| 1 | M&L for carrying out B check including periodic maintenance & servicing prescribed by the manufacturer of the DG Set from authorized rep of service engineer from the manufacturer of the DG Set of Greaves/Cummins/Kirloskar 40 to 200 KVA capacity installed at R-29 Bldg, Near Tula Bldg, R-12 Bldg, Mithun Bldg, Mulla Auditorium, R28 Pump House, Substation No. 7, R41 Bldg, Substation No. 8 & Trolley (Total 13 Nos.) including replacement of engine oil, coolant and replacement of following unserviceable spares complete all as specified and directed by EIC.Note: Spares will be measured & paid separately under respective items here in after. |
| 2 | Supply only in replacement Diesel fitter as per existing make and model. |
| 3 | Supply only in replacement Lub oil filter as per existing make and model.. |
| 4 | Supply only in replacement Air filter element as per existing make and model. |
| 5 | Supply only in replacement Fan belt as per existing make and model. |
| 6 | Supply only in replacement Carbon bush as per existing make and model. |
| 7 | Supply only in replacement high pressure oil pipe as per existing make and model. |
| 8 | Supply only in replacement Lub oil pipe as per existing make and model. |
| 9 | Supply only in replacement Radiator hose pipe set as per existing make and model. |
| 10 | Supply only in replacement LLOP Sensor as per existing make and model. |
| 11 | Supply only in replacement of coupling flanged type as per existing make and model. |
| 12 | Preventive maintenance and servicing of DG sets 40 to 200 KVA capacities installed at R-29 Bldg, Near Tula Bldg, R-12 Bldg, Mithun Bldg, Mulla Auditorium, R28 Pump House, Substation No. 7, R41 Bldg, Substation No. 8 & Trolley (Total 13 Nos.) at Navy Nagar complete all as directed the preventive maint shall be carried out weekly basis. The weekly maint shall be carried out as under:(i) Cleaning of DG set floor and area (ii) Checking levels of Fuel/Engine Oil/Coolant and top-up the level if required (iii) Checking of Batteries, flexible coupling, injectors, thermostats, monitoring functions, compression, turbo charger clearance of bearings, air and water hoses, Zinc protective pipes, coupling disc of fuel pump drive, \"V\" Belts (iv) Checking tightening of all nuts and bolts. (v) Checking levels of distilled water in batteries and top-up the level if required. (vi) Checking levels of distilled water in batteries and top-up the level if required. (vii) Cleaning of air filters (viii) Lubricating/Greasing to moving parts (ix) Checking and reset valve clearances. (x) Checking and setting of speed Governor and engine shut down for proper functioning (xi) Checking of carbon bushes of generator and lubricate the bearings (xii) Cleaning of Crankcase ventilation, cooling water spaces, inter cooler (xiii) Checking of replacing carbon bushes and starter pinion (xiv) Checking and monitoring of DG set running in condition by switching on mannual position on without load not less than 15 minute in week for each DG set and maintaining their running record in Log sheet/PRRB. If any shortcomings found in any DG set, immediately rerport to JE concern as well as to the contractor. Schedule of running for each DG set shall be decided by the Engr-in-Charge. Weekly Preventive maintenance and servicing of 13 Nos DG Sets shall be measured as a one Job. Note : -(a) Spare parts shall be measured and paid separately. (b) Oil, Coolant and distril water will be measured and paid saparately. (c) Complaint pertains to DG Set of the sch A as given by Engr-in-Charge at any time shall be attend within 12 Hour from the time of complaint assined to the representative of the firm as directed by Engr-in-Charge up to the satisfactory level and on failing which the penalty shall be imposed 2500 per day per item / complaint of schedule \"A\". |
| 13 | M & L for replacement of old engine oil from the sump of DG Setsinstalled at various locations after cleaning the oil sump throughly supply & filling new Lub oil, SAE 15W40 grade complete all as specified & directed by Engineer-In-Charge.Make : Servo super of Indian Oil or Equilent grade of Hindustan Petrolium. |
| 14 | S&F in replacement ofFuel Pre Filter Suitable for Diesel Engine, TBD 3V 6MK-1/TBD 2V6/TBD 2V 6MK-1/TDL4L. Make : Greaves Ltd.and all as specified and directed by Engineer-In-Charge.Male/Botch/Greaves |
| 15 | M & L for topping up of water coolent in radiator of DG sets tinstalled at variouslocations complete all as specified & directed.Make : TVS Girling/volvo line or of equivelent make all as approved & directed by EIC. |
| 16 | M & L for dismantaling of FIP for ovarhaulling and caliberation in authorised workshop including replacement of wornout rings plungers, damper plate, gaskit etc and reassembling testing complete for DG sets of capacity 40 KVA to 140 KVAcomplete all as specified & directed. |
