| 1 | Taking down defectivestreet light fitting of any size/ type/capacity from height of pole/walls/builiding of any location exceeding 3.0 m height for repair work and re-fixing back after repair work including checking, inspecting and testingcommmissioning, complete all as specified and directed.Note:(a) The defective forItems like electronicdrivers, surge protection devices etcshall be measured and paid separately under relevant items here in under this Schedule. (b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. (c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.(d) The cost forrepairs toLED panel is not included in the scope and shall be measured and paid separately. |
| 2 | Supply only the following spares suitable for LED street/Flood light fittings, complete all as specified and directed:- |
| 3 | Electronic driver suitable for outdoor LED fitting of capacity 120 to 180 Watt. |
| 4 | Electronic driver suitable for outdoor LED fitting of capacity 70 to 110 Watt. |
| 5 | Electronic driver suitable for outdoor LED fitting of capacity 30 to 60 Watt. |
| 6 | Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with lumen output not less than 110 lumens/Watt) min wattage 30 watt,with ingress protection IP 65/66 and SPD of capacity 5 KV etc including copper conductor cable, PVC insulated, sheathed flexible, multistranded ISI marked 1100 volts grade 3 core 1.5 sqmm up to 1.5 M and including necessary clamps/nut bolt etc complete and testing on completion, complete all as specified and as directed.Note: The GI pipe bracket if requiredwill be measured and paid separately under relevant schedule items. |
| 7 | All as per Serial item No. 3.00 here-in-before but for Supply & fixing LED security light fittings 45 watt. |
| 8 | All as per Serial item No. 3.00 here-in-before above but for Supply & fixing LED security light fittings 60 watt. |
| 9 | All as per Serial item No. 3.00 here-in-before but for Supply & fixing LED security light fittings 70 watt. |
| 10 | All as per Serial item No. 3.00 here-in-before but for Supply & fixing LED security light fittings 90 watt. |
| 11 | Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with lumen output not less than 110 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc completeand testing on completion, complete all as specified and directed. |
| 12 | All as per Serial item No. 8.00 here-in-before but for Supply & fixing LED flood light fittings 200 watt. |
| 13 | Supply & fix in replacement decorative path way light lighting LED decorative post top lantern for 360 degree not less then 40watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired, complete all as specified and direrected. |
| 14 | Supply & fix in replacement of Post Top LED not less then 20 watt with opal acrylic globe type with IP65 Protection made up of polycarbonate,including all accessories prewired mounted on 1.5 Mtr GI pole completewith necessary PCC type C-1 (1:3:6) foundation 30x30x30cm and PCC block 15cm heightabove ground complete including taking out of old unserviceable items, complete all as specified and direrected. |
| 15 | Supply & fix in replacement ofIntegral decorative LED not less then 20 Watts Post Top lantern in victoria model with combination of aluminium ca sted and opal acrylic with IP65 Protectionmounted on GI pipe not less then 1M completewith necessary PCC type C1 (1:3:6) work if required including taking out of old unserviceable items, complete all as specified and directed. |
| 16 | S&F in replacement for decorative LED Bollard light with opal diffuers and aluminium reflector outdoor type LED Bollard light not less then 10W, IP 65 lihgt including all accessories and connecting materials such as clamps, brackets, nut bolts reducer etc with base PCC type C1 (1:3:6) fixed on wall/floor and making electrical connection with copper cable, complete all as specified and directed. |
| 17 | Supply and fix in replacement solar light luminaries with ALL-IN-ONE Smart Integrated Solar Street Light with built in mono Crystalline Panel, Lithium Ferro Phospate (LiFeP0 4 ) Battery, MPPT Charge Controller and PIR Sensor with Colour Temperature 6000-6500K and 2 days autonomy with dimming profile of output not less then 15 wattwith all standard fixing accessories for fixing/mounting on existing solar street light pole, complete all as specified and directed. Note :- Contractor shall be provide manufacturer technical data sheet and warranty certificate for not less than two years. |
| 18 | Supply & fix in replacement for copper conductor cable, PVC insulated, sheathed flexible, multistranded ISI marked 1100 volts grade 3 core 1.5 sqmm and includingPVC conduit 25 mm dia with fixing arrangement flat iron clamptwo number with the help of nuts and bolts on pole including connection and testing and after taking down old unserviceable copper conductor cable, complete all as specified and directed. |
