| Sl. No. | Item Description |
| 1 | (SH: Construction of Bunglow)Annexure-I |
| 2 | Earthwork in excavationbymechanical means ( Hydraulic Excavator)/ manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. All kinds of soil. |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer cum by ramming and watering lead upto 50 m and lift upto 1.5 m |
| 4 | Supplying and filling in plinth with sandy soil under floors including, watering ,ramming consolidating and dressing complete. |
| 5 | CEMENT CONCRETE WORKS |
| 6 | Providing and laying in position specified grade of reinforced cement concrete workexcluding cost of centering, shuttering and reinforcement- All work up to plinth level: 1:1.5:3 (1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) |
| 7 | FORM WORK |
| 8 | Centering & shuttering including strutting & propping etc.& removal of form for: (a) Foundation, footings, bases of columns etc. for mass concrete. |
| 9 | b) Columns ,Pillars,Piers,Abutments, Posts and Struts. |
| 10 | c) Lintels ,beams,plinth beams ,girders, bressumers and cantilevers |
| 11 | d) Suspended floors, roofs, landings, balconies and access platform |
| 12 | e) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 13 | f) Stairs, (excluding landings) except spiral-staircases. |
| 14 | g) Arches, domes, vaults upto 6m span |
| 15 | R.C.C Work |
| 16 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength ; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. |
| 17 | i) All works upto Plinth level.a) Concrete of M-25 grade with minimum cement content of 330Kg/cum |
| 18 | ii) All works above Plinth level upto floor V Levela) Concrete of M-25 grade with minimum cement content of 330Kg/cum |
| 19 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars |
| 20 | BRICK WORK |
| 21 | Brick work with 1st class common burnt clay F.P.S (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 22 | Half brick masonary with 1st class common burnt clay F.P.S (non modular) bricks in superstructure above plinth level upto V level in a) Cement mortar 1:4 (1 cement : 4 c/sand) |
| 23 | WOOD WORK |
| 24 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately :Local best quality Uningthou wood(a) Local best quality Uningthou |
| 25 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for seperately, all complete as per direction of Engineer-in-charge. Float Glass panes 4mm thick. |
| 26 | Providing and fixing bright finished brass butt hinges withnecessary screws etc. complete :125x85x5.5 mm (heavy type) |
| 27 | Providing and fixing ISI marked oxidised M.S. Tower bolts black finished(barrel type ) with screws etc. complete. 250 X 10mm. |
| 28 | Providing and fixing bright finished steel 100 mm door mortice latch with one dead bolt and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 29 | Providing and fixing ISI marked oxidised MS handles conforming to IS:4992 with necessary screws etc. complete : a)125mm |
| 30 | STEEL WORKS |
| 31 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. - Fixed to openings /wooden frames with rawl plugs screws etc. |
| 32 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 33 | FLOORING |
| 34 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : 1:2:4 (1 Cement : 2 Coarse sand : 4 Graded stone aggregate 20mm nominal size) |
| 35 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 36 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement [email protected] kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of sizeSize of Tile 600 x 1200 mm |
| 37 | Marble stone flooring with18mm thick marble stone (sample ofmarble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : Makrana white second quality |
| 38 | Extra for prefinished nosing to treads of steps of marble stone. |
| 39 | ROOFING |
| 40 | Providing and laying pressed clay tiles (as per approved pattern 20mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1Cement : 4 Coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse Sand) and finish neat complete. |
| 41 | FINISHING |
| 42 | 12 mm cement plaster 1 : 4 (1 cement : 4 coarse sand) |
| 43 | 15 mm cement plaster on rough side of single or half brick wall of mix 1 : 4 (1 cement : 4 coarse sand) |
| 44 | Providing and applying white cement based putty of average thickness 1mm of approved brand manufacture, over the plastered wall surface to prepare the surface even and smooth complete. |
| 45 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer |
| 46 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 47 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade. i) Two or more coats on new work- |
| 48 | Applying priming coat with ready mixedpink or grey primer of approved brand and manufacture on wood work.(Hard and soft wood). |
| 49 | Providing and applying two coats of fire retardant paint unthinned on cleaned wood/ ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. |
| 50 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 51 | SANITARY INSTALLATIONS |
| 52 | Providingand fixing water closet squatting pan (Indian type W.C. pan ) with 100 mmsand cast Iron P or S trap, 10 litre low levelwhiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580 x 440 mm with integral type foot rests |
| 53 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 54 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CPBrass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass |
| 55 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 250 mm |
| 56 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 57 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 58 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia |
| 59 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete semi rigid pipe 40 mm |
| 60 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm |
| 61 | WATER SUPPLY |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 63 | a) 32 mm dia pipe |
| 64 | b) 50 mm dia pipe |
| 65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the wall etca) 25 mm dia pipe |
| 66 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 67 | (SH: Construction of Garrage) Annexure-II |
| 68 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. All kinds of soil. |
| 69 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth m level : 1:4:8 (1 Cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size |
| 70 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars |
| 71 | Centering and shuttering including strutting, propping etc. and removal of form for(a)Foundation, footings, bases of columns etc. and mass concrete. |
| 72 | (b) Columns, pillars, Piers, Abutments, Posts and Struts |
| 73 | (C) Lintels, beams, plinth beam, girders, bressumers and cantilevers. |
| 74 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement (all work upto plinth level) b) 1: 1.5: 3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm. nominal size). |
| 75 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttress, plinth and string Coarses, fillets, columns, pillars, piers, abutments posts and struts etc. above plinth level upto floor five level excluding cost of centering, shuttering, finishing and reinforcement b)1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggrt, 20mm nominal size). |
| 76 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 77 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre |
| 78 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 79 | Half brick masonary with 1st class common burnt clay F.P.S (non modular) bricks in superstructure above plinth level upto V level in a) Cement mortar 1:4 (1 cement : 4 c/sand) |
| 80 | 12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 Coarse sand) |
| 81 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement : 4 Coarse sand) |
| 82 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 83 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement prime |
| 84 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade. Two or more coats on new work |
| 85 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 86 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. |
| 87 | Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum |
| 88 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500-600mm) Precoated Galvanise |
| 89 | (SH: Construction of Security Barrack )Annexure-III |
| 90 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. All kinds of soil. |
| 91 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth m level : 1:4:8 (1 Cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size |
| 92 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars |
| 93 | Centering and shuttering including strutting, propping etc. and removal of form for(a)Foundation, footings, bases of columns etc. and mass concrete. |
| 94 | (b) Columns, pillars, Piers, Abutments, Posts and Struts |
| 95 | (C) Lintels, beams, plinth beam, girders, bressumers and cantilevers. |
| 96 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement (all work upto plinth level) b) 1: 1.5: 3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm. nominal size). |
| 97 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttress, plinth and string Coarses, fillets, columns, pillars, piers, abutments posts and struts etc. above plinth level upto floor five level excluding cost of centering, shuttering, finishing and reinforcement b)1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggrt, 20mm nominal size). |
| 98 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 99 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre |
| 100 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x1200 mm |
| 101 | Brick work with 1st class common burnt clay F.P.S (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 102 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 103 | Half brick masonary with 1st class common burnt clay F.P.S (non modular) bricks in superstructure above plinth level upto V level in a) Cement mortar 1:4 (1 cement : 4 c/sand) |
| 104 | 12 mm cement plaster finishedwith a floating coat of neat cement of mix1:4 (1 cement: 4 coarsesand). |
| 105 | 15 mm cement plaster 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall. |
| 106 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 107 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement prime |
| 108 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade. Two or more coats on new work |
| 109 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 110 | Providing wood works in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for seperately: Local best quality Tolhao wood. |
| 111 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Local Best Quality Tolhao Wood. 35mm thick shutters |
| 112 | Applying priming coat With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 113 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture. |
| 114 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :i) 200 x 10 mm |
| 115 | ii) 150x 10 mm |
| 116 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete (ii) 250 x 16 mm |
| 117 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :(i) 125 mm |
| 118 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm center to center, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts and bolts of required fixed with intermediate GI channels 45x15x0.9 mm running at the spacing of 1200 mm centre, to which the ceiling section o.5 mm thick bottom wedge of 80 mm with tapered flanges of 26mm each having lips of 10.5 mm, at 450 mm centre, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clips made outof 2.64 mm ida x 230 mm long G.I wire at every junction, including fixing perimeter channels 05. mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of celing fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long dry wall |
| 119 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. |
| 120 | Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum. Precoated Galvanised Iron Profile Sheet 0.50mm thick |
| 121 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500-600mm) Precoated Galvanise. Precoated Galvanised Iron Profile Sheet 0.50mm thick |
| 122 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : a) W.C. pan with ISI marked white solid plastic seat and lid. |
| 123 | roviding and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass |
| 124 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :16.9.1. Kitchen sink with drain board |
| 125 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.( semi regid):32 mm dia |
| 126 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. (Internal works - exposed on wall):32 mm nominal outer dia pipes |
| 127 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work- exposed on wall 20 mm nominal outer dia pipes |
| 128 | Providing and fixing GI pipes complete with GI fittings i/c trenching and refilling etc. (external work). A) 25mm dia nominal bore a) 25 mm diameter |
| 129 | Making connection of GI distribution branch with GI main of following sizes by providing & fixing Tee, i/c cutting and threading the pipe etc complete: a) 25 to 40 mm nominal bore |
| 130 | Providing and fixing C.P. brass shower rose with 15 mm or 20 mm inlet:100 mm diameter |
| 131 | Providing and fixing brass bib cock of approved quality: 20 mm nominal bore |
| 132 | Providing and fixing brass stop cock of approved quality: 20 mm nominal bore |
| 133 | (SH: Construction of Security Tower)Annexure-IV |
| 134 | Earthwork in excavationbymechanical means ( Hydraulic Excavator)/ manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. All kinds of soil. |
| 135 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer cum by ramming and watering lead upto 50 m and lift upto 1.5 m |
| 136 | Providing and laying in position cement concreteof specified grade excluding the cost of centering & shuttering. All works upto plinth level. a)1 : 4 : 8(1 Cement: 4 coarse sand: 8 graded stone aggregate: 40 mm nominal size). |
| 137 | Reinforcement for R.C.C. work i/c.straightening, cutting, bending, binding ,placing in position and bindingall complete in TMT bars. |
| 138 | Providing and laying in position specified grade of reinforced cement concrete workexcluding cost of centering, shuttering and reinforcement- All work up to plinth level: 1:1.5:3 (1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) |
| 139 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 3.2.21:1.5:3 ( 1 cem : 1.5 c/sand : 3 graded stone aggregate 20 mm nom size ) |
| 140 | Reinforced cement concrete work inbeams, suspended floors, roofs having slope up to 15olandings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishingandreinforcement, with 3.3.1in 1:1.5:3 ( 1 cem : 1.5 c/sand : 3 graded stone aggregate 20 mm nominal size ). |
| 141 | Centering & shuttering including strutting & propping etc.& removal of form for: (a) Foundation, footings, bases of columns etc. for mass concrete. |
| 142 | B) Lintels ,beams,plinth beams ,girders, bressumers and cantilevers |
| 143 | C) Columns ,Pillars,Piers,Abutments, Posts and Struts. |
| 144 | d) Suspended floors, roofs, landings, balconies and access platform |
| 145 | (e) Edges of slab and breaks in floors and walls(i) under 20 cm wide |
| 146 | Brick work with 1st class common burnt clay F.P.S (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 147 | Half brick masonary with 1st class common burnt clay F.P.S (non modular) bricks in superstructure above plinth level upto V level in a) Cement mortar 1:4 (1 cement : 4 c/sand) |
| 148 | 12 mm cement plaster finishedwith a floating coat of neat cement of mix1:4 (1 cement: 4 coarsesand). |
| 149 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption\"s less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the jointts with white cement and matching pigmentsetc. complete. Size of Tile 600 x 600 mm. |
| 150 | Providing and laying vitrified tiles in different sizes (thickness to be specified by the manufacturer) with water absorption\"s less than 0.08% and conforming to IS:15622 of approved make in all colours and shades, in skirting, riser of steps over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigmentsetc. complete. Size of Tile 600 x 600 mm. |
