| 1 | Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. |
| 2 | Earthworkinexcavationoffoundationtrenchesor drains,inallsortsofsoil(includingmixedsoilbut excludinglateriteorsandstone)includingremoving, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm. |
| 3 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc.layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work). With earth obtained from excavation of foundation. |
| 4 | Fillinginfoundationorplinthbysilversandin layers not exceeding 150 mm as directed and consolidatingthesamebythoroughsaturationwith water, ramming complete including the cost of supply ofsand.(paymenttobemadeonmeasurementof finished quantity) |
| 5 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stackingserviceable materials at site and removing rubbish as directed. within a lead of 75 m. In all floor including roof. |
| 6 | Dismantlingalltypesofplaincementconcrete works,stackingserviceablematerialsatsiteand removingrubbish asdirected withina leadof 75m. In all floor including roof. upto 150 mm. thick |
| 7 | Labour for taking out wove wire or similar net (from fencing) including the cost of taking out staples (by cutting or otherwise,as necessary). Net upto 1350 mm. height. |
| 8 | TakingoutcarefullyG.C.I.orC.I.orasbestos sheets(includingridgesetc.)fromrooforwall after unscrewing bolts, nuts, screws etc.and stacking the material at site as directed. |
| 9 | Strippingoffwornoutplasterandrakingout joints of walls, celings etc. upto any height and in anyfloorincludingremovingrubbishwithina lead of 75m as directed. |
| 10 | Removalofrubbish, earthetc.fromtheworking siteanddisposalofthe samebeyondthe compound,inconformitywiththeMunicipal/ Corporation Rules for such disposal, loading into truckandcleaningthesiteinallrespectasper direction of Engineer in charge |
| 11 | SingleBrickFlatSolingofpickedjhamabricksincludingrammingand dressing bed to proper level and filling joints withlocal sand. |
| 12 | Brick work with 1st class bricks in cement mortar (1:4). In foundation and plinth |
| 13 | 125mm.thickbrickworkwith1stclassbricksincementmortar(1:4)in all floor. |
| 14 | OrdinaryCementconcrete(mix1:2:4)withgradedstonechips(20mm nominal size) excluding shuttering and reinforcement,ifany, in all floor as per relevant IS codes. |
| 15 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thicknesswithrequiredbracingforconcreteslabs,beamsandcolumns, lintelscurvedorstraightincludingfitting,fixingandstrikingoutafter completion of works (upto roof of all floor). 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 16 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar includingroundingofforchamferingcornersasdirectedand rakingoutjointsincludingthroating,nosinganddripcourse, scaffolding/staging wherenecessary(allfloor).[Excluding cost of chipping over concrete surface]. With 1:4 cement mortar. 20 mm thick plaster |
| 17 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per 100 sq.m. |
| 18 | Supplying, fitting& fixing Zn-Alalloy (55% Al & 45% Zn) coatingof150gramspersq.metre(followedbycolour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted andfixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia& 3mm th.washer etc.complete with150mmendlap and one corrugation minimum side lap. (Payment to be made on area of finished work). In Roof:- With 0.5 mm thick sheet |
| 19 | M.S.structuralworksincolumns,beamsetc.withsimplerolled structuralmembers(e.g.joists,angle,channelsectionsconforming toIS:226,IS:808& SP(6)-1964connectedtooneanotherwith bracket,gussets,cleatsasperdesign,directionofEngineer-in- chargecompleteincludingcuttingtorequisiteshapeandlength, fabrication with necessary bolting, metal arc welding conforming to IS:816-1969& IS:1995usingelectrodesofapprovedmakeand brandconformingtoIS:814-2004,haulage,hoistinganderection allcomplete.Therateincludesthecostofrolledsteelsection, consumables such as electrodes, gas and hire charge of all tools and plantsandlabourrequiredfortheworkincludingallincidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural membersonly infinished work as perIS specifiedweight. Payment forgusset,bracket,cleat,rivets,boltsandnutsmaybemakeby addingtheactualweightofsuchitemswiththeweightoffinished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allowforbracket,cleat,rivet,boltsandnutsetc.andnoseperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floorlevelfrom the all. Add1.5%extraoverthe rate for each additional floor or 4m. beyond initiial 8m. or part thereof. For structuralmembersofspecifiedsectionsweighinglessthan 22.5 Kg./m |
| 20 | M.S.or W.I. Ornamental grill of approved design joints continuouslyweldedwithM.S,W.I.Flatsandbarsofwindows, railing etc. fitted and fixed with necessary screws and lugs in all floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor). Grill weighing above 16 Kg./sq.mtr and above |
| 21 | Square or hexagonal mesh netting made with 18 B.W.G.galvanised wire, fitted and fixed complete as per design (excluding the supporting framework but including local sal wood battens of size 37.5 mm x 25 mm). 25mm mesh. |
| 22 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorativetextured(mattfinish)orsmoothfinishacrylicexterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. In all Floor: One Coat. |
| 23 | Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer\"s specification. In all Floor: Two coats. |
| 24 | Protective and Decorative Acrylic exterior emulsion paint of approved quality,aspermanufacturer\"sspecificationandasperdirectionof Engineer-in-Charge to be applied over acrylic primer as required. The rateincludescostofmaterial,labour,scaffoldingandallincidental charges but excluding the cost ofprimer. In all floor (Two Coat). Premium 100% Acrylic Emulsion |
| 25 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitatingtheuseofscraper,wirebrushetc.(Paymentagainstthis item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
| 26 | Primingonecoat onsteelorothermetalsurfacewithsyntheticoil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 27 | Paintingwithbestqualitysyntheticenamelpaintofapprovedmake and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: On steel or other metal surface : With super gloss (hi-gloss) - Two coats (with any shade except white) |
| 28 | Painting with superior quality aluminium paint of approved make and brandincludingsmootheningsurfacebysandpaperingetc.onsteel surface : Two coats |
| 29 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. Single Socketed 3 Meter Length. Dia 110 mm. |
| 30 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials. Above ground. Dia 110 mm. |
| 31 | Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above all. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately). For Exposed Work. 25 mm dia. medium quality |