| 19 | Supply & fix in replacement loop-in/loop-out thermo plastic (Polysterene) box having protection class IP-66 and of overall size 210mm x 155mm x 92mm FRP (Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 4 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed toto steel tubular/PCC pole using aluminium strip (25x3mm) clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glandsof cable sealing range 10mm to 17mm (Complete with check nut) lugs, including dismantling old one, complete all as specified and directed. |
| 20 | Supply and installation in replacement maintenance free battery lead acid type of capacity 12 Volt 100 AHfor Solar lightinstalled at various location of Rajouri Garrison withwarranty not less than 36 month, complete all as specified and as directed. |
| 21 | Supply & fix in replacement of street light bracket bend to shape made as required of 40mm dia not less than 1.2 mtr long GI pipe light grade fixed to pole/wall with flat iron clamp of size not less than 40x6mm two number with the help of nuts and bolts for fixing of street light fitting including making all electric connection including taking out old one, complete all as specified and directed. |
| 22 | Supply, laying, testing and commissioningofXLPE insulated armoured, heavy duty electric cable with aluminium stranded conductor of size 35 Sq mm 3.5 core, laid in trenches, fixed on wall, passing through pipes complete including connecting with MCCB/ busbar with the help of proper size thimble, glands, properly as directed by engineer-in-charge and taking out existing damaged unserviceable cable.avation, complete all as specified and directed. Note : Excavation, earthwork and cable protection shall be measured and paid separately under relevant items. |
| 23 | All as per Serial item No. 19.00 here-in-before but size 25 Sq mm, 3.5 core. |
| 24 | All as per Serial item No. 19.00 here-in-before above but size 16 Sq mm, 4.0 core. |
| 25 | All as per Serial item No .19.00 here-in-before but size 16 Sq mm, 2.0 core. |
| 26 | All as per Serial item No .19.00 here-in-before but size 10 Sq mm, 2.0 core. |
| 27 | Taking down & Re-Laying ofXLPE LTUG cable PVC insulated, beddedarmoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 to 70 Sqmm 3.5/4 Core laid in trenches or fixed on wall/floor/poles, complete all as specified and directed. |
| 28 | Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft/ loose soil, complete all as specified and directed. |
| 29 | Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm, complete all as specified and directed. |
| 30 | Removing excavated soil not exc50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed. |
| 31 | M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testingthe cable, complete all as specified and directed.Note: Only punned thickness shall be measured for payment purpose. |
| 32 | M&L for sub class ‘B’ Bricks old size, laid dry flat over the cable butting each other length of cable equal to width of brick, complete all as specified and directed. |
| 33 | Cutting existing road surface or hard standing, bituminous topping 15 cm but n exc 30cm girth for laying of pipes/ cables and making good distrubed surface to match with existing, complete all as specified and directed. |
| 34 | M&L for double wall corrugated pipe (DWC) of 75mm dia confirming to IS: 16205 Part-24 and IEC 61386 (Part-24)for cable protection of cable under/above ground surface, complete all as specified and directed. |
| 35 | Supply & fixing in replacement of galvanised steel tubing of size 50 mm dia light grade (ISI marked) for protection of under ground cable on poles/ walls under road crossing etc including dismantling and taking down existing pipe, complete all as specified and directed. |
| 36 | Supply, Laying, connecting and testing of service cable of size 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connectionsor after taking down old unserviceable cable including others accessories, complete all as specified and directed. |
| 37 | All as per Serial item No. 33.00 here-in-before but size 16Sq mm, 2core. |
| 38 | M & L for cable jointing kitLT 1100 volt under ground cable for straight through heat shrink type complete with jointing material and acessories suitable forXLPE armoured aluminium conductor cable of size between 4 core 10 sqmm to 3.5 core 35 sqmm, complete all as specified and directed. |
| 39 | Material and labour for painting of LT single pole structure consistingofbracing, cross arms, channels,clamps, supports, nuts, bolts with two coats of Silver paint over a coat of red oxide primer after preparing the existing external surfaces and marking of nomenclature of pole with black paint and including making alternate strips each of 30 cm height with black and white synthetic enamel paint upto 1.20 mtr height from top of PCC copping, complete all as specified and directed. |
| 40 | Supply and erecting in true vertical position steel tubular swaged pole, 9 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-31 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxideand two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacing including taking down of old existing broken/cracked pre stresed concrete pole 9 metres long, complete all as specified and directed.Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of Sch \"A\". |
| 41 | M&L for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregate), as in foundation filling and mass concrete for poles and stay/installation paths, complete all as specified and directed. |
| 42 | M&L for PCC 1:3:6 (nominal mix) type C1 (using 20mm graded crushed stone aggregate) as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 43 | M & L for replacement of Off Load type change over switch 4 Pole, 415 Volt, Conforms to IEC 60947-3 , IS/IEC 60947-3 having side handle manual changeover open execution of capacity 63 Amps, complete all as specified and directed. |
| 44 | S&F in replacement MCCB 63 Amps, FP, 16 KA, 415 volts, FP, 50 Hz, thermal magnetic release, lcs=100% lcu in existing panel complete all as specified and directed. |
| 45 | S&F in replacement MCCB 100 Amps, FP,16KA, 415 volts, FP, 50 Hz, thermal magnetic release, lcs=100% lcu in existing panel complete all as specified and directed. |
| 46 | M & L for Earthing complete with galvanised iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia GI medium grade with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991, complete all as specified and directed. |
| 47 | M&L for earthing complete with galvanised steel earth plate electrode 60cmx 60cm x6mm thick burried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge of the earth plate not less then 1.5 mtr deep below normal ground levelconnected to and including galvanised iron strip 25x4 mmas earthing le by means of bolts nuts check nuts and washers of steel after welding of GI tubing light grade 32mm bore protection pipe upto test point. 20 mm dia GI watering pipe medium grade with funnel and wire mesh ,PCC pit 1:3:6 with pit cover of size 40mm x 40mm x 4mm ,adquite qty of charcoal dust and salt layers all around the earth plate , removal of surplus soil and returining filling in all as required at site including test point made out of steel plate of Size 75x75x6mm fixed to wall or pole all as specified in plate No 3 of SSR Part-I, complete all as specified and directed.Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge. |
| 48 | Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1050mm width x 800mm Height (With Canopy & Base Channel)x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 NosAluminium bus bars of rating 100 amps, Provision of Spreader link toincoming side ofMCCBsfor termination of cables and 4 way ebonite cable connector (rating 32 amps) for termination of outgoing cables with MCBs.TheFeeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar andhaving modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitablerubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheetand 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facilitywith single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt,The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :- |
| 49 | (a)LOCATION : STREET LIGHT CONTROLLER (b)PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided in the bottom for both incoming and outgoing cables. (c) BUS BARS & INTERNAL CONNECTIONS :- The bus bars shall be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink typePVC sleeves andrigidly mounted on suitable size \"F\" class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material.4 NosAluminium bus bars of rating 100 amps,. For all internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm.(d) CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.(e) INCOMING :-4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA Fixed magnetic and Fixed thermal setting of rating 100 Amps. -01 NoMake : LEGRAND /SCHNEIDER / ABB(f) OUTGOINGS :-(i)MCCB 63 Amp,TPN,04 POLE having breaking capacity 16 KA -03 Nos. (Feeder No. 1,2 & 3)Make : LEGRAND /SCHNEIDER / ABB |
| 50 | (g) STREET LIGHT CONTROLLER :This shall be made of the following articles complete with all wiring harness as required :-(i) 3 Pole power contactor, suitable for 415 volts AC 50 Hz supply and current carrying capacity 40 Amps. - 01 No.Make : L&T (ML-3) / BCH / TC(ii) DIN rail mounted, Astronomical Time Switch, 1 Channel,suitable for operate in 230 volts AC 50 Hz supply and operating mechanism based on sun rise / sun set timing of a preset lattitude and longitude of a particular location - 01 No.Make : LEGRAND (Cat No. - 412654 Alpharex D21 astro) OR Equivallent model in SCHNEIDER(iii)6 Amps rated Rotary type selector Switch for Auto / Manual Selection - o1 No. Make : KAYCEE / L&T / C&S (RAAS)(h)MISCELLANEOUS ITEMS :- (i) SP MCB 6 Amps 10 KA (For Control Wiring) - 01 No. Make : LEGRAND /SCHNEIDER / ABB(ii)Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos |
| 51 | (j)Notes.(i) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar.(ii) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar.(iii) All the inner / outer doors shall have locking facility through castle locks(iv) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this.(v) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department.(vi)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm(vii)The Panel Board shall be designed in such a way that adequete workable space is made available inside every compartments.(viii) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process. |