| 1 | Excavation in trenches ot exc 1.5 m width and not exc 1.5m in depth getting out for laying of pipes etc soft/oose soil |
| 2 | Returning filling in including spreading levelling watering and ramming in layers not exceeding 25 cm in any type ofsoil. |
| 3 | Removing excavated surplus soil to a distance not exceeding50M where directed and at a level not exceeding 1.5 M above the starting point. |
| 4 | Supply and fixing of electric layout diagram board of water supply pump and distribution line with LED indication as per existing and amendment to diagram of size 2.0 x 1.5 mtr all as specified and directed by engineer-in-charge. Note : Contractor will disign and submit layout plan to EIC |
| 5 | Supply and fixing of LED electric board with name of installation of size 2.0 x 1.0 mtr, including suitable size of cable as required all as specified and directed by engineer-in-charge. |
| 6 | Programming and make arrangment to screen sharing of an existing SCADA system (flow meter) with one user through the remote desktop access, it allows the user to view real time data of the existing SCADA system. |
| 7 | Supply, Installation, Testing and Commissioning of HMI that’s suitable for existing PLC Panel - Touch screen, TFT 7” Colour Liquid crystal display, Display character 16-dot standard font: 50 characters x 30 rows (two-byte characters), Display colour more then 10k, 32-level brightness, Built in interface with RS 232, RS485/422, Ethernet, USB, SD card, Internal Flash memory 15MB, Input power supply voltage 24VDC(+10% -15%) Ripple voltage 200mV or less, operating temperature :0 deg to 50 deg / storage temperature : -20 deg to 60 degMake :Unitronics / Mitsubishi /Renu/Siemens/Schneider |
| 8 | Supply, Installation, Testing and Commissioning of motor actuated valve of size 150 mm dia complete single phase motor actuated withgear box valve set compatible, hand wheelfor manual operation, pressure rating of 10 kg/sq cm and having 02 nos limit switches foropen / closed condition and capability of accepting 4-20mA input complete setNote:Motor Actuated Valve should be compatible with existing SCADA ( All the functions of Motor Actuated Valve should be control remotely from existing SCADA) Make :Unitronics / Mitsubishi /Renu/Siemens/Schneider |
| 9 | Supply, Installation, Testing and Commissioning of motor actuated valve of size 200 mm dia complete single phase motor actuated withgear box valve set compatible, hand wheelfor manual operation, pressure rating of 10 kg/sq cm and having 02 nos limit switches foropen / closed condition and capability of accepting 4-20mA input complete setNote:Motor Actuated Valve should be compatible with existing SCADA ( All the functions of Motor Actuated Valve should be control remotely from existing SCADA) Make :Unitronics / Mitsubishi /Renu/Siemens/Schneider |
| 10 | Supply and fix in replacement of Butterfly valve of size 150 mm dia.PN 16 suitable for coupler with Existing actuator operation rate for modification in adopter to make fit with existing actuator shall be deemed to be includedin rate quoted by contactor.Make: L&T/Sant/Zoloto or equivalent |
| 11 | Supply and fix in repalacement of Butterfly valve of size 200 mm dia.PN 16 suitable for coupler with Existing actuator operation rate for modification in adopter to make fit with existing actuator shall be deemed to be included in rate quoted by contactor.Make: L&T/Sant/Zoloto or equivalent |
| 12 | Supply and fixing in repair digital Soft starter of capacity 12.5 HP,M:200-525VAC,C110/220VAC with built in bypass contactor, USB port for for easy and fast communication and data extraction, full graphical display with multi language support, real time graph of motor operating performance, advanced protection system, smart card for level controlled pump activation and pump protection, under voltage/over voltage protection, fire mode function with accessories complete including testing and commissioning complete all as directed. Make: L&T/Schneider/ABB. |
| 13 | Supply and fixing in repair digital Soft starter of capacity 75 HP,M:200-525VAC,C110/220VAC with built in bypass contactor, USB port for for easy and fast communication and data extraction, full graphical display with multi language support, real time graph of motor operating performance, advanced protection system, smart card for level controlled pump activation and pump protection, under voltage/over voltage protection, fire mode function with accessories complete including testing and commissioning complete all as directed. Make: L&T/Schneider/ABB. |
| 14 | Supply and fix in replacement of Kit Fan M/R 0041-0129. make L & T or as per existing model EMX4iof capacity 24 Amp to 135 Amp, |
