| 1 | Material and labour for conducting ‘B’ check ofDG sets of capacity 62.5 KVA to carry out following maintenance/servicing, complete all as specified and as directed :-(i) Change of diesel filter/oil filter,top up/replacement of engine oil, coolent if required.(ii) Check and clean engine, alternator battery,instrument panel, elect panel, Timer, Contactors ,Meters and others etc.(iii) Tightening of all nuts& bolts of DG set and its accessories.(iv)Check for any diesel lekage from any point and rectify if observed.(v) Check and adjust fan belt tension, replace the fan belts if found damaged.(vi) Check leakage of smoke from exhaust system/silencer,Repair if required.(vii)Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order (viii)Check and tighten the AVM pads nuts and bolts,change AVM pads if found damaged.AVM to be provided by contractor.(ix)Check exhaust pipe,flange and lagging Repair if found damaged. (x) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.(xi) Checking of all hoses and cleanup,change/tighten if required. (xii)Checking of all hoses and cleanup if required. Also changing air filter elements,if required. (xiii)Oiling,Greasing and checking for proper & smooth functioning. etcand refitting, testing on load complete(xiv) Repair / Calibration of Injector complete all as specified and directed by Engr-in-Charge. (xv) Overhauling and testing of governor assembly including machine work complete all as specified and directed .(Xiv) Replacement of Emergency push button if required. cleaning of DG set complete using cotton waste, repalcement of u/s rope of exhaust piping(Note 1. :-Rate forfor minor spare partslikeLimit Switch for emergency push button , Gasket, , cleaning of Radiator, replacemnt of fuel pipe, cleaning of Nozzle, tapit setting included in the quoted rates against each capacity.2. Ratefor Major spare parts and coolent required for replacement will be measured and paid separately under respective item of schedule. Job Work will be repeated in every 3 months during period of contract |
| 2 | All as per item No 01 here in above but DG Set 82.5 KVA to160 KVA, complete all as specified and as directed. |
| 3 | All as per item No 01 here in above but DG Set 250 KVA, complete all as specified and as directed. |
| 4 | All as per item No 01 here in above but DG Set 1000 KVA, complete all as specified and as directed. |
| 5 | M&L for writing MESnumbers onDG set with super enamelled synthetic paint ofany clour including digits and alphabets all as directed including withletterheight not less than of75 mm all as directed.Note: Colour of letters andback ground is as dired by the Engineer In charge. |
| 6 | Supply only air filter for following capacity DG set complete all as specified and as directed. Note : Number of/ set ofAir Filter varies depend on Capacity Contractor has to repalce Complete set of Filter as directed and considerd as une unit. |
| 7 | DG set of capacity up to62.5 KVA |
| 8 | DG set of capacity up to82.5KVA to160 KVA |
| 9 | DG set of capacity250 KVA |
| 10 | DG set of capacity 1000 KVA |
| 11 | Supply only fuelfilter kitfor following capacity DG set complete all as specified and as directed. Note : Number of/ set ofFuel filter varies depend on Capacity Contractor has to repalce Complete set of Filter as directed and considerd as une unit. |
| 12 | DG set of capacity up to62.5 KVA |
| 13 | DG set of capacity up to82.5KVA to160 KVA |
| 14 | DG set of capacity250 KVA |
| 15 | DG set of capacity 1000 KVA |
| 16 | Supply only oil filter kitfor following capacity DG set complete all as specified and as directed. Note : Number of/ set ofOil filtervaries depend on Capacity Contractor has to repalce Complete set of Filter as directed and considerd as une unit. |
| 17 | DG set of capacity up to62.5 KVA |
| 18 | DG set of capacity up to82.5KVA to160 KVA |
| 19 | DG set of capacity250 KVA |
| 20 | DG set of capacity 1000 KVA |
| 21 | Supply and fix in replacement of V-beltcomplete set suitablefor following capacity DG set complete all as specified and as directed. |
| 22 | DG set of capacity up to62.5 KVA |
| 23 | DG set of capacity up to82.5KVA to160 KVA |
| 24 | DG set of capacity250 KVA |
| 25 | DG set of capacity 1000 KVA |
| 26 | Supply and fix in replacement of Radiator water inlet hose suitablefor following capacity DG set complete all as specified and as directed. |
| 27 | DG set of capacity up to62.5 KVA |
| 28 | DG set of capacity up to82.5KVA to160 KVA |
| 29 | DG set of capacity250 KVA |
| 30 | DG set of capacity 1000 KVA |
| 31 | Supply and fix in replacement of Radiator water outlethose suitablefor following capacity DG set complete all as specified and as directed. |
| 32 | DG set of capacity up to62.5 KVA |
| 33 | DG set of capacity up to82.5KVA to160 KVA |
| 34 | DG set of capacity250 KVA |
| 35 | DG set of capacity 1000 KVA |
| 36 | Supply and fix in replacement of Thermostat elementsuitablefor following capacity DG set complete all as specified and as directed. |
| 37 | DG set of capacity up to62.5 KVA |
| 38 | DG set of capacity up to82.5KVA to160 KVA |
| 39 | DG set of capacity250 KVA |
| 40 | DG set of capacity 1000 KVA |
| 41 | Supply and fix in repalcement self starter and 24 Voltfor any make and capacitysuitable for existing DG set installed include completetesting and commissioning as directed |
| 42 | Supply and fix in repalcement self starter and 12 Voltfor any make and capacitysuitable for existing DG set installed include completetesting and commissioning as directed |
| 43 | M & L for Dismantling the weak self starter 24 Volt motor of capacity & make as taken out mentioned above , segragating serviceable and semi/unserviceable parts , cleaning serviceable parts , drying, lubricating. Reassembling the self starter motor with cleaned serviceable parts along withrepalcement of old U/s parts likes coil etcparts as below and testing complete as directed by EIC:- |
| 44 | Supply and replacement coolentPre-mix ready-to-use coolant for DG set of capacity 35 Kva to 1000 KVA as per existing suitable for Make and Type of DG set Installed complete all as specified and as directed. |
| 45 | Supply and replacementEngine oilfor DG set of capacity 35 Kva to 1000 KVA as per existing suitable for Make and Type of DG set Installed complete all as specified and as directed. |
| 46 | S & F Power Pack, industrial type,150 AH, 12 Volt ,25 Plate, allong with copper lead and clamp.Make: Exide/Amaron/Euivalent |
| 47 | S & F Power Pack, industrial type,180 AH, 12 Volt,25 Plate, allong with copper lead and clamp.Make: Exide/Amaron/Euivalent |
| 48 | S & F in replacementFuel injection pump/PT pump of following rating DG setsincluding dismanting the old fuel injection/ PT pump,complete includingcalibration, testing complete on computerised testing if required forequipment all as directed by Engr-in-Charge. |
| 49 | DG set of capacity up to62.5 KVA |
| 50 | DG set of capacity up to82.5KVA to160 KVA |
| 51 | DG set of capacity250 KVA |
| 52 | M & L for diamatling of alternator from its mounting by unscrewing the nut & bolts 3 Phase 440V capacity 35 to 62.5 KVA, including the alternatorCleaning the whole assy of alternator, Replace the commutator, carbon brush, Rectifier, Slip Rings, Slip ring end bearing, Drive end bearing etc and re-assebling the all parts and mounted the alternator on its same place and do the connection as previous complete all as specified and directed by Engr-in-Charge.Note : Copper winding wire if required for rewinding will be measured and paid seperately under respective item. |
| 53 | -ditto- all as per item No 21 in here in above but capacity 82.5 KVA to 250 KVA |
| 54 | -ditto- all as per item No 21 in here in above but capacity 1000KVA |
| 55 | M & L for replacement of AMF Panel controller suitable of DG Set of capacity 35 KVA to 62.5 KVA |
| 56 | M & L for replacement of AMF Panel controller suitable of DG Set of capacity 82.5 KVA to 250 KVA |
| 57 | M & L for replacement of AMF Panel controller suitable of DG Set of capacity 320 KVA to 1000 KVA |
| 58 | M & L for servicing and repair toautomatic main failure (AMF) panel of capacity 15 to 250 KVA installed at various locations by carrying out the following repair work:(a) Disconnecting the incoming power supply and taking out and dismantling the electrical components from the AMF panel of any make and replacement of unserviceable/burn out/defective parts and cleaning/servicing entire interior and exterior serviceable parts and refixing the same in existing position including connections, testing and commissioning etc complete all as specified and directed by the Engr-in-Charge.(Note: (i) Rate include repalcement of small piece of burned or U/s control wire (Max up to 5.0 Mtrs),LED typeindicating lamps , HRC fuse for control CKts Max of 5 Amp Ratingselector switch as required at site for complete functioning of Panel(ii) The Major spare/partslike Contactor, ATS , CT\"s shall be measured and paid seperately asunder respective items here-in-below. |
| 59 | All as per item no 27 but for DG set ofcapacity 1000KVA |
| 60 | Supply and fix in replacement 4 pole power contactors Type MCX of rating up to50 Amp with suitable coil voltage as per site requirement /make /Base size as match with existing complete all as per Make : L &K /C & S / Siemens. |
| 61 | Supply and fix in replacement 4 pole power contactors Type MCX of rating 63 Ampwith suitable coil voltage as per site requirement /make /Base size as match with existing complete all as per Make : L &K /C & S / Siemens. |
| 62 | Supply and fix in replacement 4 pole power contactors Type MCXof rating 100 Amp with suitable coil voltageas per site requirement /make /Base size as match with existing complete all as per Make : L &K /C & S / Siemens. |
| 63 | Supply and fix in replacement 4 pole power contactors Type MCX of rating200 Amp with suitable coil voltageas per site requirement /make /Base size as match with existing complete all as per Make : L &K /C & S / Siemens. |
| 64 | Supply and fix in replacement 4 pole power contactors Type MCXof rating 360 Amp with suitable coil voltageas per site requirement /make /Base size as match with existing complete all as per Make : L &K /C & S / Siemens. |
| 65 | Supply and fix in repairs Automatic Battery Charger SMPS based, 12V DC suitable for AMF panel 35-250 KVA complete all as specified and directed. |
| 66 | Supply and fix in repairsAutomatic Battery Charger SMPS based, 24V DC suitable for AMF panel 35-250 KVA complete all as specified and directed. |
| 67 | Supply and fix in replacement Automatic voltage regulator suitable for any make and capacity from 35 KVA to 160 KVA complete all as specified and directed. |
| 68 | Supply and fix in replacement Automatic voltage regulator suitable for any make and capacity 250 KVA complete all as specified and directed. |
| 69 | M & L for painting of DG set of following capacity complete by removing the existing treatment and applytwo coat of synthetic enemel paint over one coat of red oxide primer using spray painting machinecomplete all as specified and as directed by Engineer-in-Charge. |
| 70 | DG set of capacity up to62.5 KVA |
| 71 | DG set of capacity up to82.5KVA to160 KVA |
| 72 | DG set of capacity250 KVA |
| 73 | Supply,install,test and commissioning of out door typedouble doorAMF panel made out of 3.0 mm thick CRCA sheet , made out from CPRI Approved firm, totally enclosed weather dust and vermin proof as per ISwith frontopening suitablelocking arrangement having copper bus bar of 600 Amp capacity for RYB andneutral and insulated with insulators,including connecting incoming and outgoing cables, with necessary PCC 1:3:6 in foundation and made out of 50 X 50 X 6 mm angle iron grouted at groundand30 cm above from ground level Comprising the followingall as specified and as directed by the engineer - in-charge. Note: Cost includes necessary internal wiringfor meters , CT\"s as required for operation of AMF panel / ATS ,indication lamps,etc and Rigid copper bus bar connections from bus bar to MCCB terminalsand suitable size copper wire for control wiring and Indicating lamps complete all asdirected.(a) MCCB 320 Amp, 36 KA -02 Nos(b) ATS 400 Amp with necessary power pack suitable rating ,necessary Auxillary contactors as required site for smooth operation of ATS- 01 Nos(c) Indicating lamp , RYB forMain and DG set Supply - 01 Set(d) Indicating lamp for Load on DG or Load on Main - 01 Set (e) Led type Dual SourceMulti Function Meter- 01 Nos (f)Control wiring from ATS to DG set /DG set to ATS for Operation of AMF panel , Control Wiring for Battery charger from Panel Board - 01 Job Note: Rate include necessary control wiring from DG set to to AMF panel/ATS forAuto manual operation |
| 74 | Supply,install,test and commissioning of out door typedouble door , AMF panel made out of 3.0 mm thick CRCA sheet , made out from CPRI Approved firm, totally enclosed weather dust and vermin proof as per ISwith frontopening suitablelocking arrangement having copper bus bar of 200 Amp capacity for RYB andneutral and insulated with insulators,including connecting incoming and outgoing cables, with necessary PCC 1:3:6 in foundation and made out of40 X 40 X 5.0 mm angle iron grouted at groundand30 cm above from ground level Comprising the followingall as specified and as directed by the engineer - in-charge. Note: Cost includes necessary internal wiringfor meters ,CT\"s as required for operation of AMF panel / ATS ,indication lamps,etc and Rigid copper bus bar connections from bus bar to MCCB terminalsand suitable size copper wire connectionBus to MCB connections complete all asdirected. Make: As per CPRI approved manufacturer(a) MCCB 100 Amp,16 KA -02 Nos(b) ATS125 Amp with necessary power pack suitable rating ,necessary Auxillary contactors as required site for smooth operation of ATS- 01 Nos(c) Indicating lamp , RYB forMain and DG set Supply - 01 Set (d) Indicating lamp for Load on DG or Load on Main - 01 SetNote: Rate include necessary control wiring from DG set to to AMF panel/ATS forAuto manual operation |
| 75 | M & L for comprehensive maintenance of Solar PV power plant system of capacity 100 KW ,and15 KWby providing servicesfor monthly checkingof complete solar panel , checking of all electricalconnections, inverter ,Meters etcincluding renewal of sub scription charges fordata logging system ,including reneval of one internet connection with high spped data broad bandof unlimitted data from any of service provider working inside the INS Mandovi , data speedUp dation of Mobile Application ,complete for for ensuring the uninterrupted services of Solar power plant installed at INS Mandovi complete for following all as specified and as directed.Note:The cost of instalation of internet connection cable,Router , Wifi Modem is deemed to be included in Unit Rate. Note:(i) Repair / replacement of solar modules, mechanical structure of solar module, Major electrical workof ON grid solar power plant upto Inverter/Meter is measured and paid seperately.(ii) The quoted rate is for both 100KW and 15KW treated as each job per month for the payment purpose. |
| 76 | Supply and fix in replacementpolycrystaline 330 Wp solar panel including necessary connection with existing Inverter , junction box complete all as specified and as directed. |
| 77 | M & L for cleaning of solar power plantof capacity 100 KW using pressure water pump/pressure washer,brushes, necessary cleaning tools, soft bristle brushes, necessary soap /detergent suitable for cleaning of solar panel with out damaging the solar panels |
| 78 | M & L for cleaning of solar power plantof capacity 15 KW using pressure water pump/pressure washer,brushes, necessary cleaning tools, soft bristle brushes, necessary soap /detergent suitable for cleaning of solar panel with out damaging the solar panels |
| 79 | M & L for checking of earth resistance after disconnecting the earthing lead from test point by using Digital/Analog earth resistance and recording the earth resistance value in periodical interva/ As directed by Engineer in charge to earth pit at OTM and Married Accn area complete all as specified Note: Rate include the M & L for checking the earthing complete including Technician , Necessary Tools for checking complete all as directed. |
| 80 | M & L earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with Copper strip 20 X 3 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mmthick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including copper - sulphate e all as shown in electrical plate No 5 and connected to earthing test point all as specified and indicated including testing on completion and marking of description of earthing on GI plate grouted on the earth chamber complete all as specified and directed Note : ( i) The Value of Earthing Should be not less than Five Ohm.. |
| 81 | Supply and installation of maintenance free earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3 m length, having a diameter of 25 mm with copper coating thickness of 250 microns with fault current withstand capability of 30 KA rms value of 1 second and I peak of 80 KA (OBO Article type 25 3000 CCER), tested as per IEC 62561-2, meets the requirement of IS-3043 & IEC 60364-5-54, tested in CPRI for short circuit with standing capacity, OBO article type OEC 25 Earth conductivity enhancing mineral compound to be used as a backfill compound for earth electrodes; highly conductive in all weather conditions is used for improving the soil conductivity.The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod.The material should have a resistivity less than 0.2 ohm -m.It should be free from hazardous substances. The mineral compound is required to have minimum 25 kg of the total composite, Universal clamp (OBO Article Type 25 25 RTC) made of SS 304 for clamping, Polypropylene & polyethylene (OBO type UFE) Earth electrod inspection chamber with heavy duty cover should be used to cover the earth rod.The dimension shall be 170mm x 170 mm x 190 mm with a weight bearing capacity of 50 KN. including provision and laying copper flat 20 x 3 mm thick from earth electrode to test joint directly in ground as required cross sectional area. Make : OBO / ABB / AshlokNote: (i) The Chemical earthing shall be done through the OEM /Authorised rep / Authorised channel partner of OEM and , the Value of Earthing Should be not less thanOneOhm. |
| 82 | M&L for earthing with steel earth plate electrode 60×60cm.× 6mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to existing earth leadstripby means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 5 connected to earthing test point and and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all aroundthe earth electrode with funnel and 20mm bore galvanized iron watering pipe (light grade) wire mesh, copper lugs, complete in all respect,including galvanised iron strip of size25 x 4 mm as earth leadincluding 40mm bore (medium grade) galvanized iron pipe up to earthing test pointfor protection of earth lead complete as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion,and writing theearth resistance value on PCC pit with black paint complete all as specified and as directed. Note : ( i) The Value of Earthing Should be not less than Five Ohm..(ii) for Sl Item no46 to 48 : On Testing after completion if the desired earth Resistance is not obtained earthing will be redone at No extra Cost |
| 83 | S & F in replacementtest point terminal block made of phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws fixed to copper strip bracket fixed in MS box of of suitable sizeon wallascomplete all as specified and directed |
| 84 | S & F replacementCopper strip 20 x 3.00 mm with saddles and fixing screws etc. for roof conductors with rubber & bitumen washer & fixed to porcelain insulator, brazing of copper strips overlapping of not less than 10cm on wall for down conductor complete all as specified and directed |
| 85 | Supply and fixingreplacement porcelain vitreous white/brown/green spacers insulator of size 75mmx35mmx40mm height complete with one number galvanized iron stud bolts 6mm dia x 40mm long including nut & washers and two number galvanized iron fixing bolts of size 6mm dia and 50 mm long including washers and drilling holes for holding /foxomg aluminium strip/roof conductor as required including taking down the broken insulator complete all as specified and as directed by the Engineer-in-Charge. |
| 86 | M&L in replacement Tubes,lightgrade\" galvanised, with all fitting and fixed complete to walls and ceilings by flat iron clamp nuts bolts etc complete or laid in floors 40 mm dia complete all as specified and directed. |
| 87 | Supplying and fixing in repairs earth continuity conductor or main earthing lead of Galvanised iron wire of size 25 x 4 mmfixed onwall /inside the cable trench withfrom existing earth test point complete all as specified and as directed by the Engineer - in - Charge. |
| 88 | M & L for earthing pit in PCC (1:3:6) type C1 pre-cast RCC (1:2:4) type B-1 cover slab of size 300 x 300 x 50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size including 29mm bore GI light grade pipe for watering, funnel, wire mesh, necessary earth work in soft/loose soil all as shown in electrical plate No 4 of MES schedule Part I and testing and applying three coats of white wash on exposed surface of concrete complete including taking down old one, complete as specified and as directed. |
