|
| 1 | DESCRIPTION OF ITEMS |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for foundation etc and getting out inhard/dence soil complete all as specified and as directed. |
| 3 | Surface excavation n exc 30cm deep and averaging 15cm deep and getting out inhard/dencesoil complete all as specified and as directed. |
| 4 | Returning filling including spreading, levelling, watering and well ramming in layers n exc. 25cm (hard/dense soil) |
| 5 | Filling under floor (except material) including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified. |
| 6 | Removal of excavated soiln n.exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed |
| 7 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed. |
| 8 | M&L for RCC M 25 (Nominal Mix) as in foundation, including raft, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and as directed. |
| 9 | M&Lfor RCCM 25 (Nominal Mix) as in columns, pillars, piers etc complete all as specified and as directed. |
| 10 | M&Lfor RCC M 25 (Nominal Mix) as in beams, cantilever, lintels etc complete all as specified and as directed. |
| 11 | M&Lfor RCC M 25 (Nominal Mix) as in Shelves etc complete all as specified and as directed. |
| 12 | M&Lfor form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, plinth beams or similar works vertical or to batter for rough finished surface of concrete complete all as specified and as directed. |
| 13 | M&Lforform work to sides of pillars, posts, struts, columns for rough finished surface of concrete complete all as specified and as directed. |
| 14 | M&Lfor form work to sides and soffits of roof beams, lintels lever shelves incl supports over hang etc ruogh finished surfaces of concrete flat complete all as specified and as directed. |
| 15 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to complete all as specified and as directed. |
| 16 | Description same as above Item No 14 but, 5 mm dia and over and incl 10mm dia in stirrups, spacers and binders |
| 17 | M&L for precast cement concrete Block Masonary with soilid blocks type C1 1:3:620mm graded stone aggregate exc 10cm in width and setting in mortar 1:6 complete all as specified and directed . |
| 18 | M&L for precast cement concrete Block Masonary with soilid blocks type C1 1:3:620mm graded stone aggregate n.exc 10cm in width and setting in mortar 1:4 complete all as specified and directed . |
| 19 | Cutting chases in brick wall, stone, concrete block or slab walls, pining in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings ,steps,cills sunshades, shelves , lintels, etc and cutting chases for concealed water tubing and making good , cutting n\"exc 10 cm girthcomplete all as specified and directed. |
| 20 | M & L for 15 mm thick cement plaster with water proofing compoundon fair faces of brick work or concrete surface on wall in CM 1:4finished even and smooth (without using extra cement) complete all as specified and directed. (Water proofing compound measured separately) |
| 21 | M & L 15 mm thick cement plasterwith water proofing compound on fair faces of brick work or concrete surface on wall in CM 1:6finished fair and even complete all as specified and directed.(Water proofing compound measured separately) |
| 22 | Supply only water proofing compound, complete all as specified and directed. |
| 23 | M&L for hard core of broken stone or boulders gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface of broken bricks aggregate complete all as specified and directed. |
| 24 | M&L for 75mm thick PCC 1:3:6of type C-2 using 40mm graded stone agrregate as in sub baseas in floor th etc complete all as specified and directed. |
| 25 | M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as Cement concrete in surface channels and drainscomplete all as specified and as directed. |
| 26 | S&F of chequered tiles 20X20X25cm thickset, jointed and pointed in neat cement slurry with grey cement and pigments in floor incl 15 mm thick screed bed with cm 1:6 complete all as specified and directed. |
| 27 | M&L forextra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tracement, including forms, moulds, mi- tred/stopped ends etc. |
| 28 | S&F for non-skid joint free ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.11 Sqm but n exc 0.18 sqm set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floor over and including 15mm thick screed bed in CM 1:4 mixed with water proofing compound complete all as specified and as directed .(Water proofing compound measured separately) |
| 29 | M & L forglazed joint freeceramic coloured tiles 350x250x6 to 7mm / 450 x 300 x 6 to 7 mm thick on walls etc set & jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces over &.incl 10mm thick rendering in cement mortar 1:4 for laying wall tiles etc complete all as specified and directed. |
| 30 | S&F of factory made solid PVC door frames of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening as per specification & drawing |
| 31 | S&F of factory made solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of M S tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain coloured PCV ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cementsuppling & fixing in the frame at site as per specification & drawings. |
| 32 | S & F Butt hinges 100mm, extruded aluminium alloy with galvanized mild steel hinge pin, anodised of type B-22 and complete all as specified and as directed. |
| 33 | S&F 200mm aluminium anodised barrel tower bolts of extruded section all as specified |
| 34 | S& F 150 mm extruded aluminum alloy handles, fabricated type anodised. |
| 35 | S&F of 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 36 | S & F M.S. Framed work such as grills grating etc. with ends of bars sholdered and / or riveted into spikes, framed guard bars / railingscomplete all as specifiedall and directed. |
| 37 | S & F steel ventilators with tophung shutters incl.hinges, steel handle and steel peg stay complete with glazing sash, dovetailed or weldedcomplete all as specifiedall and directed. |
