| 1 | M&L for isopathic resin coating with fibre glass, and leak proof joint material over Fume Extraction System Tower Tank (11 No\"s)at EP shop,duly completed by expert technician complete all as specified and directed by Engr-in-charge.Note : Rate quoted deemed to inclusive of removal of old existing coating complete from surface and fixing of new coating all as specified. |
| 2 | M&L for resin coating material material over Fume Extraction System Duct (11 No\"s)at EP shop,duly completed by expert technician complete all as specified and directed by Engr-in-charge.Note : Rate quoted deemed to inclusive of removal of old existing coating complete from surface and fixing of new coating all as specified |
| 3 | M&L for fixing of \"I\" bolt of size 5x8 inches and 12 inch long and strength suitable for fixing of FES duct arrangementcomplete all as specified and directed byb Engr-in-charge |
| 4 | M&L for taking out existing centrifugal pump setfrom its location including dismantling from existing FES structure and opening of pump set, cutting of existing burnt winding of 15 HP motor and rewinding of motor and refixing at original location complete with suitable size of copper wire complete all as specified and directed by Engr-in-Charge |
| 5 | M&L for taking out existing Non Clog Pump Setfrom its location (Treated water tank) including dismantlingand opening of pump set, cutting of existing burnt winding of 10 HP motor and rewinding of motorand refixing at original location complete with suitable size of copper wire complete all as specified and directed by Engr-in-charge. |
| 6 | M&L for taking out existing monoblock pump from its location and opening of pump, cutting of existing burnt winding of 1 HP motor and rewinding of motor complete with suitable size of copper wireand refixing at original location complete all as specified and directed by Engr-in-charge. |
| 7 | M&L for taking out existing monoblock pump from its location and opening of pump, cutting of existing burnt winding of 3 HP motor and rewinding of motor complete with suitable size of copper wireand refixing at original location complete all as specified and directed by ENgr-in-charge. |
| 8 | M&L for replacement of existing impeller set of capacity 9000 CFM, rotary type twin to be having electric motor of 15 HP including taking out from existingbroken impeller from casing complete all as specified and directed by Engr-in-charge. |
| 9 | M&L for replacement of existing impeller set suitable for 7000 CFM rotary type twin lobe having electric motor of 15 HP including taking out from existingbroken impeller from casing complete all as specified and directed by Engr-in-charge. |
| 10 | Supply and installation of neutralization tank of approximately size 12.5 x 4.8 x 4.8 feet made of PPGL material of high quality complete including taking out of existing broken tank from steel structure and fixing of new tank with same specification at its position complete all as specified and directed by Engr-in-charge.Note : Rate quoted are inclusive of Transportation, installation and comissioning |
| 11 | Supply and installation of alkaline/ acidic collection tankapproximately size 6.5 x 6 x 6 feet made of PPGL material of high quality complete including taking out of existing broken tank from steel structure and fixing of new tank at its position complete all as specified and directed by Engr-in-charge.Note : Rate quoted are inclusive of Transportation, installation and comissioning |
| 12 | Supply, Laying,jointing of \"U\" PVCPipe 20 mm dia in replacement including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches / floor/ walls etc all as specified and as directed by Engineer in Charge. |
| 13 | Supply, Laying,jointing of \"U\" PVCPipe25 mm dia in replacement including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches / floor/ walls etc all as specified and as directed by Engineer in Charge. |
| 14 | Material and labour for opening/ dismantling of existing Filter body, fixing / welding of strainer mesh of appropriate dia as per filter body size and refixing of filter body after filling of filter media complete all as specified and directed by Engr-in-charge.Note : Filter media will be measured under respective BOQ item |
| 15 | Supply and filling of activated filter media of quartz sand of suitable size and filtration capacity as per site requirement all as directed by Engineer in Charge. Note: Qty of Quartz sand braight at site shall be recored in MB |
| 16 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, all as specified and directed |
| 17 | M&L for framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of Ladder in Over Head Tankand similar work con-forming to Fe 290.Gde-E-165complete all as specified and directed.Note :- Necessary safty tools and measure should be the whole responsiblity of contractor andrate of all T & P included in quoted rates. |
| 18 | M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of newly steel surface of any description exc. 10 cm width or girth complete all as specified and directed |
| 19 | Supply & fixing in replacement of fan belt \"V\" type of specification B 95, complete all as specified & directed by Engr-in-charge |
| 20 | Supply & fixing in replacement of fan belt \"V\" type of specification B 68, complete all as specified & directed by Engr-in-charge |
| 21 | S&F of Isolation Pad (damper) of required size for holding of vibration of motor and duct system at force draught system complete all as specified & directed by Engr-in-charge |
| 22 | S&F in replacement of of monoblock block pump set of 1 HP capacity, head range 6-34 RM, discharge range of 2700 to 750 LPH complete all as specified & directed by Engr-in-Charge.Note : Old motor shall be deposited to MES store yard |
