| 1 | Taking down ceiling fan/exhaust fan /air circulating fan/wall fan of any size or of any make from any locations (OTM/Md Accn) under GE (AF) Nagpur by disconnection eletric connection, cleaning the fan box area, bringing to AGE E/M Yard and refixing at the desired location after reassembling and removing of burnt out windings (copper/aluminium), servicing/ overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/ grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material/items,making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using minor sparte/parts such as screws, insulation tape, nuts, bolts, washers, split pins etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and as directed.Note:- (i)PVC copper flexible wire 1.50 Sqmm three core, nut bolts, washers, screws, capacitor clamp, warnishing included in the quoted rate.(ii)Other connected items required like re-winding, painting, capacitors, Bearings, Bush, Canopy,down rods etc will be measured and paid sperately under respective items.(iii)Total service time from taking down to rehanging must not exceed 03 Days .(iv) Cost ofT&P & transportation including taking down and re-fixingare included in the quoted rate |
| 2 | Material and labour for re-winding of ceiling fan 1200mm/1400mm sweep which of copper windingwith proper grade/guage super enamelled copper winding wire so as to achieve original specifications i.e current rating and RPM (RPM test of ceiling fan with suitable tachometer will be done by contractor and shown to deptt , tachometer will be provided by contractor at their own expense) and all insulating materials (spares will be used and measure in respective items) and reasembling etc complete all as specified and directed. |
| 3 | Notes for Sr Noitem No 1 & 2:- (i) The fans should be re-winded as per existingguage copper winding .Schedule of credit shall be deducted as per the burnt out winding.(ii) Winding wire shall be cut in front of Engr-in-Charge before winding of fans.(iii) In case winding or any accessory i.e capacitor, regulator becomes non functional during defect liability period, it will be repaired without any extra payment within 05 days of complaints received. |
| 4 | All as per item No 2 above but for exhaust fansany typeof size 150 mm sweep to 380 mm sweep. |
| 5 | All as per item No 2 above but for exhaust fan any type of size 450 mm sweep |
| 6 | All as per item No 2 above but for wall fan of any size |
| 7 | Material and labour for replacement of defective ball bearing for ceiling fans/exhaust fans/Air-circulators/Wall fanof any size and of any make complete all as directed. Make: NBC/TATA/SKF |
| 8 | Material and labour for replacement of defective Shaftfor ceiling fans/exhaust fans/Air-circulators/wall fanof any size and of any make complete all as directed. |
| 9 | Material and labour for replacement of defective gear boxfor wall fanof any size and of any make complete all as directed. |
| 10 | Material and labour for replacement of defective swing motorfor wall fanof any size and of any make complete all as directed. |
| 11 | Material and labour for replacement of defective capacitor of size 2.5 mfd ISI marked for any type of fans suitable for 250V/230V including making connection complete all as specified and directed.Make : Havells/Legrand/Epcos/ Siemens |
| 12 | Material and labour for replacement of gun metal bush suitable for any type/model/size of fans complete all as specified and directed. |
| 13 | Supply and fixing0-4 step, two module,modular type electronic regulator for ceiling fan 1200 mm sweep, 240 volts, 100 Watts humfree single pole, all as specified and as directed.Make : Legrand Cat No. 675532 or equivalent in L & T/ Havells |
| 14 | Material and labour for spray painting of ceiling fans/exhaust fans/air circulators of any size, any type and any make motor, body, blade and frame with one coat of synthetic enamelpaint by spray painting to achieve smooth and uniform finish incl removal of existing paint, filling up cavities with filler and writing of MES No with black paint complete all as specified and directed.Note :- Painting of fans must be done before delivery of fan by contractor to Deptt on the same day. |
| 15 | Supply only down rod 30 cm long, 15mm bore made out of Galvanised iron, with complete provision for hanging ceiling fan including cutting of pipe at both ends and making suitable holes forinserting fixing bolts split pins/cotter pins including suitable check nuts and necessary clamps socket with insulating rubber bush and all as specified and as directed. |
| 16 | Supply only down rod 60 cm long, 15mm bore made out of galvanised iron, with complete provision for hanging ceiling fan including cutting of pipe at both ends and making suitable holes forinserting fixing bolts split pins/cotter pins including suitable check nuts and necessary clamps socket with insulating rubber bush and all as specified and as directed |
| 17 | Supply and fix in repair GI nut bolt suitable for hanging clamp with split pins as per sample etc complete as specified and directed |
| 18 | Supply and fixing in repair of heavy duty hanging clamp suitable for 1200/1400 mm sweep complete as specified and directed |
| 19 | Supply and fixing in repair PVC conopy including screws washer etc complete as specified and directed |
| 20 | Supply and fixingin repair fan blade made of aluminium suitable for 1200/1400mm sweep ceiling fans(Set of 03 Nos) including framecomplete as specified and directed |
| 21 | Supply and fixingin repair fan blade made of PVC/aluminium as required at site suitable for 150 to 380mm sweep exhaust fans including framecomplete as specified and directed |
| 22 | Supply and fixingin repair fan blade made of aluminium as required at site suitable upto450mm mm sweep exhaust fans including frame complete as specified and directed |
| 23 | Supply and fixingin repair BLDC control Electronic Control Unit (ECU) or Printed Circuit Board (PCB) for ceiling fan, regulator controlled, operating voltage range from 120V to 270V, 50 Hzssuitable for 1200/1400 mm sweep BLDC ceiling fans as required at site complete as specified and directed |
| 24 | Supply and fixingin repair BLDC fan motor including necessary kit for BLDC ceiling fan, regulator controlled, operating voltage range from 120V to 270V, 50 Hzssuitable for 1200/1400 mm sweep BLDC ceiling fans as required at site complete as specified and directed |
| 25 | Supply and fixingin repair wall Fan blade made of PVC as required at site suitable upto450mmsweepcomplete as specified and directed |
| 26 | Supply and fixingin repair wall Fan cover (02 Nos, Front & rear)made of aluminium as required at site suitable upto450mmsweepcomplete as specified and directed |
| 27 | Supply and fixingin repair motor for exhaust fan PVC bodysuitable for 150mm to 380 mm sweep exhaust fans complete as specified and directed. |
| 28 | Supply and fixingin repair motor for exhaust fan metal bodysuitable upto 150 to 450mm sweep exhaust fans complete as specified and directed |
| 29 | Supply and fixingin repair PVC bodyfor exhaust fan suitable upto 150 to 380mm sweep exhaust fans complete as specified and directed |
| 30 | Material and labour for replacement of defective capacitor of size 4 mfd ISI marked for any type of fans suitable for 250V/230V including making connection complete all as specified and directed.Make : Havells/Legrand/Epcos/ Siemens |
| 31 | Supply and fixingin repairs stationary louvers suitable for exhaust fan of 150 mm to 450 mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed.Note: (i) Louver has to fixed upto 20 mtr height multistoried building. (ii) The unit quoted rate shall deemed to be inclusive of necessary scafolding and safety measure for fixing of louver upto sixty metre height. No extra claim on this account shall be entertained. |
| 32 | Supply and fixingin replacement heating element 2 KW(Traingular/Round type) made of copper, ISI marked, 230 Volts suitable for 25/50 Ltr capacityof Geysers as per site requirement , brass metal, CP complete all as directed. Make : Usha/ Racold/ Bajaj |
| 33 | Supply and fixing in replacementheating element 2 KW (Assembly type) made of copper, ISI marked,230 Volts suitable for 25 Ltr capacityof Geysers as per site requirement complete all as directedMake : Usha/ Racold/ Bajaj |
| 34 | Supply and fixing in replacement Thermostat made of copper, ISI marked,suitable for 25 Ltrs capacityof Geyser as per site requirement complete all as directed. Make : Usha/ Racold/ Bajaj |
| 35 | Supply and fixingflexible connection pipe with steel wire braided hose 46 cm (18 inch) long as outlet for hot water and to withstand pressure upto 1.2 MPa of 15 mm dia size with PTMT nuts including taking down the old unserviceable PVC pipe, ISI Marked, complete all as specified and directed. |
| 36 | Supply and fixing\"D\" clamp after cutting the ceiling of roof and binding with reinforcement and making good with cement reinforcement and finishing with matching with existing surfaces, including anchor bolt having four nuts and washers for hanging of ceiling fans complete all as specified and as directed. |
| 37 | Material and labour for making holes in surface wall for exhaust fan for 150/250 mm sweep size all including plastering and making good the disturbed surface and Supply & Fixing New Exhaust fan PVC body 150/250 mm sweep 230 V, 50 Hz, complete with all accessories & connector etc internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, all as specified. |
| 38 | Material and labour for making holes in surface wall for exhaust fan upto 300 mm sweep size all including plastering and making good the disturbed surface and Supply & Fixing New Exhaust fan PVC body 300 mm sweep 230 V, 50 Hz, complete with all accessories & connector etc internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, all as specified. |
| 39 | Taking down exhaust fan for cleaning of heavy oil fumes deposited in exhaust fan both metal body or PVC body of size 150 mm to 450 mm with suitable chemical and refixing it back with suitable required nut, bolt etc.NOTE: Rates are deemed to be included of nut, bolt, chemical, disconnection and reconnection. Cleaning of exhaust fan will be done at AGE E/M store yard in front of detailed MES representive. |