| 89 | Supply and fix in replacement power line SPD single pole + NPEof voltage rage Uc 320 V , 1 P +NPE complete with eclosure for fixing the SPD on wall including wiring using 4.0 SQ mm Single core multi stranded copper conductor with existing DB placedadjesenton wall comple all as specified and as directed.Make: OBO/ ABB/ Siemens |
| 90 | Supply and fix in replacement power line SPD 4 pole of voltage rage Uc 550 V ,4 polecomplete with eclosure for fixing the SPD on wall including wiring using 4.0 SQ mm Single core multi stranded copper conductor with existing DB placedadjesenton wall comple all as specified and as directed.Make: OBO/ ABB/ Siemens |
| 91 | M & L for putting Earth enhancement compound suitablefor high resistivity areato existingconvensional /chemical earth pit for enhansing the earth resistance value of earth pit complete all as specified and as directed.Make : OBO Article No - OEC 1 25 / Equivalent in ABB / Ashlok |
| 92 | M & L for copper conductor multistranded4.0 sqmm (Nominal area) single core cable FR,PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through PVC conduit medium dutyof suitable size not less than 20 MM dia fixed onwall/ceiling/ Cable trench with saddles for earthing connection from Earth test point to DB/Eqpt withcopper lugs 4.0 mm using brass bolts, nutsat both end complete all as specified. |
| 93 | Supply and fix inreplacementVolt meter 0-500 Volt , three phaseDigital type of size 96 X 96 Sq mm flush mounted casein existing panelincludingwiring from bus bar to volt meter terminals so as to match with the existing control wiring complete all as specified and as directed by the engineer - in-charge [Make: Neptune/ AEI/ Meco/ HPL/L & T] |
| 94 | Supply and fix inreplacementDigital Ammeter three phaseof size 96 X 96 Sq mm flush Mounted of following rangein existing panel with necessary wiring from CT to Ammeter and so as to match with existing control wiringcomplete all as specified and as directed by the engineer - in-charge.[Make: Neptune/ AEI/ Meco/ HPL/L & T] |
| 95 | Supply and fixinreplacementcurrent Transformer of50 /5 CT ratio,Indoor tape INsulated Ring typein existing panel in cludintg taking down old unserviceble CT\"s of any make /Ratingcomplete all as specified and as directed by the engineer - in-charge . [Make :Neptune /AE / Kappa] |
| 96 | Allas per the item no 61above but for CT ratio 100 /5 Amps . |
| 97 | Allas per the item no 61above but for CT ratio 150 /5 Amps . |
| 98 | Allas per the item no 61above but for CT ratio 400 /5 Amps. |
| 99 | Allas per the item no 61 above but for CT ratio 1500 /5 Amps |
| 100 | Supply and fixing in replacement MCCB in of followng ratingsin existing board connecting with proper sizelink set at incomming and out going cable connections and making necessary modification in existing panel as required complete allas specified and directed by EIC . Note: cost in clude taking downthe existing MCCB from panel board and incoming / outgoingcable and fix the new MCCB inposition atpanel board / incoming / outgoingcable connections of any size/ rating. |
| 101 | MCCB 63 to 100 Amp 4 pole 16 KA ; Make: Legrand / L & k /Havell\"s/C & S |
| 102 | MCCB 125Amp 4 pole 16 KA ; Make: Legrand / L & k /Havell\"s/C & S |
| 103 | MCCB 200Amp 4 pole 25KA Make: Legrand / L & k /Havell\"s/C & S |
| 104 | MCCB 250 Amp 4 pole 25KA Make: Legrand / L & k /Havell\"s/C & S |
| 105 | MCCB 320 Amp 4 pole 25KA Make: Legrand / L & k /Havell\"s/C & S |
| 106 | MCCB 400 Amp 4 pole 25KA Make: Legrand / L & k /Havell\"s/C & S |
| 107 | Supply only copper winding wire with supper enamelled copper wire of suitable gauge as per capacity/Rating of DG set alternator/field windingcomplete all as specified and directed by Engr - in - charge. |
| 108 | M & L for attending break downto existing DGof CApacity 35/40 KVA to1000 KVADG setset checking DG set Alternator and Prime mover , and AMF Panel complete all as specified for checking no supply/Break down fornecessary repair complete alla as specified. |