| Sl. No. | Item Description |
| 1 | Taking down sub main wiring alongwith damaged casing capping /PVC conduit pipe from the wall roof or in floor and making good disturbuted surfaces complee all as directed |
| 2 | S&F Sub main wiring with two single core cable PVC insulated unsheathed copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including PVC casing caping with all accessories like tee, bend,elbow of high quality material of size not less than 20mm ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed Note:- (i)Three lengths of 6 Sqmm cable and one length of PVC casing & caping will be measured as one length. |
| 3 | All as per item No. 2.00 mentioned here-in-before but for 4 Sqmmcomplete all as specified and directed. |
| 4 | S&F in repair Sub main wiring with two single core cable PVC insulated unsheathed copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through existing concealed conduit with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed Note:- (i) Three lengths of 6 Sqmm cable will be measured as one length. |
| 5 | All as per item No. 4.00 mentioned here-in-beforebut for 4 Sqmmcomplete all as specified and directed. |
| 6 | S&F factory madepowder coated distribution boardTPN,4 ways, IS 8623, IEC 61439-3, double door,protection class IP-43, fabricated from CRCA sheet and fixed / flushed onwallsuitable for universal mountingincluding 200 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc including taking down old unserviceable DB with MCB complete all as specified anddirected.Note :- (i) MCBs shall be measured and paid seperately.(ii)Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. |
| 7 | S&F factory madepowder coated distribution boardSPN,4 ways, IS 8623, IEC 61439-3, double door,protection class IP-43, fabricated from CRCA sheet and fixed / flushed onwallsuitable for universal mountingincluding 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc including taking down old unserviceable DB with MCB complete all as specified anddirected.Note :- (i) MCBs shall be measured and paid seperately.(ii)Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. |
| 8 | S&F factory madepowder coated distribution boardSPN,8 ways, IS 8623, IEC 61439-3, double door,protection class IP-43, fabricated from CRCA sheet and fixed / flushed onwallsuitable for universal mountingincluding 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc including taking down old unserviceable DB with MCB complete all as specified anddirected.Note :- (i) MCBs shall be measured and paid seperately.(ii)Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. |
| 9 | S&F factory madepowder coated distribution boardSPN,12 ways, IS 8623, IEC 61439-3, double door,protection class IP-43, fabricated from CRCA sheet and fixed / flushed onwallsuitable for universal mountingincluding 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc including taking down old unserviceable DB with MCB complete all as specified anddirected.Note :- (i) MCBs shall be measured and paid seperately.(ii)Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. |
| 10 | S&F MCB TPN, 63 Amps415 Volts , type \"C\" curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB. |
| 11 | S & FSPN MCB 25 TO 32 amp rating 240V, 10KA \"C\" curveIS-8828 marked fixing in the MCB DB complete with connection & testing all as specified & directed.Note :-Make of MCB shall be same of that DB. |
| 12 | S & F MCB SP, 6 to 32 Amps240 Volts , \"C\" curve, 10 KA, IS-8828 marked for fixing in DB complete all as specified & directed.Note :-Make of MCB shall be same of that DB |
| 13 | S&F MCB DP 40 to 63 amps C Curve 240 volts 10KA breaking capacity complete all as specified. |
| 14 | Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4.0mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 20 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 15 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed. |
| 15 | Supply& fix in repairs 1.5 Sqmm FRLSH Copper conductor coil in existing concealed conduit /PVC casing caping complete all as specified and directed. |
| 16 | Supply & fix in repairs 2.5 Sqmm FRLSH Copper conductor in existing concealed conduit/PVC casing caping all as specified and directed. |
| 17 | Supply and fix casing caping in replacement with accessories like tee, bend,elbow of high quality material size 12-20mm of 2m length complete all as specified and directed. |
| 18 | Supply and fix in replacement PVC flexible 2 core cable with copper con-ductor ofany sizefrom ceiling rose to ceiling fan complete all as specified and directed. |
| 19 | Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses , regulators and fittings complete and making good the disturbed surfaces all as directed by Engineer-in-Charge. |
| 20 | Material and Labour forPoint wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core, unsheathed, copper conductor cable drawn through and including PVC conduits Concealed in walls, ceiling etc with all fittings and accessories of PVC conduits (like Tee, bend etc.) complete fixed to walls/ceiling etc. with and including 1.5 Sqmm (nominal area) FRLSH PVC insulated, unsheathed, multistranded, single core, copper cable green in colour as in earth continuity wire connecting to common earth point and 1.6 mm thick mild steel sunken terminal boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point/ 3 pin 5 Amps socket outlet independent point controlled by one, one way switches complete including cCutting chase, pinning in making good to facings where required and pointing in cement mortar 1:3 complete all as specified and directed by the Engr-in-Charge. |
| 21 | All as per item No. 20.00 here-in-before butone3 pin 5 amp switch socket out let independent . all as specified and directed by Engineer-in-Charge. |
| 22 | All as per item No. 20.00 here in-before but for one 3 pin 5 amps socket outlet on the same board with other switch with conduit complete 2.5 sqmm multistradedall as specified and directed by Engineer in-charge. |
| 23 | All as per item No. 20.00 here-in-before but using2.5 Sqmm size stranded copper conductor cable for one 16 Amp switch 2.5 sqmm for socket outlet point on independent board completePVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dollyall as specified and directed by Engineer-in-Charge. |
| 24 | Material and Labour for Point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core, unsheathed, copper conductor cables drawn through and including PVC casing capingin walls, ceiling etc with all fittings and accessories of PVC conduits (like Tee, bend etc.) complete fixed to walls/ceiling etc. with and including 1.5 Sqmm (nominal area) FRLSH PVC insulated, unsheathed, multistranded, single core, copper cable green in colour as in earth continuity wire connecting to common earth point and 1.6 mm thick mild steel sunken terminal boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light/fan point controlled by one, one way switches complete including Cutting chase, pinning in making good to facings where required and pointing in cement mortar 1:3 complete all as specified and directed by the Engr-in-Charge. |
| 25 | All as per item No. 24.00 here-in-before butone3 pin 5 amp switch socket out let independent. all as specified and directed by Engineer-in-Charge. |
| 26 | All as per item No. 24.00 here in-before but for one 3 pin 5 amps socket outlet on the same board with other switch with PVC conduit complete 2.5 sqmm multistradedall as specified and directed by Engineer in-charge. |
| 27 | All as per item No. 24.00 here-in-before but using2.5 Sqmm size stranded copper conductor cable for one 3 pin 16 Amp socket outlet point on independent board completePVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dollyall as specified and directed by Engineer-in-Charge. |
| 28 | S&Fswitch piano flush type, single pole one way, 5 Amp complete all as specified and as directed. |
| 29 | Supply & fixswitch socket combination multi - purpose 6 pin, 15 amp and ,controlled by one switch flush type complete all as specified and as directed. |
| 30 | S&Fsocket out let 2 in 1 ,5 pin 5 Ampson the same board with other switch complete all as specified and as directed. |
| 31 | S&Fswitch socket combination 2 in 15 pin switch socket outlet 5A on independent board complete all as specified and as directed. |
| 32 | S&Fceiling rose, PVC/Polycarbonate, 65 x 50 mm,three terminals complete all as specified and directed. |
| 33 | S & F for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and as directed. |
| 34 | Supply and fix bell push switch, flush type 5 Amp complete all as specified and as directed. |
| 35 | S & Fcall bell, ding dongAC 230 volts, single pole completeall as specified and as directed. |
| 36 | S&Fceiling fan regulator electronic Step type, solid state, , 240 volts,complete all as specified and as directed. |
| 37 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 38 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 39 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 40 | Supply and fix Decorative wall light fixture made up of Polycarbonate, suitable for 9 W retrofit LED Lamp B22 base complete with all the connection as directed. |
| 41 | S&F building security light pressure die cast housing with individual LEDs with modular secondary optics security light luminaires 35 watt LED with 32 mm dia light grade GI pipe bent to shape 1.5 mtr long and nuts bolts including fixing arrangement after taking down old unserviceable one complete all as specified and as directed. |
| 42 | Dis-assembling carefully ceiling fans (any make) of 1200/1400mm sweep, cutting & removing old copper winding wire and rewinding the same with new super enameled copper wire of suitable size / gauge and weight not less than 325 gms including providing insulation by varnishing, oiling and greasing, replacing bearing and gun metal shaft required and reassembling back including testing complete.Note :- (i)Cost ofbearings provided shall be measured in this item and nothing will be paid extra on this account.(ii) Working space if required, willbe provided to the contractor for carrying out necessary rewinding/repair with in AGE E/M store yard premises(iii) If winded fan found unserviceable within six month of rewinding,contractor will repair the same without any extra cost.(iv)Cost of Machining work in body of ceiling fan by taking out worn out bearing, boring hole to accommodate ball bearings is included in this item and nothing shall be paid extra on this account.(v) Cost of carrying ceiling fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard (vi) Cost of shaft will be paid under appropriate item of Schedule. |
| 43 | Supply and fix capacitor 2.5 mfd to 3.15 mfddry type for Ceiling fan complete all as specified and as directed. |
| 44 | M&L for Preparation of old painted surfaces of the body, blades, down rod etc of ceiling fans of size 1200/1400mm sweep (any make) complete by rubbing with amery paper and filing in cavities with approved filler and applying one coat of spray painting with synthetic enamel paint (Glossy white/ pale cream) on the body, blades, down rods and writing MES /Fan no with black synthetic enamel paint complete all as specified & directed. |
| 45 | Supply and fix rubber bush complete with spring, nut bolt, fork hook and spilt pin, washer suitable for existing ceiling fan 1200mm/1400mm sweep complete all as specified and directed. |
| 46 | Supply and fix in repair Ceiling fan stator 48 inch sweep 12 mm copper winding including ,thick steel bolt with double nuts and locking pins and high quality rubber bushing to reduce vibration complete all as specified and directed. |
| 47 | Supply and fix in repairrotor complete suitable for 48 inch sweep ceiling fan all as specified and directed. |
| 48 | Supply & Fixceiling fan mild steel body set (upper & lower) with two set of bearings for ceiling fans of sweep 1200mm duly painted and any make and fixing in position complete all as specified and directed. |
| 49 | Supply and fix PVC canopy set (upper & lower) for ceiling fans withof size 1200mm to 1400 mm sweep and any make and fixing in position complete all as specified and directed by Engr-in-charge . |
| 50 | Supply and fix of aluminium blades with fan blade screws of ceiling fan forany sweep( 1200mm to 1400 mm) & of original make as per existing complete all as specified and directed by Engr-in-charge . |
| 51 | Supply & Fix MS heavy duty down rod of 15mm dia and 600mm length with necessary cutting / drillingholes and painting for ceiling fans including replacing old one complete all as specified and directed. |
| 52 | Supply only shaft for ceiling fan of sweep size 1200 to 1400 mm and fixing in position for smooth functioning of ceiling fancomplete all as specified and directed. |
| 53 | Dis-assembling of exhaust fan of size 250mm/ 300mm/400mm AC 230 Volts, 50 Hz 900/1400 RPM for repair, removing existing burnt winding wire, bearing/bushes, flexible wire, shaft, check nuts, frame and rewinding with super enameled copper windings wire of suitable size and weight not less than 450gms and replacement of bushes, bearings, shafts, check nuts, bolts and washers, greasing, varnishing and reassembling back including testing complete. Note :- (i)Cost ofbushes/bearings, provided shall be measured and paidin this item and nothing extra shall be paid on this account. (ii)Working space if required,willbe provided to the contractor for carrying out necessary rewinding/repair with in AGE E/M store yard premises.(iii) If winded exhaust fan found unserviceable within six month of rewinding,contractor will repair the same without any extra cost.(iv)Cost of Machining work in body of exhaust fan by taking out worn out bush, boring hole to accommodate ball bearings is included in this item and nothing shall be paid extra on this account.(v) Cost of carrying exhaust fan from site to the workshop and refixing of the same after repair is included in this item and all T&P and vehicle cost will be born by the contractor in this regard.(vi) Cost of shaft will be paid under appropriate item of Schedule. |
| 54 | M&L for Preparation of old painted surfaces of the body and blades, of exhaust fans of size 250/300mm sweep (any make) complete by rubbing with amery paper and filing in cavities with approved filler and applying one coat of spray painting with synthetic enamel paint (Glossy white/ pale cream) on the body, blades, down rods and writing MES /Exhaust no with black synthetic enamel paint complete all as specified & directed. |
| 55 | Supply only capacitor 4 mfd to 6 mfddry typefor exhaust fancomplete all as specified and directed. |
| 56 | M&L for brazing/gas welding of inner container copper of 25 ltrs /50 ltrs capacity and any make and making leak proof including taking down and refixing the geysers complete all as directed. |
| 57 | S & F heating element 2KW as per existing make of geyser complete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 58 | S & F thermostate for suitable existing geyser of 25/50 litrs capacitycomplete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 59 | S & F Chromium plated connection pipe of length not less than 60cm including washers for incoming & outgoing hot & cold water connections as specified and directed by Engr-in-charge |
| 60 | S & F Apparatus plate assembly complete for geyser of capacity 25/50 litrs capacitycomplete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 61 | S & F Outer casing made out of 22 SWG MS sheet suitable for geyser of capacity 25 litrscomplete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 62 | S & FStorage tank fabricated from MS sheet gauge suitable for geyser of capacity 25 ltrs of make as specified and approvedcomplete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 63 | S & F Split plate bottom cover made suitable for 25 litrs capacity geysercomplete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 64 | S & Finsulating material glass woolcomplete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 65 | S & F clamp with anchor fastener bolt complete including taking down of old unserviceable one and taking down and refixing the geyser complete all as specified and directed by Engr-in-charge. |
| 66 | S & FFusible metal plugcomplete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 67 | S & FNeon lamp round/square with connection leadcomplete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 68 | S & FNon return valve for geyser inletcomplete including taking down of old unserviceable one complete all as specified and directed by Engr-in-charge. |
| 69 | Supply and fix in replacement of louvers iron with shutters suitable for existing exhaust fan of any size and shape at site upto bldg of G+10 storey complete all as specified and directed by Engg-in-charge |
| 70 | Supply & fixing exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz , RPM 1200, Copper winding of sweep 300m. Including take out unserviceable and deposit to MES Store.complete all as specified and directed by Engg-in-charge MAKE- Bajaj/crompton/Havells |
| 71 | S & F In repair Hylem sheet of thickness 3mm used for Housing Switches, Sockets, Regulators of required size as per site requirement Including screws. Complete all as specified and directed by Engg-in -charge. |
| 72 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil for layiing of wter supply pipe line/UG cable complete all as specified and directed. |
| 73 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm as in soft/loose soil complete all as specified and directed. |
| 74 | Removing excavated material ( soils of any type) not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 75 | Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge.Note:- Thickness after punning down shall be measured for payment. |
| 76 | Supply and laying in trenches Bricks, sub class \"B\" over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge. |
