Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | DESCRIPTION OF ITEMS |
| 2 | Taking down cement plaster of any description on brick or stone walls, ceiling etc including rakking out joints , hacking for key , scrubbing down with water at any height etc complete all as specified and as directed. |
| 3 | M&L forrendering in cement mortar (1:4) 15 mm thick on fair faces ofbrick walls or concrete surfaces mixed with water proofing compound as per manufacturer instructions, finished fair andevenwithout using extra cement all complete as specified and as directed. |
| 4 | M & L 10 mm thick rendering in cement mortar 1:6 on brick work or concrete surface, surface finished even and fair complete all as specified and as directed. |
| 5 | M & L rendering 5 mm thick in cement mortar 1:3 on concrete surfaces as in ceiling surface finish even and smooth without using extra cement complete all as specified and directed. |
| 6 | Supply only Liquid water proofing compound complete all as specified and directed. |
| 7 | M & L Preparation newly plastered surfaces andapplying 1mm thickWall care putty onsurfaces of wall as per manufacture\"s instruction complete all as specified and directed. |
| 8 | M&L Two coats of exterior emulsion paint with primer , white or tintedon New surfaces of walls and washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and as directed. |
| 9 | M & L for applying two coats of oil bound distemper over a coat of primer on prepared wall putty surfaces of internal wall all as per specified and directed. |
| 10 | M & L for applying one coats of oil bound distemper over a coat of primer on prepared wall putty surfaces of ceiling all as per specified and directed. |
| 11 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed |
| 12 | M&L Granite stone 18- 20 mm thick(of any type) work (table rubbed and polished) for in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite colour as per direction of GE |
| 13 | M & L 20 - 25 mm thick machine cut Kota stone slab in flooring or treads of steps over and including 20mm thick screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing complete all as specified and as directed. |
| 14 | Description same as per item No 12 above but as in skirting or vertical surfaces including 10 mm thick rendering in cement mortar 1:4, complete all as specified and as directed. |
| 15 | Dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) and rubbish of the premisses complete all as specified and directed. |
| 16 | M&L non skid/mat finish ceramic colour tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm (Colour and design of tiles as approved by Engg in charge), in floors/skirting etc, and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 17 | M&L glazed ceramic coloured tiles size 300mm x 450 mm thick (Colour and design of tiles as approved by Engg-in-charge) on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cementmortar 1:4 complete all as specified and directed. |
| 18 | M & L for vitrified cerameic tiles 9 to10mm thick light shade (square/rectangular )nano polished, area of each tiles not exceeding 0.36 sqm in floor/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed in cement mortar 1:6 complete all as specified and directed. |
| 19 | Demolition of un-reinforced cement concrete in ground floors and pavigns not exc.15 cm thickness. (Below or abve ground level), complete all as specified and as directed. |
| 20 | M&L 75mm thick PCC type C-2 (1:3:6) (using 40 mm graded crushed stone aggregate) as in plinth protection laid in panels, finished even and fair, complete all as specified and as directed. |
| 21 | M&L PCC 1:4:8 type D-2 using (40 mm graded stone aggregate) as in foundation, sub base / mass concrete, Sunken filling etc complete all as specified and as directed. |
| 22 | M & L25 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including finishing surface of concrete topping even and rough complete as in levelling work etc complete all as specified and directed. |
| 23 | Demolition of Brick work built in cement mortar including all quoins arches pillars etc complete all as specified and directed |
| 24 | M&L brick work with sub class B brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 25 | Refixing of shutters after easing and adjusting (in the same opening) of any description of size exc. 1.0 sqm and n. exc. 2.0 sqm complete all as specified and directed. |
| 26 | Taking down chowkhats or Frames with shutter (without taking off shutter from frames) of any description n. exc. 1.50 Sqm each complete all as specified and as directed. |
| 27 | Taking down chowkhats or Frames with shutter (without taking off shutter from frames) of any description exc. 1.50 but n. exc. 4.00 Sqm each complete all as specified and as directed. |
| 28 | Taking down shutter of any description exc. 1.00 but n. exc. 2.00 Sqm each complete all as specified and as directed. |
| 29 | S & F 30 mm thick Flush shutters , solid core construction, with block board core and plywood face panels one face is covered with decorative face veneer with lipping/ frame to match fixed to chowkats complete all as specified and directed. |