| 151 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 152 | Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface-Water thinnable cement primer |
| 153 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufactures specifications: Two or more coats applied @1.25 ltr/10 sqm over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 154 | Steel work in built up tubular (round, square or rectangular tubes etc.) trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including wilding and bolted including special shape washer etc. Complete.(a) Electric resistant or induction butt welded tubes |
| 155 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.l. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.1. 1.00mm thick with zinc coating not less than 275gm/m2 |
| 156 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete. 12.4.1. 0.80mm thick with zinc coating not less than 275gm/m2 |
| 157 | (SH: Improvement of approach road)Annexure-V |
| 158 | D) Granular Base/Sub-Base with naturally occuring Sand Gravel material Providing laying and compacting Granular Base/Sub baseaccording to lines, grades and cross sections by using naturally occurred Sand Gravel/confrming to IRC- Grd - II of MOST Specification free from organic or other deleterious constituent spread with motor grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness) i/c rolling of the road surface to proper level and grades 30 cm width edging on both sides etc. complete as directed by Engineer-in-charge. |
| 159 | Providing, Laying, Spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel steel/ vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening, binding materials to fill up the interstices of Coarse aggregate, watering and compacting to the required density.i) Grading - I |
| 160 | ii) Grading - II |
| 161 | A) Prime Coat on WMM/WBM(i) P&A primer coat with bitumen emulsion on prepared surface of granular base i/c clearing of road surface and sprayung primer @ 0.7 kg/sqm using mechanical means |
| 162 | P&A tack coat with bitumen emulsion using emulsion pressure distributor @ 0.20 kg/sqm on the prepared bituminous/ granular surface clean with mechanical brooms |
| 163 | Open graded premix surfacing (Providing laying and rolling of open graded premix surfacing of 20 mm thckness composed of 13.2 mm to 5.6 mm aggregates using viscosity grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades) ii) Case -II: Using penetration grade bitumen and hot bitumen mixer 0.5cum. |
| 164 | Seal Coat (providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A seal coats |
| 165 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge. |
| 166 | (SH:Construction of Compound Fencing and line drain)Annexure-V |
| 167 | Earthwork in excavationbymechanical means ( Hydraulic Excavator)/ manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. All kinds of soil. |
| 168 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer cum by ramming and watering lead upto 50 m and lift upto 1.5 m |
| 169 | Providing and laying in position cement concreteof specified grade excluding the cost of centering & shuttering. All works upto plinth level. a)1 : 4 : 8(1 Cement: 4 coarse sand: 8 graded stone aggregate: 40 mm nominal size). |
| 170 | Reinforcement for R.C.C. work i/c.straightening, cutting, bending, binding ,placing in position and bindingall complete in TMT bars. |
| 171 | Providing and laying in position specified grade of reinforced cement concrete workexcluding cost of centering, shuttering and reinforcement- All work up to plinth level: 1:1.5:3 (1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) |
| 172 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 3.2.21:1.5:3 ( 1 cem : 1.5 c/sand : 3 graded stone aggregate 20 mm nom size ) |
| 173 | Reinforced cement concrete work inbeams, suspended floors, roofs having slope up to 15olandings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishingandreinforcement, with 3.3.1in 1:1.5:3 ( 1 cem : 1.5 c/sand : 3 graded stone aggregate 20 mm nominal size ). |
| 174 | Centering & shuttering including strutting & propping etc.& removal of form for: (a) Foundation, footings, bases of columns etc. for mass concrete. |
| 175 | B) Lintels ,beams,plinth beams ,girders, bressumers and cantilevers |
| 176 | C) Columns ,Pillars,Piers,Abutments, Posts and Struts. |
| 177 | Brick work with 1st class common burnt clay F.P.S (non modular) bricks in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 178 | Half brick masonary with 1st class common burnt clay F.P.S (non modular) bricks in superstructure above plinth level upto V level in a) Cement mortar 1:4 (1 cement : 4 c/sand) |
| 179 | 15 mm cement plaster 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall. |
| 180 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.(a)Using flats 30x6mm for diagonal braces and central cross piece. |
| 181 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying coat of approved steel primer all complete. |
| 182 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: (i) Two or more coats on new work over an under coat of suitableshade withordinary paint of approved brand and manufacture. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail