| 1 | Providing lift operators for rescue & coordinationofKONE make liftsas per inventory and terms & conditions attached.(i) Lift rescue operator Gr-II- 3 Nos |
| 2 | Operation & maintenance of DG set, electrical & fire installations / equipment’s,FA& PA system along with duplex type Talk back system and CCTV system as per additional conditions, inventory at annexure A & preventive maintenance schedule at annexure B attached. (i) Wireman Gr-I1 Nos( In generalshift)(ii)Pump operator Gr-II - 9 Nos (3 No. In each shift round the clock.)(ii) Khallasi Gr-III-3 Nos (1 No. In each shift round the clock.) |
| 3 | Supplying & replacement of storage type lead acid battery of following rating with minimum 3 year warrantyfor different DG sets i/c P/F battery cable , thimbles, connections, testing etc. as reqd. a)12 V , 180 AH |
| 4 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body materialand construction as per IS : 10322 withdriver (Replaceable)as per the requirement with Driver efficiency >85% ,Operating voltage AC140-270 Volt,freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80, Flicker free, (flickershould be below 5 %), life time (LED,Driver & electrical circuitary), ofminimum 50000BurningHourswith,70%ofinitial Lumenmaintained tilllife ends, CCT3000°K/ 4000°K / 5700°K/6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard andtrade markcertificate(T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completeinallrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥105 <120lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C). Powdercoated CRCA sheetBody (Thickness≥ 0.5 mm). |
| 5 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 250 Amp |
| 6 | 125 A |
| 7 | 100A |
| 8 | Supplying & Replacement of 3 Pole Power Contactors of following rating in the existing panel board suitable for 415 volt, 50 Hz, 3 Phase AC supply i/c connection testing commissioning etc. complete as reqd. a) 125 Amp,AC-3, Type ML-6 |
| 9 | a) 100 Amp,AC-3, TypeML-4 |
| 10 | b)45 Amp,AC-3,Type ML-3 |
| 11 | Providing and fixing following rating and breakingcapacity and pole MCCB with thermomagneticrelease and terminal spreaders in existing cubiclepanel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required. a) 250 A,50KA,FPMCCB |
| 12 | b) 200 A,36KA,FPMCCB |
| 13 | c) 125 A,36KA,FPMCCB |
| 14 | Supply and drawing of followingsizes of FRLS /HFFR/PVC insulated ,single core copper conductorcable in the existing surcace / recessed steel / PVC conduit as required. a)2x1.5 sq. mm |
| 15 | b)2x4 sq. mm |
| 16 | Dismantling and repairingi/c S/R of following worn out parts of existing 12.5HP clear water pumpof kirloskar make suitablefor operationon 415 volts , 3 phase ,50 hz ,AC supplyi/c re-assembling/re-installation the same, connection with suction and delivery line, valves, testing etc. completed as reqd:- (i) S/R of Pump shaft (SS)- 1 No. |
| 17 | (ii) S/R of Bal bearing - 2 Nos. |
| 18 | (iii) S/R of Gland plate- 2 Set |
| 19 | (iv) S/R of Gland bush- 2 Nos . |
| 20 | (v) S/R of impeller-1 Nos . |
| 21 | Dismantling and rewindingi/c S/R of following worn out parts of existing 12.5HPkirloskar make Induction motor(for clear water) i/c re-assembling/re-installation the same, connection with suction and delivery line, valves, testing etc. i/c rotor turning,coupling,connection plate etc.completed as reqd:-(i) Rewinding of 12.5 HP motor - 1No. |
| 22 | Supply Installation,Testing and commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85,Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required. |
| 23 | Servicing of 100/125 KVA DG set (Cummins make engine) i/c supply and replacement of following items testing etc complete as required.i) Oil Filter - 2 Nosii)Diesel Filter -2Nos.iii) Air cleaner element- 1 setiv) Coolant- 5 ltrv)Battery terminal- 4 Nos.vi)Engine oil-35 ltr |
| 24 | Servicing of 25/40 KVA DG Set (Kirloskar make engine) i/c supply and replacement of following items testing etc complete as requiredi) Oil Filter -1 No.ii) Diesel Filter -1 set.iii) Air cleaner element-1 setiv) Coolant-3 ltrv) Battery terminal-2 Novi) Engine oil-10 ltr |
| 25 | Repairing of AMF panel of 125KVA//100KVA D.G set with supplying and replacement of following parts i/c connection testing& commissiong etc complete as required. a) panel comlpete wiring with materials-1No b)Battery charger 24 volt -1 No c)Relay 8 pin-2 nos. d)Relay 4 pin-2 Nose)starter Relay-1 No f) push button -2 Nos.g)panel repairing and servicing charges. |
| 26 | Repairing of AMF panel of 40KVA D.G set with supplying and replacement of following parts i/c connection testing& commissiong etc complete as required.a) panel comlpete wiring with materials-1No b)Battery charger 12 volt -1 No c)Relay 8 pin-2 nos.d)Relay 4 pin-2 Nos e)starter Relay-1 Nof) push button -2 Nos.g)panel repairing and servicing charges. |
| 27 | Supply and Replacement of Automatic star delta starter suitable upto 125 HP centrifugal pump sets suitable for 415 volt,50 Hz AC supply,i/c dismantling the Existing damaged/burnt out i/c connection,testing etc completed as required |
| 28 | LED Flood Light, powder coated pressure diecast aluminium (System lumen efficacy ≥105 <120lm/Watt).Supplying, Installation, Testing & Commissioningof Flood Light, powder coated pressure die castaluminium body with built in or separate driver asper the requirement with Driver efficiency>85%,Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to52 DELHI SCHEDULE OF RATE (E&M) 2025 ,50 0C, internal surge protection of 5 KV L,N,E as perIEC 61000-4-5, Driver efficiency >85%,THD < 10%as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beamangle 30 deg-120deg as per the application and theproject requirement., suitable tilt able fitting, life time(LED, Driver & electrical circuitry) of minimum 50000Burning Hours with 70% of initial Lumenmaintained till life ends as per LM80extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Color Matching) <5,Maximum power consumption should not morethan the specified rating and Fixture shall be ofrelevant BIS standard complete in all respect i/cexternal connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumenefficacy ≥105 <120 lm/Watt output .LM79 & LM80Test report and all testing required for LEDfixtures as per BIS shall be submitted.. Shape sizeand CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C) a) 150 watt. |
| 29 | Supplying of following size of XLPE aluminum conductor armoured powercable of 1.1 KV grade including providing & fixing thimbles connection,testing etc as required at site.a) 2CX10 sq.mm Size |
| 30 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kv grade of following size on wall surface as required.a) UP to 35 sq.mm ( clamped with 1mm thick saddle.) |
| 31 | Dismantling and reparingi/c S/R ofworn out parts of existing 3HP Dewatering pump(sewage sub.type/weda type)i/c re-assembling/re-installation the same, connection with suction and delivery line, valves, testing etc. completed as reqd:- |
| 32 | Supplying and fixing 3 inch flexible hosepipe for dewatering pump in basement i/c connection,testing complete as required |