| 30 | S & F 2 nd class hard wood35 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass , gauze, etc, (without sash bar) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, section 8, clause 8.24(a) fitted to chowkats complete all as specified and directed. Note :- wire mesh shall be measured and paid separately inrespective supply only item. |
| 31 | supply only Galvnised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm complete as specified and directed. Note- steel wire cloth can be fixed in any type of window, ventilators or doors i.e. aluminium ,steel windows or glazed doors complete all as specified and as directed. |
| 32 | M & L Preparation of New wood or previously untreated surfaces of any description , not otherwise description, over 10 cm width or grith apply two coat of synthetic enemel paint (ordinary tint) over a coat of pink primer complete all as specifed and directed. |
| 33 | M & L for preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over of redoxide zinc chrome coat complete all as specified and as directed. |
| 34 | Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 35 | Providing and fixing factory made uPVC white colour Sliding window (Area n exc. 2.00 sqm) Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated),steel roller system with and including 5mm thick glazing with selected quality glass. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. |
| 36 | Providing and fixing factory made uPVC white color Sliding window Two track made of extruded profiles with wall thickness of 2.3mm (+- 0.2mm). Window profile with hollow section with multi chamber, Frame (60mm x 62mm). sash (42mm x 67mm). Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm) will he mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel frame (30mm x 21.5mm), Sash (30mm x 18mm), profile to be inserted in required profile,frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : [Touch Lock of zinc alloyed (white powder coated), steel roller system with and including 5mm thick glazing with selected quality glass, aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock.] |
| 37 | M & L for Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 38 | S&F for PVC door frames of sizes 50 x 47 mm made out of 5 mm prelam PVC sheet reinforced with MS Square tube in opening of suitable size complete all as specified and directed. |
| 39 | S&F Factory made (Prelam on both sides) solid panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall covered with heat moulded prelam PVC \"C\" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and prelamPVC sheets for top rail, lock rail and bottom rail in either side and as gap insert for top rail and bottom rail pannelling of prelam PVC sheet to be filled in the MS welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together wiht solvent and fixing in the frame at site as per specification and drawing complete all as specified and directed. |
| 40 | S & F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete .complete all as specified and as directed. |
| 41 | S & F aluminium 200 mm long anodised barrel tower bolts ISI marked of extruded section and fixed complete all as specified and as directed. |
| 42 | S & F aluminium 150 mm long anodised barrel tower bolts ISI marked of extruded section and fixed complete all as specified and as directed. |
| 43 | S & F 300 mm mild steel, ordinary rat tail rod pattern spring including roller and roller plate complete fixed to steel frame /wooden frame including necessary welding, cutting, opening of wall for fixing bracket and making good complete all as specified and as directed. |
| 44 | S & F for 125mm Aluminium handles, cast type, anodised fixed with screws complete all as specified and directed. |
| 45 | S & F for 100 mm Aluminium handles, cast type, anodised fixed with screws complete all as specified and directed. |
| 46 | S & F for 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 47 | S & Fpowder coated aluminium door seal 30mm wide and length as per requirement of site including dust/insect arrestor complete all as specified and as directed. |
| 48 | S & F aluminium floor door stoppers double legged length 140mm with hard drawn steel spring fitted in floor complete all as specified and directed. |
| 49 | S & F in repair of100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed. |
| 50 | S & F in repair of aluminium 200 mm long anodised barrel tower bolts ISI marked of extruded section and fixed complete all as specified and as directed. |
| 51 | S & F in repair of aluminium 150 mm long anodised barrel tower bolts ISI marked of extruded section and fixed complete all as specified and as directed. |
| 52 | S & F in repair of 125mm Aluminium handles, cast type, anodised fixed with screws complete all as specified and directed. |
| 53 | Taking up or down existing steel tubing and connection complete for following sizes:-(a)15 mm dia bore |
| 54 | (b)20 mm dia bore |
| 55 | (c)25 mm dia bore |
| 56 | Supplying, fixing, jointing and testing galvanised steel water tubing medium grade with all fittings such as bend, elbow, socket reducer etc fixed to walls and ceilings or laid in floors, complete for the following sizes: -(a)15mm dia bore |
| 57 | (b)20 mm dia bore |
| 58 | (c)25 mm dia bore |
