| 1 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals. |
| 2 | Of area 3 sq. metres and below |
| 3 | Providing and fixing (35 mm thick Second class teak wood) glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, (weight not less than 10 kg per sqm) /Wire Mesh fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals |
| 4 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals |
| 5 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 6 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately) including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals |
| 7 | 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT- I or graded wood particle board FPT- I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and prelaminated conforming to IS : 12823, Grade 1, Type - II marked : |
| 8 | Providing and fixing (35 mm thick Second class teak wood )shutters wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screwsincluding entire carriage of materials with in all leads, lifts, height and cost of all other incidentals : With ISI marked stainless steel butt hinges of required size |
| 9 | Providing and fixing (50x12 mm 2nd class teak wood )woodenmoulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. completeincluding entire carriage of materials with in all leads, lifts, height and cost of all other incidentals. |
| 10 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals |
| 11 | Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) |
| 12 | Finishing with Deluxe Multi surface paintof (Asian/ Nerolac/ Berger) system for interiors and exteriors using Primer as per manufacturers specificationsincluding entire carriage of materials with in all leads, lifts, height and cost of all other incidentals |
| 13 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 14 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubularsections/appropriate Z sections and other sections of (Jindal, Hindalco , Nalco ) approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately)including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals. For Fixed Portion |
| 15 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 16 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 17 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 18 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 19 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 20 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals. |
| 21 | With float plain/frosted glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 22 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 23 | With stainless steel cover plate minimum 1.25 mm thickness |
| 24 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern,(Jindal, Hindalco , Nalco ) with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals (Only weight of grill to be measured for payment). |
| 25 | Providing and Fixing 2mm thick Bakelite Sheet/Acrylic Sheet where as required as per site in Doors/Fixed Portion/Cupboards Shutters etc compete as per Direction of Engineer-in charge including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals (Cost of Beading and gasket rubber shall be paid seprately in Basic item) |
| 26 | Providing and fixing 250 X 16 mmsize aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screwsetc. completeincluding entire carriage of materials with in all leads, lifts, height and cost of all other incidentals. |
| 27 | Providing and fixing 125 mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. completeincluding entire carriage of materials with in all leads, lifts, height and cost of all other incidentals. |
| 28 | Providing and fixing 150 mm X 10 mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals. |
| 29 | Providing and fixing double scaffolding system (cup lock type) onthe exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joiningwith cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldingfor workingplatform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .Thescaffolding system shall be stiffened with bracings, runners,connection with the building etc wherever required for inspection ofwork at required locations with essential safety features for theworkmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measuredfor payment purpose .The payment will be made once irrespective of duration of scaffolding including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals |
| 30 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals |
| 31 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 32 | Welding by gas or electric plant including transportation of plant at siteetc. Complete including entire carriage of materials with in all leads, lifts, height and cost of all other incidentals. |