| 1 | Material and labour for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces in two layers (10mm thick 1st layer + 5mm thick finishing layer) as in walls, chajjas, fins, facia etc. any height mixed with liquid water proofing compound (for 5mm thick finishing layer only) @200 ml per 50 kg of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement including taking down old existing plaster complete all as specified and directed.Note: (i) Water proofing compound will be measured and paid separately(ii) Cost of scafolding, any height are deemed to be inclusive in the quoted rate. |
| 2 | Supply only liquid waterproofing compound |
| 3 | Material and labour for 10 mm thick rendering in cement mortar (1:6) onfair faces of brick work or concrete surfaces as in walls,finished even and smooth without using extra cement including taking down cement plaster of any description on brick or stone walls etc including racking out joints,hacking for key scrubbing down with water complete all as specified and directed. |
| 4 | Material and labour for 5 mm thick rendering in cement mortar (1:3) on concrete surface as in ceiling/chajja finished even and smooth without using extra cementincluding taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water complete all as specified and directed. |
| 5 | M & L for providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 6 | Material and labour for applying three coats of white wash on ceiling including preparation of new or previously untreated surfaces complete all as specified and directed. |
| 7 | M&L for preparation of new plastered surfaces of walls surfaces and applying two coats of oil bound distemper (any colour/tint)over a coat of primer complete all as specified and directed. |
| 8 | M&L for complete removal of existing treatment and preparation of old surfaces of walls and applying two coats of oil bound distemper (any colour/tint)over a coat of primer complete all as specified and directed. |
| 9 | M&L for preparation of old plastered surfaces of walls surfaces and applying one coats of oil bound distemper (any colour/tint)complete all as specified and directed. |
| 10 | M&L for preparation of new plastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 11 | M&L for complete removal of existing treatment and preparation of old plastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and as directed. |
| 12 | Material & Labour for preparation of old plastered surfaces of walls and applying one coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm complete all as specified and as directed. |
| 13 | Material and labour for preparation of old treated steel surface including trusses of any description exceeding 10cm width or girth and applying one coat of synthetic enamelled paint complete all as specified and directed. |
| 14 | Material and labour for preparation of old treated CGI roof sheet of any description exceeding 10cm width or girth and applying two coat of synthetic enamelled paint complete all as specified and directed. |
| 15 | Material and labour for preparation of old treated wood or wood based surface of any description including eaves board exceeding 10cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and directed. |
| 16 | Material and labour forobliterating old writing of any description, not exc 0.1 sqm with paint to match existing works complete all as specified and directed. |
| 17 | Material and labour for rewriting/repainting to existing writing letters or figures area not exc 0.50 sqm and height not exc 30 cm in block Roman, Italian or Indian letters including stops, comma, arrows, brackets, dashes etc on sign board (Black or yellow base) including two coats of oil paint over a coat white basesynthetic enamel paint complete all as specified and directed. |
| 18 | Material and labour forpreparation of old treated wood or wood based surfaces including truss of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tint and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 19 | Material and labour for preparation of old treated steel surface including truss of any description not exc 10cm width or girth and applying one coat of synthetic enamelled paint complete all as specified and directed. |
| 20 | Dismantling CGI/PPGI corrugated or semi corrugated sheets in wall cladding or roof coverings and hanger doors including re-fixing in same position the aluminium earthing strips after re-fixing/fixing of new sheets complete all as specified and directed. |
| 21 | S&F pre-painted galvalume aluminium zinc coating PPGL based corrugated/Trapezoidalsteel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 22 | S&F Pre- painted galvalume aluminium zinc coating PPGL based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, eaves board, fixed with self tapping screws complete all as specified and directed. |
| 23 | M&L for providing and fixing false ceiling of designer tile ivory/white painted (high pressure steam cured) of 4mm thick (as per IS: 14862) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms/sqm both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 15x32mm made of 0.3mm sheet 1200mm long spaced between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width including taking down old false ceiling board of any description alongwith rails and connecting items at any heights complete all as specified and directed. |
| 24 | M & L for 2nd class hard wood boarding 20mm thick, planed one side with butt joints, fixed with nails in any situation or as in eaves board (except flooring and skirting) including dismantling boarding, any description and thickness, fixed in any position with nails/screws complete all as specified and directed. |
| 25 | Material & labour for preparation of new wooden surfaces of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 26 | S&F 10 litres CapacityPVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets & flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern & fixing/connecting to pipes complete all as specified and directed. |
| 27 | Supply and fixed in repairs vitreous china squatting pan, Orissa pattern of size 580 mm x 440mm white withP or S trap, front or back inlet and integral foot rest (excluding flushing cistern and flush pipe) complete all as specified and directed. |
| 28 | S&F in repair wash hand basin, white, flat back of size 550 x 400mm excluding pillar taps but including waste coupling, waste pipe and bracket, etc.including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 29 | S&FVitrous china wash down water closet pan EWC, white including white plastic water closet seat & back with flat bottom and cover mild steel chromium plated or aluminium anodised high device (excluding flushing cistern and flush pipe) but including fixing bolt and necessary connection with existing pipes complete all as specified and directed. |
| 30 | S & F in repair Vitreous China bowl urinal flat back, size of 590x400x380mm (minimum), white, with grating and union for discharge pipe (excluding flushing cistern) including flushing pipe and outgoing pipes fixed complete all as specified and as directed. |
| 31 | Taking down eaves gutters, sewage lines andrainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swannecks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 32 | M & L for 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in floors complete all as specified and directed. |
| 33 | S & F 110 mm bore PVC (SWR) bends any radius with access door complete all as specified and directed. |
| 34 | S&F for 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal with access door including necessary scafolding any height complete all as specified and directed. |
| 35 | S & F 110mm bore, PVC (SWR) junction single (Single T) equal or unequal with access door including necessary scafoldingany height complete all as specified and directed. |
| 36 | Demolition of cement concrete(un-reinforced) of any description and in anypositionnot otherwise specifically provided for etc complete all as specified and directed. |
| 37 | M&L for treatment to sunken floor of Toilet/Bathroom as in following steps:-i)Top of RCC slab in sunken portion includingperipheral beams shall be plastered with 15mmthick in cement mortar 1 : 3 using approved waterproofing compound @ 3% by weight of cement finished even and smooth using extra cement,curved at the junctions. ii)Apply two coats of epoxy resin/polymer modified cementatious coating like brush bond of FOSROC/SIKA/Pedilite both on floor & beams.iii)Sunken slabs to be given 1:20 slope outward 25mm GI pipe spout with 300 mm projection beyondouter surface of wall shall be provided.iv)Water tightness of sunken portion to be tested by ponding with water for 72 hours. In case of even a slight mark of seepage, the portion to be treated and ponding shall be carried out again to confirm the water tightness of sunken slab. Note : No cutting in roof slab/beam shall be allowed for passing of CI/PVC pipes & fittings. The stage of water proofing to sunken slab shall be passed by Eng-in-charge/GE. |
| 38 | M&L for 25mm thick PCC 1:2:4 Type B-1 ( using 20 mm graded crushed stoneaggregate)as in floor (rough finished) complete all as specified and as directed. |
| 39 | M&L for PCC 1:5:10 Type E2 (using 40mm graded crushedstone aggregate) as in filling to sunken floorcomplete all as specified and directed. |
| 40 | Dismantling of floorhearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 41 | M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.Note: Screed bed shall be measured and paid separately. |
| 42 | M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.Note :- Backing coat shall be measured and paid separately |
| 43 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc., set and jointed in neat cement slurry andpointed in white or coloured cement to match complete all as specified and directed.Note: Screed bed shall be measured and paid separately. |
| 44 | M&L for glazed ceramic coloured /printed tiles of size 450x300x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles as in skirting, dado, etc. complete all as specified and directed. Note :- Backing coat shall be measured and paid separately |
| 45 | Material and labourfor 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying of floor tiles complete all as specified and directed. |
| 46 | M&L for 10 mm thick backing coat in cement mortar (1:3)for fixing tiles in vertical surfaces such as riser of steps, skirting, dados, etc complete all as specified and directed. |
| 47 | S&F in repairs 15mm dia Bib tap, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 48 | S&Fin repair 15 mm dia stop valve, fancy type, chromium plated and cup(concealed type), cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union & fixed complete all as specified and directed. |
| 49 | S&Fin repair 15 mm dia stop valve, fancy type, chromium plated, cast copper alloy, long shank, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union & fixed complete all as specified and directed. |
| 50 | S&F in repairs 15 mm dia pillar tap, fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and directed. |
| 51 | S&Fin repairs brass chromium plated shower rose 100mm size, including fixing to steel pipe or union complete all as specified and directed. |
| 52 | S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 53 | S&F in repair PVC connection pipe, 15 mm dia, 450 mm long with PTMT nuts complete all as specified and directed. |
| 54 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls etc complete all as specified and directed. |
| 55 | Taking up or down steel tubing 15mm diaand connections including cleaning for refixing or removal to store and S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. complete all as specified and directed. |
| 56 | Taking up or down steel tubing 20mm diaand connections including cleaning for refixing or removal to store and S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. complete all as specified and directed. |
| 57 | Taking down chowkats or frames not exceeding 1.50 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 58 | Supply and fix aluminium anodised (powder coated) ventilator frame (section for frame63.5 X 38.1X 1.20mm thick) with shutter(section for shutter 41 x 20 x1.2mm thick)(bottom half portion fixed and top half portion with louverincluding all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 4 mm thick frosted glass to aluminium frame work and louver using rubber gasket and fixed with stainless steel wire cloth of 0.36 mm dia and average width of aperture 1.40 mm outside vent with staple and suitable wall angle of size 25.4 x 25.40 x 1.1mm thick and fillets with screws and washers etc including Deco Grill of Model / Design No. DG 104 and 6.3mm thick etc. complete all as specified and as directed. |