| 59 | S&F500 Ltrs capacity rotational moulded polyethylene water storage tanks, (cylindrical vertical with closed top) hoisted and fixed in position including taking down, all as specified in SSR part-I complete all as specified and as directed. |
| 60 | S&F in repair ball valve/float ballhigh pressure of PTMT 20mmwith epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed minimume weight 210 gm etc all as specified and directed. |
| 61 | S&F in repair of gun metal gate valves 15 mm with lever arm screwd both ends for iron pipes complete all as specified and directed. |
| 62 | S & F in repairs 15 mm bore bib taps chromium plated fancy type cast copper alloy crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, and fixed complete all as specified and directed. |
| 63 | S & F in repairs chromium plated fancy type stop cock/angle cock 15 mm dia cast copper alloy screwed down, high pressure, with crutch or butter fly handle screwed both ends for iron pipeor for unions and fixed, complete all as specified & directed. |
| 64 | S & F in repairs 15 mm bore two way angle valve, chromium plated cast copper alloy long body , screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 65 | S & F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 66 | Supply and fixin repair ofwash hand basins with pedestal, vitreous china,of size 550x400mm (flat back, or angle back type)including cutting for and pinning in ends of brackets or erecting stand exclusive of fixing of supply and waste pipe etc complete all as specified and directed. |
| 67 | S & F in repairs Vitreous china wash down water closet pan (pedestal pattern), white including pedestrial pan and trap, including seat cover for pedestial pan, jet spray and connecting to drain or outgoing pipe and to flushing pipe, antisyphonage pipe etc complete all as specified and directed. |
| 68 | S&F in repair stainless steel kitchen plate rack made out of 1mm thick stainless steel of size 900 x 600 mm ofbest quality of approved make, complete all as specified and as directed. |
| 69 | S&F in repairs of Bevelled edge mirror of 5 to 6 mm thick selected quality glass of size 600 x 450 mm mounted on 6mm thickAC building board or commercial plywood andfixed to wooden plug with Chromium Plated brass screw and cup washers complete complete all as specified & directed. |
| 70 | S& F in repairs of sheet glass shelf assembly, approved make, consisting of 5.5mm thick sheet glass shelf60mm wide with chromium plated bracket guard and railing 500mm long completeall as specified & directed. |
| 71 | S&F in repairs corner glass shelf 5.5mm thick with aluminium bracket and railing as per sample, complete all as specified and as directed. |
| 72 | S&Fin repair ofPVC valveless, syphonic action type flushing cistern,low/high level white with inlet ball valve float and handle including brackets complete fixrd in repair capacity of flush 10 ltrs complete all as specified and directed. |
| 73 | S & F in repair Sink Mixer 15 mm CP Fancy exclusive type as per direction by Engg-in-charge, complete all as specified and directed. |
| 74 | S & F in repairs of Wall mixer CP hot & cold, 15mm bore, bright finish with three joints screwed the ends for iron pipeand plugging complete all as specified and directed. |
| 75 | S&F in repair 15 mm bore basin mixer Fancy Type brass chromium plated with capstan headsscrewed down high pressure with or withoutletter ‘HOT’ or‘COLD’ with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and directed. |
| 76 | S&F in repair of Drapory/curtain rod 20-25 mm dia of stainless steel fixed with fancy type matching pair of bracket not less than 75 grams each fixed with screw complete all as specified and as directed. |
| 77 | S & F in repair of 15mm bore, 450mm long, PVC connections with brass unions internally threaded both ends complete fixed to iron pipe at both ends complete all as specified and directed. |
| 78 | S & F in repairs of CP Brass Fancy type shower rose 125 mm dia with 125mm long CP Nipple of approved quality complete all as specified and directed. |
| 79 | S&F in repairs brass CP toilet paper holder fancy type as kept in sample room, complete all as specified and directed. |
| 80 | S & F in repairs stainless steel wall mount case with soap holder & brush holder fixed to wall as kept in sample room, complete all as specified and as directed. |
| 81 | S&F in repair of110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall / floor with clip complete all as specified and directed. |
| 82 | S&F in repair of 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall / floor with clip complete all as specified and directed. |
| 83 | S & F in repair 110 mm dia bore PVC (SWR) bends with acess door any radius with solvent rubber ring joints, fixed complete all as specified and directed. |
| 84 | S&F in repair of PVC ( SWR) bends any radius bore of 110 mm all as specified and directed. |
| 85 | S&F in repair of PVC ( SWR) bends any radius bore of 75 mm all as specified and directed. |
| 86 | S&F in repair ofPVC (SWR) junction single, (Single T) equal or unequal of bore 110 mm all as specified and directed. |
| 87 | S&F in repair of PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed. |
