| Sl. No. | Item Description |
| 1 | Taking out of ceiling/exhaust fan/Air circulator fan from AGE E/M store yard/Site and transport to reputed workshop for rewinding the fan starter with the same gauge of copper winding wire as well as number of turns and reassembling the fan after replacing the unserviceable spares like bushes, shafts, fasteners, bearings, capacitors and flexible cord for puttingfan in serviceable condition including refixing the sameafter carrying out necessary repairs to original place all as directed by Engineer-in-Chargeoffollowing sizes:- (Bushes, shafts, bearings, capacitors, flexible wires,painting etc. shall be measured and paid separately) Note:- Fans are to be collected on requirement basis by contractor/his Rep irrespective of Qty from GE (AF) Ambala Store Yardand Fan must be deposited to same store within seven Days. Failing which 100Rs/Day will be deducted from Workdone. |
| 2 | Ceiling Fan (1200/ 1400 mm) size of any make |
| 3 | Exhaust Fan of 230/300mm size of any make. |
| 4 | Exhaust Fan of 400/450 mm size of any make |
| 5 | Wall Fan Of Any Size/Any make |
| 6 | S&F In Repair of driver of BLDC Ceiling fan of existing size/type/make/model complete all as specified and as directed. |
| 7 | S&F in Replacement of capacitor 2.50/3.15/4.0 mfd capacity (condenser) of exhaust and ceiling fans complete all as specified and as directed. |
| 8 | S&F in replacement 3 core PVC flexible copper conductor cable(cord) of 0.5 Sqmm complete all as specified and as directed. |
| 9 | S&F GM bushes for ceiling/exhaust fans of various sizes complete all as specified and as directed. |
| 10 | S&F Screws for fan body/fan blade of Fan of any make/model complete all as specfied and as directed |
| 11 | S&FShaft for fan of any type/any size complete all as specified and as directed. |
| 12 | M&L for Lathe work/machine work for fitting/housing of in bottom/top cover of fans of any size/ type/ model complete all as specified and directed. |
| 13 | M&L for attending complaints of pressure pump installed to internal water supply line within 8 Hours after receiving complaints telephonically of low pressure or pump not working failing in this 100 Rs per day will be deducted, complete all as specified and as directed.Note:- cost of all T&P including ladder shall be deemed to be included in the quoted rate. |
| 14 | M&L forLathe work/machine work for fitting/housing in Pump of any size/ type/ model complete all as specified and directed. |
| 15 | S&F impeller made of brass suitable for any type of pressure pump complete all as specifed and as directed. |
| 16 | S&F in replacement Pressure pump Vessel for suitable of pressure pump of any make/model complete all as specifed and as directed |
| 17 | Taking old unserviceable PVC body air freshnerand supply and fixing PVC body air freshner 220/230 mm sweep single phase 230 volts including louvers and fixing arrangement as per site requirement complete all as specified and as directed. |
| 18 | S&F M.S. clamps for hanging ceiling fan with nuts, checknuts and bolts 2\" x3/8\" : 02 Nos. including rubber rings(reel) for hanging ceiling fans complete all as specified and as directed. |
| 19 | Taking down ceiling fan/exhaust fan for overhauling,oiling greasing etc and reassembling the same after necessary replacement of unserviceable parts like bush, capacitors, wire, bearing, etc. refixing the same with proper fitting of blades, clamps, split pin, etc. (Note : Bushes, shafts, bearings, capacitors, flexible wires,painting etc. shall be measured and paid separately) |
| 20 | M&L painting with two coats of white synthetic enameled paint after preparation of surface and marking MES No by black permanent marker of any type of ceiling fan complete all as specified and as directed.. |
| 21 | Supply & Fix ball bearing suitable for following ceiling/exhaust fans: |
| 22 | Ceiling Fanof any make/size of any make |
| 23 | Exhaust Fan of any make/size. |
| 24 | S&F in repalcement down rod of 20mm GI tubing medium grade for extension rod not exceeding 60 cm each for ceiling fans including cutting,threading and drilling holes etc complete all as specified and as directed. |
| 25 | Taking out/dismantling of oldunserviceable check valveofof pressure pump of capacity (0.5 to 1 HP) and supply and fixing of newcheck valve made of brass size 15/25/32 mm dia complete all as specified and as directed. |
