| 1 | Disconnecting and taking down exiting unserviceable Street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. Repairing/replacing unserviceable partsrefixing the same on pole/wall after testing and removing of carbon from line jumpers/Tightening of jumper/alligment of fittingdefective street light/security light/flood lights fitting/LED light from electric pole completeall as directed. Note:Spare parts and accessories such as LED Driver,and connected items etc will be measured and paidseparately under respective item as supply only and fixing is deemed to be included under this item. |
| 2 | Supply only LED street light Driver for 45 Watts LED Street light complete all as specified and directed. |
| 3 | Supply only LED street light Driver for 60 Watts LED Street light/ Flood light type complete all as specified and directed. |
| 4 | Supply only LED street light Driver for 100 Watts LED Street light/ Flood light type complete all as specified and directed.. |
| 5 | Supply and fixin repair LED streetlightof 45 Watt comprises of pressure die cast Aluminium housing & having system efficiency>123 lumens/Watt i.e 5570 lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 5KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected,THD<10%,CRI>70CCT 5700+/-300K,PF>0.9,Driver efficiency>85%,LM79 report require from NABL Accediated lab including taking down old unserviceable fittings complete all as specified and directed. Make : Philips, wipro and crompton cat part No : 423-45-57-SL-NS-GL-NSG |
| 6 | Supply and fixin repair LED streetlightof 60Watt comprises of pressure die cast Aluminium housing & having system efficiency>110 lumens/Watt i.e 6670 lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 5KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected,THD<10%,CRI>70CCT 5700+/-300K, PF>0.9, Driver efficiency>85%,LM79 report require from NABL Accediated labincluding taking down old unserviceable fittings completeall as specified and directed. Make : Philips, wipro and crompton cat part No : 421-60-57-SL-LM--NSG |
| 7 | Supply and fixing in repair LED flood light 100 watt 230 V AC, 6000K outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lampincluding taking down old unserviceable fittings complete all as directed. Make : Philips, wipro and crompton cat part No : CFS- 504-100-57-60D-SL-GL-NSG |
| 8 | S&F in repair 1100 volts grade 2.5 Sqmm twin core flat heavy duty cable PVC insulated,PVC sheet with aluminium conductors, multistranded served with an inner sheathing of PVC tape and overall PVC shathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm dia GI suspension wire including disconnection and removing the unserviceable cable. complete all as specified and directed. |
| 9 | S&F in repair 1100 volts grade 4 Sqmm twin core flat heavy duty cable PVC insulated,PVC sheet with aluminium conductors, multistranded served with an inner sheathing of PVC tape and overall PVC shathed in service connections . complete all as specified and directed. |
| 10 | S&F in repair street light bracket made out of 25mm dia light grade pipe 1.2 mtr long bend to shape along with two FI clamp made out of 20mmx3mm including nut, bolt, washers all as directed and taking down the existing bracket complete all as specified and directed. |
| 11 | Supply & Fix in repair steel tubing GI light grade 50mm bore for cable protection passing under Road/Floor or for fixing to poles all as specified and directed. |
| 12 | Taking out LT XLPE/PVC insulated armoured cable alongwith all joints of any size from trenches wall/roof/trenches completeallas directed . |
| 13 | Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 10 Sqmm x 2 core including laying, testing and commissioning complete all as specified and directed |
| 14 | Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 16 Sqmmx 2 core including laying, testing and commissioning complete all as specified and directed |
| 15 | Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 25 Sqmm x 4 core including laying, testing and commissioning complete all as specified and directed |
| 16 | Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area16 Sqmmx 4 core including laying, testing and commissioning complete all as specified and directed |
| 17 | Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 10 Sqmm x 4 core including laying, testing and commissioning complete all as specified and directed |
| 18 | Excavationin trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipeand getting out insoft/loose soilincluding trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed. |
| 19 | Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cmafter laying of cables including spreading, levelling, watering, and well ramming completeallas directed. |
| 20 | Removing surplus excavated soil to a distance n.exc. 50 metre anddepositing where directed at a level n.exc.1.5 metre high from the starting pointallas directed . |
| 21 | Supply and fixing Double wall Corrugated High Density Polymer Ethylene (HDPE) pipe of 50 mm sizes as per IS 14930 (Part-2):2001, Laid in trenches/floors and fixed on walls/poles, with and including neccessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed. |
| 22 | S&F MCB TPN 63 amps415 volts Complete all as specified and directed including taking out old one complete all as specified and directed. |
| 23 | S&F MCB SPN 32 amps230 volts Complete all as specified and directedincluding taking out old one as per directed. |
| 24 | Supply and fix Galvanised steel tubes, light grade of 40 mm diafixed with ClampinPCC pole including Cement work all as directed. |
| 25 | Road cutting for UG cable under road/railway crossing, pavement, hardstanding by mannually means, protection GI pipe for cable of required dai and making it good to match with the adjoining surface/structure for after cable passing complete all as specified and directed. Note : GI pipe and PCC will be measured and paid against respective items. |
| 26 | Supply and fixingin repair 1100 volts grade 0.75 Sqmm threecore FR PVC round sheathedcopper conductors (flexible) industrial cableconfirming to IS694suitable for connection street lights complete all as specified and directed. |
| 27 | Repair/Replacementof Nature Switch Smart Timer based Automatic Street Light Control Panel. The Panel should be suitable enough to take Single-phase Nature Switch Smart Timer should be maintenance-free in design and settings accessible via a Mobile App (with Bluetooth connectivity). The Mobile App should allow users to customize the ON & OFF timings based on Natural Light (sensor), Local Sunset/Sunrise (Astro) and Time. The Mobile App should also have facility to set Input Voltage range. The Smart Timer along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Rust Proof, Electric Shock Proof, Termite proof and FR grade thermoplastic polycarbonate Enclosure (with HINGED LID) conforming to IP66 protection class 2. The circuit should also have provision forManual Operation (i.e. Sensor By-Pass option) &In single-phase model, Controlling current phase selection option (at least from 2 phases Single-Phase load of 8kW (Navdeep-66-8kW1P) with Contactor, Incoming & Outgoing MCB rating of 40-63Amps & main load Circuit Wiring (Copper) of min.10 sq.mm |
| 28 | Repair/Replacementof Nature Switch Smart Timer based Automatic Street Light Control Panel. The Panel should be suitable enough to take three -phase Nature Switch Smart Timer should be maintenance-free in design and settings accessible via a Mobile App (with Bluetooth connectivity). The Mobile App should allow users to customize the ON & OFF timings based on Natural Light (sensor), Local Sunset/Sunrise (Astro) and Time. The Mobile App should also have facility to set Input Voltage range. The Smart Timer along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Rust Proof, Electric Shock Proof, Termite proof and FR grade thermoplastic polycarbonate Enclosure (with HINGED LID) conforming to IP66 protection class 2. The circuit should also have provision for Manual Operation (i.e. Sensor By-Pass option) &In 3-phase model, Controlling current phase selection option (at least from 3 phases load of 16kW (Navdeep-66-16kW3P) with Contactor, Incoming & Outgoing MCB rating of 40-63 Amps & main load Circuit Wiring (Copper) of min.16 sq.mm |