| 38 | S & F of rough cast wired glass of 6.40 mm thick quality and glazing with oil putty in square nexc. 0.5 sqm in each pane complete all as specifiedall and directed. |
| 39 | S & F of Rooftrusses Fe 410 -W (GdeE- 250) qualityA(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified all and directed. |
| 40 | S & F of Pre- painted galvatume aluminum zinc coating GI based corrugated roof steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 41 | S & F of Anodised aluminium snap grid frame work for false ceiling all as specified |
| 42 | S & F of12 mm thick Perforated particle board/ tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid in slop/ceiling |
| 43 | M&L three coats of white wash on walls including preparation of new plastered surface and complete all as specified. |
| 44 | M&L for Preparation of new (Previously untreated) plasteredsurfaces of walls and applying two coats of cement based paint over one coat primer on walls,complete all as specified and directed |
| 45 | M & L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed . |
| 46 | M&L for 18 mm to 25 mm thick black marble stone slab toping table rubbed and mirrorpolished over 15 mm thick screed bed or bedding layer ( 1:4) and jointed with white cement slurry mixed pigment to match the colour incl rounded / halfrounded edge as in steps, jambs, pillars, window-cills, partation wall etc complete all as specified and directed. |
| 47 | S&F of 15mm bore medium grade galvanised steel tubing with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed. |
| 48 | S&F of 20mm bore medium grade galvanised steel tubing with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed. |
| 49 | S&F of 20 mm bore Gate valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed complete all as specified and directed. |
| 50 | S&F of 15 mm bore dia Angle stop valves of CP any colour screwed down , high pressure , with capston head, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 51 | S&F of 15 mm bore conceled type stop cock of CP colour screwed down , high pressure , with capston head, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 52 | S&F of 15mm bore dia Bib taps chromium plated with capston head, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed . |
| 53 | S&F of under / over Oval type wash basion supperior colour 550X400 mm fitted with granite top over pre cast rcc slab incl waste coupling 150 mm long & suitable bottel trapetc complete all as specified and directed. |
| 54 | S&F of 15 mm bore pillar cock of CP colour screwed down , high pressure , with capston head, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 55 | S&F of 450mm long PVC Connection 15mm size with brass nutscomplete all as specified and directed. |
| 56 | S&F of600x450 mm bevelled edge of slected quality glass mounted on 6 mm thick AC building boardor commercial plywood and fixed to PVC plug with chromium plated brass screws and cup washers complete all as specified and directed. |
| 57 | S&F of Brass chromium plated Tubular towel rail , 20mm dia, D type , 60cm long between falnges complete all as specified and directed. |
| 58 | S&F of vitreous China squatting pan,‘Orissa’ pattern, size 580 x 440 mm white, with integral foot restscomplete includingprovision of cement concrete bedding (excluding flushing cistern and flush pipe)complete all as specified and directed. |
| 59 | S&F of 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets,flushing pipe etc complete all as specified and directed. |
| 60 | S&F of Shower with shower arm 15 mm size, 195mm long with bend of 45degree with flange of brassany colour.(Minimum weight 40gms complete all as specified and directed. |
| 61 | S&F of mild steel pegs set of 6, solid body, 175mm to 250mm etccomplete all as specified and directed. |
| 62 | S&F for Vitreous China Urinal, Half stall type, white fitted on wall incl spreader of brass, PVC waste pipe complete all as specified and directed |
| 63 | S&F of PVC (SWR) floor trap with CP grating including jointing to waste pipe 75 mm bore outlet with solvent cement all as specified. |
| 64 | S&F of75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed laid in trenches or in floors etccomplete all as specified and directed. |
| 65 | S&F of 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors etccomplete all as specified and directed. |
| 66 | S&F 110mm bore PVC (SWR) junction single (Single T) equal or unequal |
| 67 | S&F of PVC (SWR) bends 110 mm bore with or without oval excess door complete all asspecified and as directed |
| 68 | Construction of septic tank In any type of soil/Rock for 50 users PCC block massonary wall ,PCC in foundation 1:4:8 ,floor ,cover slab incld sludge chamber, CI vent,pipe, CI cowl inlet and outlet pipe,RCC baffle wall and all necessary earth work complete all as specified and directed. Ref TD No CEBZ TD-217 SHEET 1/7 TO 7/7. |
| 69 | Construction of soakage well In any type of soil/Rockof size 1.2 MX3.00 M effective depth excavation in any type of soil foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M-25 cocntrete includg intrcepting chamber and screen chamber made of brick masonary in cm,RCC cover slab in M-25/SFC cover,interconnecting pipes of RW/DWC complete filled with brick batsall necessary earth work complete all as specified and directed.Ref TD No CEBZTD-309 SHEET 1/4 TO 4/4. |
| 70 | M & L for Cement Concrete Type B-2, 1:3:6 (40mm graded aggregate) as in foundation filling and mass concrete etc complete all as specified and as specified. |
| 71 | Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil complete |
| 72 | M&L for Broken stone or boulders Harcore of gauge exc 63mm but n exc 100 mm,deposited,spread and levelled in layers n exc 15 cm thick watered and rolled/rammed to a true surface |
| 73 | M&L for moorum /red bajiri filling in floors n exc 15 cm thick spread and levelled in layers n exc 15 cm thick watered and rolled/rammed to a true surface |
| 74 | M&L for PCC 100 mm thick 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in sub base of floors, footings etc, complete all as specified and directed. |
| 75 | M&L for40 mmthick PCC 1:2:4type B-0 using 12.50 mm graded stone aggregate as infloors etc, finished rough to receive floor finishes complete all as specified and directed. |
| 76 | M&L for machine cut kota stone slab flooring 18-20mm thick over20mm thickcement screed bed in 1:6 CM laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completeall as specified and directed. |
| 77 | S&F for steel work as in tubular truss incl special shaped washer etc complete using erw or induction butt weld ed tubes confirming to IS |
| 78 | S & F mild steel Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates all as spd and directed |
| 79 | M & L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. |
| 80 | M & L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. |
| 81 | Material & labour point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, FRLS ,multi stranded, Fire Retardant conforming to IS 694-1990 PVC insulated, unsheathed copper conductor cable FRLS in and including PVC concealed conduit/casing caping/modular fittingof 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, with modular sunken box along with cover plate inner and outer both of required module including all cutting/chases etc in walls, making good towalls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbedsurfaces to match the existing with concealed in wall with and including continuousearth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for light point/ fan point controlled by one, one way switch 05 / 06 Amps. |
| 82 | All as per item No-1 here -in- before but for One 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch. |
| 83 | All as per item No-1 here -in- before but for One 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch. |
| 84 | All as per item No-1 here -in- before but with 4.0 Sqmm nominal cross sectional area copper conductor cable for one 15/16 Amps socket outlet point on independent board. |
| 85 | Supply and fix Tube light fitting integrated type suitable for LED 20W indoor decorative aluminium extruded T5 LED batten complete with hosing with all accessories pre wired and making connection with threecore copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 86 | Supply and fix Tube light fitting integrated type suitable for LED 10W indoor decorative aluminium extruded T5 LED batten complete with hosing with all accessories pre wired and making connection with threecore copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 87 | Supply and fixing inverterLEDlamp 12 wattcomplete all as specified and direcred . |
| 88 | Supply & fixing MCB DB Box 6 way 100 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed. |
| 89 | Supply & fixing MCB , SP, AC, 240 volts of 05 to 32Amps capacity 10KA, \"C\" series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 90 | Supply & fixing MCB, DPAC, 240 volts of 40 to 63 Amps capacity 10KA, \"C\" series and making connections with suitable size of copper lugs complete all as specified & directed. |
| 91 | Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.5 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completioncomplete all as specified and directed.Note- After completion of work if desired test result is not obtained the earthing to be redone with out any extra cost of department |
| 92 | S & F Modular Switch 1 way 6 A, 1 module complete all as specified and directed by Engr-in-Charge. |
| 93 | S & F Modular Switch 1 way 16 A, 1 module complete all as specified and directed by Engr-in-Charge. |
| 94 | S & F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed by Engr-in-Charge. |
| 95 | S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed by Engr-in-Charge. |
| 96 | Supply and fixing LED security light fitting 1x60 Watt luminaries with die cast aluminium housing IP-66 comprising epoxy powder coated enclosed with glass coverembedded lensin frame with high power LED white lamp complete all as specified and directed |
| 97 | Supply & fixing lamp holder (Angular/Straight), insulated body, with back plate for batten fitting complete all as specified & directed |
| 98 | Supply & fixing of ceiling rose surface bakelite 65x 50mm three terminals complete all as specified & directed. |
| 99 | Material and labour for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade with cross sectional area10 Sqmm, 2 core complete |
| 100 | Material and labour forBrickscommon burnt clay building bricks, sub-class ‘B’designation 75 for protection of UG LT cable all as specified. |
| 101 | M&L for sand filling in trenchesfor cushioning of cable complete all as specified and directed. |
| 102 | Supply install and tesing water heater storage type (Geyser) single phase 230 V, 50 Hz, 5 star energy saving high density PUF insulation tank made of heavy duty mangesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type 25 Ltr Cap 2000 Watt rated power, incoloy 800 glass coated heating element, inner tank coating of feroglas powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8 MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat, digital display and adjustable knob for setting of temperature. The temperature range 25 to 75 degreecelsiusincluding connecting up and fixing arrangement on wall including providing hole fastners-04 Nos hot and cold water metallic flexible pipes 15 mm bore of adequate length as provided by OEM or required at site - 02 Nos non return valve 01 No and including necessary plumbing work, complete with intergated shock safe plug with all protection features as per OEM design and standard all as specified and directed. |
| 103 | M&L for Cutting of GI Pipes line 40mm dia and reducingto required length before laying in position for insertion of new tees, branches etc complete all as specified & directed. |