| 77 | Laying only Old serviceable bricks in trenches obtained from taking out old unserviceable XLPE cable, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge. |
| 78 | Supply and laying DWC ( Double Wall Corrugated ) pipe of size 100mmfor the cable protection in trenchcomplete all as specified and as directed by the Engr-in-Charge. |
| 79 | Taking out unserviceable UG cables of any type and any sizes from trenches etc and removing from the site of work complete all as specified and directed.Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of these schedule. |
| 80 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 10 Sqmm 2 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. |
| 81 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 16 Sqmm 2 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. |
| 82 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 25 Sqmm 4 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. |
| 83 | S & F In Replacement of1.6 mm thick mild steel sunken terminal box sutaible for 5A SSC /15A SSC including painting with 2 coat of black bituminous paint & complete electrical connection including taking down of old unserviceable/rusted GI Box and Cutting chasing of wall,if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc.(Nothing will paid extra on this account)complete all as specified and directed by Engineer-in-charge |
| 84 | S & F In Repair/Replacement of1.6 mm thick mild steel sunken terminal box sutaible for ( 2 nos light point, 1 nos of fan point , 1 nos of same board point and regulator point ) including painting with 2 coat of black bituminous paint & complete electrical connection including taking down of old unserviceable/rusted GI Box and Cutting chasing of wall,if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc.(Nothing will paid extra on this account)complete all as specified and directed by Engineer-in-charge |
| 85 | M/L for Cutting of hole in exhusting wall for opning for exhaust fan and making good to facings where required and pointing in cement mortar 1:3 to ends or edges complete all as specified and directed by Engineer in charge. |
| 86 | S&Fin repair switch piano flush type, single pole one way, 5 Amp complete all as specified and as directed. |
| 87 | S&F in repair switch socket combination 2 in 15 pin switch socket outlet 5A on independent board complete all as specified and directed by engineer in-charge. |
| 88 | Supply & fixin repair switch socket combination multi - purpose 6 pin, 15 amp and ,controlled by one switch flush type complete. |
| 89 | Supply & fixPVC surface mounting box,white in colour for the sutable of 5A SSC & 15A SSC controlled by one switch flush type complete all as specified and directed by engineer in-charge |
| 90 | Materials and Labour Cutting /boreing of existing road / path , hardstandingetc for taking out cable and water pipe to protection with iron cover plate for passing cable,water pipe and making good the disturbed road top surfaces with following cement concrete all type, usingof suitable depth and finished withspeed breaker complete all as uder directed by Engineer-in-Charge. |
| 91 | Supply and laying GI pipe light grade with all fittings in trenches 50mm bore of GI pipe for cable protectioncomplete all as specified and directed by Engineer in charge |
| 92 | Servicing and maintance of Solar water heater plant of Cap 100/150/200/300 ltrs installed at bldg upto 10 storey for carrying out minor leakage, cleaning of flat plate collector glass, de-scaling of copper tube through approved chemical (Scalgun saf Liquid cleaning) incl necessary Tool and equipments for pumping arrangenmentlike pump etc. cleaning of water tank and make up tank including dismantling inlet and out let connections and refixing the same after cleaning for proper functioning to maintain proper water temperature all as specified and directed by Engr-in charge |
| 93 | S & F in replacement flat plate collector size approx 1860 mm x 1240mm x 90 mm/ or as per sample ISI markedas per site requirement assembly suitable for solar water system of existing size and capacity with copper tube black coat/radiation reflector film , toughed glass, complete all as specified and directed.Make:-supreme /venus/inter solar/umang/sunzone. Note :All the T & P , Hydra , Crane arrangement required for carrying/Displacingmaterial from ground to triple storage building shall be arranged by contractor at his own cost and thecost is inclusive in qouted rate. |
| 94 | S & F in replacement only solar toughened glass plate suitable for collector plate of size approx 1860 mm x 1240mm x 90 mmas per availlability at site complete all as specified and directed. Note:All the T & P , Hydra , Crane arrangement required for carrying/Displacingmaterial from ground to triple storage building shall be arranged by contractor at his own cost and thecost is inclusive in qouted rate. |
| 95 | S & F nytryl rubber suitable for Solar water heater plant of Cap 100/200/300 ltrsSolar water heater plant complete all as specified |
| 96 | S & Fin replacement temperature gauge steam type range 25 to 90 degree and above in centigrade as per existing size, complete all as specified. |
| 97 | M & L for replacement of insulator water tank made out of 1.25mm thick MS sheet with provision of 15mm dia inlet/outlet arrangement for solar water heater capacity150/200 ltrscomplete all as specified and directed. Make:-supreme /venus/inter solar/umang/sunzone.Note:All the T & P , Hydra , Crane arrangement required for carrying/Displacingmaterial from ground to triple storage building shall be arranged by contractor at his own cost and thecost is inclusive in qouted rate. |
| 98 | M & L for replacement of insulator water tank made out of 1.25mm thick MS sheet with provision of 15/20mm dia inlet/outletas per groung arrangement for solar water heater capacity 300 ltrscomplete all as specified and directed. Make:- supreme /venus/inter solar/umang/sunzone. Note:All the T & P , Hydra , Crane arrangement required for carrying/Displacingmaterial from ground to triple storage building shall be arranged by contractor at his own cost and thecost is inclusive in qouted rate. |
| 99 | M & L for replacement of rubber hose pipe 22 to 25mm dia between hot water tank & collector as per ground requirement complete all as specified .and directed |
| 100 | S & F in replacement top cover suitable forHDPE tankcap 100 to 500 ltrs complete all as specified and directed. |
| 101 | S&F Rotational Moulded Polyethylene (HDPE) Water Storage Tank 500Litre Capacity (Cylindrical Vertical with Closed Top), Black in Colour, Three Layered Construction, hoisted and fixed in Position all specified in MES Schedule Part-I including provision of 25mm x 100mm GI nippples with check nuts for inlet, outlet wash and overflow pipe including 15mm bore dia of pipe Ball valves high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball screwed for iron pipe and including Lowering of old/unserviceable Water Storage Tank of any description, complete all as specified and as directed. Note:All the T & P , Hydra , Crane arrangement required for carrying/Displacingmaterial from ground to triple storage building shall be arranged by contractor at his own cost and thecost is inclusive in qouted rate. |
| 102 | S&F cross arms, bracings supports, clamps and back plates fabricated from structural steel sections including nuts bolts, washers, welding bending cold or hot,drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed |
| 103 | S & Fin replacement CPVC tubing medium grade and fixed to walls & ceilling or laid in floors, bore of pipe 20 mm complete all as specified and directed. |
| 104 | S & Fin replacement GI tubing medium grade with all fitting and fixed to walls & ceilling or laid in floors, bore of pipe 15 mm complete all as specified and directed. |
| 105 | All as per item No 103.00 here in before but bore of pipe 20 mm complete all as specifiedand directed. |
| 106 | All as per item No 103.00 here in before but bore of pipe 25 mm complete all as specifiedand directed. |
| 107 | S & Fin replacement 15 mm bore gun metal gate/stop valve (ISI Mark) with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 108 | All as per item No 107.00 here in before but gun metal gate/stop valve 20 mm complete all as specifiedand directed. |
| 109 | All as per item No 107.00 here in before but gun metal gate/stop valve 25 mm complete all as specifiedand directed. |
| 110 | All as per item No 107.00 here in before but gun metal gate/stop valve 50 mm complete all as specifiedand directed. |
| 111 | S & F Float ball valve 25mm sizehigh pressure ,polythene float an flynut complete , screwed for iron pipe or brass ferrule and fixed. |
| 112 | Supply and fix thermostat of Type EST11 / 20A, 240Volt of approved make and having ISI mark complete all as specified and directed. |
| 113 | S & F heating element 2kW to be fixed in heating tank complete with connection all as specified and directed. |
| 114 | S&F in repair Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dollyetc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- (i)Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC conduit will be measured as one length. (ii) Cost of taking down existing submain wiring including all accessories is included in this item and nothing will be paid extra on this account |
| 115 | M&L for cleaning ofwater storage tank of cap upto 2000 ltrs with bleaching powder by blocking the inlet/outlet flow from manholes, lifting the excess semi-solid water out of the sump, removing the entire deposited sludge, mud, silt etc scrapping the internal wall/floor with wire brush (to remove deposited scales, mud etc from the walls/floors by using suitable T&P manually from the bottom of the tank) and removing the same at a distance n exc 50m from the site where directed,opening the blocked holes etc before normalising flow complete all as specified and as directed by Engr -in-charge. Note contractor has to pump out the storage water at his own arrangement before cleaning the the tank) |
| 116 | M & L for pressure reducing valve 25mm to 50mm made of stainless steel with min pressure 1kg per cm sq with mac temp of 70 C threaded to both ends to be fixed in 5th floor in duct complete all as specified and directed by engr in charge. |
| 117 | Taking down carefully Window Type / Split Type / Tower Type Air Conditioner 1/1.50 / 2.00/3 Ton capacity, from its location and removing dirt and dust from interior and exterior of the Air Conditioner and washing the condensor and evaporator with varmi clean solution and other areas by soapsolution, spraying pressurised water on condensor and evaportor with proper protection of electrical fixtures and connection, drying by blowing air, andplacing in same position complete all asdirected . |
| 118 | Taking down unserviceable Rotary/reciprocatory Compressor from Air Conditioner Window Type / Split type 2 Ton capacity of any make & type and Supply and Fixing reconditioned sealed compressor suitable for 2.0 TRwindow/split type Air conditioner including vacumminishing, initial charging of oil along with newfoundation rubber pads, nut and bolts including testing on full loadcomplete all as directed Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. |
| 119 | All as per serial item No. 118.00 above but for air conditioner ofwindow Type / Split type 1/1.5 Ton capacity |
| 120 | Taking down unserviceable Rotary/reciprocatory Compressor from Air Conditioner Window Type / Split type 2.0 Ton capacity of any make & type and Supply and Fixingnew sealedrotary type compressor suitable for2.0TRwindow type/split type Air conditioner including vacumminishing, commissioning ,testing and initial charging of oil of air conditioner along with newfoundation rubber pads, nut and bolts including testing on full loadcomplete all as directed Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. |
| 121 | All as per serial item No. 120.00 above but for air conditioner ofwindow Type / Split type 1/1.5 Ton capacity. Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. |