| 29 | Dismantlig, repairing and refixing of exixtingunserviceableHigh Mast lights/flood lights any type/watts from pole 16 meter to 21 meter hight, including dismantling the light fittings and repair/replacement of unserviceable componets aswinch/rope, mount floods lights wiring,raising and lowering mechanism including motor , safety lock Lantern carriage suitable to fix 6-12 nos. of luminaries symmetrically.,Trailing Cable (1 sets 5 core x 2.5 sq. mm. EPR PCP Round Copper) complete all as specified and directed by EICNote: Inclusive all labours,tools, crane for dismantling and refixing , Spare parts only such as LED Food light and aviation lightwill be measured and paidseparately under respective items. |
| 30 | Supply install, testing and commissioningOutdoor,in replacement of LT Distribution Panel Feeder Pillar (CPRI approved) Cubicle type,IP-56,outdoor type confirming to IS: 61439 Part I & II factory fabricated made out ofouter cover with 3 mm thick CRCA sheet & inner cover with 2mm thick CRCA sheet ofsuitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing MCCBs feeders. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. The cubicle shall have a bottom and four legs (400mm long) of size 50x 50x6 mm, The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, andfixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of followingall as specified and directed by EIC. Note :- PCC work shall be included in quoted rate. complete all as specified and as directed by EIC. (Location : High Mast Pole at RA and DA)(I) Incoming :- (i) Aluminium busbar, 4 Pole, 100 Amps (ii) SPD (Type 2) 3P+N, 20-40kA) - 01 No..(iii) MCCB 4P, 63A, 10 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 No.(iv)Ammeter Digital type, CT operated 0-630A range, MAKE: SECURE / L&T (with selector switch and CT) - 01 Set(v)Volt Meter Digital type 0-500 V range, Make:SECURE / L&T(With selector switch) - 01 No.(vi ) Indicating Lamp LED type 240 V 50 HZ AC supply (Make BCH/SIEMENS/L&T) set of three colour (RYB)-01 set.(vii) Contactor 3P, AC-3 rated for motor/lighting switching, 40A -01 No (viii) Timer (Astronomical + Programmable) with aoutomatic override & battery backup, sunrise/sunset based, DIN-mount -01 No(II) Outgoing :-(i) MCB TPN, 63A,= 02 Nos. (ii) MCB TPN, 32A= 100% ICU= 03 Nos. (iii) POWER CONTACTOR 18 A 3 POLE ( MAIN ) = 1 Nos(iv)POWER CONTACTOR 9 A 3 POLE ( UP & DOWN ) = 02 Nos(v) PUSH BUTTON FORWARD/REVERSE 220 V AC = 02 NOS |
| 31 | Supply and fixing in repair LED flood light 300 watt 230 V AC, outdoor type with toughened glass, high power LEDs, and secondary lenses with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant, MB/WB beam angles, 10KV SPD and system efficancy >-110/120/135 Lm/W complete with driver and lamp at High mast Pole 15/20 Mtr height including taking down old unserviceable fittings complete all as directed. cat part No : CFS-526-300-57-60D-HL2-LM-NGG |
| 32 | Supply and fixing in repair Aviation/engaged lightLED Red Obstruction Light (Steady + Flashing) — Top-mounted on High mast pole, IP66, UV resistant lens Low power LED beacon, 110–240 V AC or 24 V DC option; luminous intensity suitable for high-mast (16 to 22 meter hight pole) Built-in Flasher/Controller (if not integral to beacon) Programmable flash rate (e.g., 20–60 fpm) andsteady mode; mains compatible Top mounting bracket / pedestal for beacon (MS / SS) Hot-dip galvanized MS or SS304 bracket, suitable for pole top diameter Installation & commissioning (mounting at top, wiring, flash testing) Includes site lifting/hoisting chargesand submit Test Report andManufacturer datasheet, warranty card, test certificatecomplete all as directed. |
| 33 | Supply and fixingin repair loop in / loop out box of internal size 400 x 300 x 190mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 5/6 Amps MCB-01 No, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular pole using 25 x 3mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and as directed. |
| 34 | Supply, fixing , installed and testing of all in one integrated LED solar streetlight with pole 7-9 meter long Made In India consists of solar photovoltaic module, battery, control electronics, LED driver, inter-connecting cables and pole mounting piece integrated into the luminaire as a single unit. Luminaries: The luminaire shall have highly efficient mid power white dimmable LEDs Minimum 60 W with lumen output of Minimum 8500 Lumens, and a typical corelated color temperature of 5700K with CRI>70 and lenses with efficient optics designed for efficient light distribution for secondary roads The luminaire shall have a highly efficient, integrated microprocessor based MPPT charge controller with driver mounted on the same board to minimize power loss Dimming Profile should be for first one hour on motion at 100 % , without motion at 25 % , next 4 hours on motion 40 % & without motion 25 % . Next 6 hours 25 % Fix , rest of night on motion 40 % without motion 25 % The Solar Cell shall be made of Premium grade mono crystalline silicon Cell. The Solar Module Power shall be minimum 120 Wp at 18 Vmpp. for better uniformity of light. The Solar Module Construction shall be of Low iron All in one integrated LED solar streetlight Made In India consists of solar photovoltaic module, battery, control electronics, LED driver, inter-connecting cables and pole mounting piece integrated into the luminaire as a single unit. Luminaries: The luminaire shall have highly efficient mid power white dimmable LEDs Minimum 60 W with lumen output of Minimum 8500 Lumens, and a typical corelated color temperature of 5700K with CRI>70 and lenses with efficient optics designed for efficient light distribution for secondary roads The luminaire shall have a highly efficient, integrated microprocessor based MPPT charge controller with driver mounted on the same board to minimize power loss Dimming Profile should be for first one hour on motion at 100 % , without motion at 25 % , next 4 hours on motion 40 % & without motion 25 % . Next 6 hours 25 % Fix , rest of night on motion 40 % without motion 25 % The Solar Cell shall be made of Premium grade mono crystalline silicon Cell. The Solar Module Power shall be minimum 120 Wp at 18 Vmpp. for better uniformity of light. The Solar Module Construction shall be of Low irontempered glass with low reflection characteristics and with rated IP 65 The Battery shall be minimum 42 AH~ 12.8 VDC Rechargeable Lithium Ferro Phosphate (LiFePo4) Battery Pack. The Battery Pack should have Inbuilt Battery management system Module with following safety features The Successful bidder shall submit LM 79 & LM 80 of theFitting and LEDcomplete all as directed by EIC Make : BRP111LED85/757 =47WT 8500 LUMENPhilips/Crompton/WiproNote :- Excavation, MS work and PCC work shall be included in quoted rate |
| 35 | Material and labour in replacement/repair for earthing complete with UL listed CPRI Tested maintenance free copper bonded earth rod of 3.048 metres having diameter of 17.2mm with 254 micron copper coating with clamp made of stainless steel for terminating cable /flat conductor with Plastic pit chamber (PPGF) of outer dimension 290(L) x 290(W) x 209(H) withstand load of 60kN.buried directly in ground vertically to a depth below normal ground levelMeets the requirement for IS/IEC 62305 and IEC 62561-5 CAPE Type: EC 290 (Article No. 300 852). Earth enhancing mineral (PROCEN) compound ( electrical resistivity 0.018 ohm metre ) 25 kg tested for Leaching & TCLP with NABL accredited lab. The systems is conforming to IS 3043, IS / IEC 62305, IEC 61643-5-54, UL 467, the rod has to be tested to for dimension, marking, tensile strength, salt mist, coating thickness, electrical resistivity test before and after corrosion test etc as per IEC 62561-2.Chamber Inspection Pit made up of PP material can bear 60kN(6000KG) load. Set Consist of following BOM (1) Earth rod of 3 mtr length having the dia of 17.2 mm dia (CAPE Type No. CBR 1710 (Article No - 300 060) (2) CAPE Type: PROCEM 12.5 (Article: 300 790 ) , 12.5 Kg bag x 2 nos (3) : Universal SS Clamp SSUC 17( Article No 300580 ) (4) Earth Pit Chember 290(L) x 290(W) x 209(H) Fixing of Earth Chamber Inspection Pit made up of Plastic (PPGF) of outer dimension 290(L) x 290(W) x209(H) withstand load of 60kN. Meets the requirementfor IS/IEC 62305 and IEC 62561-5 CAPE Type: EC 290 (Article No. 300 852) including earth work,nut bolts complete all as specified and directed. Note :- Drillingboring /necessary excavation work andGI earth strip 32x6 mm and protection pipeup to 7.5 mtr shall be included in quoted rate |
| 36 | S&F for GI earthing strip 32x6 mm with nut and bolts complete including taking down old one allas specified and directed. |
| 37 | Supply and fixing in replacement Onload changeover switch AC-23 (side handle) in sheet enclosure 415 Volt , 50 Hz doublepole 100 Amp all as specified and directed by EIC. |