| 23 | S&F in replacementof monoblock block pump set of 15 HP capacity, RPM 1460 , IP 55, S1 duty suitable for FDS system at EP shop complete all as specified and directed by Engr-in-charge.Note : Old motor shall be deposited to MES store yard |
| 24 | Supply only GI wire rope stranded 10 mm dia for hanging ofFES Duct System including GI clamp of suitable size etc complete all as specified and as directed. |
| 25 | Supply & fixing in replacement of Effluent Collection Tank suitable for capacity of 2200 litre.The tank thickness shall be minimum 10mm. The tank shall be made up of PP & lined with FRP coating of suitable thickness as per site requirement. Tanks shall be capable of handling chemicals like ARDOX 633A-2526-6025, ORION 68, ZL 37-27A-2C-10B, CHROMIC ACID, RDP etc.The tank shall be equipped with openable type cover of suitable size for maintenance purpose.The cover shall be designed in specific manner for smooth operation complete all as specified and directed by Engr-in-charge |
| 26 | Supply & fixing in replacement of Effluent Collection Tank suitable for capacity of 1150 litre.The tank thickness shall be minimum 10mm. The tank shall be made up of PP & lined with FRP coating of suitable thickness as site requirement.Tanks shall be capable of handling chemicals like ARDOX 633A-2526-6025, ORION 68, ZL 37-27A-2C-10B, CHROMIC ACID, RDP etc.The tank shall be equipped with openable type cover of suitable size for maintenance purpose.The cover shall be designed in specific manner for smooth operation complete all as specified and directed by Engr-in-charge |
| 27 | S&Fin replacemnt of float valve of SS of size 25 mm of grade 316 complete all as specified & directed by Engr-in-charge |
| 28 | S&F of fibre glass canvas cloth for fixing in Force Draught System (FDS), including removal of old cover from existing system complete all as specified & directed by Engr-in-charge |
| 29 | M&L (in replacement) for earthing complete with MS galvanized earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal GL) with top edge of the plate not less than 1.50m below normal GL, earth plate surroundly filledcharcoal and common salt in alternate layer (min 40 Kg charcoal & 40 Kg salt) complete covering the Earth plate, connected to galvanized earth strip 25mm x 4mm upto 7.50 m with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel including excavation, earth work, returning filing, removal of extra soil, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) chamber with RCC cover (1:2:4) type B0 (using 12.5mm graded crushed stone aggregate) 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe upto 7.50 m , funnel with wire mesh, watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.50m including Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification complete all as specified and directed.Note (i)Rate quoted shall be inclusive of earth work (Excavation, returning filling and removal) complete. |
| 30 | Demolition of Cement concrete (Unreinforced) of any description in ground floors and pavings not exceeding 75 mm thickness (below or above ground level) complete all as specified and directed. |
| 31 | M&L for 75 mm thick plain cement concrete (1:3:6) type C-2 (using 40mm graded stone agg) as in flooring/plinth protection/Hard standingfinishing concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 32 | M&L for servicing,cleaning ,overhauling of filter press all as specifried and directed by eng in charge.Note: Spare Parts will be measured and paid separetely under respective items of BOQ. |
| 33 | Supply, installation, testing & comissioningin replacement offilter press feed pumps monoblock type of capacity 2 HP complete all as specified and directed by Engr-in-charge.Note : Old motor shall be deposited to MES store yard |
| 34 | S&F in replacement of filter press cloth as per site requiremnt complete all as specified and directed by Engr-in-charge. |
| 35 | S&F in replacement ofPower contactor three phase 415 volt, 50 Hz,MNX A1 type model of L&T make complete all as specified and as directed. |
| 36 | S&F in replacement ofPower contactor three phase 415 volt, 50 Hz,MNX A2 type model of L&T make complete all as specified and as directed. |
| 37 | S&F in replacement of relay of capacity 1.5 - 2.5A, complete all as specified and directed by Engr-in-charge |
| 38 | S&F in replacement of MCCB FP, 415V, Adjustable type 160 Amp 36 KA complete all as specified and as directed. |
| 39 | Material and Labour for 3 core PVC insulatedflexible copper conductorcable of size 2.5 sqmm 1100 volt grade andPVCinsulated 3 way complete all as specified and as directed. |
| 40 | Supply & fixing, testing and commissioning in replacement of MCB TP 240 volt 25 - 63 Amp capacity having C-curve characteristics connected with suitable lugs fixed in repairscomplete all as specified & directed. |
| 41 | Supply only Alum complete all as specified and directed. |
| 42 | Supply only H2SO4 (Sulphuric Acid) all as specified and directed. |
| 43 | Supply only Sodium meta bi sulphate (Na2S2O5) all as specified and directed. |
| 44 | Supply only Caustic soda all as specified and directed. |
| 45 | Supply only Sodium hypochloride all as specified and directed. |
| 46 | Testing of effluent watermonthly from authorized NABL & BIS recognised lab and testing report to be submitted to Engineer-in-charge all as specified and directed. Testing paramaters shall include PH value, TSS, Oil & grease, SO4, PO4, Chromium hexavalent, Total chromium, ammonical nitroges |
| 47 | Note : For item No. 1 to 45 it shall be deemed that bidders have visited the site and checked the specification of all items before quoting, the items required have to be supplied as per existing specification & make available at site. |