| 122 | All as per serial item No. 120.00 above but for inverter ACofwindow / Split type of capacity 2.0 ton. Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. |
| 123 | Supply and fixing in repair compressor 2.5 TRper existing make 3 phase including vacumminishing, commissioning ,testing and initial charging of oil complete all as directed including taking down old unserviceable one complete.Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. |
| 124 | Supply & fixing of new strainerincluding testing including taking down old unserviceable one complete all as specified and directed . |
| 125 | S&F copper capillary tube with filter of appropriate quality and size to match in existing including jointing, brazing and testing suitable for window/split type AC\"s of 1/1.5/2.0 TR capacity including taking down old unserviceable one complete all as directed. |
| 126 | S&F capacitor of 2.5 to 10 MFD capacity, AC 240 volts and 50 Hz including taking down of old unserviceable capacitor complete all a specified and directed.Make : Universal/sarada/power. |
| 127 | S&F capacitor of 25 to 60mfd capacity AC 240 volt and 50 Hz including taking down of old unserviceablecapacitor complete all as specified and directed .Make : Universal/sarada/power. |
| 128 | M & L for providing new wooden frame of size 50mmx50mm including removing old one and reinstalling existing AC and making electrical connection including all connected items complete all as specified and directedby |
| 129 | S&F in repairply wood board of 6 mm thick cut into sizes as required at site for AC with and including support for fixing of ply wood and painting with one coats of synthetic enamel paint over a coat of pink primer complete all asdirected by Engineer-in-Charge. |
| 130 | Supply and Fixing in replacementold unservicable chassis body of window AC unit made out of MS sheet alongwith new cabinet cover as per same size suitable for 1.5/2.0 Ton ACduly spray paintedwith two coats of synthietic enamel paint (shade of colour as approved by Engineer-in- Charge) ,suitable for installing evaporator coil, condenser coil ,copper wounded fan motor, blower and fan blade and suitable front grill etc, remote sensing unit and wiring complete all as directed |
| 131 | S&F in repair Plastic Front Grill assembly alongwith PVC filter complete suitable for any make of window type 1.5 / 2.0 tone Air Conditioner complete all as directed by Engineer-in-charge. |
| 132 | S&F of Air filter for AC window/split type for 1/1.5/2 TR capacity including taking down old unserviceable one complete all as specified and directed. |
| 133 | S&F in repairEvaporator cooling coil and fins made out of copper tubing at appropriate spacing complete in all respects suitable for Window Type of capacity 1/1.5/2.0 Ton including brazing/welding etc. complete all as directed. Note:(i) Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. (ii) Cost of newfoundation rubber pads, nut and bolts including testing on full loadcomplete is included in this item |
| 134 | S&F in repair Condensor cooling coil and fins made out of copper tubingat appropriate spacing complete in all respects suitable for Window Type of capacity 1/1.5/2.0 Ton including brazing/welding etc. complete all as directed Note:(i) Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. (ii) Cost of newfoundation rubber pads, nut and bolts including testing on full loadcomplete is icluded in this item |
| 135 | S & F fan motor double spindle for window AC1/1.5/2 TR with appropriate gauge of super enameled copper conductor to match with the existing design including heat varnishing, overhauling, testing and re-fixing the same after taking down the old unserviceable one complete all as specified and directed. |
| 136 | S&F in repair Fan blower suitable for Window Type Air Conditioner as per existing of capacity 1TR/1.5 Ton / 2.0 Ton complete all as directed. |
| 137 | S&F in repair Fan Blade suitable for Window Type/ SplitType Air Conditioner outdoor unit of capacity 1/1.5 Ton / 2.0 Ton complete all as directed. |
| 138 | S & F in repair base tray for window AC made of sheet metal complete allas specified and directed. |
| 139 | S&F of drain pipe with drain cap of window& split type AC230 volt, single phase for (1/1.5/2.0 TR ) including taking down old unserviceable one complete all as specified and directed. |
| 140 | S&F in repair thermostat used for sensing and temperature control suitable for Window Type/ split type Air Conditioner 1/1.5 Ton/ 2.0 Ton complete all as specified and directed |
| 141 | Taking out unserviceable Blower motor from the indoor unit split TypeAir Conditionerof any make / type / capacity and supply and fixing new Blower motor of same make / type / capacity including nut and bolts if required complete all as directed by Engr-in-Charge. |
| 142 | Dismantling of unserviceable motor from the Air conditioner of 2.0/1.5/1.0 Tonne capacity and re-winding of fan motor with appropriate gauge of super enameled copper conductor to match with the existing design including heat varnishing, overhauling, testing and re-fixing the same complete all as specified and directed . |
| 143 | S & F fan motor of outdoor unit of Split AC of 1/1.5/2TR capacity with appropriate gauge of super enameled copper conductor to match with the existing design including heat varnishing, overhauling, testing and re-fixing the same after taking down the old unserviceable one complete all as specified and directed. |
| 144 | S&F in repair PCB including Remote Control for remote sensing and operation suitable for Window Type/ Split Type Air Conditioner 1.5 Ton/ 2.0 Ton make as approved by Engineer-in-charge. |
| 145 | M & L for reparing PCB board of AC 1/1.5/2.0 TR capacity of suitable for window/SplitAC including taking down old unserviceable one complete all as specified and directed. |
| 146 | S & F in repair PCB board for inveter type AC 1.5/2.0 TR capacity of suitable for window/SplitAC with remote including taking down old unserviceable one complete all as specified and directed. |
| 147 | S & F sensor ofAC 1/1.5/2.0 TR capacity of suitable for window/SplitAC including taking down old unserviceable one complete all as specified and directed. |
| 148 | Supply and filling refrigerant gas R-22 for ACcomplete including testing all as specified and directedby Engr-in-Charge. |
| 149 | Supply and filling refrigerant gas R-32 for ACcomplete including testing all as specified and directedby Engr-in-Charge. |
| 150 | S & F bush bearing of blower fan motor for window/split type AC, including taking down old unserviceable one complete all as specified and directed . |
| 151 | M&L for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-22/R-134/R-32/R-410/R-600 upto the required pressure for 1.5 / 2.0 Ton Window Type / Split TypeAir Conditioner complete all as specified and directed by Engineer-in-charge.Note :- (i)The cost ofgas is included in this item and nothing extra shall be paid on this account.(ii) The cost of capillary/drier/flare nut if required is included in this item item and nothing will be paid extra on this account |
| 152 | S & F in repair inner unit bracket / wall stand of inner unit of split type AC of capacity 1/1.5/2 TR including taking down old unserviceable ones complete all as specified and directed. |
| 153 | S&F in repairEvaporator cooling coil and fins made out of copper tubing at appropriate spacing complete in all respects suitable for indoor unit of split Type of capacity 1.5/2.0 Ton including brazing/welding etc. complete all as directed. Note:(i) Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. (ii) Cost of newfoundation rubber pads, nut and bolts including testing on full loadcomplete is included in this item |
| 154 | S & F in repair blower/runner of Inner unit including bush of AC of capacity 1/1.5/2 TR including taking down old unserviceable ones complete all as specified and directed. complete all as specified and directed. |
| 155 | M & Lfor PVC copper cable for min. 2.5 sqmm 3 core core for connecting the indoor and outdoor unit of split type ACs complete all as specifed and directed. |
| 156 | M & Lfor PVC copper cable for min. 2.5 sqmm 4 core for connecting the indoor and outdoor unit of split type ACs complete all as specifed and directed. |
| 157 | S&F in replacement of blower fan by taking down of the outer unit of split AC of capacity 1/1.5 TR testing complete all as specified and directed by Engr-in-charge . |
| 158 | S&F in repair Condensor cooling coil and fins made out of copper tubingat appropriate spacing complete in all respects suitable for split Type of capacity 1.5/2.0 Ton including brazing/welding etc. complete all as directed Note:(i) Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. (ii) Cost of newfoundation rubber pads, nut and bolts including testing on full loadcomplete is icluded in this item |
| 159 | S & F in repairs flare nut with dead cap suitable for AC any type complete all as specified and directed by Engr-in-charge . |
| 160 | S & F in repairs valves of size 1/2\", 1/4\", 3/8\",5/8\" suitable for AC any type complete all as specified and directed by Engr-in-charge . |
| 161 | S&F in repair Copper pipe with insulation 1/2\" dia, superior quality suitable for refrigerationof split ACs, drawn through/fixed to walls or roof complete all as directed |
| 162 | S&F in repair Copper pipe with insulation 3/8\"\" dia, superior quality suitable for refrigerationof split ACs, drawn through/fixed to walls or roof complete all as directed |
| 163 | S&F in repair Copper pipe with insulation 5/8\"\" dia, superior quality suitable for refrigerationof split ACs, drawn through/fixed to walls or roof complete all as directed |
| 164 | S&F in repair Copper pipe with insulation 1/4\" dia, superior quality suitable for refrigerationof split ACs, drawn through/fixed to walls or roof complete all as directed |
| 165 | Supply of remote control unit of window/split AC as per original make of AC or compatibility of ACs complete all as specified and directed by Engr-in-charge . |
| 166 | Supply of universal remote control unit of window/split AC complete all as specified and directed by Engr-in-charge . |
| 167 | S &F Bracket heavy duty for outdoor unit of AC including taking down old unserviceable one and necesarry PCC work complete all as specified and directed. |
| 168 | S&F of contactor assembly for 2.0 /1.5/1TR split type AC single phase 230 voltcondensing unit of any make including taking down old unserviceable one complete all as specified and directedby Engr-in-Charge. |
| 169 | Taking out unserviceable unit and Supply and install window AC unit complete of capacity 1.5 TR with 3 star rating and connection complete including drain pipe complete all as directed. |
| 170 | Taking out unserviceable indoor unit and supply and install indoor unit of split AC unit complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality of capacity 1.5 TR with 3 star rating ,connecting pipe with complete insulation and coooneting with outdoor unit complete all as specified and directed. |
| 171 | Taking out unserviceable outdoor unit and supply and install outdoor unit of split AC unit complete of capacity 1.5 TR with 3 star rating and connecting pipe with complete insulation.. |
| 172 | Taking out of unserviceable compressor sealed unit from refrigerator of capacity 286/300/320 ltrs or deepfreezer 400Land Repairing ofcompressor servicing, flashing refixing the repaired compressor after leakage testing, vaccummision the system gas charging complete all as specified and directed.Note: Cost of charging of gas is not included in this item and will be paid under Appropriate item of schedule. |
| 173 | S&F in repair Starting Relay Assembly with Over Load Protector any model complete all as directed. |
| 174 | Taking out of unserviceable thermostat switch & supply and fixing of thermostat for refrigerator of 165 to 310 Lts capacity complete all as specified and directed by Engr-in-Charge. |
| 175 | Taking out of unserviceable lamp holder including lamp case and S & F of new pigmy lamp holder and lamp case to match with the existing, suitable for refrigerators of any capacity complete all as specified and directed by Engr-in-Charge. |
| 176 | M & L forRefrigerant -(R-134A)complete all as specified and directed by Engr-in-Charge. |
| 177 | Taking out of old unserviceable strainer of refrigerators of any capacity including supplying and fixing of new strainer of approved quality to match with the existing complete all as specified and directed by Engr-in-Charge. |
| 178 | Taking out of old unserviceable door lock of refrigerator of any capacity & S/F of new door lock to match with the existing size complete all as specified and directed. |
| 179 | Taking out unserviceable cooling coil and Supply and Fixing cooling coil with condenser assembly for refrigerator of any capacity as per existing samples complete all as specified and directed. |
| 180 | S&F Adjustable shelves for refrigerator of any capacity as per existing samples complete all as specified and directed by Engr-in-Charge. |
| 181 | S&F Bottle retainer/shelves for refrigerator of any capacity as per existing samples including taking down old unserviceable one complete all as specified and directed. |
| 182 | S&F door handle for refrigerator of any capacity as per existing samples including taking down old unserviceable one complete all as specified and directed. |
| 183 | S&F freezer door as per sample including taking down old unserviceable one complete all as specified and directed. |
| 184 | S&F chill tray of any type/ capacity/ make as per sample including taking down old unserviceable one complete all as specified and directed. |
| 185 | S&F vegetable tray of any type/ capacity/ make as per sample including taking down old unserviceable one complete all as specified and directed. |
| 186 | S&F ICE tray of any type/ capacity/ make as per sample including taking down old unserviceable one complete all as specified and directed. |
| 187 | S&F Capillary tube size with filter to any type of refrigerators complete all as specified and directed by Engr-in-Charge. . |
| 188 | S & F heater of refrigerator of capacity upto 320 liters complete all as specified and directed by Engr-in-charge . |
| 189 | S & F magnetic gasket of refrigerator door of capacity upto 320 liters complete all as specified and directed by Engr-in-charge . |
| 190 | S & F timer for defrost of refrigerator of capacity upto 320 liters complete all as specified and directed by Engr-in-charge . |
| 191 | S & F condenser coil of refrigerator of capacity upto 320 liters complete all as specified and directed by Engr-in-charge . |
| 192 | Dismantling of worn out outer body of refrigerator and repairing by replacement to worn out portion of the body by welding/fabricating with approved quality and MS Sheet/PVC sheet to match with the existing shape including,refixing of all the dismantled enclosures of the refrigerator in position including testing, painting and commissioning complete all as specified and directed . |
| 193 | Taking out Water cooler upto 150L/150L capacity from the existing place for repairing of compressor, servicing, and refixing the repaired compressor, leakage testing, vaccummision the system gas charging completely complete all as specified and directed.Note: Refrigerant measured separately. |
| 194 | S&F Bush of fan motor for water cooler of capacity upto 150/150L including taking down old unserviceable one complete all as specified and directed. |
| 195 | Taking out unserviceable relay from water cooler of capacity upto 150/150L Ltrs capacity (for 1/3 HP compressor) and S&F of new relay to match with the existing complete all as specified and directed. |
| 196 | Taking out of unserviceable thermostat switch & S/F of new thermostat switch to the water cooler of any capacity complete all as specified and directed. |
| 197 | S & F copper capillary tube for water coolers including taking out of old unserviceable tubes complete all as specified and directed. |
| 198 | Dismantling of worn out outer body of water cooler and repairing by replacement to worn out portion of the sheet metal body by welding/fabricating with approved quality and MS Sheet to match with the existing shape including,refixing of all the dismantled enclosures of the water cooler in position including testing, painting and commissioning complete all as specified and directed. |
| 199 | Taking out of existing worn out and perished rubber gasket of water cooler tank cover and S & F of new gasket as per existing sample for any capacity of water cooler complete all as specified and directed. |
| 200 | Taking out of existing worn out and unserviceable water faucets of any type 15 mm bore and S & F of cast copper alloy chromium plated push type / lift tap water faucets of 15mm bore complete all as specified and directed. |
| 201 | Taking out of existing worn out and unserviceable float valve 15mm bore of any type and S & F ofball valve of 15mm dia including inlet nipple and connecting unions etc complete all as specified and directed. |
| 202 | Taking out of worn out drain pipe including drain tray and repair the same and drain pipes to match with the existing for any capacity of water coolers complete all as specified and directed. |
| 203 | Taking out of old unserviceable top cover lock of water cooler of any capacity and S&F of new top cover lock to match with the existing complete all as specified and directed. |
| 204 | Supply and fix Voltage stabilizer for automatic operation, single phase naturallyair cooled indoor type & designed for input variation between 130 V to 295 V with output voltage stabilized at 230 V with accuracy of ± 2.5%LED Display wall mounted and of capacity 4 KVA. complete all as specified and directed by Engr-in-charge . |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail