| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section embeded in concrete, including takingout embedded portion and making good disturbed ground complete all as specfied & as directed. |
| 2 | Excavation in post holes (or similar holes) each n.exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm watering and removing surplus soil to a distance n.exc 50m and making good complete all as directed. |
| 3 | M&L PCC 1:3:6 type C-2(40 mm graded aggregate) in foudations,filling and mass concrete. |
| 4 | Mild steel work as in (angle iron) as inflat iron,fencing post, struts incl cutting top shape as directed bent to shape drilling holes, hotching for wire etc complete confirming to FE-410-0 or 310-0 |
| 5 | Dismantling fencing wire mesh, any type complete all as specfied and as directed. |
| 6 | Fixing only chain link fencing including line wires, any mesh size and type of standards rails scraining babs etc incl permission of binding wire. Note : Supply of chain link will be measured seperately. |
| 7 | Supply only chain link PVC Coated GI Chain Link Fencing Mesh of any mesh size and type. Note. Fixing shall be measured under serial item no here in above. |
| 8 | S&F in repairs galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbsat 75mm spacing and straining and fixing to any type of standard rails strain-ing bolts, including, tying at crossing with and provision of galvanised mild steel wire, staple or steel pins etc as directed by EIC (each line wire to be measured). |
| 9 | Resecuring incl making good staple and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (eachline wire to be measured) |
| 10 | S&F in repairs barbed razor type concertina coil 9 SWG hot galvanised spring tensile wire of UTS 145 to 150 Newton per square mm zinc coating 250-300 grams per sqm dia of coil when unstretched 460 mm covering 8 to 10 running meter per coil and minimum weight of coil (GI strip) 1.625 kg per running metre hot dip galvanised razor ribbon tape of size 0.50 mm thickness, 19 mm wide before wrapping on central core wire fixed 1.66 mm thick GI clip minimum 25 nos per running metre and special nut bolt to hold two coils together and extra two rows parallel wire of 10 gauge complete all as specified and as directed . |
| 11 | Preparation of new steel surfaced of any description exc 10cm in width or girth and applying 2 coats of synthetic enamel paint over coat of red oxide primer complete all as specified and directed. |
| 12 | Demolition of brick or strone / boulder work, built in cement mortar in portion/ part ordered to be dismantledincluding all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing debrish from outside defence land complete all as specifed. all as specified. |
| 13 | M & L brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 |
| 14 | Taking down cement or cement lime plaster on brick or stone walls, any description , ncluding raking out joints, hacking for key, scrubbing down with water, etc. and removing debrish from outside defence land complete all as specifed. |
| 15 | M&L plastering15mm thick in CM 1:4 on brick or concrete surfaces on external surface of walls in two coats(10mm thick backing coat and 5mm thick setting coat) mixed with water proofing compound finished fair & even without using extra cement. |
| 16 | Providing and applying fair finish 15mm thick plasterwith ready mix prepacked proportioned dry mix mortar fair faces of brick wall or concrete surfaces ,wall surfaces including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-charge. |
| 17 | Supply only water proofing compound ISI marked. |
| 18 | M&L for applying Two or more coats of 100% Premium acrylic emulsion paint afert preparation of surface having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives over and including priming coat of exterior primer applied over new surfaces. Complete all as specified and directed. |
| 19 | Preparing of old decorated surfaces of walls by washing the surfce thoroughly, filling the cracks, craves with crack-filling-compound (Make :DR FIXIT CRACK SHRINK FREE or Equivalent ) applying one coats of acrylic emulsion exterior grade (100%) etc all as specified. Note : - (a) Old surface shall be cleaned with bleaching powder as specified and as per manufacturers instructions , all cracksshall be filled with white cement and sand mortar (1:3) by making V- grooves . (b) Acrylic painting shall be done with rollers.(c) Funges formation be cleaned throughly with wire brush or by any means. |
| 20 | Dismantling wrough iron or mild steel work of any description not otherwise provided for embedded in PCC /Brick workall as specified and directed. |
| 21 | M & L Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, gate; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe Fe 290 Gde E-165all as specified and directed. |
| 22 | All as per item No 21 above but for ornamental and intricate design. |
| 23 | S & FRolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe 290 Gde E-165. |
| 24 | M&L MS plate plain/ Chequered of requitred thicknes over as in manhole cover fixed to angle iron frame with three Nos of hingeg and 150mm handle. complete all as specified. |
| 25 | S&F 10 mm dia 100 mm long dash through fasteners bolts fixed in concrete or brick work to hold brackets etc complete |
| 26 | Dismantling of Plain or corrugated FRP /Steel chajja any Guage thickness including all fittings and removal from MD land complete all as complete all as directed by Engr In Charge |
| 27 | S & F Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 28 | All as per item No 27 here-in–before but except sheeting at any place or loc all as directed & specified by EIC (any thickness). |
| 29 | Cutting chases, pinning in and making good to facings of brick/concrete/stone walling where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.;and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girthcomplete all as specified and asdirected by Engg-In- Charge. |
| 30 | M&L for filleting in any position and to any shape of section area not exc 25 sq cm in cement sand mortar 1:4 including all mitres, stops etccomplete all as specified and asdirected by Engg-In-Charge. |
| 31 | Dismantling stone slab including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 32 | M&L for Machine pressed precast coloured glazed concrete interlocking paver block withgrey cement & pigment, glossy finish (reflective type) any shape and size (as approved by GE) confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, as in pavements to required level & gradients, set, jointed with clean dry sand and sealing the ends using PCC 1:2:4etc complete. |
| 33 | M&L for Sand filling under floors or in foundationincluding watering and consolidation etc complete. |
| 34 | M&L coloured glazed cement concrete chequered tiles 300 x 300 x 25 mm thick, machine pressed, glossy finish (reflective type), any design (as approved by GE); set jointed and pointed in neat cement slurry over and including 20 mm thick cement screed in cm 1:6 complete (Note : Cost for 20 mm thick cement screed is inclusive in the rate.) |
| 35 | M & L for two coats of floor guard paint (Indigoor Equivalent) on old surfaces of chequered tiles/paver blocks in floor including brooming and cleaing the surfaces with water complete all as directed. |
| 36 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) & pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & as directed by Engr-in-Charge. |
| 37 | M&L for 16 to18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified. |
| 38 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situationscomplete all as specified and as directed by Engr-in-Charge. |
| 39 | Cleaning existing drainage / culverts of any depth including removing cover slabs/grill , soils , spoils , vegetation , silt etc and refixing/placing of removed cover slabs/grill including making good in cement mortar 1: 3 and removing material outside the MD land complete all as directed and specified. |
| 40 | Dismantling cast iron work of any description |
| 41 | S&F Cast iron work grade FG 150, unmachined in gratings ,frames,manholecovers ,gully traps etc of articles exc 5 kg each complete all as specified and directed |
| 42 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all as specified. |
| 43 | Returinng filling in including spreading, leveling watering and well ramming in layer n.exc 25cm thick hard /densed soil all as specified |
| 44 | Removing excavated material from MD land exc. 1.50 km but n exc. 5 km and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 45 | M & L for 600mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and jointed including taking down old one complete allas specified. |