| 88 | S&F in repair of 18/19mm Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed. |
| 89 | S & F in repair Factory made PVC cabinet of required size fabricated by joining for 18mm plain white for boxes /coloured for shutters (600 kg density) thick PVC Celuka ply fixed with each other using solvent cement adhesive and screws and 18mm thick PVC sheet as backing of cabinet fixed with screw and solvent cement adhesive including batten and soft closing hinges for fixing of shutter, complete all as specified and directed. |
| 90 | S & F Continuous (piano) hinges having width of flaps 40mm(when open),mild steel, bright finish or electrogalvanised complete all as specified and directed. |
| 91 | Complete removal of existing treatment on wall(Internal/External) /roof projections including facias, cornics etc(Internal & External surfaces by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc) by skilled labour complete all as specified and directed. |
| 92 | M & L Two coats of exterior emulsion paint with primer , white or tintedon prepared surfaces of walls and washing floors, cleaning glass, joinery, electrical fittings, wiring etc. , of drops and splashes complete all as specified. |
| 93 | M & L for applying two coats of oil bound distemper over a coat of primer on prepared wall putty surfaces of internal wall all as per specified and directed. |
| 94 | M & L for applying one coats of oil bound distemper over a coat of primer on prepared wall putty surfaces of ceiling all as per specified and directed. |
| 95 | S & F in repair of flush pipe of polyethylene of low or high density or PVC, 32mm dia for low level flushing cistern/basins complete as complete all as specified and directed. |
| 96 | M & L in repair to sunken floor by providing water proofing treatment to sunken floor surfaces of RCC slabincluding demolation of old sunken by the following specifications as specified and directed :- (a) Provide PCC 1 : 1.5 : 3 type A with using 12.5mm graded stone aggregate in slope of average thickness 50mm on sunken floor slab mixed with and including integral water proofing compoundmanufactured by Dr FIXIT or equivalent as approved, finish the surface even & smooth without using extra cement.(b) Rendering 15mm thick in CM 1:3 mixed with & including integral water proofing compound on sunken floor and sides of (Vertical surface) sunken portion.(c) Applying surfaces of bituminous primer (conforming to IS-3384-1965) @ 0.40 Kg/Sqm complete. oncomplete sunken surfaces of floor & wall and provide necessary connections to soil/waste pipe from WC/ nahani trap etc(d) Applying a tack coat of Industrial bitumen grade of 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces (1st coat for bonding material below membrane and 2nd coat on top of membrane. Each coat would be paid seperately.) (e) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm)land on primed surface by forced application complete all as specified and directed. Note : Floor Area shall be measured for payment. |
| 97 | Supply & Fixed in repairs 15mm bore steel water tubing \"medium grade\"galvanised ,with all fitting and fixed completeto walls and ceiling or laid in floor etc complete all as specified and as directed. |
| 98 | Supply & Fixed in repairs 20 mm bore steel water tubing \"medium grade\"galvanised ,with all fitting and fixed completeto walls and ceiling or laid in flooretc complete all as specified and as directed. |
| 99 | M & L 10 mm thick rendering in CM (1:3) mixed with integral water proofing chemical compound over concrete surface, parapetand finishing the surface fair and even without using extra cement complete all as specified |
| 100 | M&L Water proofing treatment on \"Non approachable / non accessible roof\" surface (Horizontal & Vertical surfaces) in following sequence through authorized applicator of the manufacturer all as specified and directed complete.(i) Surface prepration like opening the cracks/removal of loose concerete.(ii) Pressure washing the entire roof to remove dirt , dust alage fungi or other contaminants from joints and entire surface.(iii)Saturation of surface nano technology based deep penetrating sealer application to block pores , capillaries and micro cracks.(iv) Filling the crack with flexible polymer based caulk and further sealing with reinforcement fabric elastomeric coating.(v) Sealing joints and coving area with flexi reinforcement fabric and elastomeric coating.(vi) Priming coat of dr fixit URP with flexi reinforcement fabric. (vii) First and Second coat of elastomeric dr fixit Roof Seal . The authorized applicators are under :-(i) Pidilite industries.(II) Berger paints. (iii) asian paints and equivalent. Note : A warranty of 10 years be provided by the contractor for the service rendered. |
| 101 | Disconnectling existing water tank Exc 250 & N.exc 500 litres capacity setting aside or lowering if requied for roof repair, cleaning etc. and hoisting in position reconnecting, refixing in position up to 2 storey bldgsall as specified and directed. |
| 102 | Removal of existing treatment and wire brushing and cleaning top surface of tiles and roofs to preparation of surface for applying in primer and bitumen and removal of debris and rubbish off the site. |
| 103 | M & L for 25mm thick PCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) as in roof for maintaining the uniform slope etc any thickness at any height and in any position complete all as specified and directed. |
| 104 | M & L for 15mm thick rendering on fair faces of concrete surfaces in CM 1:4 with water proofing compound @ 200ml per 50 Kg of cement finished even and fair complete all as specified and directed. Note : WPC shall be measured and paid separately. |
| 105 | supply and Applying APP based polymeric membrane minimum weight 3Kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150gms/sqm) land on coat of bituminous shalitex primer @ 0.3litres/sqm by forced application complete all as specified and directed.NOTE:- Laying shall be done all as per manufacturer\"s instruction and all as specified in clauses 11.43 of MES SSR-2020 Specifications. |
| 106 | M & L for non skid ceramic (coloured) 10 mm thick heat resistance Roof tiles (SRI > 90) (square/rectangular) area of each tile exceeding 0.06 sqm but not exc 0.18 sqm as in roof, chhajjas etc,laid over and including screed bed in CM(1:6), set, jointed and pointed in neat cement slurry complete all as specified. |
| 107 | M & L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, at the junction of roofing to vertical surfaces complete all as specified and as directed. |
| 108 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm girth but n exc. 20 cm complete all as specified. |
| 109 | Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 110 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 111 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 112 | M & L for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed. |
| 113 | M & L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers not exc.15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 114 | M & L for 75mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 115 | M & L for brickwork with old sized sub-class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM(1:4) complete all as specified and directed. |
| 116 | M & L for 10mm thick cement plaster in CM (1:6) on other than fair surfaces of brick walls and finishing the surfaces fair and even complete all as specified and directed. |
| 117 | M & L for preparation of new wall surfaces and applying two coats of distemper oil emulsion over a layer of 1mm thick wall care putty complete all as specified and directed. |
| 118 | M & L for preparing new surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 119 | M & L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 120 | M & L for formwork to Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 121 | M & L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 122 | M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, work in rough finished surfaces of concrete complete all as specified and as directed. |
| 123 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 124 | M & L for 40mm thick damp proof course in cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary formwork and using water proofing compound as per manufacturer\"s instructions complete all as specified and directed Note : WPC shall be measured and paid separately. |
| 125 | S & F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Gde Fe-410 W (Gde- E- 250) quality-A complete all as specified and as directed. |
| 126 | S & F of rolled mild steel works as in bands, straps, supports or stays for rainwater, hook and pintle hinges, clamps, hold fasts, wall ties, hooks for hanging fans, gusset plates, plain angle cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 127 | S & F of Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 128 | S & F of pre-painted galvalume aluminium zinc coating GI base corrugated steel sheet 0.50 mm thick trapezoidal pattern of any colour having tensile strength of 550 MPa as in roof covering, fixed with self tapping screws complete all as specified and directed. |
| 129 | S & F of Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 130 | S & F of vitreous china wash hand basin white flat back of size 550mm x 400mm including cutting for and pinning ends of brackets including 32mm bore PTMT waste coupling (half or full threaded) and PVC waste pipe 32mm dia and 15mm bore PVC connection 450mm long with brass union and jam nuts on both sides and fixed on a pair of MS cantilever bracket of appropriate size complete all as specified and directed. |
| 131 | S & F of 15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 132 | S & F of 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engineer-in- Charge. |
| 133 | S & F of towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and directed. |
| 134 | S & F of vitreous china squatting pan of Orissa pattern, size 580x440 mm size white with integral foot rest with Cast Iron `P\" or `S\" trap, front or back inlet andincluding connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including cement concrete bedding including providing new flush pipe complete all as specified and directed. |