| 17 | All as per Item No 6.00 above but DG sets capacity 160 KVA to 200 KVA |
| 18 | M & L for repair overhalling of self starter including replacement of worn out clutch assembly bush, spring, plunger assembly, solenoid switch, corbon brushs, spring etc for DG sets of capacity 40 KVA to 140 KVAcomplete all as specified & directed. |
| 19 | All as per Item No 8.00 above but DG sets capacity 160 KVA to 200 KVA |
| 20 | Repair/overhaling of dynamo/charging alternator including replacement carbon, brushes holder, spring commutator/slipring assembly bearing regulator its of any make, type and capacity, complete all as directed. |
| 21 | Cleaning of the fuel tank of DG sets of of capacity 40 KVA to 140 KVA after decaning the diesel, after throughly cleaning with kerosene oil including replacement of level indicator pipe complete all as directed by EIC. |
| 22 | All as per Item No 11.00 above but DG sets capacity 160 KVA to 200 KVA |
| 23 | M & L for dismantling and removing of water pump assessmbly complete from the engine repair/overhaulling the same by replacing worn components like bearing, impeller, bushes, oil seal, water seal, gaskit etc. reassembling, refixing and testing complete for DG sets of capacity 40 KVA to 140 KVAcomplete all as specified & directed. |
| 24 | All as per Item No 13.00 above but DG sets capacity 160 KVA to 200 KVA |
| 25 | M & L for Automatic voltage regulator suitable for DG set of capacity 40 KVA to 140 KVA as per existing Make & model and as directed by EIC. |
| 26 | All as per Item No 15.00 above but DG sets capacity 160 KVA to 200 KVA |
| 27 | M & L for replacement of fuel shutdown valve assembly complete testing including replacement of old unsv valves of any capacity DG set, complete all as directed by EIC . |
| 28 | M & L for replacement of bendix drive pinon assembly of self starter of capacity 40 KVA to 200 KVA DG set complete all as specified & directed . |
| 29 | M & L for replacement of existing make and model fly wheel ring including heating for press fitting for engine of DG sets of capacity 40 KVA to 140 KVAcomplete all as specified & directed. |
| 30 | All as per Item No 19.00 above but DG sets capacity 160 KVA to 200 KVA |
| 31 | M & L for replacement of stop solonoid assembly for DG sets of capacity 40 KVA to 140 KVAcomplete all as specified & directed. |
| 32 | All as per Item No 21.00 above but DG sets capacity 160 KVA to 200 KVA |
| 33 | M & L for Dismantling of radiator of DG set of capacity 40 KVA to 140 KVA and transporting to work shop for servicing/cleaning after dismantling twin tanks, replacement of gasket packing, nuts, bolts, washers, descaling with appropriate chemical and elding of copper brazing of damazed fins/tubes and reassembling & refixing in same position after testing complete all as specified & directed. |
| 34 | All as per Item No 23.00 above but DG sets capacity 160 KVA to 200 KVA |
| 35 | S&F Tachometer/speedometer incl dismantling the existing meter suitable for kirloskar and cummins Engine all as directed. |
| 36 | Supply only ammeter 0 to 300 Amp range 96 x 96 mm flush type 3 Phase 415 Volts AC with CTs Ratio 100/5 A in all Three phases with 4P selector switch to read current in all three phases including dismantling old ammeter. |
| 37 | Supply only Voltmeter 0 to 500 Volts AC including dismantling old voltmeter with 4P selector switch to read 3 Phase voltage. |
| 38 | M&L for scraping the peeled oil Paint on 40 to 200 KVA DG set including alternator,Engine and Fuel tank,sound proof cover Preparing the surfaces, cleaning the dust, dirt and applying two coats of synthetic enamel paint of approved shade and writing SM No on the DG set and all as directed by Engineer-In-charge. |
| 39 | M & L for repairing of complete GENSET engine wiring including extesion of existing PVC insulated , stranderd copper conductor wire of size 2.5 sq mm /1.5 sq mm for control/ signal circuit complete with & including flexible conduit, copper lugs, PVC ties, fasteners & synchronisation and calliberation of AMF panel with engine control panel complete all as specified & directed . |
| 40 | M & L for General servicing/repair of AMF panel including cleaning, resetting/adjustment of relays of timer relay,overload relay, auto start/stop relay its checking and replacement if required wire,diodes resistor etccomplete for existing make and capacity |
| 41 | M & L for replacement of SMPS based Electronic Battery Charger suitable for 12 / 24 Volts battery charging system complete all as specified & directed. |
| 42 | M & L for replacement of contactor 4 pole, not less than 300 Amp, 415 Volt with integrated auxiliary contacts : 2 NO + 2 NC conforming to IS / IEC 60947-4-1 and compitable with existing AMF panel complete all as specified and directed. |
