| Sl. No. | Item Description |
| 1 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 averagecompressive strength in super structure above plinth level up to floor V level in : |
| 2 | Cement mortar 1:4 (1 Cement : 4 coarse sand) (DSR 6.34.1/2023) |
| 3 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR 8.31/2023) |
| 4 | Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875-1987, ISO 800-1984 and IS:801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software |
| 5 | such as Frame CAD Pro-11.7/ STAAD PRO- V8i/ArchitekV2.5.16/ Revit architecture-2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39 mm flange x 11 mm lip in required length as per structural design requirement duly punched with dimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250 mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall |
| 6 | have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20 mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12 mm diameter and 121 mm length conforming to AISI 304 and 316 at 500 mm c/c with minimum embedment of 100 mm in RCC (RCC to be paid separately) and located not more than 300 mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT. The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. (DSR 26.41/2023) |
| 7 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 8 | 25 mm thick. (DSR 11.26.1/2023) |
| 9 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR 11.27/2023) |
| 10 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete. (DSR 11.40/2023) |
| 11 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including grouting the joints with white cement and matching pigments etc., The tile must be cut with zero chipping diamond cutter only, laying of tile will be done with the notch trowel, plier, wedge, clips of required thickness, Levelling system and rubber mallet for placing the tiles gently and easily. (DSR 11.41A/2023) |
| 12 | Double Charge Vitrified Tile of Polished finish of size |
| 13 | Size of Tile 600 x 600 mm (DSR 11.41A.1.2/2023) |
| 14 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 15 | Size of Tile 600 x 600 mm (DSR 11.46.2/2023) |
| 16 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from -Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39 mm flange x 11 mm lip in required length as per structural design requirement duly punched with dimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250 mm away from both ends of the member. The frame can be supplied in panelized or knock dow |
| 17 | GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum),including factory painted after bending. (DSR 11.52.1/2023) |
| 18 | Providing and f1Xing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange f1Xed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channelwith connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction-Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39 mm flange x 11 mm lip in required length as per structural design requirement duly punched with dimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250 mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. (DSR 12.45/2023) |
| 19 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011(Boardwith BIS certification marks) (DSR 12.45.1/2023) |
| 20 | 6 mm cement plaster to ceiling of mix : |
| 21 | 1:3 (1 Cement : 3 fine sand) (DSR 13.16.1/2023) |
| 22 | 12 mm cement plaster of mix : |
| 23 | 1:4 (1 cement: 4 coarse sand)(DSR 13.4.1/2023) |
| 24 | 15mm cement plaster of mix : |
| 25 | 1:4 (1 cement: 4 coarse sand)(DSR 13.5.1/2023) |
| 26 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80/2023) |
| 27 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 28 | Two coats (DSR 13.82.2/2023) |
| 29 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 30 | For fixed portion |
| 31 | Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2/2023) |
| 32 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 33 | Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2/2023) |
| 34 | Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 |
| 35 | Upto 20 mm depth and 20 mm width (DSR 21.19.3/2023) |
| 36 | Providing and fixing ISi marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessaryscrews etc. complete: |
| 37 | 100x63x4 mm (DSR 9.95.4/2023) |
| 38 | Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessaryscrews etc. complete : |
| 39 | 150x10 mm (DSR 9.97.4/2023) |
| 40 | Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 41 | 125 mm (DSR 9.100.1/2023) |
| 42 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 43 | With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (DSR 21.3.1/2023) |
| 44 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : |
| 45 | First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. |
| 46 | Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 47 | (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions ofpipes and masonry with polymer mixed slurry.) (DSR 22.5/2023) |
| 48 | SANITARY INSTALLATIONS & C.P FITTINGS |
| 49 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 50 | W.C. pan with ISI marked white solid plastic seat andlid (DSR 17.2.1/2023) |
| 51 | Providing and fixing white vitreous china oval shape wash basin (counter top) of size 560x400mm withC.I. brackets/rag bolt of required size, 32 mm C. P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making |
| 52 | Oval shape wash basin (counter top) of size560x400mm MR |
| 53 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR 17.31/2023) |
| 54 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge (DSR 17.80/2023) |
| 55 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as perdirection of Engineer-in-charge and finished |
| 56 | Granite Stone of approved shade (DSR 8.10/2023) |
| 57 | Providing and fixing unplasticised PVC connectionpipe with brass unions |
| 58 | 45 cm length |
| 59 | 15 mm nominal bore (DSR 18.21.1/2023) |
| 60 | Providing and fixing in position best Indian HealthFaucet with 8mm dia 1 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall). MR |
| 61 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 15mm nominal bore (DSR 18.53.1/2023) |
| 62 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved makeconforming to IS: 8931. 15 mm nominal bore (DSR 18.52.1/2023) |
| 63 | Providing and fixing CP Brass 40 mm size Bottle Trapof approved quality & make and as per the direction of Engineer-in-charge MR |
| 64 | Providing and fixing toilet paper holder : C.P. brass (DSR 17.34.1/2023) |
| 65 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (DSR 17.71/2023) |
| 66 | Providing & fixing Silent S.W.R Pipe (HSN Code 3917)Anlysis Rate |
| 67 | 110 mm dia Pipe |
| 68 | 75 mm dia Pipe |
| 69 | Providing & fixing Silent S.W.R PVC Fitting (HSN Code 3917) Anlysis Rate |
| 70 | 110x110 mm dia P- Trap |
| 71 | 110 mm dia Door-T |
| 72 | 110 mm dia Door-Elbow |
| 73 | 110 mm dia Elbow |
| 74 | 75 mm dia Elbow |
| 75 | 110 mm dia Socket |
| 76 | 75 mm dia Socket |
| 77 | 110 mm dia Single Y |
| 78 | 110x75 mm dia Single Y |
| 79 | 111 mm dia 45degree bend |
| 80 | Providing & fixing Silent S.W.R Pipe (HSN Code 3917)Anlysis Rate |
| 81 | 160 mm dia SWR PVC Pipe 10 kg Pressure |
| 82 | 110 mm dia SWR PVC Pipe 10 kg Pressure |
| 83 | P/F Silent SWR PVC Fitting 10 kg Pressure |
| 84 | 110 mm dia Elbow 45 Degree/90 Degree /door bend 90degree |
| 85 | 110 mm dia socket |
| 86 | Tee 110x110 mm |
| 87 | Y- 160x110 mm |
| 88 | Elbow - 160x160 |
| 89 | Clean out plug 160 mm |
| 90 | Clean out plug 110 mm |
| 91 | Socket 160 mm |
| 92 | Plain tee 160 mm |
| 93 | Cutting holes up to 30x30 cm in walls including making good the same: With With common burntclay F.P.S. (non modular) bricks (DSR 18.76/2023) |
| 94 | Cutting holes up to 15x15 cm in R.C.C. floorsandroofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof (DSR 18.77/2023) |
| 95 | Providing and fixing UPVC pipes complete with fittings and clamps, including cutting and making good walls etc. ( for wash basin & Urinalwaste ) |
| 96 | 40 mm dia nominal bore MR |
| 97 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the |
| 98 | 100mm dia pipe. (DSR 12.38.1/2023) |
| 99 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring.(i) Double socketed pipes. MR |
| 100 | 160 mm MR |
| 101 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. |
| 102 | g) Providing & fixing UPVC Coupler |
| 103 | i) 160mm dia MR |
| 104 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : |
| 105 | 100 mm (DSR 12.38.1/2023) |
| 106 | 150 mm (DSR 12.38.2/2023) |
| 107 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 108 | Concealed work including cutting chases and makinggood the walls etc. |
| 109 | 20mm dia nominal outer dia pipes (DSR 18.8.2/2023) |
| 110 | 25mm dia nominal outer dia pipes (DSR 18.8.3/2023) |
| 111 | 32mm dia nominal outer dia pipes (DSR 18.8.4/2023) |
| 112 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.. (DSR 18.7/2023) |
| 113 | 20mm dia nominal bore (DSR 18.7.2/2023) |
| 114 | 25mm dia nominal bore (DSR 18.7.3/2023) |
| 115 | 32mm dia nominal bore (DSR 18.7.4/2023) |
| 116 | 40mm dia nominal bore (DSR 18.7.5/2023) |
| 117 | 50mm dia nominal bore (DSR 18.7.6/2023) |
| 118 | 65mm dia nominal bore (DSR 18.9.7/2023) |
| 119 | Providing and fixing gun metal gate valve with wheelof approved quality. |
| 120 | 20mm dia nominal bore (DSR 18.17.1A/2023) |
| 121 | 25mm dia nominal bore (DSR 18.17.1/2023) |
| 122 | 32mm dia nominal bore (DSR 18.17.2/2023) |
| 123 | 40mm dia nominal bore (DSR 18.17.3/2023) |
| 124 | 50mm dia nominal bore (DSR 18.17.4/2023) |
| 125 | 65mm dia nominal bore (DSR 18.17.5/2023) |
| 126 | Providing and fixing Butterfly Valve with IP 54 actuator with Control Panel and Two Point Magnetic Sensor for Automated Tank Filling System |
| 127 | 25 mm nominal bore (MR) |
| 128 | 32 mm nominal bore (MR) |
| 129 | 40 mm nominal bore (MR) |
| 130 | 50 mm nominal bore (MR) |
| 131 | 65 mm nominal bore (MR) |
| 132 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. |
| 133 | Capcity in Per Liters (DSR 18.48/2023) |
| 134 | Supply installation, testing and commissioning of water cooler Cooling Capacity150Ltrs. / Hrs.,Storage Capacity 150 Ltrs (MR) |
| 135 | (C) Electrical WORK |
| 136 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 137 | (GROUP C) (DSR 1.10.3/2022) |
| 138 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 139 | (GROUP C) (DSR 1.55.3/2022) |
| 140 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed pvc conduit as required. |
| 141 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (DSR 1.14.1/2022) |
| 142 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (DSR 1.14.2/2022) |
| 143 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire (DSR 1.14.3/2022) |
| 144 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire (DSR 1.14.9/2022) |
| 145 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire (DSR 1.14.10/2022) |
| 146 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire (DSR 1.14.11/2022) |
| 147 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (DSR 1.31/2022) |
| 148 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and15/16 A modular switch, connections etc. as required. (DSR 1.32/2022) |
| 149 | Supplying and fixing 63 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 63 amps \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (MR) |
| 150 | Supplying and fixing of following sizes of steel conduit along with accessories insurface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required (DSR 1.20/2022) |
| 151 | 25mm dia conduit (DSR 1.20.2/2022) |
| 152 | 32mm dia conduit (DSR 1.20.3/2022) |
| 153 | Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR 1.21/2022) |
| 154 | 20mm dia conduit (DSR 1.21.1/2022) |
| 155 | 25mm dia conduit (DSR 1.21.2/2022) |
| 156 | 32mm dia conduit (DSR 1.21.3/2022) |
| 157 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copperconductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. (DSR 1.18/2022) |
| 158 | 2 Pair (DSR 1.18.2/2022) |
| 159 | 4 Pair (DSR 1.18.3/2022) |
| 160 | Supplying and fixing following modular switch/ socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required. |
| 161 | 5/6 A switch (DSR 1.24.1/2022) |
| 162 | 2 way 5/6 A switch (DSR 1.24.2/2022) |
| 163 | 15/16 A switch (DSR 1.24.3/2022) |
| 164 | 3 pin 5/6 A socket outlet (DSR 1.24.4/2022) |
| 165 | 6 pin 15/16 A socket outlet (DSR 1.24.5/2022) |
| 166 | Telephone socket outlet (DSR 1.24.6/2022) |
| 167 | Supplying and fixing following size/modules, GI box along with modular base and coverplate for modular switches in recess etc. as required. (DSR 1.27/2022) |
| 168 | 1 or 2 Module (75mm x 75mm) (DSR 1.27.1/2022) |
| 169 | 3 Module (125mmX75mm) (DSR 1.27.2/2022) |
| 170 | 4 Module (125mmX75mm) (DSR 1.27.3/2022) |
| 171 | 6 Module (200mmX75mm) (DSR 1.27.4/2022) |
| 172 | 8 Module (125mmX125mm) (DSR 1.27.5/2022) |
| 173 | 12 Module (200mmX150mm) (DSR 1.27.6/2022) |
| 174 | Supplying and fixing modular blanking plate on the existing modular plate & switch boxexcluding modular plate as required. (DSR 1.26/2022) |
| 175 | Supply & fixing of PVC raceways for following sizes with all accessories like coupler,bends,risers and fixing brackets along with covering complete in all respect equivalent to Legrand Model 0896 (MR) |
| 176 | 100 mm X 38 mm, 2 Compartment PVC Race ways |
| 177 | 150 mm X 38 mm, 3 Compartment PVC Race ways |
| 178 | 300 mm X 38 mm, 3 Compartment PVC Race ways |
| 179 | Supply & fixing of GI raceways for following sizes with all accessories like coupler,bends,riser and fixing brackets along with covering complete in all respect (MR) |
| 180 | 100 mm X 38 mm, 1 Compartment GI Race ways |
| 181 | 150 mm X 38 mm, 1 Compartment GI Race ways |
| 182 | 225 mm X 38 mm, 3 Compartment GI Race ways |
| 183 | 300 mm X 38 mm, 3 Compartment GI Race ways |
| 184 | Junction Box with option 4 Module mounted on race way with adjustable option for followingsizes along with cover plate etc complete in all respect. Make Legrand (MR) |
| 185 | 150X150X65 |
| 186 | 225X225X65 |
| 187 | Supply and fixing of GI Floor Box with 3 Compartments (300X300 mm) height 86 mm withCover with and provision of cable entry complete in all respect (MR) |
| 188 | Supplying and fixing metal box of following sizes (nominal size) in floor, surface or in recesswith suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 189 | 100 mm X 100 mm X 60 mm deep (DSR 1.22.2/2022) |
| 190 | 150 mm X 150 mm X 60 mm deep (DSR 1.22.3/2022) |
| 191 | 200 mm X 300 mm X 60 mm deep (DSR 1.22.13/2022) |
| 192 | Supply and fixing of recess/ Surface mounted round 6 W LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect including connection with 1.5 sqmm FRLS PVC insulated copper (MR)conductor |
| 193 | Supply and fixing of recess/ Surface mounted round or square 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect including connection with 1.5 sqmm FRLSPVC insulated copper conductor (MR) |
| 194 | Supply and fixing of 36 Watt indoor Recess/surface mounting LED Square Fittingwith Powder coated die cast aluminium housing body with extended heat sink and full diffuser of Special Polycarbonate meterial and driver set complete in all respect including connection with 1.5 sqmm FRLS PVC insulated copper conductor (MR) |
| 195 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 20 watt LED tube light fitting including tube on Surface complete in all respect including connection with 1.5 sqmm FRLS PVC insulated copper conductor (MR) |
| 196 | Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection complete in all respect including connection with 1.5 sqmm FRLS PVC insulated copper conductor (MR) |
| 197 | Supply and fixing of Single LED light wall bracket 3 to 6 Watt on matching M.D.F.E.G Board base etc. complete in all respect including connection with 1.5 sqmm FRLS PVC insulated copper conductor (MR) |
| 198 | Supply and fixingof Mirror Wall Light oblong 10 Watt LED luminaire with driver set confirming to IP 65 and above Protection . complete in all respect including connection with 1.5 sqmm FRLS PVC insulated copper conductor |
| 199 | Supply, installation, connecting, testing and commissioning of illuminated exit sign with 1 x 6 watt LED lamp including providing maintenance free batteries & charger capable of working for 2 hr duration mounted on ceiling/wall complete with the approved EXIT self adhesive labels as per site requirement as required including connection with 1.5 sqmm FRLS PVC insulated copper conductor (MR) |
| 200 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 201 | Supplying, erection, connecting, testing and commissioning of 400 mm wall fan completein all respect including fixing wiring connection including connection with 1.5 sqmm FRLS PVC insulated copper conductor (MR) |
| 202 | Supplying, erection, connecting, testing and commissioning of following size exhaust fancomplete with gravity louver and connection with 3 core flexible wire as required. (MR) |
| 203 | 380mm 900 RPM |
| 204 | 450mm 900 RPM |
| 205 | Supply and fixing of single unit LED aviation obstruction light complete with transformerand LED spiral etc complete in all respect (MR) |
| 206 | Add extra to item (1116) for 15cm or part thereof for room height from 3.5 to 5.00 metres. |
| 207 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts, nutsand washers etc., complete in all respect. (MR) |
| 208 | Making hole in the wall for exhaust fan and finishing properly complete in all respect. (MR) |
| 209 | Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of thework. (MR) |
| 210 | Supplying and fixing M.S. box with Phenolic laminate plate 4- way splitter box for TVantenna complete as required. (MR) |
| 211 | Supplying and fixing of 450 x 450 x 150 M.S. box with Phenolic laminate plate of 16 SWGM.S. Sheet with hinged door cover for mounting TV amplifier including wooden base plate complete as required. (MR) |
| 212 | Supplying and fixing of following ways,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess ,complete with tinned copper bus bar, neutral link, earth bar, din bar,interconnections, powder painted including earthing etc.as required. ( But without MCCB/MCB/RCCB) |
| 213 | 4 way Double door (DSR 2.4.1/2022) |
| 214 | 6 way Double door (DSR 2.4.2/2022) |
| 215 | 8 way Double door (DSR 2.4.3/2022) |
| 216 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCCBs (but without MCCB and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 217 | 4 way Double door (DSR 2.5.1/2022) |
| 218 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (DSR 2.11/2022) |
| 219 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DBcomplete with connections, testing and commissioning etc. as required. |
| 220 | 40 A (DSR 2.13.1/2022) |
| 221 | 63 A (DSR 2.13.2/2022) |
| 222 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board includingdrilling holes in cubicle panel, making connections, etc. as required. (DSR 2.2/2022) |
| 223 | S & F 100 amp. FP MCCB (16KA) Thermal Magnetic Release (DSR 2.2.1/2022) |
| 224 | S & F 150 amp. FP MCCB (16KA) Thermal Magnetic Release (DSR 2.2.3/2022) |
| 225 | S & F 250 amp. FP MCCB (25KA) Thermal Magnetic Release (DSR 2.2.6/2022) |
| 226 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 227 | Single pole (DSR 2.10.1/2022) |
| 228 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existingMCB DB complete with connections, testing and commissioning etc. as |
| 229 | 25 A (DSR 2.14.1/2022) |
| 230 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 231 | 25 A (DSR 2.15.1/2022) |
| 232 | 40 A (DSR 2.15.2/2022) |
| 233 | 63 A (DSR 2.15.3/2022) |
| 234 | Supplying, installation, testing and commissioning of cubical type MV Panel made out of 14 SWG CRCA sheet steel, totally enclosed IP-54 protection, free standing, floor mounted dust and vermin proof, indoor type compartmentalized powder coated of approved shade after antirust treatment (with min seven tanks ) suitable with busbar interconnection with suitable size of copper lead/solid Aluminium strips, control circuits & bottom base channel of MS section not less than 100mmx50mmx5mm (thick), Fabrication shall be done in transportable section ,entire panel shall have a common earth busbar at rear with 2 nos earth stud cable alleys, cable gland plates in two half as required as per single line diagram & specification enclosed with the following switch gears (MR) |
| 235 | NOTE: |
| 236 | All MCCBs shall have Ics=Icu=100% |
| 237 | MCB Should be connected throught terminal Strip of suitable rating |
| 238 | All outgoing MCCB feeders shall have ON/OFF Trip indication lights (LED Type) |
| 239 | Panel Specification as stated above (Light Panel) |
| 240 | Incomer |
| 241 | 1 No. 125 A FP MCCB (36 KA) |
| 242 | 1 Set phase indication lights (R, Y, B) |
| 243 | 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. |
| 244 | 1 No. 0-160 Amp. Ammeter (digital type) with inbuilt ASS |
| 245 | BUS BARS:- |
| 246 | 200 Amps. TP&N aluminium bus bars (36 KA) |
| 247 | OUT GOINGS:- |
| 248 | 6 Nos 40 Amp. FP MCB (25 KA) |
| 249 | 3 Nos.100 Amps. FP MCCB (25KA) (MR) |
| 250 | Panel Specification as stated above (Power Panel) (MR) |
| 251 | Incomer |
| 252 | 1 No. 160 A FP MCCB (36 KA) |
| 253 | 1 Set phase indication lights (R, Y, B) |
| 254 | 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. |
| 255 | 1 No. 0-160 Amp. Ammeter (digital type) with inbuilt ASS |
| 256 | BUS BARS:- |
| 257 | 200 Amps. TP&N aluminium bus bars (36 KA) |
| 258 | OUT GOINGS:- |
| 259 | 6 Nos 63 Amp. FP MCB (25 KA) |
| 260 | 1 Nos.100 Amps. FP MCCB (25KA) |
| 261 | Panel Specification as stated above (UPS Panel) (MR) |
| 262 | Incomer |
| 263 | 1 No. 160 A FP MCCB (36 KA) |
| 264 | 1 Set phase indication lights (R, Y, B) |
| 265 | 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. |
| 266 | 1 No. 0-160 Amp. Ammeter (digital type) with inbuilt ASS |
| 267 | BUS BARS:- |
| 268 | 200 Amps. TP&N aluminium bus bars (36 KA) |
| 269 | OUT GOINGS:- |
| 270 | 4 Nos 63 Amp. FP MCB (25 KA) |
| 271 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (DSR 5.4/2022) |
| 272 | Earthing with G.I. earth pipe 4.5 metre long,40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required. (DSR 5.2/2022) |
| 273 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc.as required. (DSR 5.15/2022) |
| 274 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. (DSR 5.11/2022) |
| 275 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in surface or in recess for loop earthing as required (DSR 5.16/2022) |
| 276 | Earthing with G.I. earth pipe 4.5 metre long,40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR 5.2/2022) |
| 277 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) (DSR 6.7/2022) |
| 278 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. (DSR 6.2/2022) |
| 279 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall forlightning conductor complete as required. (For vertical run) (DSR 6.8 /2022) |
| 280 | Supply and lying of 32mm x 6 mm G.I. strip from earth electrode directly in the ground asrequired complete in all respect. (MR) |
| 281 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. (DSR 6.12/2022) |
| 282 | Supply,Installation,testing Commissioning of Below described lifts complete as perspecification and as per direction of Engg-In Charge |
| 283 | 13 P (884 KG) (MRL) Lift with speed of 1.5 M/Sec., travel of 5th to 7th floor:3Stop/3 Open,power operated center opening doors, ACVVVF Control, and automatic rescue operation during power failure. (dimensions and travelling as per drawing) (MR) |
| 284 | Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 7 Feet for Data as per given Specification etc. all complete.Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 285 | Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 4 Feet for Data Jack Panel end as per given Specification etc. all complete.Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 286 | Supply, Installation, Testing & Commissioning of Cat-6A, 24 Port Jack Panel for data as per given Specification etc. all complete.Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 287 | Supply, Installation, Testing & Commissioning of Cat-6A Mounting Cords 4 Feet for Voice Jack Panel end as per given Specification etc. all complete.Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 288 | Supply, Installation, Testing & Commissioning of Cat-6A 24 Port Jack Panel for Voice Field as per given Specification etc. all complete.Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 289 | Supply, Installation, Testing & Commissioning of Cat-6A 24 Port Jack Panel for Voice Field & Resource as per given Specification etc. all complete.Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 290 | Supply, Installation, Testing & Commissioning of 15 U Wall Mount Rack as per given Specification etc. all complete.Make: Rittal / Valrack/ APW / Netrack (MR) |
| 291 | Supply, Installation, Testing & Commissioning of 300 Pair MDF Box with Mounting Frame as per given Specification etc. all complete.Make: NetRack / Krone / APW / Actassi (MR) |
| 292 | Supply, Installation, Testing & Commissioning of 10 Pair Krone Module as per given Specification etc. all complete.Make: NetRack / Krone / APW / Actassi (MR) |
| 293 | Supply, Installation, Testing & Commissioning of 25 Pair Riser cable as per given Specification etc. all complete.Make: Delton / Skyton / Actassi (MR) |
| 294 | Supply, Installation, Testing & Commissioning of 42 U Wall Mount Rack as per given Specification etc. all complete.Make: Rittal / Valrack/ APW/ Netrack (MR) |
| 295 | Supply, Installation, Testing & Commissioning of 6 Core Multi Mode Fiber ( Armored) Cable as per given Specification etc. all complete.Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 296 | Supply, Installation, Testing & Commissioning of 12 Port Fiber LIU Loaded with SC MM Coupler, as per given Specification etc. all complete.Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 297 | Supply, Installation, Testing & Commissioning of SC MM Pigtail (1.0 Mtr) as per given Specification etc. all complete.Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 298 | Supply, Installation, Testing & Commissioning of 2 port faceplate with Gang Box etc. all complete.Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 299 | Supply, Installation, Testing & Commissioning of LSZH Cat 6A-10G speed unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed/surface conduits/Raceways complete 305 Mtr. Roll as per specification etc. all complete. Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 300 | Supply, Installation, Testing & Commissioning of UTP Cat-6A Information Outlet for Data as per specification etc. all completeMake: 3C3/ Corning / Panduit/ Actassi (MR) |
| 301 | Supply, Installation, Testing & Commissioning of UTP Cat-6A Information Outlet for Voice as per specification etc. all complete.Make: 3C3/ Corning / Panduit/ Actassi (MR) |
| 302 | Supply, Installation, Testing & Commissioning of Access point which can support the given Controller,support 2x2 MIMO for both 802.11ac and 802.11n client,Support data rate of 867 Mbps on 5ghzas per the given Specification etc. all complete.Make- Cisco / Juniper / Allied Telesis (MR) |
| 303 | Supply, Installation, Testing & Commissioning of 24 Port Analouge Card etc. all complete. Make: Panasonic / Avaya / Alcatel Lucent (MR) |
| 304 | Supply, Installation, Testing & Commissioning of High End Digital Key Phone 6x24 Display with 24 Programmable Dual Color LED’s with 4 Feature Access Keys, multi-step Tilt angle adjustment, Navigator Key, backlit display, should have option to connect Blue Tooth etc. all complete.Make: Panasonic / Avaya / Alcatel Lucent (MR) |
| 305 | Supply, Installation, Testing & Commissioning of Low end DIgital Key Phone 1x16 Display with 8 Programmable Dual Color LED’s etc. all complete.Make: Panasonic / Avaya / Alcatel Lucent (MR) |
| 306 | Supply, Installation, Testing & Commissioning of Analog Phone With Speaker , Small Display etc. all complete.Make: Panasonic / Avaya / Alcatel Lucent (MR) |
| 307 | SUBHEAD :IP CCTV System |
| 308 | SITC of IP Dome Camera 4MP IR Dome Camera, Metal Housing, H.265+/H.265/H.264, Up to 2592x1520@25fps, Min. illumination Color: [email protected], Smart IR, IR Range: 30m, Built-in Mic, SD Card Slot, Reset Button, POE, IP67, IK10, 120dB WDR, Support tripwire and perimeter, ANR. BIS,CE,FCC,ROHS,UL/EN. etc all complete.Make: Pelco / Royalshield / Bosch / Axis (MR) |
| 309 | SITC of NVR - H.265 8SATA 64ch NVR, H.265+ Compression, Support 64-ch input, Up to 12MP Resolution Recording, Incoming Bandwidth 320Mbps, Outgoing Bandwidth 320Mbps, HDMI and VGA independent outputs, HDMI Video output at up to 4K (3840 × 2160) resolution, 8 SATA interfaces for 8 HDDs, up to 10TB for each HDD, eSATA interface:- 1 SATA interface, 2xRJ45 self-adaptive 10/100/1000 Mbps network interfaces, VCA detection alarm is supported, Array Type:- JBOD, RAID0/1/5/6/10, 2xUSB 2.0, 1xUSB 3.0, serial Interface:- 2xRS-485, 1xRS-232, No.of Hard Disks 4TB for the calaculation of 1 month recording 2MP@25FPS as per all camera count, VMS should also be included if required etc. all complete.Make: Pelco / Royalshield / Bosch / Axis (MR) |
| 310 | SITC of MS Windows 2008 Server R2 x64, Intel i5 Xeon Quad Core processor, 8 GB RAM, 1TB HDD, 2GB Graphics Card. With CD/DVD player, Mouse and Keyboard etc all complete. Make: HP / Lenevo / Dell (MR) |
| 311 | SITC of 55\" LCD narrow Bazel for Monitoring for each NVR Server etc. all complete.Make: Sony / Panasonic / Aaztec (MR) Please Enable Macros to View BoQ information |