| 26 | Taking down old unserviceable Auto cutand supply and fixing new auto cut (pressure release valve ) suitable for pressure pump of capacity 0.5 -1.0HPcomplete all as specified and as directed. |
| 27 | Taking out/dismantling of pressure pump of capacity 0.5 -1.0 HP atsite to reputed workshop for rewinding thepressure pump with the same gauge of copper winding wire as well as number of turns and reassembling the pump after replacing the unserviceable spares partlike bushes, shafts, fasteners, bearings, capacitors and copper wire for puttingpump in serviceable condition including refixing the sameafter carrying out necessary repairs to original place complete all as specified and directed Note :- Spare parts , rewinding work etc required for repairing the pump shall be deemed to be included in the quoted rate by contractor. |
| 28 | Taking down carefully aluminum point wiring (light, fan, socket or power) complete fittings such as switches, C/roses, Pendants DBs, sockets etc. including taking down carefully by unscrewing from boards/outlet/DBs/fittings such as switches, sockets, lamp holders, brackets, ceiling fittings bulkhead fittings, tube light fittings, fan regulator, electric meters, meter box any type etc as directed by Engineer-in-Charge. All the removed material will be handed over to the contractor under schedule of credit and making good to the disturbed surface by plastering and two coat of distamper, matching with existing .complete all as specified and directed |
| 29 | M & L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathedcable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 20mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 1.5 sqmm FRLS PVC insulatedunsheathedcable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following :- |
| 30 | One light/fan/ controlled by one switch 6 amp one way complete all as specified and as directed. |
| 31 | One 3 pin switch socket combination 6 amp on the independent board complete all as specified and as directed. |
| 32 | One 3 pin switch socket combination on same board with other switches complete all as specified and as directed. |
| 33 | One bell point controlled by one bell push complete all as specified and as directed. |
| 34 | All as described in BOQ srl Item No. 29.00 above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathedcable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and as directed. |
| 35 | M & L forpoint wiring on wall/ surfacewith 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathedcable 1100 volts grade drawn through and including PVC Casing cappingwith all accessories including provisining of 1.5 sqmm FRLS PVC insulatedunsheathedcable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete all as specified and directed. |
| 36 | One light/fan/ controlled by one switch 6 amp one way, complete all as specified and as directed. |
| 37 | One 3 pin switch socket combination on same board with other switches, complete all as specified and as directed. |
| 38 | One 3 pin switch socket combination 6 amp on the independent board, complete all as specified and as directed. |
| 39 | All as described above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathedcable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and as directed. |
| 40 | S&F in replacement ofswitch piano modular type 5 amp single pole flush type one way complete all as specified and directed. |
| 41 | S&F in replacement of switch piano modular type 15 amp single pole flush type one way complete all as specified and directed. |
| 42 | S&F in replacement of socket outlet modular type 3 pin 5 amp multi pin flush type complete all as specified and directed. |
| 43 | S&F in replacement ofsocket outlet modular type 6 pin 15 amp multi pin flush type complete all as specified and directed. |
| 44 | S&F in replacement ofmodular step type fan regulator electronic type 120 watt 2 module all as specified and directed. |
| 45 | S&F in replacement of modular cover plate with frame for 2 module complete all as specified and as directed. |
| 46 | S&F in replacement of modular cover plate with frame for 3 module complete all as specified and as directed. |
| 47 | S&F in replacement ofmodular cover plate with frame for 4 module all as specified and directed. |
| 48 | S&F in replacement of modular cover plate with frame for 6 module all as specified and directed. |
| 49 | S&F in replacement of modular cover plate with frame for 8 module all as specified and directed. |
| 50 | S&F in replacement of modular metal flush box 2 module all as specified and directed. |
| 51 | S&F in replacement of modular metal flush box 3 module all as specified and directed. |
| 52 | S&F in replacement of modular metal flush box 4 module all as specified and directed. |
| 53 | S&F in replacement of modular metal flush box 6 module all as specified and directed. |
| 54 | S&F in replacement of modular metal flush box 8 module all as specified and directed. |
| 55 | S&F in replacement of switch piano flush type single pole, one way 6amp complete all as specified and directed. |
| 56 | S&F in replacement of switch piano flush type single pole, one way 15 amp complete all as specified and directed. |
| 57 | S&F in replacement of socket outlet 2 in 1 , 3 pin 5 A flush type complete all as specified and directed. |
| 58 | S&F in replacement ofsocket outlet 2 in 1 , 3 pin 5 A and 15 Aflush type complete all as specified and directed. |
| 59 | S&F in replacement ofceiling rose 65x50mm three terminals 230 volt all as specified complete all as specified and directed. |
| 60 | S&F in replacement oflamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting complete all as specified and directed. |
| 61 | S&F in replacement of bell push flush type 230 Volt complete all as specified and directed. |
| 62 | S&F in replacement of call bell ding dong 230 V single phase complete all as specified and directed. |
| 63 | S&F in replacement of fan regulator electronic type in 5 steps of capacity 120 Watt complete all as specified and directed. |
| 64 | S&F in replacementrecess mounting LED down light of 12 watt of existing make/model complete all as specified and directed. |
| 65 | Supply and fixing in replacementrecess mounting low height backlit roundLED down light of 18 watt of existing make/model complete all as specified and directed. |
| 66 | Supply and fixing in replacementrecess mounting low height backlit squareLED down light of 6 watt of existing make/model complete all as specified and directed. |
| 67 | Supply and fixing in replacementrecess mounting low height backlit squareLED down light of 3 watt of existing make/model complete all as specified and directed. |
| 68 | S&F in replacement of wall mounted, new generationLED Tube light fitting four feet 20 watttincluding all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed |
| 69 | S&F in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 70 | S&F in replacementrecess/Surface mounting LED flat panel 2\"x2\" with high efficient LED & glare free full window opal diffuser of 36 watt incl connecting with twin core twisted flexible copper conductor cable with suitable size rod complete with all accessories all as specified and directed. Note :The LED fitting should Have PF >0.9 ,input voltage 90-300V, IP-65 , LM 80 strandedluminaries efficiency 100 lumen/watt, complete all as specified and as directed. |
| 71 | S&F in replacement Metal clad switch socket outlet with single pole and neutral enclosure with two pin and earth plug socket with 01 No. single pole MCB 20 Amp, 10 KA complete all as specified & directed. |
| 72 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor with inner sheathing of PVC tape and overall PVC sheathed in service connection flat of size 4 sqmm solid aluminium conductor. complete all as specified and directed |
| 73 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor with inner sheathing of PVC tape and overall PVC sheathed in service connection flat of size 6 sqmm solid aluminium conductor.complete all as specified and as directed. |
| 74 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor with inner sheathing of PVC tape and overall PVC sheathed in service connection flat of size 10 sqmm solid aluminium conductor complete all as specified and as directed. |
| 75 | S&F in replacement energy efficient LED Flood light fittingof 70 watt and input voltage 230 VAC, 50 Hz with ingress protection -IP 66with CRCA housingincluding fixing arrengment like clamp nut bolts and washers complete all as specified and as directed.. CRI > 70, PF>0.95, Min 50000 burning Hrs, THD> 20 complete all as specified and directed |
| 76 | S&Fflame proof weather proof LED light fitting20W with all accessories including lamp andnecessary connection wireand testing including taking down old light complete all as specified and as directed. |
| 77 | Taking down/out old unserviceable building security light of any type / wattage and Supply and fixing LED light fittings 35 watts, input 120 volts to 280 volts volts, life > 25000 Hrs, operating temp -20 degree to 50 degree,color temperature 5700K, initial efiicacy>= 100 lm/watt ,IP 66 , high pressure Die cast aluminium housing with weather proof gasket for lamp . the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 5 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light controland comply to IEC60598/IS10322 necessary connection with multistranded copper conductor cable 3 core 1.0 sqmm from ceiling rose to fitting drawn throughGI bracket complete all as specified and directed . |
| 78 | S&F in replacement energy efficient LED Street light fitting (Beamer) of 90 watt and input voltage 230 VAC, 50 Hz with ingress protection -IP 66with CRCA housingincluding fixing arrangement like clamp nut bolts and washers complete all as specified and as directed.. CRI > 70, PF>0.95, Min 50000 burning Hrs, THD> 20 complete all as specified and directed |
| 79 | Taking down / dismantling of unserviceablesubmain wiring of any numbers of wire with wooden battens, PVC conduits/ casing-n-caping any type and of any size with earth wire complete all as specified and as directed. |
| 80 | M&L for submain wiringwith 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distemper all as directed at site complete all as specified and as directed.Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length for payment purpose. |
| 81 | All as per srl item No 80.00 here-in-above but for 2x6 sqmm copper conductor FRLS cable and 1x6 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn in PVC conduit20 mm dia conduit heavy duty complete all as specified and directed by Eng-in-Charge.Note: Two runs of 6Sqmm cable alongwith one run of 6sqmm PVC insulated unsheathed copper conductor as Earth wire conduit and conduit accessories will be measured as one length for payment purpose. |
| 82 | M & Lfor sub main wiring in PVC casing and caping of reqd size 2 x 4.0 Sqmm PVC insulated multistrand copper conductor with 01x 4 Sqmm PVC insulated multistrand copper conductor as earth continuity wire complete all as specified and directed.Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length for payment purpose |
| 83 | M & L for sub main wiring in PVC casing and caping of reqd size 2 x 2.5 Sqmm PVC insulated multistrand copper conductor with 01x 2.5 Sqmm PVC insulated multistrand copper conductor as earth continuity wire complete all as specified and directed.Note : Two runs of 2.5 sqmm cable alongwith one run of 2.5 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length for payment purpose |
| 84 | S&F in replacement sheet metal enclosures 4 way TPN Vertiacal type loadline distribution board of 4 wayincomer + 12 module outgoings ,double door IP 43 protection160 A rated bus bar blanking plates duly flush in wall and making good disturbed surfaces complete all as specified and directed . |
| 85 | S&Fin replacement MCCB three pole415 Volts, 100 A, 16 KA complete all as specified and directed. |
| 86 | S&F in replacementsheet metal enclosures for MCB distribution board 230 Volts TPN 4 way double door typewith 200 Amp rated bus bar concealed in wall including making the surface good complete all as specified and directed. |
| 87 | S&F in replacementsheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door typewith 200 Amp rated bus bar concealed in wall including making the surface good complete all as specified and directed. |
| 88 | S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 12 way double door typewith 200 Amp rated bus bar concealed in wall includingl making the surface good complete all as specified and directed.. |
| 89 | S&F in replacementsheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar conceled in wall including making the surface good complete all as specified and directed. |
| 90 | S&F in replacementMCB three pole and neutral 415 Volts, 63 A, 10 KA C Curve complete all as specified and directed. |
| 91 | S&F in replacementMCB single pole and neutral 240 Volts, 40-63A, 10 KA, C Curvecomplete all as specified and directed. |
| 92 | S&F in replacement MCB single pole 240 Volts, 6 to 32 A, 10 KA, C Curvecomplete all as specified and directed. |
| 93 | M&L in Replacement of earthing complete with galvanized steel earth plate electrode 60x60x0.6cm buried directly in ground to a depth not less than 2.25 Mtr below ground level and top edge of plate not less than 1.5 Mtr below ground level, connected to galvanized earthwire 4 mm by means of GI bolts, nuts, check nut, washer all as shown on Electric Plate No 3 of SSR including earth pit in any soil, char coal, common salt, Black cotton soil in earth pit, 15cm all around earth plate, PCC (1:2:4) type B1 Pit with 40x40x6mm angle iron frame and PCC cover (1:2:4) Type B1, water pipe, funnel GI wire mesh and GI protection pipe light grade 15mm dia7.5 Mtrin length, connecting earth lead to DB/ LT Panel,etccomplete all as specified & directed.Note: if desired earth resistance is not found then entire earthing shall be re-done by Contractor without accruing any extra cost tof the Govt. |
| 94 | Attending complaintfor malfunctioning, not working, not cooling of inverter / non inverter type Split/ Window/ Cassette/ Tower AC of capacity 1.5/2/3 TR, deep fridger/fridge/water cooler /stabilizer upto 5 KVA of any make & model, desert cooler (both pvc and steel body) installed at AFS Ambala area, complete inspection of Cooling appliances rectification of defects, if any all as specified and as directed Note :- (i) Complaint will be resolved within shortest possible time not later than 24 hours of complaint by Engr in Charge/JE concerned otherwise penalty of Rs 500/- per complaint will be recovered from the contracor.(ii) spare parts & servicing will be measured and paid seperately under respective item of the schedule.(iii) Complaints slips will be collected from concerned complaint cell/ JE and will be deposited back after rectification of complaint duly signed by the user. |
| 95 | M & L for Comprehensive maintainance and servicing of split type air conditoner /interver type splitair conditioner of capacity 1.5 / 2.0 Ton, cleaning of cooling/condensing coil,oiling of condenser fan motor, cleaning of air filter , detection of defective parts & replacement with new parts testing smooth functioning complete at siteall as specified and directed. Note :- (i) Defective parts will be measured and paid separately .(ii) Job includes servicing , rectification of defects as one job(iii) Top up gas if required deemed to be included in unit rate Refrigerant gas will be measured as supply only. |
| 96 | M& L for Comprehensive maintainance and servicing of window type air conditoner cap 1.5/2.0 Ton, cleaning of cooling/condensing coil,oiling of condenser fan motor, cleaning of air filter , detection of defective parts & replacement with new parts testing smooth functioning comple all as specified and directed. Note :- (i) Defective parts will be measured and paid separately .(ii) Job includes servicing , rectification of defects as one job.(iii) Top up gas if required deemed to be included in unit rate Refrigerant gas will be measured as supply only. |
| 97 | M& L for Comprehensive maintainance and servicing of Cassette type/ Tower type/split type Air conditonercap 2/3 Ton, cleaning of cooling/condensing coil,oiling of condenser fan motor, cleaning of air filter , detection of defective parts & replacement with new parts testing smooth functioning complete at siteall as specified and directed. Note :- (i) Defective parts will be measured and paid separately .(ii) Job includes servicing , rectification of defects as one job. (iii) Top up gas if required deemed to be included in unit rate Refrigerant gas will be measured as supply only. |
| 98 | M&L for Comprehensive maintainance and servicing of split type AIr conditionercap 3 x 5.5 TR, cleaning of cooling/condensing coil,oiling of condenser fan motor, cleaning of air filter , detection of defective parts & replacement with new parts testing smooth functioning complete at siteall as specified and directed. Note :- (i) Defective parts will be measured and paid separately .(ii) Job includes servicing , rectification of defects as one job. (iii) Top up gas if required deemed to be included in unit rate Refrigerant gas will be measured as supply only. |
| 99 | M & L for detection of refrigerent leakage from split type AC repair of cooling coil / condensing coil for minor leakage if any flushing of system and gas charging in the system up to required and sealing / closing of charging value of slpit type AC / window AC capacity 1.5 TR complete at site all as specified and directed. Note:- Job includes (i) Leak detection with Nitrogen (ii) Evacation is carried out by using a vaccum pump and a recovery bottle , one the system evacuates. |
| 100 | All as per BOQ srl item no. 99.00 here-in-above but for split type AC / window AC capacity 2 TR complete all as specified and as directed. |
| 101 | All as per BOQ srl item no. 99.00 here-in-above but for Cassette type/ Tower type AC cap 2/3 TR complete all as specified and as directed. |
| 102 | All as per BOQ srl item no. 99.00 here-in-above but for split type Air conditioner 3x5.5 TR complete all as specified and as directed. |
| 103 | M & L for rewinding of condensor fan motor ofsplit type AC of capacity 1.5 / 2.0 TR with same gauge of copper insulated winding wire including insulating material complete all as specified and directed. |
| 104 | M & L for taking down unserviceable burnt outcondensor cum blower double shaft fan motor of window AC of capacity 1.5 / 2.0 TR , repairing / rewinding the same with super enamelled copper conductor of existing gauge, replacing the set of bearing including lathe work for making bearing seat complete & installing the same & commissioning complete all as specified and as directed. |
| 105 | M & L for taking down unserviceable burnt Indoor blower fan motor of split AC of capacity 1.5 / 2.0 TR , repairing / rewinding the same with super enamelled copper conductor of existing gauge, replacing the set of bearing including lathe work for making bearing seat complete & installing the same & commissioning complete all as specified and as directed. |
| 106 | Supply, installingof condenser coils of split ACcapacity 1.5 TRin any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed. Note: Charging of refrigerant shall be measured & paid separately |
| 107 | Supply, installingof condenser coils of split ACcapacity 2/3 TRin any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed. Note: Charging of refrigerant shall be measured & paid seprately. |
| 108 | Supply, installing of condenser coils of Window ACcapacity 1.5 /2.0 TRin any location / position including disconnecting electrical mains, removing the clutter, wires, cleaning, removing dust / dirt, etc., around and replacing condenser coil and finally put the rest back together and commissioning including disposing of old unserviceable condenser coil complete all as specified and as directed. Note: Charging of refrigerant shall be measured & paid separately |
| 109 | S & F in repair replacement new sealed Rotary compressor of capacity 19000 BTU/Hour or ( Nearest capacity ) , single phase 230 v , 50 Hz split type conditioner / window type air conditioner complete all as specified and directed.Note - Gas charging will be measured and paid separately . |
| 110 | S & F in repair replacement hermetically sealed Rotary compressor of capacity 25000 BTU/Hour ( for 2 Ton AC) single phase 230 V , 50 Hz split type air conditioner all as specified and directed.Note - Gas charging will be measured and paid separately . |
| 111 | Supply only following spare part for inverter/ non inverter type split AC / window AC complete for any make / Model of capaity 1.5 / 2 / 3 TR complete all as specified and as directed. |
| 112 | Running capacitor 45/36 MFD, complete all as specified and as directed. |
| 113 | Single phase, 220Vconnector for AC of any make and model, complete all as specified and as directed. |
| 114 | Three phase, 415Vconnector for AC of any make and model, complete all as specified and as directed. |
| 115 | PCB of existing make and model ( for split/window ACs non inverter type), complete all as specified and as directed. |
| 116 | PCB of existing make and model ( for invertertype ACs) complete all as specified and as directed. |
| 117 | PCB of existing make and model ( for cassette/pillar type ACs) complete all as specified and as directed. |
| 118 | Cordless remote of existing make and model complete all as specified and as directed. |
| 119 | Condensor motor with Blade complete all as specified and as directed. |
| 120 | Condenser fan blades for window type AC units of capacity 1.5T/2T complete all as specified and as directed. |
| 121 | Condenser fan blades for spilt type AC units of capacity 1.5T/2T complete all as specified and as directed. |
| 122 | Indoor swing motor of capacity 1.5T/2T complete all as specified and as directed. |
| 123 | Wiring kit for window / split type AC units 1.5/2TR complete all as specified and as directed. |
| 124 | Front Grill (front panel) for window type AC units 1.5/2T complete all as specified and as directed. |
| 125 | Indoor Blower wheel complete all as specified and as directed. |
| 126 | Selector switch for Blower motor of window type AC 1.5/2T complete all as specified and as directed. |
| 127 | Suction and discharge valve set for type split AC 1.5/2T complete all as specified and as directed. |
| 128 | Refrigerant Gas R-22 |
| 129 | Refrigerant Gas R-134A |
| 130 | Refrigerant Gas R-32 |
| 131 | Refrigerant Gas R-410 |
| 132 | Supply, installing and testingoutdoor unit comprising of copper Condensor coil , motor with blade ,compressor rotary typeof 1.5 Ton Split type Air conditioner in any location / position including disconnecting electrical mains, removing thewires etc. and commissioning including disposing of old unserviceable outdoor unitdeposited to MES AC section yard complete all as specified and as directed. Note: Charging of refrigerant shall be measured & paid seprately |
| 133 | Supply, installing and testingIndoor unit of 1.5 Ton Split type Air conditioner in any location / position including disconnecting electrical mains, removing thewires etc. and commissioning including disposing of old unserviceable outdoor unitdeposited to MES AC section yard complete all as specified and as directed. Note: Charging of refrigerant shall be measured & paid seprately |
| 134 | Taking down of split type air conditioner from existing location and installation after repair of in same / other location including gas charging , testing , commisioning and comprising of following. complete all as specified and directed. Replacement of refrigerant tubing with insulating sleeve upto 6RM with brass flair nut. Drain pipe upto 6RM Air conditioner bracket-1 set Interconnecting cable from indoor unit to outdoor unit complete all as specified and directed. |
| 135 | Taking down of Window type air conditioner from existing location and installation after repair in same / other location including gas charging , testing , commisioning and comprising of following complete all as specified and directed. Note : Job includes cutting of window at suitable size and making good, if required etc.(ii) The quoted rates are inclusive of driling, clamping and connected items required for fixing and provision ofcable upto required length and other connected items which required for installation and smooth functioning is deemed to be included in quoted rates. |
| 136 | M&L for Comprehensive maintainance and servicing of water cooler cooling cap 40 litre/storage cap 80 litre cleaning of cooling/condensing coil, oiling of condenser fan motor, cleaning of drain pipe testing for smooth functioning complete all as specified and directed. |
| 137 | All as per BOQ srl item no. 136.00 here-in-above but for capacity 120 Ltr (cooling)/150L(storage) complete all as specified and as directed. |
| 138 | Detection of refrigerent leakage from water cooler cooling cap 40 litre, repair of cooling coil/condensing coil for minor leakage if any flushing of system and gas charging in the system up to required qty, and sealing / brazing/soldering complete all as specified and as directed. |
| 139 | All as per BOQ srl item no.138.00 here-in-above but for capacity 150 Ltr complete all as specified and as directed. |
| 140 | S & F in repalcement new sealed compressor for water cooling cap 40litre (or nearest cap) single phase 230 volt, 50 HZwater cooler complete all as specified and directed. Note : Gas charging will be measured & paid separately |
| 141 | M&L for rewinding of condensor fan motor of 1/32 HPwith same gauge of copper insulated winding wire including insulating material complete all as specified and directed |
| 142 | Supply onlyfollowing spare partfor water cooler all as specified and directed |
| 143 | Running capacitor 25/36 MFD |
| 144 | Condensor fan blade |
| 145 | Condensor fan motor |
| 146 | Thermostat |
| 147 | CP self closing push cock 15mm dia |
| 148 | M & L for two coat of spray painting complete outside of water cooler of cap 40/80 or 60/120ltr with hammertone paint over a coat of red oxide primer including scraping the old painted surface , denting and minor patch works complete all as specified and directed. |
| 149 | M&Lfor Comprehensive maintainance and servicingof refrigerator / deep freezer of capacity 165 to 310 litres including labour for detecting the leakage of gas ,repairing leakage and recharging refrigerant, cleaning of cooling coil, condenser, compressors, with vacuum cleaner and cleaning solution, checkingservicibility of electrical / electronic circuits relays, wiring kit, thermostat switches, knobs, etc. andkeeping the units in satisfactory working conditions complete all as specified and as directedNote: Spares / parts / components/ refrigerant gas will be measured and paid separately under relevant items hereinafter and labour charges for replacement shall be deemed to be included in this unit rate quoted |
| 150 | Supply onlyfollowing spare parts for refrigerator / deep freezer of any capacity, make and model complete all as specified and directed |
| 151 | Thermostat switch with knob |
| 152 | Starting relay 1/8HP to 1/6HP open type with OLP |
| 153 | Copper filter, single capillary, pencil type |
| 154 | S&F in repair company made new sealed compressor units for refrigerators including disconnecting electric and water connections in any position / location, cleaning and removing dust / dirt, etc., necessary minor modifying (replacement of capilary tubes, etc.), replacing the compressor and finally putting the rest back together and balance charging of refrigerant gas , including disposing off old unserviceable compressor unitto department store yard complete all as specified and as directed for the following types and capacities: |
| 155 | All as per BOQ srl item No. 154.00 here-in-above but for capacity 165 to 180litres complete all as specified and as directed. |
| 156 | All as per BOQ srl item No. 154.00 here-in-above but for capcity 210/280/300/310litres complete all as specified and as directed. |
| 157 | S&F in repairs evaporator / freezer made out of aluminium pressed type of capacity 165 to 310litres capacity with freezer frame and door including connecting up complete all as specified and as directed |
| 158 | M & L for Comprehensive maintainance and servicingof desert cooler (steel body / Plastic body of any capacity) of fan motor, water pump cleaning of PVC pipe testing including replacement of wood wool pad (set of three) etc for smooth functioning all as specified & directed.Note: Spare parts will be measured and paid separately under respective item of the schedule. |
| 159 | M & L for rewinding of desert cooler motor of same gauge of copper insulated winding including material complete all as specifed and directed |
| 160 | Supply onlyfollowing spare parts for desert cooler (steel body) complete all as specified and directed |
| 161 | Capacitor 4.0mfd to 10 mfd |
| 162 | Fan motor with blade and clamp of 106 watt or nearest capacity single phase complete all as specified and as directed. |
| 163 | Fan motor with blade and clamp of 490 watt or nearest capacity single phase complete all as specified and as directed. |
| 164 | Tullu pump /Water pumpcomplete all as specified and as directed. |
| 165 | Cooling pad of existing size complete all as specified and as directed. |
| 166 | M&L for preparation of surfaces of desert Cooler by scrapping old paint with sand paper,cleaning inner & outer surfaces of body and spray painting the inner surfaces and grills with two coats of black anticorrosive paint and outer surfaces with two coats of alluminium paint, over one coat of zinc chrome primer all as specified and as directed. |
| 167 | M&L in replacement 1100 VoltsPVC insulated copper (flexible) conductor 2.5 Sqmm 3 core complete all as specifed and directed |
| 168 | M & L for repair of voltage stabilizer upto 5 KVA, 230V, 50 Hz, Single phase, including complete inspection of stabilizer, repair/repalcement of defective part including winding if required and refixing the same in original position for smooth functioning all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail