| 1 | M & L for Desludging/Dewatering of septic tanck/ soakage wells including inlet/outlet chambers removing out all scum, silt residuals sludge (Both organic or inorganic nature) after plugging the incoming sewage lines through combined high pressure water jetting cum suction (vaccum) type machine mounted on LCV/HCVfacility of high presure vaccum and removing the same in the tankto a place outside cantonment meant for the purpose by local municipality all complete all as specified and directed. |
| 2 | M&L for cleaning of man holes n.exc 1.5m deep and removingsludge/waste material etc to a distance n. exc 150m and burrying in pits and re-filling the same complete all as specified and directed by the Eng-in-Charge. Note:-The cost for excavation and earth work for pits is deemed to be included in the unit rate complete all as specified and directed. |
| 3 | All as per item No.2 above but exc 1.50m deep andn. exc 3.0m deep complete all as specified and directed. |
| 4 | M&L for cleaning of drain pipesof any dia /boreby rodding from manhole to manhole or manhole to septic tank or vice versa and well flushing with water after cleaningand removingwaste material etc to a distance n. exc 50m and burrying in pits and re-filling the same complete all as specified and directed.. Note:-The cost for excavation and earth work for pits and taking off manhole cover and placing the same in position after cleaning, is deemed to be included in the unit rate. |
| 5 | M&L for cleaning of soil waste pipes (cast iron/PVC/SGSW/DWCP ) any bore by rodding with jute bags and wellflushing after cleaning complete all as specified and directed. |
| 6 | M&L for cleaningof gully traps of any size including any pipe upto first manhole and removingwaste material etc. to a distance n. exc 50m and burrying in pits and re-filling the same complete all as specified and directed.. Note:-The cost for excavation and earth work for pits is deemed to be included in the unit rate. |
| 7 | M&L for cleaningof floor traps and removing waste material etc to a distance n. exc 50m and burrying in pits and re-filling the same complete all as specified and directed by the Eng-in-Charge. Note:-The cost for excavation and earth work for pits is deemed to be included in the unit rate. |
| 8 | M&L for cleaningof\"P\" traps in WC and removing waste material etc to a distance n. exc 50m and burrying in pits and re-filling the same complete all as specified and directed by the Eng-in-Charge. Note:-The cost for excavation and earth work for pits is deemed to be included in the unit rate. |
| 9 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 10 | S&F Mild steel framed work such as door or gates of angle or other section with gusset plates, rails braces etc.,with ornamental and intricate design complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging , also fastening and fixing including shop coat of zinc chromate paint conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed. |
| 11 | Demolition and bracking up drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar internal dia of pipe 200 mm complete all as specified and directed. |
| 12 | All as per item No.11 above but 150mm dia complete all as specified and directed. |
| 13 | All as per item No .11 above but 100mm dia complete all as specified and directed. |
| 14 | M&L for concrete bed to drain pipes of bore 200mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports complete all as specified and directed.. Note:-(i) Thickness of bed belew barrel ofpipe -10 cm (ii) Width of bed :- outer diaof pipe plus 30 cm. |
| 15 | All as per item No. 14 above but 150mm dia drain pipes complete all as specified and directed. |
| 16 | All as per item No.14 above but 100mm dia drain pipes complete all as specified and directed. |
| 17 | M&L for 200mm bore dia reinforced cement concrete pipes, class NP-2, laid and jointed complete with collars, complete all as specified and directed. |
| 18 | All as perabove item No 17 above but 150mm bore complete all as specified and directed. |
| 19 | M & L for 200mm Bore / inner dia double wall, corrugated HDPE Pipe (SNB) (ISI Marked) with integral socket & necessary fitting jointing as directed & laid in trenches complete all as specified and directed |
| 20 | All as per aboveitem No 19 above but 150mm bore complete all as specified and directed. |
| 21 | All as per item No 19 above but 100mm bore complete all as specified and directed. |
| 22 | Dismantling cast iron, AC, reinforced concrete andPVC pipe of any description or dia fixed with wall or taking out from trenches complete all as specified and directed. |
| 23 | M&L 100mm bore cast iron soil,waste and vent pipes in any length with or without ears, with cement joints fixed to wall complete all as specified and directed. |
| 24 | All as per item No.23 above but 75mm bore complete all as specified and directed. |
| 25 | S&F in repairs 100 mm bore CI Bend (any radius) diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed. |
| 26 | S&F in repairs 75 mm bore CI Bend (any radius) diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed. |
| 27 | S&F 110 mm bore PVC(SWR) pipes single socketed, in any length with rubber ring joints , laid in trenches or in floor complete all as specified and directed. |
| 28 | All as pr item No27above but 75 mm bore pipecomplete all as specified and directed. |
| 29 | S&F 110 mm bore PVC(SWR) pipes single socketed, in any length with rubber ring joints , fixed to wall complete all as specified and directed. |
| 30 | All as pr item No29above but 75 mm bore pipecomplete all as specified and directed. |
| 31 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 32 | All as per item No 31above but 75 mmcomplete all as specified and directed. |
| 33 | S&F Stack clamps made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or rooffor 110 mm bore complete all as specified and directed. |
| 34 | S&F Stack clamps made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or rooffor 75 mm bore complete all as specified and directed. |
| 35 | M & L for Loose filling with broken bricks of gauge 80 to 150mm in soakage pits, soakage wells,complete all as specified and directed. |
| 36 | Demolition of cement concrete (reinforced) Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete all as specified and directed. |
| 37 | M&L for reinforced cement concrete 1:1.5:3 type B-1 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 38 | S&F TMT bars10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 39 | S&F TMT bars6 to 8mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 40 | M&L for use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping, rough finished surface of concrete complete all as specified and directed. |
| 41 | Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls , floors and roofs not exceeding 20cm wide and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exceeding 5 cm wide but not exceeding 10cm wide, surface flat for rough finished surface of concrete complete all as specified and directed. |
| 42 | M&L for precast cement concrete 1:2:4 type B-I using 20 mm graded stone aggregate as in cover slabs, (for man holes)chullah hoods, chajjas, shelves and similar articles with plain faces and set in mortar 1:6 complete all as specified and directed. |
| 43 | Demolition of cement concrete(unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or aboveground level) complete all as specified and directed. |
| 44 | M&L for providingcement concrete 1:4:8 type D-2 using 40 mm graded stone aggregates as in foundation, filling and mass concretecomplete all as specified and directed. |
| 45 | M&L for cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregates as in cills, lintels,upto 1.50 metre clear span, copings, benching, bed plates etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works complete all as specified and directed. |
| 46 | M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternatebays (n exc 2 Sqm each )and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weightcomplete all as specified and directed. |
| 47 | M&L for 100 mm thick PCC 1:2:4 type B-2 using 40 mm graded crushed stone aggregates as in floor/ sub-base complete all as specified and directed. |
| 48 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 49 | M&L for Non-skid coloured ceramic tiles (square/rectangular) 7 to 8 mm thick, area of each tileexc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or colouredcement to match including 25mm thick PCC type B-0 1:2 (12.5mm graded agg. and 10mm thick screed bed or bedding layer of mortar for laying floor CM 1:4,complete all as specified and directed. |
| 50 | M & L for Glazed ceramic colored tiles 600mmx300mmx 6 to 7mm thick/450mm x300 mm x 7mm,as in patches invertical surfaces such as dado, skirting, wall etcset& jointed in neat cement slurry and pointed with coloured cement to match with tiles in over and including 10mm thick cement plaster in cement mortar 1:4. complete all as specified and directed. |
| 51 | M&L for excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil/strata for foundation, etc, or for shafts, wells, drain pipes and getting out complete all as specified and directed. |
| 52 | All as per item No. 51 above but depth exc 1.5m and n.exc 3.0m complete all as specified and directed. |
| 53 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 54 | Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed. |
| 55 | Demolition of brick work or stone masonry built in cement mortar including all quoines arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles complete all as specified and directed.. |
| 56 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 complete all as specified and directed.. |
| 57 | All as per item No.56 above but except bricks. complete all as specified and directed. |
| 58 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 59 | M&L for15 mm thick rendering on fair faces of brick /concrete surfacesin cement mortar 1:4 and finishedeven and smooth without using extra cement complete all as specified and directed. |
| 60 | Supply only integral water proofing compound complete all as specified and directed. |
| 61 | M & L for Preparing surfaces plastered or unplastered and applying two coats of cement base paint on walls complete all as specified and directed. |
| 62 | S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 63 | Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified and directed. |
| 64 | S & F in viterous china squatling Pan orisa pattern size 580x440mm white, with integral feat reots including connection to trapand to flush pipes etc and excluding flushing cistern and flush pipes complete all as specified and directed. (fixed in repairs). |
| 65 | S & F Vitreous china wash down closet pan (Pedestal pattern) white with ‘S’&\"P\"trap including plastic seat cover white including connection to out going pipe & to flushing pipe, anti syphonage pipeetc complete all as specified and directed by Engineer-in-charge (including making good to floor and fixing in repairs) |
| 66 | Supply only flush pipe ofPVC, 32mm dia, for low level cistern complete all as specified and directed. |
| 67 | M&L forHard core of broken stone or boulders of gauge n. exc 63 mm deposited spread and levelled in layers n exc 15 cmthick watered and rolled / rammed to a true surface complete all as specified and directed. |
| 68 | M&L for 100mm thick PCC 1:4:8 type D-2 (40 mm graded stone agg ) as in sub base, complete all as specified and directed. |
| 69 | M&L for precast coloured machine pressed / vibro mechanically floated interlocking paver block any shape and size conforming to IS - 15658-2006 of 80 mm thickness , M-40 grade ,with topping of cement mixed with imported pigment Red/Yellow Laid over and including 40mm thick sand cusion over prepared beases. Colour and shape shall be approved by Engr-in-chatge. (Make: ULTRA/MODERN/RUCHI/ISI Marked) |
| 70 | S&F On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 30 users , complete all as specified and directed. |