| 1 | Demolition of cement concrete un-reinforced Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 2 | Demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided for, complete all as specified and as directed. |
| 3 | Demolition of brickwork built in cement mortar with all quinces, arches, pillars etc., complete all as specified and as directed. |
| 4 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground posts embeded in concrete, brick work, masonry etc, complete all as specified and as directed. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 6 | Dismantling fencing wire mesh, any type, complete all as specified and as directed. |
| 7 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in Sub base finish the cement concrete surfaces, complete all as specified and directed. |
| 8 | M&L for Plain cement concrete 1:3:6 type C1(using 20mm graded crushed stone aggregate) as inSub base, footpath,finishing cement concrete surface and spike rolling to surfaces or making impression of expended metal,whilst the concrete is green, complete all as specified and directed. |
| 9 | M&L for 75 mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection finish the cement concrete surfaces, complete all as specified and directed. |
| 10 | M&L for cement concrete type C2 1:3:6 (40mm graded crushed store aggregate) as in foundations filling & mass concrete, complete all as specified and as directed. |
| 11 | M&L for forming contraction (dummy) joint 65mm deep X 10mm wide filled with sealing compoung Grade \"A\", complete all as specified and directed. |
| 12 | M & L for oldsizebrick work with sub class B bricks straight or curved on planexc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed. |
| 13 | M&L for PCC type B-0 (using 12.5 m graded crushed stone aggregate) as in coping etc, complete all as specified and as directed. |
| 14 | Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 15 | M&L for rendering 15 mm thick plaster in CM (1:4) on brick or concrete surface mixed with water proofing compound as per manufacturer instruction finished all as directed (only WPC shall bemeasured and paid separately), complete all as specified and as directed. |
| 16 | M & Lfor preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of alkali resistant priming paint, complete all as specified and as directed. |
| 17 | Material & labour for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete drilled for fixing of steel sheeting or other covering, Doors etc to be prepared for hanging or sliding with and including either hookes and hinges or steel hanging doors fittings (exclusive of steel Steel covering running rails and guides) and hanging also fastening and fixing including pintels, complete all as specified and as directed. |
| 18 | M & L for Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 19 | S&F of galvanised two strand barbed wire, 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with provision of galvanised mild steel wire stapples or steel pins,complete all as specified and directed. |
| 20 | All as item No 19.00 above but fixed in repairs including restraining & resecuring including making good staples etc,complete all as specified and directed. |
| 21 | Supply only Chain link MS Galavanised fencing any size or type, complete all as specified and directed by Engr-in-Charge. |
| 22 | M&L for fixing olnly chain link fencing including line wires, any mesh, size and type to any type of standards rails, straining bolts, etc including provision of binding wire,complete all as specified and directed. |
| 23 | S&F of concertaina coil 600mm dia (in streached position) hot dip galvanized steel wire coated with CLR anti corrosive paint making diamond shape with the help of dovetail clips (26 SWG) fixed over and including razaror wire ,medium barb , hot dip galvanized steel wire with angle iron fixing to Y-shaped iron post on top of boundary wall, complete all as specified and as directed. |
| 24 | S&F of concertaina coil 900mm dia (in streached position) hot dip galvanized steel wire coated with CLR anti corrosive paint making diamond shape with the help of dovetail clips (26 SWG) fixed over and including razaror wire ,medium barb , hot dip galvanized steel wire with angle iron fixing to Y -shaped iron post on top of boundary wall, complete all as specified and as directed. |
| 25 | M&L for angle iron / flatiron for fixing chain link or hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and clountersunk for balusters running bars, for doors, balusters, nosing to steps including embneding in concrete and screwing etc wid ties for roof including securing bolts, posts and struts in fencing including cutting tops shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or reveting etc, and similar work conforming to Fe-290 or Fe-165, complete all as specified and directed. |
| 26 | M&L for prepration of newsteel surfaces andapplying two coats of synthetic enamel paint over a coat of red oxide on new steel surfaces of any description over 10cm width or girth, complete all as specified and directed. |
| 27 | M & L for Roof trusses (framed) trussesd purlins,tublar section , crane gantries , rails and fastening and heavy bracket framing (beam , channel, tee,angle or flat section ) including distance pieces, brackets etc complete all as specified and directed. complete Fe-410- W(GdeE-250) quality, complete all as specified and as directed. |
| 28 | S&F of mild screw bolts 11 to 15 mm diameter of neck shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to fitted with washers and one hexagonal or square exc. 5cm but n.exc 10cm long, complete all as specified and as directed. |
| 29 | Material and labour for RCC 1:2:4 type B1, using 20mm graded crushed stone aggregates as in Reinforced cement concrete for drain cover,cover slab etc andset in cement morter, complete all as specified and as directed. |
| 30 | Supply and fixing of TMT bars10 mm dia and over.as in reinforcement cut to length, bent to shape required including cranking, bending and binding with mild steel wire not less than 0.9 mm dia, complete all as specified and as directed. |
| 31 | Dismantling Asbestos Cement/CGI (Corrugated, Semi corrugated etc.) sheets in roof coverings, complete all as specified and as directed. |
| 32 | S&F of Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping crews, complete all as specified and as directed. |
| 33 | M & L for replacing/renewing cement concrete tiles in patches, area n exc 5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles, complete all as specified and as directed. |
| 34 | M&L for Sand filling under floors or in foundations including watering and consolidation, complete all as specified and as directed. |
| 35 | M&L for chequered cement concrete tiles (coloured) 30cmX30cmX20-25mm thick, set and jointed and pointed in neat cement slurry with grey cement and pigment in floors, complete all as specified and as directed. |
| 36 | M&L for Machine pressed precast concrete interlocking paver block(Coloured) any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment, complete all as specified and as directed. |
| 37 | M&L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges of cement concrete type B0 1:2:4 using 12.5 mm stone aggregate, complete all as specified and directed. |
| 38 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material |