| 1 | Supply, replacement and testing of the following MCB / RCCB on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2). |
| 2 | 6-32 Amps SP MCB (Type-C) |
| 3 | 6-32 Amps DP MCB (TYPE-C) |
| 4 | 40-63Amps, FP MCB (TYPE-C) |
| 5 | 125 Amps FP MCB (Type-C) |
| 6 | RCCB DP 25A sensitivity 30mA,TYPE AC |
| 7 | RCCB DP 40A sensitivity 30mA, TYPE AC |
| 8 | RCCB FP 40A sensitivity 30mA, TYPE AC |
| 9 | RCCB FP 63A, 300 mA sensitivity Type AC |
| 10 | RCCB FP 40A, 300 mA sensitivity Type AC |
| 11 | Supply, replacement and testing of following Switches /Bell push / Sockets / Plug top etc. as per the detailed specification and as directed by Engineer-in-charge.(Refer Sec VI (MNC), Clause No.5). |
| 12 | 1 No 10A One Way Switch on modular plate and termination of wires to the switches. |
| 13 | 1 No 10A Two WaySwitch on modular plate and termination of wires to the switches |
| 14 | 1 No 10A Bell PushSwitch on modular plate and termination of wires to the switches |
| 15 | 1 No 16A One Way Switch on modular plate and termination of wires to the switches. |
| 16 | 1 No 16A Two Way Switch on modular plate and termination of wires to the switches. |
| 17 | 1 No 6A 3 Pin Shuttered Type Socket heavy duty on modular plate and termination of wires to the switches. |
| 18 | 1 No 6/16A 3 Pin combined shuttered type Socket heavy duty on modular plate and termination of wires to the switches |
| 19 | 1 No 20 Amp Motor starter Switch on modular plate and termination of wires to the switches. |
| 20 | 1 No 16A 3Pin heavy duty plug top with indicator and termination of wires to the switches |
| 21 | 1 No 6A 3 pin duty plug top with indicator and termination of wires to the switches |
| 22 | 1 Modular dummy plate |
| 23 | One/Two module Modular front cover plate |
| 24 | 3 Module Modular front cover plate |
| 25 | 4 Module Modular front cover plate |
| 26 | 6 Module Modular front cover plate |
| 27 | 8 Module Modular front cover plate |
| 28 | 12 Module Modular front cover plate |
| 29 | 1No Geyser Indicator and termination of wires to the switches. |
| 30 | 1No 20 Amps SP C MINI MCB suitable in modular plate and termination of wires to the MCB. |
| 31 | 1No 20 Amps Electronic Key Tag + Key card in modular plate and termination of wires to the key control tag. |
| 32 | Supply, replacement and testing of following Lamp holders suitable for various type of luminaries as per the detailed specification and as directed by Engineer-in-charge |
| 33 | Fancy Type Angle / Batten Holder |
| 34 | Supply, replacement and testing of the following electrical accessories / control gearsas per the detailed specification and as directed by Engineer-in-charge.(Refer Sec VI (MNC), Clause No.12). |
| 35 | Bi-Pin Twist Lock Lamp Holder suitable for 28/36/40 Watts Fluorescent Lamps. |
| 36 | Universal Starter for 20/40 Watts Fluorescent Lamp as per Cat. No.S-10. |
| 37 | Electronic ballastSuitable for 1 X 36 Watts Fluorescent fitting. |
| 38 | Electronic ballastSuitable for 1 X 18 Watts Fluorescent fitting. |
| 39 | Supply, replacement and testing of 18 W Ultra violet lamp (ACTINIC) suitable for flying insect controller equipment and working voltage is 240V AC as per the detailed specification and as directed by Engineer-in-charge. |
| 40 | Supply and replacement of following Calling bells as per the detailed specification and as directed by Engineer-in-charge. |
| 41 | Calling bell - Ding Dong type |
| 42 | Calling bell - Musical chime type |
| 43 | Supply, replacement and testing of 9 inches Gong Bell as per the detailed specification and as directed by Engineer-in-charge. |
| 44 | Supply, replacement and testing of63 Amps, 3 Pole MCCBas per the detailed specification and as directed by Engineer-in-charge. |
| 45 | Supply and Embedment of 50mm Deep, Square / Rectangular Concealed type and GI double earthed modular metal boxes of the following types and as specified in RCC/Brick/Concrete Block Masonry with finishing and making good as per the detailed specification. (Refer Sec VI, Clause No.15.12). |
| 46 | ONE/TWO Module |
| 47 | THREE Module |
| 48 | FOUR Module |
| 49 | SIX Module |
| 50 | Supply, replacement of following sizes of Surface Mounting Plastic Boxes as per the detailed specification. (Refer Sec VI, Clause No.15.6). |
| 51 | Surface Mounting Plastic Boxes 1/2 Module |
| 52 | Surface Mounting Plastic Boxes 3 Module |
| 53 | Surface Mounting Plastic Boxes 4 Module |
| 54 | Surface Mounting Plastic Boxes 6 Module |
| 55 | Surface Mounting Plastic Boxes 12 Module |
| 56 | Wiring for lights / fans /sensors/ Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18) |
| 57 | Wiring with 1 Run of 1.5 Sq.mm Copper wire |
| 58 | Wiring with 1 Run of 2.5 Sq.mm Copper wire |
| 59 | Wiring with 1 Run of 4 Sq.mm Copper wire |
| 60 | Wiring with 1 Run of 6 Sq.mm Copper wire |
| 61 | Supply, replacement, testing and commissioning of the following LED Luminaires of suitable wattage as per the detailed specification and as directed by the Engineer-in-charge. (Refer Sec VI, Clause No.16.0). |
| 62 | 6W (Max), 700 lm output, 6500K, IP 66 Protection LED Bulkheadwith Aluminium die cast housing and polycarbonate diffused cover suitable for surface mounting. |
| 63 | 12W (Max), 1200 lm output, 6500 K, 600 mm long, LED batten with extruded Aluminium housing, suitable for Ceiling and Wall mounting. |
| 64 | 18W (Max), 2000 Im output, 6500K, 150mm dia size, recess mounting LED Luminaires with aluminium dia cast housing. |
| 65 | 15W (Max),1600 lumen output, 6500K, square /round type, LED Luminaires with polycarbonate material housing, suitable for surface mounting. |
| 66 | 36W (Max), 3600 lm output, 6500 K, 600mm x 600mm Recessed mounting type LED Light with CRCA housing suitable for 2 x 2 grid false ceiling. |
| 67 | 36W (Max), 4600 lm output, 5700 K, 595mm x 595mm surface mounting type LED Light. |
| 68 | 29W (Max),4000 lm output, 6500 K, 1200 mm long, LED batten withCRCA housing, suitable for Ceiling, Wall and Downrod mounting. |
| 69 | 17W (Max), 2000 lm output, 6500 K, 1200 mm long,LED Batten with CRCA housing, suitable for ceiling, wall and downrod mounting. |
| 70 | 22W (Max), 2200 lm output, 6500 K, 1200 mm long,LED Batten with Aluminium housing, suitable for ceiling and wall mounting. |
| 71 | Replacement of fluorescent lamps with LED Lamps including supply of 20W, 4 feet, 25mm dia, LED tube with built-in ballast (CG) or Equivalent and required rewiring inside the luminaires as per the detailed specification enclosed. (Refer Sec VI (MNC), Clause No.12.0). |
| 72 | Aviation obstructing LED lighting luminaires made out of polycarbonate body. |
| 73 | Tracing and rectification of defects in the Electrical installation in residential and public buildings as per the detailed specification and as directed by Engineer-in-charge. (Refer Sec VI (MNC), Clause No.4.0). |
| 74 | Replacement, testingandcommissioning of electrical components such as switch /socket / Ballast / Holder / Modular plates and Lamps etc, as per the detailed specification and as directed by Engineer-in-charge.Note:- Required Electrical component will be issued at free of cost cited above as applicable by the Department. |
| 75 | Preventive Maintenance of Bus bar trunking systems as per the detailed specification and as directed by Engineer-in-charge. |
| 76 | Preventive Maintenance of G+2 Stair case / Tower building Energy Meter Distribution Board (EMDB) as per the detailed specification and as directed by Engineer-in-charge. |
| 77 | Preventive Maintenance of 3 PhaseEnergy Meter Distribution Board (EMDB) in Residential building (Type V E) as per the detailed specification and as directed by Engineer-in-charge. |
| 78 | Preventive Maintenance of 8/12 Way 16/32/63 Amps MCB Power and Lighting Distribution Boards located in various public buildingsas per the detailed specification and as directed by Engineer-in-charge. (Refer Sec VI (MNC), Clause No.17.3). |
| 79 | Carrying out healthiness check of RCCB, MCB in TPN/SPN 12/8/6 way DB including checking of earth continuity of the distribution system at Type B / C / D / E / SA type Residential quarters as per the detailed specification and as directed by the Engineer-in-charge.(as per section-VI(MNC), clause No: 17.3) |
| 80 | Carrying out Full House Maintenance in various types of Residential buildings as per the detailed specification and as directed by Engineer-in-charge. |
| 81 | Full House Maintenance of Type B / C / SA type Residential Quarters (Entire House) |
| 82 | Full House Maintenance of Type D / E Residential Quarters (Entire House) |
| 83 | Cleaning of EMDB, MCB DB, Fuse DB and luminaries located in various buildings as per the detailed specification and as directed by Engineer-in-charge. (Refer Sec VI (MNC), Clause No.15). |
| 84 | Cleaning of G+2 Staircase, Tower block, Shopping center EMDBs. |
| 85 | Cleaning of V - E Type quarters EMDBs. |
| 86 | Cleaning of 8/12 Way 16/32/63 Amps Fuse / MCB Power and Lighting Distribution Boards. |
| 87 | Cleaning of luminaries located in various buildings. |
| 88 | Identification and rectification of shunt or series fault in lighting or power circuit wiring in building as per scope of work (Refer Sec VI (MNC), Clause No.4). |
| 89 | Minor fault |
| 90 | Major fault |
| 91 | Supply and Installation of 25 X 12 mm size of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29) |
| 92 | Supply, installation, testing and commissioning of 4 module plate with 20 A starter, 16 A socket heavy duty and 16 A plug top with indicator on already embedded metal box as per detailed specification and as directed by Engineer-in-charge. |
| 93 | Wiring for AC point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits or Trunking as per the detailed scope of work, including supply of2 Runs of 4Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18) |
| 94 | Painting of415V Switchboards, Cubicle switch boards having number of vertical sections up to 3,with One coat of synthetic enamel Paint including supply of paints and required consumables as per detailed specification and as directed by Engineer-in-charge.(Refer Sec VI (MNC), Clause No.3). |
| 95 | Supply and Installation of laminated Hylam sheet of 3mm thickness over the boxes and as per the detailed specification. |
| 96 | Excavation in hard soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2) |
| 97 | Supply and replacement of following heater coils / thermostat as per the detailed specificationand asdirected by the Engineer-in-charge. (Refer Sec VI (MNC), Clause No.13). |
| 98 | 230V, 1/2 kW, Single phase Heater coil suitable for BAIN MARIE/Geyser. |
| 99 | 230V, 3kW, Single phase, Heater coil suitable for DOSA TAWA / IDLI BOILER / Instant water heater etc. |
| 100 | 240 Volts, 16 Amps,50 Hz. Thermostat with adjustable Temperature Range 20 - 80 degree Centigrade. |
| 101 | Maintenance and Servicing ofRice/Idlyboiler, Bain maries andHot Plates, including contacts installed in kitchen as per the detailed scope of work and as directed by the Engineer-in-charge. (Refer Sec VI (MNC), Clause No.13). |
| 102 | Supply and replacement of panel LED indication lamp Dia \"22.5\"mm, various colours suitable for various operating voltages from 24 V up to 240 V AC/DC. (Refer sec VI (MNC), Clause No. 12) |
| 103 | Colour : Red/ Yellow/ Green/ Amber |
| 104 | Colour: Blue |
| 105 | Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and1 coat primer & 2 coats synthetic enamel painting and including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11). |
| 106 | Supply and replacement of panel knobs as per the detailed specification |
| 107 | Supply and replacement of LT danger board as per the detailed specification |
| 108 | Supply and replacement of Energy meter cover as per the detailed specification. |
| 109 | Supply and replacement of 8SWG copper wire in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8) |
| 110 | Supply, transportation, installation, testing and commissioning of the Occupancy & day light PIR sensor suitable for lighting load of 500W and coverage 7.0 mtr diameter. The unit Shall have provision to adjust ON time as well as day light level for switching ON as directed by the Engineer-in-Charge. (Refer Sec VI, Clause No.16.3) |
| 111 | Supply and painting One coat on metallic surfaces of electrical equipment and other required surface at all levels using Synthetic enamel Paint (Asian or approved brand, colour and manufacturer) to give an even shade including preparation of the surfaces, scaffolding complete all as per specifications and as directed by the Engineer-in-Charge. (Refer Sec VI (MNC), Clause No.3). |
| 112 | Supply, transportation, replacement, testing and commissioning of 3 core 1.5 Sq.mm PVC insulation flexible wire as per the detailed specification. |
| 113 | Supply, transportation, replacement, testing and commissioning of 3 core 2.5 Sq.mm PVC insulation flexible wire as per the detailed specification. |
| 114 | Electrical Safety Verification (Inspection and Testing) as per the Scope mentioned in accordance with National Electrical Code of India 2023 / IS 732 / IS17512standards using Qualified Third Party testing agency as per the detailed specification. |
| 115 | PCC Panel with Incoming&outgoing Feeders. |
| 116 | Hospital Pump Room incoming & outgoing. |
| 117 | LDP Incoming & Outgoing. |
| 118 | EM LDP Incoming & Outgoing. |
| 119 | SMDB Incoming & Outgoing. |
| 120 | LDB Incomer only. |
| 121 | ELDB Incomer only. |
| 122 | PDB Incoming & Outgoing. |
| 123 | ACDB Incoming & Outgoing. |
| 124 | EPDB Incoming & Outgoing. |