| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 2 | Providing and Laying of Stone Soling hand packed including ramming, dressing and watering etc. with all cost and carriage of materials upto site of work complete. |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 7 | Backfilling with 2nd class sand/ stone dust/ boulders inside plinth including watering, ramming, rolling etc including all carriages complete. |
| 8 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 9 | Providing wood work in frames of doors. Windows, arch windows, ventilators, wrought frames (chowkats) and other frames, wroutht framed and fixed in position with all necessary fitting/ fixtures complete. First Class KD wood. |
| 10 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 14 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position angles/ flats/ tubles including MS sheet for cheeja, soffits and eaves boarding and applying a priming coat of approved steel primer all complete. |
| 15 | Providing and fixing with Colour coated High rib profile sheet roofing including vertical/curved surface including polymer coated J. or L hooks,fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface) excluding the cost of purlins, rafters complete as per the directions of Incharge Engineer. 0.50mm thick including carriages by mt |
| 16 | Providing ridges, hips and valleys of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 17 | Providing and Applying of 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 18 | Providing and applying of 1mm thick white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 19 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 20 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 21 | Providing and fixing of 35mm thick Imported KD Wood glazed shutters for doors, windows and clerestory windows including ISI marked M.S pressed Butt Hinges bright finished of required size with necessary screws other fittings/ fixtures and glazing for window shutters complete as per the directions of Incharge Engineer. |
| 22 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Ply wood 5 ply, 9 mm thick Decorative ply wood both side decorative veneer (type 1) conforming to IS 1328 BWR type |
| 23 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 25 | Providing and fixing of ISI marked Aluminium fittings of standard quality and make for doors and windows of following size including screws, nails etc complete. |
| 26 | Handles 150mm |
| 27 | Handles 100mm |
| 28 | Hooks 150mm |
| 29 | Concealed Locks 200mm (Link lock type of approved brand and make.) |
| 30 | Tower Bolts 150mmx 10mm |
| 31 | Tower Bolts 100mmx 10mm |
| 32 | Providing and Fixing of Heavy duty glass panes 3.5mm thick instead of ordinary glass panes 13.75kg/sqm in doors, windows and clerestory window shutters (Area of opening for glass panes excluding portion inside shall be measured) including cost of beadings nails etc complete. |
| 33 | Providing and fixing of 8mm thick ply wood in room ceiling including supporting structure 3\"x3\" wooden joists and 50x 50mm wooden cornice at corners and where ever required, beadings nails and other fittings fixtures complete as per the directions of Incharge Engineer. |
| 34 | Providing and fixing of Imported KD joists in rooms, chejja and fixed in position with all necessary fitting/ fixtures complete. |
| 35 | Providing and Laying of Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20 mm nominal size stone aggregate. |
| 36 | Lighting point (one lighting point includes wiring of lighting point in 1.5 sq.mm PVC insulated copper wire and 2.5 sq.mm PVC insulated multistrand copper wire,6 amp one way swittch6 amp S pole MCB,10 amp DP MCB,2 way DB MCB and hylem sheet with 16/15 Watt LED surface lights.including cost of channelsas per requirement.One point controlled by one 6 amp switch.( upto 10 meters)including Placing and fixing in position 25mm PVC Conduit pipes with necessary bends and other fittings in RCC Work including cost of service line. |
| 37 | Heating point (one heatting point includes wiring of lighting point in 2.5 sq.mm PVC insulated copper wire and 4.00 sq.mm PVC insulated multistrand copper wire,16 amp one way swittch,10 amp S pole MCB,2 way DB MCB and hylem sheet.including Placing and fixing in position deep junction of cast iron with network Conduit pipes with necessary fittings in RCC Work. |
| 38 | Carriage of materials from approved source to site of work complete. |
| 39 | Stone aggregate for an average lead of 10Kms |
| 40 | Sand for an average lead of 10Kms |
| 41 | Bricks for an average lead of 60Kms. Please Enable Macros to View BoQ information |