| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 2 | Group C |
| 3 | Supplying and fixing following size/modules GI box along with modular base and cover plate for modular switches in recess etc as reqd. |
| 4 | 6 Module (200mmX75mm) |
| 5 | 12 Module (200mmX150mm) |
| 6 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 7 | 5/6 amps switch |
| 8 | 3 pin 5/6 amps socket outlet |
| 9 | 15 /16 amps switch |
| 10 | 6 pin 15/16 amp socket outlet |
| 11 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. |
| 12 | 3 x 2.5 sq.mm |
| 13 | 3 x 4 sq.mm |
| 14 | 3 x 6 sq.mm |
| 15 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 16 | Supplying regulator and on fixing the two module stepped type electronic fan existing modular plate switch box connections but excluding modular plate etc. as required. |
| 17 | Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design,18 Watt, 2100lm, 50000 burning hours, size 1200mm in existing single box or double box fittings complete as required. tube equivalent to Philips Make, Cat No.MAS LED tube 1200mm 18 W 856 TBI-2100lm |
| 18 | Supply, Installation, testing and commissioning of pre-wired, Double box fitting with Two no. LED tube of frosted cover design,18 Watt, 2100lm, 50000 burning hours, size 1200mmcomplete i/c accessories etc. directly on ceiling/wall, including connection with 1.5 sqmm FRLS PVC insulated, copper conductor cable and earthling etc.as required. Fitting equivalent to Philips Make, Cat No.TMC 502 2XT-LED 22W, tube equivalent to Philips Make, Cat No.MAS LED tube 1200mm 18 W 856 TBI-2100lm |
| 19 | S/F snap-in DLP trunking of 105 mm X 50 mm with suitable cover on the existing wall/ surface i/c having all the accessories such asflat angle, end caps, internal/ external angle etc. as required at site. |
| 20 | Supplying and fixing of 63Amp, Four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Equivlant to make legrand Cat. Nos 4118 83. |
| 21 | Supply, Installation,testing and comissioning of 12 inch heavy duty, AC, Single Phase 230 Volt, 50 Hz, 1350 RPM, steel body exhaust fan in the existing opening, including, making good the damage, cable connection etc. as required |