| 43 | M & L for replacement of contactor 4 pole, not less than 250 Amp, 415 Volt with integrated auxiliary contacts : 2 NO + 2 NC conforming to IS / IEC 60947-4-1 and compitable with existing AMF panel complete all as specified and directed. |
| 44 | M & L for replacement of contactor 4 pole, not less than 200 Amp, 415 Volt with integrated auxiliary contacts : 2 NO + 2 NC conforming to IS / IEC 60947-4-1 and compitable with existing AMF panel complete all as specified and directed. |
| 45 | M & L for replacement of spare coil for existing contactor fitted in AMF panel of any capacity & type complete all as specified. |
| 46 | M & L for replacement of engine start relay 12/24 Volts compitable with existing AMF panel complete all as specified. |
| 47 | M & L for replacement of over and under voltage relay 3 phase 415 Volts compitable with existing AMF panel complete all as specified. |
| 48 | M & L for replacement of Auxiliary relay 8 pin /11 pin compitable with existing AMF panel complete all as specified. |
| 49 | M & L for replacement of timer switch AC/DC compitable with existing AMF panel complete all as specified. |
| 50 | S&F in replacement with newExhaust silencer suitable for Diesel Engine,Model No.TBD 3V 6MK-1/Model No.TBD 2V6/ Model No.TDL4LModel No.TBD 2V 6MK-1. Make : Greaves Ltd.and all as specified and directed by Engineer-In-Charge. |
| 51 | M & L for replacement of ON Load change over switch 4 Pole, 415 Volt, in sheet steel enclosure of capacity 200 Amps complete all as specified & directed. |
| 52 | Supply and fixing in replacement of Asbestos Rope DG Rating 40KVA to 200KVAand all as specified and directed. |
| 53 | M & L for replacement of battery terminals brass with steel nuts, bolts & washers and all as directed. |
| 54 | M & L for replacement of battery lead stranded copper conductor of size 50 Sq mm and all as directed. |
| 55 | M&L for filling / pouring distill water packed in 20 / 25/ 35 litre PVC containers & top up of electrolite for servicing of battery complete all as specified & directed . |
| 56 | Supply and installation of maintenance free battery lead acid type of capacity 12 Volt 180 AHforDG Setsinstalled at various locations Complete all as specified & directed by Engineer-in-charge. |
| 57 | Taking down old existing unserviceable AMF panel of DG set and supply, install, testing and commissioning ofnew AMF panel for DG Set of Capacity 40 to 250 KVA3 phase, 4 wire, 415 volts, with copper busbar strip of suitable capacity with necessary clamps, nuts, bolts and washers, floor mounted type and made with angle iron 40x40x5 mm thick, legs of size not less than 0.60 Mtr Long from floor level and painted with two coats of red oxide primerincl foundation in PCC including multi function meter with LED display with CT\"s, LED indicator lamp all as specified & directed.Note : All existing cable connections will be disconnected from old panel carefully and re-connected with new panel by providing glands and thimble all as directed by Engineer-in-Charge. |
| 58 | M & L for 80 mmdia M S Pipes heavy grade for fixed on ground/floors to used as post/structure for shed including fabrication work like welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 59 | Same as Item No 48.00 above but 40 mm diaM S Pipes heavy grade. |
| 60 | M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 61 | M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 62 | Supply, Fixing, testing and commissioningofXLPE insulated armoured, heavy duty electric cable with aluminium conductorlaid in trenches, fixed on wall, passing through pipes complete including connecting with MCCB/ busbar with the help of proper size thimble, glands,properly as directed by engineer-in-charge and taking out existing damaged unserviceable cable of following sizes:- Note : Excavation, earthwork and cable protection shall be measured and paid separately under relevant items. |
| 63 | 300 Sq mm, 3.5 core |
| 64 | 185 Sq mm, 3.5 core |
| 65 | 120 Sq mm, 3.5 core |
| 66 | 95 Sq mm, 3.5 core |
| 67 | 70 Sq mm, 3.5 core |
| 68 | 35 Sq mm, 3.5 core |
| 69 | 25 Sq mm, 3.5 core |
| 70 | 16 Sq mm, 4 core |
| 71 | Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables . |
| 72 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils. |
| 73 | Removing excavated material from the site of work to outside MD land complete all as specified. |
| 74 | Cutting existing road surface or hard standing, bituminous topping etc depthupto 50 cm but n exc 45cm width for laying of pipes/ cables complete. |
| 75 | M&L for making good of road cutting upto 450 mm wide, clean the cutting surfaces and filling hard core and match the existing bitumen surfacethickness of road with premix bitumenus material ready to use complete all sa specified and directed by Engr-in-charge. |
| 76 | M&L for GI pipe ,light grade 50mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed. |
| 77 | M&L for GI pipe ,light grade 80mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed. |
| 78 | M&L for GI pipe, light grade 100mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed. |
| 79 | M & L for fixing of old interlocking paver tiles/blocks of any sizes recovered form item SI. No. 53 complete as specified and directed. |
| 80 | M & L for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of existing size and existing type complete as specified and directed. |
| 81 | Material and labour for layer of 50 mm thick natural river sand bedunder floors or in foundation or under paver blocks including watering and consolidation complete as specified and directed. |
| 82 | M&L for High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 40mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed. |
| 83 | M&L for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 75mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed. |
| 84 | M&L for High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 100/110mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed. |
| 85 | Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) after taking out old, U/S one complete all as directed by Engineer-in-Charge. |
| 86 | M&L for taking out existing Panel andshifting of LT panel of any sizewith all accessories and fixing it to other location as directed by Engr-in-Charge at site, connecting cable connection with connecting accessories, incl foundation in PCC 1:3:6 type C2 all as specified and directed. |
| 87 | Material & Labourfor repairs/Servicing to indoor/outdoor type existingLT electric feeder panels / meter panels or AMF panel including checking loose connections and tight connection and cleaning inside/out side all connection,replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge all as directed and specified.Note :- (i) The tenders quoted rate per unit shall deemed to be inclusive of taking out & replacement of petty items like nuts, bolts, vision glasses, glands, thimbles, lugs, earthing lead etc. (ii) The tenders quoted rate per unit shall deemed to be inclusive of taking out & replacement of burntMCB SPN/MCCB/Voltmeter/ Ammeter/LED lamps of any type and discription etc and refixing the same, which shall be measured and paid as supply only vide relivent items of this schedule. |
| 88 | Cleaning inside the panel and all incoming and out going feedersi.eincludinging MCCB/Changeover switches/Contactors thorouly with help of Vaccum Cleaner. |
| 89 | Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers |
| 90 | Replacing the burnt out color coated PVC Sleeve of main and fedders bus bar with appropriated size of New PVC heat shrinkable sleeves |
| 91 | Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/HRC Fuses.(Note: New items shall be measured and paid separatly) |
| 92 | Replacing burnt out control wiring of Ammeter/Voltmeter/Indicating lamps and CT\"swith 2.5/1.5Sqmm copper single core,1100V grade copper conductor cable |
| 93 | Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size of new bus bar ( Note : Bus Bar will measured and paid separately). |
| 94 | Spray Painting of Panel Board with one coat of synthetic enamel paint. |
| 95 | S&F Copper Bus Bar stips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed.Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs.(b) Overall length of the strip shall be measured and paid after necessary conversion into weight.(c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account.(d) Rate of Bolts, Nuts etc shall be included in quoted rate. |
| 96 | S&F of suitable type and size FRP / DMC bus bar support insulator (Bridge Insulator) for fixing the extended aluminium/copper bars, for cable terminations, duly fixed in the body of the panel boardincluding galvanized steel bolts, nuts, washers etc.and necessary drillings, in the panel body,complete all as specified and as directed. |
| 97 | Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge. |
| 98 | Supply and fix cable jointing kitStraight Through Jointfor 1.1KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3.5core XLPE armoured, alluminum conductor cable of size 25 to 95 sq mm after taking out and cutting the faulty cable area, inserting 1 mtr Cable of existing size for jointing Cables if required at site and all as directed by Engineer-In-Charge. |
| 99 | All as per Item No 73.00 above but for 3.5core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm and all as directed by Engineer-In-Charge. |
| 100 | All as per Item No 73.00 above but for 3.5core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge. |
| 101 | Supply only, MCCBsthermal magnetic release,lcs=100% lcu in existing FP/panel, connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary), connection complete and testting after complition, all as specified and directed,of following capacities :- |
| 102 | MCCB 63/100 Amps,16 kA, TP, 50 Hz. |
| 103 | MCCB 160 Amps, 25 kA, FP, 50 Hz. |
| 104 | MCCB 200 Amps, 25 kA, FP, 50 Hz. |
| 105 | MCCB 250 Amps, 36 kA, FP, 50 Hz. |
| 106 | MCCB 400 Amps, 36 kA, FP, 50 Hz. |
| 107 | MCCB 630 Amps, 36 kA, FP, 50 Hz. |
| 108 | Supply and fix in replacement with radiator having copper fins for DG set of capacity 100 KVA to 140 KVA of existing make and existing model including taking out old onecomplete all as specified and directed by Engr-in-Charge |
| 109 | All as per Item No 77.00 above but DG sets capacity 160 KVA to 200 KVA |
| 110 | Taking down the existing RECD & silencer system, suitable modification to the canopy for installation of Retrofit Emission Control Device, Supply, Fixing, testing and commissioning suitable Retro Fitment for Emission Control Device in Diesel Generator of capacity 40 KVA/ 32 KW. The Retrofit Emission Control Device must have approved CPCB-I/ CPCB-II for family of DG sets. • DG safety Alarm system included• Material Construction - SS304• Temperature Indication and monitoring• Pressure Indication and monitoring• PM Capture/PM reduction capacity 85-90%• High Heat Resistance• Low exhaust Resistance• Easy to Install• Maintenance twice a yearly with back purge for One year.* Durability period should be 4000 hrs or 12 years whichever is earlierMake/ Manufacturer : Automoto Genset Solutions LLP/ Inventive Gas Equipment orPI Green Innovations Pvt. Ltd.Note :-(i)Approval: Device Should be type Approved(CPCB-I & CPCB-II) for family of DG sets should be as per CPCB instructionsand same has to be obtained from one of the five currently Central Pollution Control Board.(ii)Application: Device capable to reduce particular matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from the Diesel Engine Technology/Type: ESP (Electro Static Precipitator), Wet Scrubbing,Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency(Min) Guaranteed specified Particulate matter (PM 2.5). |
| 111 | (iii)Carbon Monoxide, Hydrocarbon reduction efficiency Retrofit device is to be installed in place of the existing silencer, soot is to be collected in the Retrofit Device.(iv)The device including enclosure should include an Oxidation chamber and PassiveRegeneration Trap. A manual valvebe given after the first stage ( Oxidation stage) and before the second stage (Passive Regeneration Trap) of the DOFF, Noise attenuation is with in the permissible limits, Equipped withmechanical pressure relief system, capturing chamber made ofresistance process, treated mild steel etc. as required.(v) The RECD device provided by the seller should be equipped with a remote Data Monitoring system certified byICAT/ARAI providing essential information recorded at every 15 minutes, including but not limited to :a. Energy consumption.b. Running Hours.c.warning related to ECD diagnosis for the following conditions:* Coplete loss of particulatecapture function.* Removal of the ECD system.* Failure of ECD system.* Detection of exhaust bypass, temporary or permanent, as part of field/operator tampering.(vi) Scope of Installation:-a.Installation of Emission contrrol Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation workof Emission Control Retrofit Device includes any type of mechining, Tools & Plants and materials required. b. Construction of suitable earthing station(if applicable) and necessary connections shall be done by the seller. Warranty/Service : 12 Months number of preventive maintenancevisits offered in a year during warranty period :-2 visits(vii)The Device to be minimum 10-12 year guarantee from date of commissioning. The guarantee certificate to be submitted to Engr-in-charge after commissioning the equipments. |
| 112 | (viii) The contractor shall submit work / methodology details, Drawings for approval of GE.(ix) Factory visit of device by Engineer in charge for approval is required before installation which is to be catered by contractor. |
| 113 | Supply and fix in replacement with Micro-processor based generator set monitoring and control system including an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration and diagnostics, LED backlit LCD display with tactile feel soft-switches & generator set status LED lamps, remote START-STOP suitable for DG set of capacity 40 KVA to 140 KVA of existing make and existing model including taking out old onecomplete all as specified and directed by Engr-in-Charge |
| 114 | All as per Item No 80.00 above but DG sets capacity 160 KVA to 200 KVA |
| 115 | Taking out Old U/S and S&F MCB SPN, 32 Amp, 10 KA, 230 Volt. |
| 116 | Supply & fix in repairsindicatinglamp holder with bulbLED (Red, Yellow, Blue, Green) type toindicateincoming supply suitable for 24 V DC/110 VAC/230Volts AC andall as specified and directed.Make:Teknic/ C&S/L&T/Kaycee |