| 15 | Supply and fix in replacement of Kit SCR M/R 0060-0069 make L & T or as per existing model EMX4iof capacity24Amp to 135 Amp |
| 16 | Supply and fix in replacement of Kit CT M/R 0020-0129 make. L & T or as per existing model EMX4iof capacity 24 Amp to 135 Amp |
| 17 | Supply and fix in replacement of Kit snubber M/R 0085-0129 make L & T or as per existing model EMX4iof capacity 24Amp to 135Amp |
| 18 | M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in kerbs or benching etc including necessary form work complete all as specified and as directed. |
| 19 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings, complete all as specified and as directed. |
| 20 | S&F Pre-painted galvolume aluminum zinc coating GI based corrugated/ plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed. |
| 21 | Dismantling of MS or wrought iron work of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 22 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 |
| 23 | Preparing new or previously untreated surfaces of steel or iron work of any description and girth over 10cmand applying two coats of synthetic enamel paint complete all as specified andas directed. |
| 24 | Taking up raising/ delivery DI water/STP mains 250/200mm bore (including all fittings), with flanged or spigot and socket end with tyton joints/ gasket with nut bolts & washers of any size and relaying the same with using new gasket / tyton jointcomplete all as specified and dirercted by Engr-in-Charge. Note :- During execution of the work if any damages in pipe line contractor will repleced same with new without extra charges. Rate ofExcavation and earth work returning filling and removing shall be deemed to be included in the rate quoted by contractor. |
| 25 | Taking up raising/ delivery DI water/STP mains 150mm bore (including all fittings), with flanged or spigot and socket end with tyton joints/ gasket with nut bolts & washers of any size and relaying the same with using new gasket / tyton jointcomplete all as specified and dirercted by Engr-in-Charge. Note :- During execution of the work if any damages in pipe line contractor will repleced same with new without extra charges. Rate ofExcavation and earth work returning filling and removing shall be deemed to be included in the rate quoted by contractor. |
| 26 | M & L for taking up 200mm cast iron/DI/HDPE/PVC water mains (including all fittings), with spigot and socket ends and lead joints of any size all as specified and dirercted by Engr-in-Charge. |
| 27 | Supply and lay 200mm DI pipe centrifugally cast of class K-7 with spigot and socket ends/flanged endsuitable for tyton joints/flanged jointsincluding rubber gasket/rubber ring and other accessories like nut-bolts etc. |
| 28 | Material and labour for fixing DI specials such as bends(any type, radius and angle),tappers any type, (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps & plugs of sizes upto 300mm. |
| 29 | Supply and Fixing for DI sluice valve 200mm, PN-1.6 incl new rubber gasket, nuts and bolts SS spindle etc and dismentling of existing unserviceable one |
| 30 | M&L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6.00 mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point all as specified and testing on completion includingprovisionof earth lead protected by 40 mm bore light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earh work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M[ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways.[iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd.[v]. GI protection pipe of size 40 mm bore light grade 7.5m |
| 31 | M&L for repair of leakage of pipe line 15 to 25 mm dia any position upto height 25 mtr incl exacavation, dewatering, cleaning, repairing of pipe line leakage with reqd all accessories at site and returning and matching as per existing complete all as specified and directed.Note :- Repair maint/break down work should be rectify at the earliest same day of complaint otherthan delay may be penalised Rs:1000/- per/Hour. |
| 32 | M&L for repair of leakage of pipe line 32 to 80 mm dia any position incl exacavation, dewatering, cleaning, repairing of pipe line leakage with reqd all accessories at site and returning and matching as per existing complete all as specified and directed. Note :- Repair maint/break down work should be rectify at the earliest same day of complaint otherthan delay may be penalised Rs:1000/- per/Hour. |
| 33 | Repairing and servicing of Invertor upto 2000VA including burnout part/wiring ect all as specified and directed by Engr-in-Charge. |
| 34 | Supply and fixing tubular battery lead acid 12v, 150ah with complete accessories all as specified and directed by Engr-in-Charge. |
| 35 | Material and labour for reapiring of LT panel including welding/hinge repairing of doors of panels. Taking out old control wiring any size from panel and M&L for new control wiring same as existing control wiring complete and testing of panel after reapir complete all as directed by EIC. |
| 36 | M&L for painting of Valve Chambar plaster portion with cement base and steel portion with synthetic enamel paint of any size |
| 37 | M&L for painting of distribution header at various pump house/OHT of any size of CI/DI/GI pipe,tee,bend,elbow etc painted with synthetic enamel paint as directed by engineer-in-charge. |
| 38 | Taking out old DI/CI pipe of size 300/350/400mm from existing header at various pump house/OHT and Supply and lay DI pipe of size as per existing, centrifugally cast of class K-9 with flanged/spigot and socket ends suitable for tyton jointsincluding rubber gasket header at various pump house/OHT. Providng any type of special tools & plants such as JCB, Hydra cranes, pumps & materials (such as lead, lead wool, detechable joints/ leak repair clamp suitable for CI/DI fittings,patsun/spun yarn, caller/short piece of pipes or any other fittings to be required to minimise the breakdown time and rectification of the problem as soon as posible. Rectification work must be start within two hours of intimation to contractor. Any delay in rectification may be penalised as deemed fit , Rate of excavation removing and returning filling willbe deemed to be included in the rate quoted by contractor. |
| 39 | Taking out/up 150/200/250mm size of distrbution header tee, bend at varoius pump house/OHT and relaying/refixing the same with using new gasket / tyton jointcomplete all as specified and dirercted by Engr-in-Charge.Note :- Rate ofExcavation and earth work returning filling and removing shall be deemed to be included in the rate quoted by contractor |
| 40 | Taking out/up 300/350/400mm size of distrbution header tee, bend at varoius pump house/OHT and relaying/refixing the same with using new gasket / tyton jointcomplete all as specified and dirercted by Engr-in-Charge.Note :- Rate ofExcavation and earth work returning filling and removing shall be deemed to be included in the rate quoted by contractor |
| 41 | Taking out old and Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, any CPRI approved factory made, floor mounted out door, canopy type Panel ofsize 1.2 x 1.6 M,centre opening in two halve front, inner door shall be individual hinged type door for individual control switches made, out of CRCAsheet2.0mm thick inner doors and outer door made out of 3 mm thick with locking arrangement , duly powder coated & mounted on angle iron frame , made out of50 x50 x6 mm angle iron frame and legs made of angle iron of size 50 x 50 x 6 mm 60 CM long total 04 Nos one at each corner duly fixed with PCC etc incl control wiring with Copper wire along with cable gland for incomming and outgoing connection complete to accommodate the following accessories :- .(a) MCCB100 Amps, 16KA, 4 pole,415 Volts adjustable type– 01 N0 (b) MCCB32 Amps ,16KA, 4 pole,415 Volts adjustable type– 03 Nos (c)12.5 HP star delta starter - 01 No (d) Ammeter digital type having scroll type switchwith CT’s- 03 Set (e) Voltmeter Digital type in one positionhaving scroll type switch with PTs - 01 Set (f) LT danger notice plate made out of 1.6 mm thick MS sheet - 01 No (g) Indicator lampLED type (set of 3) - 4 set (h) Selector switch - 04 Nos (j) Single phase preventor (k) Phase indicator lamp - 04 set (l) Push button start stop - as required (m) Copper bus bar - as required (n) Provn of Soft starter of capacity suitable for 12.5 HP motor - 02 Nos. (m) Contactor 32A - as required,Note :- 1. Rates quoted must be included of panel accessories like cable gland, control wiring, Bus bar, Digital Ammeter, Voltmeter, danger plate, indicator lamp, push button, single phase preventor,MCCB, Copper bus bar, angle iron for base and legs, PCC etc. |
| 42 | Taking out old and Supply, installation, testing and commissioning LT 415 Volt, 4 wire AC 50 Hz, any CPRI approved factory made, floor mounted out door, canopy type Panel ofsize 1.2 x 1.6 M,centre opening in two halve front, inner door shall be individual hinged type door for individual control switches made, out of CRCAsheet2.0mm thick inner doors and outer door made out of 3 mm thick with locking arrangement , duly powder coated & mounted on angle iron frame , made out of50 x50 x6 mm angle iron frame and legs made of angle iron of size 50 x 50 x 6 mm 60 CM long total 04 Nos one at each corner duly fixed with PCC etc incl control wiring with Copper wire along with cable gland for incomming and outgoing connection complete to accommodate the following accessories :- .(a) MCCB250 Amps, 16KA, 4 pole,415 Volts adjustable type– 01 N0 (b) MCCB125 Amps ,16KA, 4 pole,415 Volts adjustable type– 02 Nos (c)Provision of soft starter capacity of 75hp - 02 No (d) Ammeter digital type having scroll type switchwith CT’s- 03 Set (e) Voltmeter Digital type in one positionhaving scroll type switch with PTs - 01 Set (f) LT danger notice plate made out of 1.6 mm thick MS sheet - 01 No (g) Indicator lampLED type (set of 3) - 4 set (h) Selector switch - 04 Nos (j) Single phase preventor (k) Phase indicator lamp - 04 set (l) Push button start stop - as required (m) Copper bus bar size 1.5 time of incomer amp - as required length (n) Suitable size of contactor for 75hp soft starter - 02 NosNote :- 1. Rates quoted must be included of panel accessories like cable gland, control wiring, Bus bar, Digital Ammeter, Voltmeter, danger plate, indicator lamp, push button, single phase preventor, contactor,MCCB, Copper bus bar, angle iron for base and legs, PCC etc. |
| 43 | Taking out existing inerlocking tile carefully and relaying same as per exiting including all material.Note :- During execution of the work if any damages like tile, PCC, cement etc contractor will repleced same with new without extra charges. Rate ofExcavation and earth work returning filling, leveling and removing shall be deemed to be included in the rate quoted by contractor. |
| 44 | Taking out old unserviceable solar street light and supply & fixing new all in one solar LED street light set 24 watt, mono crystalline solar panel PV module 60w, IP65 rating, lithium ferro phosphate battery 30Ah, MPPT solar charge controller complete as directed by Engr-in-Charge. MAKE : Jaquar &Co Pvt Ltd, Havells, Philips. |
| 45 | Taking up / down old CI/DI/GI tubing connection including clearing (from trenches/wall/roof) complete as directed by Engr-in-Charge ofsize 20mm bore |
| 46 | All as per item ser No 47 above but for size 25mm bore |
| 47 | All as per item ser No 47 above but for size 50mm bore |
| 48 | M&L galvanised iron pipe medium grade (ISI marked) with and includingfittingsmedium grade (ISI Marked)concealed or fixed to walls, celling or laid in floors including chase cuttings where required, making good to distributed surfaces as per existing as directed and specified of size 20mm bore.Note: Cost of cutting/leaving/forming chases, holes etc through walls, floor, plinth protection, roof etc as required and making good the surface to match as per existing shall deemed to be included in quoted rate by the tenderer. Make : Tata , Jindal, Prakesh surya.All as per ser item no 2 above but of size20mm bore. |
| 49 | All as per ser item no 48 above but of size25mm bore. |
| 50 | Supply and fixing of galvanised iron pipe medium grade (ISI marked) with and including fittings medium grade (ISI Marked)laid in trenches jointed and tested complete all as specified and directed for thesize 20mm bore.Make : Tata , Jindal, Prakesh surya. |
| 51 | All as per ser item no 50 above but of size25mm bore |
| 52 | All as per ser item no 50 above but of size50mm bore |
| 53 | Supply and fix gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed of size20 mm dia incl taking down and removal from site:-Make: Normax, Sant, Zoloto,Kartar |
| 54 | All as per ser item no 53 above but of size25 mm dia. |
| 55 | Dismantling of stone massonary valve chamber of any size and pattern and at any position and construction of valve chamber with PCC foundation 1:4:8 type D2 using 40mm graded stone aggregate PCC block 20 cm thick wall massonary built in cement mortar 1:6 with plastering of 10mm thickness internally and 15mm thickness externally above and below ground level with PCC 1:2:4 type B1 using 20mm graded stone aggregate inclframe made of angles iron of size matches with the internal size of the valve chamber and chamber cover made of MS sheet of 3.0mm thickness incl MS hinge and painting the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer incl necessary earth work, excavation etc all as specified and directed by Engr-in-Charge of the size 1050 x 1200 x 1000mm. |
| 56 | Supply, testing of water quality upto portabely adding Calcium Hypochloride 65%-70% chlorine contebnt (calcium based granular) for drinking water, disifectant for water treatment packed in 45 kg drum complete all as specified and directed |
| 57 | Supply, testing of water quality upto portabely adding for Febricd alum IS-299:2012 Grade IV drinking water complete all as specified and directed |
| 58 | M&L 15 mm thick cement plaster in cum (1:6) on brick/stone/PCC surface fair and even complete all as directed. |