| 135 | S & F of vitreous china wash down water closet pan (EWC pedastal pattern) white,with Cast Iron `P\" or `S\" trap, front or back inlet andincluding connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including cement concrete bedding and including mild steel chromium plated or aluminised hinging device seat cover (white) complete all as specified and directed. |
| 136 | S & F of health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 137 | S & F of PVC low level flushing cistern 10 Litres capacity with all internal accessories and fixed to wall including 450mm long PVC connection pipe 15mm bore with brass union and jam nuts on both sides, PVC flush pipe 32mm dia fixed properly to inlet of WC complete all as specified and directed. |
| 138 | S & F of 15mm bore bib taps fancy type, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified or as directed. |
| 139 | S & F of 15mm bore angular stop cock fancy type, cast copper alloy chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed. |
| 140 | S & F of 15mm bore concealed stop cock fancy type, cast copper alloy chromium plated long shank and cup, screwed down, screwed for iron pipe of 15mm bore all as specified or as directed. |
| 141 | S & F of brass chromium plated shower rose of 125mm size with or without swivel joints including fixing to steel pipe or union all as specified and directed. |
| 142 | Supplying, hoisting and fixing of rotational moulded PVC water storage tank, 1000 litres capacity conforming to IS-12701 (1996) cylindrical vertical type triple-layered with closed top including 20mm bore PVC float valve and necessary fittings for inlet, outlet and wash out holes complete all as specified and as directed. |
| 143 | S & F of powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified complete all as specified and directed by Engineer-in-Charge. |
| 144 | S & F of Stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 145 | S & F of sheet glass (frosted on one side) of 4.80mm thick ordinary quality glass and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and directed. |
| 146 | S & F of suspended ceiling system of grid/section of size 600x600mm comprising of interlocking GI powder coated main T-runners of size 24x38x0.33mm thick of length 3000mm,cross-T of size 24X32X0.33mm thick of length 1200mm and secondary intermediate cross-T of size 24X32X0.33mm thick of length 600mm and perimeter wall angle of size 24x24x0.40mm thick of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs @ 450mm center to center and 40mm long dry wall S.S. screws with and including 4 mm thick E-board false ceiling tiles of size 595x595mm of approved texture, design and pattern to be placed in the grid system duly suspended with 6 mm dia GI wire hangers fixed with steel dash fasteners or from purlin of the roof with clip complete all as specified and directed. |
| 147 | S & F of 75mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified. |
| 148 | S & F PVC (SWR) vents cowl 110m dia complete all as specified and directed. |
| 149 | S & F of aluminium butt hinges medium weight 100mm type C-21 complete all as specified. |
| 150 | E&M |
| 151 | Taking down copper /aluminium point wiring (light, fan, bell,socketor power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc.Removing materials to store for keeping in safe custody or for taking credits and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed at site. |
| 152 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 153 | Taking down carefully copper/aluminium Sub main wiring of any size fromsurface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 154 | Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to MES store yard complete all as specified and as directed. |
| 155 | Taking down existing single phase electronic energy meter of any capacity after disconnecting all necessary electrical connections and deposit to MES store yard complete all as specified and as directed. |
| 156 | M&L for point wiring with 1.5 Sq mmsingle corePVC insulated unsheathedcopper FRLSH multi stranded conductor cable in andincludingConcealed PVC conduitof size 20/25mm ISImarked inclusive oftees ,bend ,elbows etc upto and including sunk in modular metal flush box of required module for housing modular switch socket etc with modular cover plate with frame of required modulecomplete including PVC insulated multi strandedcopper conductor 1.5Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincludingcutting, chasses and makinggooddisturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- |
| 157 | (a) One light point controlled by one, one way modular switch 6 Amps |
| 158 | (b) One light point controlled by one, two way modular switch 5 Amps |
| 159 | (c) One fan point/ exhaust fan point controlled by one, one way modular switch 6 Amps and regulator |
| 160 | (d)One 2/3 pin 6 Amps modular switch socket outlet point controlled by one modular switch on the same board. |
| 161 | (e) One 2/3 pin 6 Amps modular switch socket outlet point controlled by one modular switch on independent boad. |
| 162 | (f)One bell point controlled by one, modular bell switch 6 Amps |
| 163 | Description all as per item No 155 here in before butusing 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 164 | S & F for modular switch,1 way 6 amp,1 module 230 Volts complete all as specified and directed at site. |
| 165 | S & F for modular switch,2 way 6 amp,1 module 230 Volts complete all as specified and directed at site. |
| 166 | S & F for modular switch,1 way 16 amp,1 module 230 Volts complete all as specified and directed at site. |
| 167 | S & F for modular bell push, 6 amp, 1 module 230 Volts Complete all as specified and directed at site. |
| 168 | S & F formodular socket outlet 2/3 pin combined, 6 amp, 2 module 230 Volts complete all as specified and directed at site. |
| 169 | S & F formodular socket outlet 2/3 pin combined, 6A/16A amp, 2 module 230 Volts complete all as specified and directed at site. |
| 170 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISImarked for batten fitting complete all as specified |
| 171 | S & F for modular fan step regulator 120W, 2 module complete all as specified and directed at site. |
| 172 | S & Ffor lamp holder , PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed. |
| 173 | S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 174 | M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed.Note:- Two runs of 6 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit |
| 175 | S&F MCB DB sheet metal enclosure for DB, TPN, 4 way having protectionwith 200 amps rated bus bar, 240 volts, double door type, suitable for housing MCB\"s and isolators, concealed in wall, complete all as specified and directed. |
| 176 | S & F for sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 177 | S&F isolator TPN, 433 volts, B Curve, 100 Amps of 10 KA, complete all as specified and directed. |
| 178 | S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 179 | S & Ffor MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |
| 180 | S&F D Box with MCB protected Socket with plug 20 A with sheet steel Enclosure suitable for AC/Geyser & industrial use (without wire) as specification IS 13032 & IS 8623 20A MCB complete all as specified and as directed. |
| 181 | Fixing only for refixing the celing fan with copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal complete all as specified and as directed. |
| 182 | S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap complete all as specified and directed |
| 183 | S&F LED integrated batten box type surface mouted, 1x20 Watt prewired including electric electrical connection with PVC insulated twin twistedcopper wire of suitable size from ceiling rose to tube light fitting all as specified and directed. |
| 184 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 185 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 186 | Supply and fixing LED Bldg sec light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 187 | Refixing existing single phase electronic energy meter of any capacity after connecting all necessary electrical connections complete all as specified and as directed. |
| 188 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed. |
| 189 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm all as specified and directed. |
| 190 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece, hot & cold PVC connections etc complete all as specified and as directed. |
| 191 | M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6.0 mm thick, burrieddirectly in ground (earth pit not less than 2.25 metres deep belowground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0mm dia Protedcted by light GI Pipe 20 mm dia and 15 dia med grade for watering pipe and connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, iron funnel,Iron pit cover and chamberall as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed. |
| 192 | Supply and laying, XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 25 sqmm 4 core including taking out old unserviceable cable from pole/trenches/wall/under road etc complete all as specified and directed by Engr-in-Charge. |
| 193 | Supply and laying, XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 10 sqmm 2 core including taking out old unserviceable cable from pole/trenches/wall/under road etc complete all as specified and directed by Engr-in-Charge. |
| 194 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m in depth oftrenches for laying of pipe lines and getting out including forming bottom surfaces to required level complete all as specified and as directed. |
| 195 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm all as specified and directed. |
| 196 | Removing excavated material (soil) at a distance n.exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed. |
| 197 | M&L for providing dry sand as in cushioning to underground cable including punning down of sand in layers as specified and directed. |
| 198 | M&L for brick protection cover of UG cable by using old size sub class \"B\"\"common burnt clay building bricks,laid dry and flat abutting each other with width equal to length of the brick and gap between adjacent brick n.exc 10 mm complete all as specified and directed. |
| 199 | S&F GI Pipe 40 mm dia light gradefor protection of cable complete all as specified and as directed. |
| 200 | Note : Tenderers may note that amount of credit Rs 55,334.72 will be deducted from the total amount arrived, at the time of Acceptance of contract. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy