A suitable for CT x/ 1A and/ 5A commissing without additional setting and programming.Three decimal power reading.Phasing out of fault capacitor bank Automatically. |
| 88 | K. All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer.Note: APFC Panel shall be manufactured by original manufacturer only.The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. |
| 89 | Supply, fixing, connecting and commissioning and testing of outdoor type (automatic and manual operation) power factor improvement panel of capacity 70 Kvar including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/ Indoor) type panel factory made, weather proof, dust and vermin proof suitable for 1100 V/ 440 V grade 3 phase 50 HZ AC supply floor mounted, fabricated out of 3.15mm thick CRCA sheet and having four Nos angle iron legs made out of 50 x 50 x 6mm 90 cm long angle iron below frame with front door and Side/ Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles, lugs duly painted with Siemens grey epoxy powder coating after suitable chemical treatment, legs duly embedded in ground up to 45 Cms in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting, with required sheet metal enclosures, thimbles with on line monitoring of Power Factor on web based application as specified and directed by Engr-in-Charge. |
| 90 | Incoming feeder:- |
| 91 | A. Incomer MCCB 125- Amp, Three Pole, Thermal based release with adjustable O/ L, Adj S/ C Setting Front Face, 16 KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 1 No |
| 92 | B. Metering Section- Digital Ammeter (0-150)Amps, digital Volt Meter (0-500)Volts, RYB Indicating Lamps, 1 Set Control fuses, CTs.3 |
| 93 | C. Insulated Busbar of Aluminium of 150A Capacity for 3 phase, , fixed on Insulators, Busbar Should be PVC Sleeved with red.Yellow.Blue Colour, Busbar Support should be of smc/ dmc - 1 set. |
| 94 | D. Multi 10 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display. |
| 95 | Outgoing feeder :- |
| 96 | E. Accessories for 1 KVAR heavy duty box type Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase, 50 hz, coil-220vac, MCB TP 10 A having breaking capacity 10 KA with std.duty capacitor, on indicators and selector switch. |
| 97 | F. Accessories for 2 KVAR heavy duty box type Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3phase, 50 hz, coil-220vac, MCB TP 10 A having breaking capacity 10 KA with std.duty capacitor on indicators and selector switch. |
| 98 | G. Accessories for 5 KVAR heavy duty box type Capacitor Bank - 3 Nos :- Capacitor Duty Contactor 5 kvar with Damping Resistors which limits inrush current 440 volt, 3phase, 50 hz, coil-220vac, MCB TP 10 A having breaking capacity 10 KA with std.duty capacitor on indicators and selector switch. |
| 99 | H. Accessories for 10 KVAR heavy duty box type Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase, 50 hz, coil-220vac, MCB TP 20 A having breaking capacity 10 KA with std.duty capacitor on indicators and selector switch. |
| 100 | J. Accessories for 20 KVAR heavy duty box type Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 20 kvar with Damping Resistors which limits inrush current 440 volt, 3phase, 50 hz, coil-220vac, MCB TP 63 A having breaking capacity 10 KA with std.duty capacitor on indicators and selector switch. |
| 101 | K. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/ off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/ h flying leads |
| 102 | L. 10 Steps Automatic Power Factor controller steps Relay Micro processor based for switching ON and OFF of capacitors to Display of voltage, current, Active power, apparent Power display of COS Ø, THD voltage, THD current, alarm indication for defective step, low power factor and axcess temperature.The relay having volt free c/ o contact, automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching program :LIFO combi Filter, manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt, 45 to 65 HZ, current measuring 10MA-5A suitable for CT x/ 1A and/ 5A commissing without additional setting and programming.Three decimal power reading.Phasing out of fault capacitor bank Automatically. |
| 103 | M. All accessories prewired with suitable size copper Wire with stand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer.Note: APFC Panel shall be manufactured by original manufacturer only.The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. |
| 104 | M&L coarse aggregate 40mm graded deposited, spread and levelled complete all as specified and as directed for transformer yard. |
| 105 | Excavation in post holes (or similar holes) each n.exc 0.50 cu.m getting out in any type of soils, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm complete all as specified and directed. |
| 106 | M&L PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) in foundations, filling and mass concrete all as specified and directed. |
| 107 | M&L in repairs for mild steel works in fencing post and struts incl cutting tops to shape as directed, drilling holes, notching wire, etc., fillets (for securing wire mesh etc.) incl all necessary drilling bolting or riveting etc., and similar work conforming to Fe-290 Gde E-165 complete and incl dismantling old steel work all as specified and directed |
| 108 | Fixing only chain link fencing including line wires, any mesh size and type to any type of standards rails, straining bolts etc.including provision of binding wire including dismantling old unserviceable mesh all as specified and directed |
| 109 | Supply only 4mm dia chain link MS galvanised fencing wireand average size of mesh 50mmx50mm including line wires, to any type of standards rails, straining bolts etc., including provision of binding with mild steel wire annealed not less than 0.9mm dia including dismantiling old unserviceable mesh complete all as specified and directed. |
| 110 | Supply and fixing in replacement only power factor correction capacitor, 25 KVAR, heavy duty 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed. |
| 111 | All as per item No 74.00 above but 15 KVAR Capacitor Bank |
| 112 | All as per item No 74.00 above but 10 KVAR Capacitor Bank |
| 113 | All as per item No 74.00 here-in-before but 20 KVAR Capacitor Bank |
| 114 | Supply and fixing in replacement only capacitor duty contactor suitable for rating 25 kVAR, 50Hz, 440v, 3-ph, 3-pole in existing panel including necessary wiring & misc accessories for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.Make: Schneider/ L&T/ Siemens |
| 115 | All as per item No 78.00 above but 10 KVAR capacitor duty contactor |
| 116 | All as per item No 78.00 here-in-before but 20 KVAR capacitor duty contactor |
| 117 | S&F in replacement APFC relay with auto-set function 8/ 12 stage APFC relay |
| 118 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete. |
| 119 | All as per item No 82.00 here in before but 90 watts. |
| 120 | All as per item No 82.00 here in before but 100 watts. |
| 121 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 122 | All as per item No 85.00 here in before but 120 watts. |
| 123 | All as per item No 85.00 here in before but 100 watts. |
| 124 | Repair/ rectification of leakages to water supply distribution lines 15 mm bore to 25 mm bore GI/ PPR tubing with provision of necessary excavation, cutting of hard standing, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/ sockets/ nipples as required at site complete all as specified and directed. |
| 125 | All as per item No 88.00 here in before but for GI tubing 40 mm bore to 50 mm bore |
| 126 | All as per item No 88.00 here-in-before but for GI tubing 80 mm bore to 100 mm bore. |
| 127 | Attending routine complaints of external water supply including rectification of minor defects by taking down of existing GI/ PPR tubing up to 25 mm bore, cutting/ threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of jumper valve/ packing sheet of gate valve and including replacement of GI unions/ sockets/ nipples etc as required at site complete all as specified and directed. |
| 128 | All as per item No 91.00 here in before but for GI tubing 40 mm bore to 50 mm bore. |
| 129 | Attending complaints of BLOCKAGE OF WATER PIPE LINES / NO WATER SUPPLY AT ANY kind of ACCOMODATION (MARRIED / OTM/ single / multi story building) , IDENTIFY THE FAULTS including rectification by taking down of existing GI/ PPR tubing up to 80 mm bore, cutting/ threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of valve/ packing sheet of gate valve and including replacement of GI unions/ sockets/ nipples etc as required at site TO RESTORE WATER SUPPLY complete all as specified and directed. |
| 130 | Notes for Sl item No 88.00 to 93.00 :-(a) The contractor will be allotted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/ her for completion of day to day complaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint.(b) A detailed log book of complaints with completion/ non-completion remarks from users/ MES will be maintained by the contractor and the same will be updated on daily basis in consultation with JE E&M/ Engineer-in-Charge.(c) The contractor will make suitable arrangement for emergency complaints and will notify authorised representive/ Engineer-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard. |
| 131 | (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints.(e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad.(f) The contractor will maintain location wise record of each spare/ fittings utilized as per inventory format given by AGE E/M, Secunderabad and the same shall be submitted to E/M No II store yard on requirement basis.(g) The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor. j) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution.(k) Spares/ GI fittings required to be replaced and shall be measured and paid separately under respective items. |
| 132 | Rectification of leakages in pumping / delivery lines(CI/ DI/ PPR/ MS) of size 80 mm to 100 mm at Military area / Military Roads / civil Roads / PWD Roads / Cantt board roads by taking necessary permission from respective authorities by excavating PCC/ RCC/ pavement/ soft&hard soil/ rock of any depth by using necessary T&P(Excavator/ hammer drill)as per the requirement, De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/ tail peaces, any type of gasket, welding work etc as required to arrest the leakages completely and making joints, filling the trenches, site clearances and PCC at the top portion as required complete all as specified and as directed. |
| 133 | Rectification of leakages in pumping / delivery lines(MS/ CI/ DI/ PPR) of size 150 mm to 400 mm at Military area / Military Roads / civil Roads / PWD Roads / Cantt board roads by taking necessary permission from respective authorities by excavating PCC/ RCC/ pavement/ soft&hard soil/ rock of any depth by using necessary T&P(Excavator/ hammer drill)as per the requirement, De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DI specials such as collars, bends/ tail peaces, any type of gasket, welding work etc as required to arrest the leakages completely and making joints, filling the trenches, site clearances and PCC at the top portion as required complete all as specified and as directed. |
| 134 | Note for item 94.00 & 95.00 above:-(i)CI specials, lead Joints, D-Joints, Clamp joints, DI/ CI Pipe etc shall be measured and paid under respective items of sch \"A\".(ii) Rate of any kind of gasket and necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate.(iii) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required.(iv) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution. |
| 135 | M&L for attending break down of water supply pipe line at Military area / Military Roads / civil Roads / PWD Roads / Cantt board roads and repair s to CI/ DI/ PPR/ MS water mains of size 80 mm to 300 mm bore at a given notice including necessary excavation in mud, in any type of soil, PCC, RCC, hard rock etc by manual or using special T&P such as JCB etc.De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars, bends/ tail peaces etc and making joints complete all as specified and as directed including making good of disturbed surfaces. |
| 136 | Notes:-(i)CI specials, lead Joints, D-Joints, Clamp joints, DI/ CI Pipe etc shall be measured and paid under respective items of sch \"A\".(ii) Excavation and PCC will be measured and paid separately under relevant items.(iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required, deemed to be included in the quoted rate.(iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required.(v) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution. |
| 137 | Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for re-fixing or removal complete with all fittings and connections of the following sizes :- |
| 138 | 15 mm dia |
| 139 | 20 mm dia |
| 140 | 25 mm dia |
| 141 | 40 mm dia |
| 142 | 50 mm dia |
| 143 | Refixing of old steel tubing and connection in new or old position including fittings with old/ new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-Notes :- (a) Excavation and Earth work shall be measured and paid separately.(b) Necessary fittings shall be measured and paid separately. |
| 144 | 15 mm dia |
| 145 | 20 mm dia |
| 146 | 25 mm dia |
| 147 | 40 mm dia |
| 148 | 50 mm dia |
| 149 | Refixing of old steel tubing and connection in new or old position including fittings with old/ new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:- |
| 150 | 15 mm dia |
| 151 | 20 mm dia |
| 152 | 25 mm dia |
| 153 | Supply and laying steel water tubing medium grade, galvanised, laid in trenches and testing for leakages incl all necessary fittings complete all as specified and directed for the following sizes:-Notes :- (a) Excavation and Earth work shall be measured and paid separately. |
| 154 | 15 mm dia |
| 155 | 20 mm dia |
| 156 | 25 mm dia |
| 157 | 40 mm dia |
| 158 | 50 mm dia |
| 159 | Supply and laying steel water tubing medium grade, galvanised, fixed to wall and ceilings or laid in floor and testing for leakages incl all necessary fittings complete all as specified and directed for the following sizes:- |
| 160 | 15 mm dia |
| 161 | 20 mm dia |
| 162 | 25 mm dia |
| 163 | Taking up unserviceable/ defective CI/ DI/ MS water mains (including all fitting) with spigot/ socketed / flanged ends including disconnecting pipes and fittings in any position complete all as specified and directed for the following sizes:- |
| 164 | 80 mm Dia |
| 165 | 100 mm Dia |
| 166 | 150 mm Dia |
| 167 | 200 mm Dia |
| 168 | Refixing of old CI/ DI/ MS Pipe and connection after cleaning in new or old position including fittings with old/ new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:-Notes :- (a) Excavation and Earth work shall be measured and paid separately. |
| 169 | 80 mm dia |
| 170 | 100 mm dia |
| 171 | 150 mm dia |
| 172 | 200 mm dia |
| 173 | S&F ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/ 2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/ 2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/ DI/ MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:- Notes:- (a) Quoted rate is deemed to be inclusive of Push on Joints / D-Joints as required (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required.(c) Contractor is responsible for repair/ replacement of any damages to the existing structures, Under Ground HT/ LT/ OFC Cables etc during the course of execution.(c) Excavation and Earth work shall be measured and paid separately. |
| 174 | 100 mm Dia |
| 175 | 150 mm Dia |
| 176 | 200 mm Dia |
| 177 | Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:- Note: CI / DI specials, Joints and Earth work shall be measured and paid separately under relevant items of this schedule. |
| 178 | 80 mm Dia |
| 179 | 100 mm Dia |
| 180 | 150 mm Dia |
| 181 | 200 mm Dia |
| 182 | S&F GI fittings 15 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:- |
| 183 | Union |
| 184 | All equal Tee |
| 185 | Socket |
| 186 | Nipple 75mm Long |
| 187 | Elbow |
| 188 | Hex Nipple |
| 189 | All as per item No 106.00 here in before but for 20 mm bore. |
| 190 | Union |
| 191 | All equal Tee |
| 192 | Reducer Tee 20 x 20 x 15 mm |
| 193 | Socket |
| 194 | Reducer Socket 20 x 15 mm |
| 195 | Nipple 75mm Long |
| 196 | Reducer Elbow 20 x 15 mm |
| 197 | Elbow |
| 198 | Hex Nipple |
| 199 | All as per item No 106.00 here in before but for 25 mm bore. |
| 200 | Union |
| 201 | All equal Tee |
| 202 | Socket |
| 203 | Reducer Socket 25 x 20 mm |
| 204 | Reducer Socket 25 x 15 mm |
| 205 | Nipple 75mm Long |
| 206 | Elbow |
| 207 | Reducer tee 25mm x 25 mm x 20mm |
| 208 | Reducer tee 25mm x 25 mm x 15mm |
| 209 | Hex Nipple |
| 210 | All as per item No 106.00 here in before but for 40 mm bore. |
| 211 | Union |
| 212 | All equal Tee |
| 213 | Socket |
| 214 | Reducer Socket 40 x 25 mm |
| 215 | Nipple 75mm Long |
| 216 | Elbow |
| 217 | Reducer tee 40mm x 40mm x 25mm |
| 218 | Reducer tee 40mm x 40mm x 20mm |
| 219 | Hex Nipple |
| 220 | All as per item No 106.00 here in before but for 50 mm bore. |
| 221 | Union |
| 222 | All equal Tee |
| 223 | Socket |
| 224 | Nipple 75mm Long |
| 225 | Nipple 100mm Long |
| 226 | Nipple 150mm Long |
| 227 | Reducer 50mm x 40mm. |
| 228 | Reducer 50mm x 25mm. |
| 229 | Plug |
| 230 | Elbow |
| 231 | Reducer tee 50mm x 50 mm x 40mm |
| 232 | Reducer tee 50mm x 50 mm x 25mm |
| 233 | Hex Nipple |
| 234 | Supply and fix in replacement of unserviceable Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:- |
| 235 | 15mm dia bore |
| 236 | 20mm dia bore |
| 237 | 25mm dia bore |
| 238 | 40mm dia bore |
| 239 | 50mm dia bore |
| 240 | M&L for Arresting leakages of sluice valves by replacing Gland packing, gland bush, gland flange, nutbolts, gasket, packing material as required after dismantling in existing position including testing on completion complete all as specified and directed for the following sizes:-Note: Quoted rate is deemed to be inclusive of the materials mentioned above like Gland packing, gland bush, gland flange, nutbolts, gasket, packing material etc as required to arrest the leakages |
| 241 | 80 mm Dia |
| 242 | 100 mm Dia |
| 243 | 150 mm Dia |
| 244 | 200 mm Dia |
| 245 | S&F CI specials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single \"Y\" branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed. |
| 246 | All as per item No 113.00 here in before but for 200 mm bore . |
| 247 | Burning out lead joint in position for following sizes of CI/ DI pipe, removing old lead complete all as specified and directed :- |
| 248 | 80 mm Dia |
| 249 | 100 mm Dia |
| 250 | 150 mm Dia |
| 251 | 200 mm Dia |
| 252 | M&L for run lead joint for CI pipe/ DI pipe including spun yarn etc for spigot and socket pipes and fittings complete all as specified and directed for the following bore of pipes:- |
| 253 | 80 mm Dia |
| 254 | 100 mm Dia |
| 255 | 150 mm Dia |
| 256 | 200 mm Dia |
| 257 | S&F in repairs CAST IRON OR DUCTILE IRON MECHANICAL COUPLING / MECHANICAL JOINT / D JOINT heavy duty INCLUDING ALL JOINTING MATERIAL, ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/ CI/ DI/ GI / PVC pipes of following sizes AS REQUIRED FOR REPAIRING OF ANY KIND OF LEAKAGES COMPLETE all as specified and as directed:- Notes:- (a) Excavation and Earth work shall be measured and paid separately.(b) Quoted rate is deemed to be inclusive of cutting of any kind of pipes and all ITEMS as required for fixing and proper functioning of Joints.(c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account. |
| 258 | 80 mm Dia |
| 259 | 100 mm Dia |
| 260 | 150 mm Dia |
| 261 | 200 mm Dia |
| 262 | Supply and fixing in replacement of DI D/ F Gate valve (Soft Sealed) Resilient Seated Soft Sealing gate valves(Sluice valves RAISING TYPE) with body bonnet of ductile cast iron of grade GGG-40/ SG- 400/ 15 or GGG-50/ SG-500/ 7 or equivalent grade as per IS 3896 - Part 2- 1985 and subsequent revisions, Wedge fully rubber lined with EPDM Food grade quality and Seals of NBR and the valve should be vacuum tight and 100 % leak proof with face to face dimension as per BS 5163-89/ IS 14846-2000/ DIN 3202 F 4.and Valves should be electrostatic powder coating both inside and outside pocket less body passage class PN 1.6 including all jointing materials (Gasket, Nutbolts etc) connecting and testing complete all as specified and directed.Note : OLD SERVICEABLE VALVES TO BE DEPOSITED TO the DEPARTMENT store FOR FURTHER USE as directed by Engineer-In-Charge |
| 263 | 100 mm Dia |
| 264 | 150 mm Dia |
| 265 | 200 mm Dia |
| 266 | Cutting the existing road straight by manual, depth and width not less than 30 cm for pipes up to 100 mm dia and 60 cm for pipes from 150 mm to 150 mm dia and 75 cm for pipes above 250 mm dia and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed. |
| 267 | M&L for Construction of new PCC solid Masonry valve chamber of size 1500 X 1500 X 1500 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets around over 100 mm thick hard core, 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally and 159 mm below GL externally & top of floor including excavation earth work in hard/ Dense soil 5 mm thick MS sheet cover fixed on 59 mm X 59 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed. |
| 268 | M&L for replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including welding, bending cold or hot, drilling holes for hinged, in any shape or size as indicated for valve chamber top cover, 4 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with locking arrangement, mild steel handle, and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed. |
| 269 | Supply and lay Pipes MS black ERW Steel including specials having nominal dia 100 mm of thickness 6.0 mm as per IS 3589 - 2001, Grade - 330 with plain ends and specials by welding, leak testing of line laid in trenches / floors/ walls / ducts complete all as specified and directed.Note: Quoted rate is deemed to be inclusive of supply and fixing of flange of suitable size as required, bends welding and cutting etc as required for fixing of pipe . |
| 270 | All as per item No 122.00 here in before but for 150 mm dia |
| 271 | All as per item No 122.00 here in before but for 200 mm dia |
| 272 | Material and labour for flushing and de-silt/ de-sand cleaning of existing borewells of any diameter/ size up to 250 m depth, using a truck-mounted drilling air compressor of adequate capacity.The work includes borewell surging for dislodging compacted silt/ sand layers, followed by compressed-air flushing at a minimum pressure of 7 kg/ sq.cm to expel sand, silt, mud, slurry, organic obstructions, and fibrous blockages including tree roots, until uninterrupted discharge of clear, fresh water is obtained.The work also includes assistance during sampling, test report submission, borewell flow restoration check, and overall performance verification.Complete all as specified and directed.Note : The quoted rate shall be deemed to include mobilization/ operation of truck-mounted compressor, surging, high-pressure air flushing, removal of all extracted debris, transportation, labour, consumables and all ancillary works required to make the borewell clean, free-flowing, and test-verified. |
| 273 | Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity 3 HP to 10 HP and taking out the pump set along with pipes and fittings for flushing the bore well up to 450 feet depth or repair the pump set and strip opening the pump set for repairs/ replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed.Note :- The spares required for repair the pump sets and rewinding of motors will be measured and paid separately. |
| 274 | Disconnecting and removal of water and electrical connections from the existing submersible pump set of 3 HP to 10 HP capacity, including safe withdrawal of the pump set along with rising pipes, power cable, and associated fittings for flushing/ cleaning of the bore well up to 900 feet working depth, or for carrying out necessary repairs.The work includes complete strip opening and detailed inspection of the pump and motor assembly, replacement of worn-out or defective components, refitting of serviceable spares, reassembly of the pump set with full restoration, bench/ workshop testing for insulation integrity, current draw and discharge performance, followed by lowering and reinstallation of the pump set inside the bore well, repositioning of rising mains and fittings, reconnection of water and electrical supply at site, and commissioning of the pump set under full load to ensure smooth, efficient and satisfactory operation at rated capacity — complete in all respects, as specified and as directed.Note: All spares required for repair works and motor rewinding shall be measured and paid separately under relevant items.The quoted rate under this item is inclusive of dismantling, lifting/ lowering arrangements, tools, manpower, and all incidental works required for safe withdrawal, reinstallation, testing and commissioning of the pump set. |
| 275 | Material and labour for rewinding of submersible pump motor, including removal and taking down of the existing unserviceable copper winding complete, thorough cleaning of stator/ rotor slots, and rewinding using high-conductivity super-enamelled copper conductor with PVC insulated wire and ‘F’-Class heavy-grade insulation, maintaining winding weight and number of turns equivalent to the existing configuration to restore and achieve full rated efficiency of the motor.The scope includes precise coil winding, tight binding/ tying and securing of windings, correct interconnection of coils, and termination/ lead connections exactly matching the existing connection scheme, followed by application of suitable insulating varnish, controlled heating, and proper baking/ curing of the windings at an workshop to ensure complete moisture removal, insulation integrity, and dielectric strength.The work further includes reassembly of the motor, transport to and from the workshop, and refixing at the original installation site, reconnection of all electrical leads and coupling assemblies, followed by testing and commissioning under full load for verification of current draw, RPM stability, temperature rise, insulation resistance, and overall performance, ensuring smooth, efficient, leak-free and satisfactory operation, complete in all respects, as specified and as directed, for the capacity mentioned below.Note: Quoted rates are inclusive of all rewinding materials, workshop processes, labour, transportation, tools, and all incidental arrangements necessary for complete functional restoration and safe re-installation, and any additional spares or motor repair requirements, if applicable, shall be measured and paid separately under relevant items. |
| 276 | Submersible Motor up to and including 5 HP. |
| 277 | Submersible Motor above 5 HP up to 10 HP. |
| 278 | Supply only the following spares suitable for existing make of submersible/ centrifugal pump set 3 to 10 HP capacity, multi stage for repairs complete all as specified and directed :- |
| 279 | Gun metal Impeller. |
| 280 | Stage casing. |
| 281 | SS Sleeves. |
| 282 | Middle bush.(LB) |
| 283 | Middle sleeve. |
| 284 | Discharge outlet.(LB) |
| 285 | Pump coupling. |
| 286 | DOL SS Sleeve. |
| 287 | Suction bush. |
| 288 | Pump Shaft |
| 289 | Thrust bearing |
| 290 | Motor housing cover |
| 291 | Motor housing brushes |
| 292 | Motor adaptor |
| 293 | Motor bottom base |
| 294 | Motor T Bolt set |
| 295 | Replacement of defective pump |
| 296 | Supply and installation pump starter electric control panel board, for outdoor use, DOUBLE door dust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 200 Amps for 3 phase, 415 Volts, 50 C/ S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enamelled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 45 cm from the ground level including disconnecting/ taking out old existing unserviceable pump panel complete all as specified and directed of the following |
| 297 | INCOMMING :-(a) MCCB, 4 pole, 415 Volt, 40 Amps, 25 KA - 01 No (b) 3 Phase LED Voltmeter, class - 0.5 - 01 No (c) 3 Phase LED Ammeter, class -0.5 - 01 No (d) LED Indicator lamp in three colour RYB - 01 SetOUTGOING :-(a) MCCB, 3 pole, 10 KA \"C\" Curve 415 volts, 25 Amps -02 No (b) DOL starter in sheet enclosure type MK-1, motor rating AC - 3 duty, 415 volts, 50 HZ suitable for 7.5 HP relay max range 15-25 Amps -2 Nos(c) Single phase preventer relay type 415 volts-02 nos(d) Connector 4 way 32 amps - 2 nos |
| 298 | Material labour for removing submersible pump motor set of capacity up to 10 HP stuck in side the borewell of depth up to 200 meter by flushing the existing borewells of any size with drilling Compress remounted on truck at a pressure of 7 Kg/ Sqcm with compressed air and flushing the sand, mud including flushing out tree roots etc from the bore well till removing of the stuck motor and then clear the bore by using rod drilling using bore well drilling machine from any kind of obstruction, reinstall the motor and column pipe, necessary electric connection and testing complete all as directed and specified.Note; Quoted rate is deemed to be inclusive of flushing by using suitable compressor, rod drilling for cleaning of bore well, removing the submersible pump set stuck inside the bore well and reinstall the same after repair including removing and refixing of column pipe, casing pipe, electrical connections, testing etc as required. |
| 299 | Supply only Bleaching powder Grade-I, IS 1065:1989(used in drinking water), stable dry free flowing white in appearance without hard lumps and visible impurities in laminated high density polythene bags of 25 Kgs capacity of each bags. Notes (i) Contractor shall supply material as per monthly requirement basis in bags/containers as and when directed by Engr-in-Charge at various installation of AGE E/M No-II.(ii) The quoted rate is deemed to be included complete labour and transportation for the materials at various installations of AGE E/M No II with out any extra cost. |
| 300 | Servicing and periodical inspection of starter control panel boards suitable for 3 HP to 10 HP motor capacities.The work includes de-energizing, opening of enclosure, internal cleaning by blower/ vacuum, inspection of power and control circuits, checking and tightening of terminals, detection and rectification of loose contacts, thermal stress/ heat mark inspection, phase identification, fault tracing, minor troubleshooting, and replacement of unserviceable parts within the starter panel assembly as required for safe operational condition.The job also includes verification of starter operation, relay setting inspection, continuity and insulation condition check of control wiring, and reporting/ recording of identified defects or faults.Complete all as specified and directed.Note: All spare parts proposed for replacement shall be measured and paid under the relevant BOQ/ DCS items.Only panel servicing, inspection, fault identification, terminal tightening, and minor operational testing are covered under this item.No spare parts are included in this rate. |
| 301 | M&L for servicing of submersible pump and motor set up to 10 HP, including retrieval/ refixing (if required), dismantling, cleaning, component inspection, minor adjustments, relay/ load settings check, reassembly, restoration of electrical and delivery connections, functional testing, commissioning Complete all as specified and directed. |
| 302 | Attending Breakdown of any capacity any type (Submersible, Monoblock, Centrifugal etc) of PUMP SETS, Starter panel by Technician and Helper for checking all parts and rectify the faults and give reports to concern JE as directed by Engineer-In-Charge.Note : All spare parts to be replaced and paid against respective items. |
| 303 | Arresting leakages from pump sets of motor capacity 5 HP to 25 HP by replacing worn-out gaskets, nuts, bolts, washers, gland packing, mechanical seals (if required), and other associated sealing components.The work includes opening of pump housing/ gland area, removal of defective parts, cleaning of mating surfaces, replacement of sealing materials, tightening and adjustment of glands, reassembly, testing under operational pressure, and ensuring leak-free performance.Complete all as directed.Note: The quoted rate shall be deemed to include all materials and accessories required for arresting leakage such as gaskets, gland packing, nuts, bolts, washers, minor seals, consumables, labour and testing necessary to make the pump leakage-free. |
| 304 | M&L for Painting of centrifugal pump set of capacity up to 25 HP complete in all respect including item inlet and outlets pipes, valves, base frame complete with synthetic enamelled spray painting complete all as directed |
| 305 | M&L for Painting of water distribution header including all control and all exposed pipe of any size complete with synthetic enamelled spray painting complete all as directed |
| 306 | Supply in consumption Stequa 411 AE Refill: Chlorine tablets contained in plastic cylindrical sealed disposable sanitizer refill for disinfection of drinking water, suitable for operation through recommended dosing system.(i) Replacement indication: visual & weight variation (ii) Water contact orifice design: sealed when dry, exposed upon immersion (iii) Operation type: Non contact, non inhalator (iv) Cylinder dia: 2.5 inches + 0.5 inches (v) Cylinder height : Minimum 10.0 inches + 0.5 inches (vi) Operational stipulations: (a) Heavy metal (Pb & Hg) contamination in the product media must be BDL as per AAS data (b) Minimum volume of water disinfected by each STEQUA 411 AE Refill to obtain disinfection activity of 1 ppm on spot (Influent water quality variation, ambient & site condition variations apply) as per absorbance data generated at λmax 515 nm.Three Hundred Fifty Thousand litres.(c) Stability : Active ingredient stability (when stored at 25-45 degree Centigrade temp) must be at least 98% after one year as per data generated by accelerated Stability test protocol.(d) Safety & health hazard aspects on usage of the product media for regular drinking water disinfection: Heavy Metal contaminants (like Mercury & lead) in product media must be below detectable limit (BDL), and the product must pass the Acute Toxicity test (to specially confirm non toxicity for mammalian cells), based on which the product must be considered sate to use form human health safety point of view and freedom from toxicity when used in drinking water disinfection in recommended dosage.(e) The refills must ensure infrastructural safety (as per date generated by Electrolytic Conductivity (µs/ cm) test protocol) and operators health safety (f) STEQUA Auto Economy Refill 41 AE must be complaint with operators health safety considering regular exposure.The brand and make of the sanitizer must be staed and certified by a laboratory / study centre of any state University. |
| 307 | Supply and fix in replacement Non‑Return Valve (NRV) of size 100 mm, including necessary provisions in the existing pipeline of Cast Iron (CI) pipe / Ductile Iron (DI) pipe / MS (Mild Steel) pipe.Work includes cutting/ opening the pipeline where required, removal of old/ damaged valve, jointing/ installation of new flanged NRV 100 mm, providing suitable flange connections, nuts-bolts, rubber gasket, alignment and fixing.The job is to be executed complete in all respects, including testing and commissioning of valve operation, all as directed by the Engineer-in-Charge. |
| 308 | Supply & fix in replacement of 100 mm D/F swing-type cast iron foot valve with flanged ends, conforming to IS 4038, including rubber gasket, HT nuts/ bolts/ washers, flange cantering, removal of existing defective foot valve, installation, priming support, hydro/ line-pressure leak-tight testing, commissioning and functional check for non-return operation.Complete all as specified and directed. |
| 309 | Cutting anxious green growth / vegetation growth around pump house / transformer yard & E/M installations at ground level by cutting out roots, unwanted plants and bushes and removal of the same by surface excavation not exceeding 30 cm deep average 15 cm complete all as specified and directed. |
| 310 | Supply and fixing in replacement of Direct-On-Line (DOL) starter, suitable for motor capacity up to 5 HP / 3.7 kW, with adjustable overload protection relay in the range of 20–32 A.The work includes removal of the unserviceable starter, mounting and fixing of the new DOL starter, termination of incoming and outgoing power connections, control wiring, relay current setting/ tuning to match motor load, overload trip verification, and complete operational testing for safe and reliable start/ stop functions.Complete all as specified and directed.Makes : L&T / Havells/ CG as approved. |
| 311 | Supply and fixing in replacement of single-phase preventer (phase-failure / dry-run / voltage imbalance protection unit), suitable for motor capacity up to 7.5 HP, for repair works.The scope includes removal of the unserviceable unit, mounting/ fixing of the new single-phase preventer, termination of power and control connections, configuration/ setting as required for motor protection parameters, and complete functional testing including phase-failure protection, auto-cut-off verification, and safe operational trial of the motor.Complete all as specified and directed.Make : L&T cat part No CS94824DOOO or equivalent of Havell/ MINILAC |
| 312 | Supply and fixing (S&F), in replacement of defective cable, PVC insulated, copper conductor, flexible flat submersible cable of size 4 sq.mm, 3 core, 1100 Volts grade, specifically suitable for submersible pump installations, including cables equivalent to specifications defined under relevant standards conforming to IS 694:1990 with the latest amendments, using compatible pump-duty submersible flat cable design for 3 HP to 10 HP class pump systems.The work includes safe disconnection and complete removal of the existing unserviceable flat cable, drawing out cable from bore well route or through rising pipe, cutting the new cable to the required length for site termination, providing and crimping appropriate end ferrules/ lugs using fittings similar to those from trusted industrial terminal parts, installing waterproof cable joints using approved submersible-grade jointing kits comparable to those from manufacturers such as 3M India Limited or equivalent, proper tightening, insulation and dressing of cable terminations, ensuring mechanical safety and electrical integrity, followed by continuity test, insulation resistance test, full functional testing, and commissioning of the pump system to verify satisfactory cable performance under rated load complete in all respects, as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |