| 1 | Excavation in trenches by mechnical means (hydraulic excavator) not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind ofsoil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, leveling watering and well ramming in layers of soil not exceeding 25cm. |
| 3 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point of rock. |
| 4 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store or staking at site ofsize 15mm dia. |
| 5 | All as per item No 4 above…. But for 20 mm dia |
| 6 | All as per item No 4 above…. But for 25 mm dia |
| 7 | All as per item No 4 above…. But for 40 mm dia |
| 8 | All as per item No 4 above…. But for 50 mm dia |
| 9 | All as per item No 4 above…. But for 80 mm dia |
| 10 | All as per item No 4 above…. But for 100 mm dia |
| 11 | Refixing/laying old steel tubing and connections of 15 mm dia in new or old positons (wall/ ceiling, floor, intrenches etc) threading, rethreading and with necessary fittings all as directed. |
| 12 | All as per item No 11 above…. But for 20 mm dia |
| 13 | All as per item No 11 above…. But for 25 mm dia |
| 14 | All as per item No 11 above…. But for 40 mm dia |
| 15 | All as per item No 11 above…. But for 50 mm dia |
| 16 | All as per item No 11 above…. But for 80 mm dia |
| 17 | All as per item No 11 above…. But for 100 mm dia |
| 18 | Supply and fixing/laying in trenches of steel tube medium grade with all fitting and fixed complete to wall, tubing and ceilings or laid in floor/ trench of size 15mm dia. |
| 19 | All as per item No 18 above…. But for 20 mm dia |
| 20 | All as per item No 18 above…. But for 25 mm dia |
| 21 | All as per item No 18 above…. But for 40 mm dia |
| 22 | All as per item No 18 above…. But for 50 mm dia |
| 23 | All as per item No 18 above…. But for 80 mm dia |
| 24 | All as per item No 18 above…. But for 100 mm dia |
| 25 | Supply and fixing in replacement of gunmetal gate valve with iron wheel screwed both ends for iron pipe and fixed ofsize 15mm dia. |
| 26 | All as per item No 25 above…. But for 20 mm bore |
| 27 | All as per item No 25 above…. But for 25 mm bore |
| 28 | All as per item No 25 above…. But for 40 mm bore |
| 29 | All as per item No 25 above…. But for 50 mm bore |
| 30 | M&L for CI/DI special/fittings suitable for CI/DI flanged/socket ends pipe upto 80 to 150 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch \"Y\" junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint, etc. complete all as specified and as directed, |
| 31 | M&L for CI/DI special/fittings suitable for CI/DI flanged/socket ends pipe upto 200 to 300 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch \"Y\" junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers etc. complete all as specified and as directed. |
| 32 | Taking up old U/S steel hume pipe line or /CI/GI/DI any type water mains pipes, any class,(including all fittings), of size80mm bore ,disconnecting pipes and fittings complete |
| 33 | All as per item No 32 above…. But for 100mm bore |
| 34 | All as per item No 32 above…. But for 150 mm bore |
| 35 | All as per item No 32 above…. But for 200mm bore |
| 36 | All as per item No 32 above…. But for 300mm bore |
| 37 | Relaying only old pipe DI/CI/GIin good condition/pipe taken out from trenches for repairsin any length including fittings etc. of size 80mm bore. |
| 38 | All as per item No 37 above…. But for 100mm bore |
| 39 | All as per item No 37 above…. But for 150mm bore |
| 40 | All as per item No 37 above…. But for200mm bore |
| 41 | All as per item No 37 above…. But for 300mm bore |
| 42 | Supply and fix cast iron pipes with spigot and socket ends centrifugally casted class LA in any length suitable for rubber tytan joint and Laid in trenches ofsize 80mm bore. |
| 43 | All as per item No 42 above…. But for 100mm bore |
| 44 | All as per item No 42 above…. But for 150mm bore |
| 45 | All as per item No 42 above…. But for 200 bore |
| 46 | All as per item No 42 above…. But for 300 bore |
| 47 | Supply and laying in trenches/surfaces200mm bore Ductile iron spigot and socket pipes as per IS:8329/2000 class K9 including EPDM rubber gasket suitable for and including push on rubber gasket joint with inside cement mortar lining and outside zinc bitumen coating complete all as specified and as directed. |
| 48 | Supply and laying in trenches/surfaces150mm bore Ductile iron spigot and socket pipes as per IS:8329/2000 class K9 including EPDM rubber gasket suitable for and including push on rubber gasket joint with inside cement mortar lining and outside zinc bitumen coating complete all as specified and as directed. |
| 49 | Supply and laying in trenches/surfaces100mm bore Ductile iron spigot and socket pipes as per IS:8329/2000 class K9 including EPDM rubber gasket suitable for and including push on rubber gasket joint with inside cement mortar lining and outside zinc bitumen coating complete all as specified and as directed. |
| 50 | Supply and laying in trenches/surfaces80mm bore Ductile iron spigot and socket pipes as per IS:8329/2000 class K9 including EPDM rubber gasket suitable for and including push on rubber gasket joint with inside cement mortar lining and outside zinc bitumen coating complete all as specified and as directed. |
| 51 | M&L for burning out lead joint in position , including removing lead to store / stacked at site to issue under credit and newRun lead jointfor spigot socketcast iron pipes and fitting, including cauking properly and making joint leak proof forsize 80mm bore. |
| 52 | All as per item No 51 above…. But for 100 mm bore |
| 53 | All as per item No 51 above…. But for 150 mm bore |
| 54 | All as per item No 51 above…. But for 200 mm bore |
| 55 | All as per item No 51 above…. But for 300 mm bore |
| 56 | Taking down existing UNSVsluice valve and supply & fix new Sluice valve of rising spindle type (Gear type) PN-1.6 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and oprating wheel ofsize 80mm bore. |
| 57 | All as per item No 56 above…. But for 100mm bore |
| 58 | All as per item No 56 above…. But for 150mm bore |
| 59 | All as per item No 56 above…. But for200 mm bore |
| 60 | All as per item No 56 above…. But for 300 mm bore |
| 61 | M&L for 80mm rubber tyton joints for suitable for sockets and spigot CI pipes including rubber gasket for following size |
| 62 | All as per item No 61 above…. But for 100mm |
| 63 | All as per item No 61 above…. But for 150mm |
| 64 | All as per item No 61 above…. But for200mm |
| 65 | All as per item No 61 above…. But for 300mm |
| 66 | Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box ofsluice valve spindle brass including taking apart and reassembling of 200 MM complete all as specified and directed byEngineer-in-Charge. |
| 67 | Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box ofsluice valve spindle including taking apart and reassembling of 150 MM complete all as specified and directed byEngineer-in-Charge. |
| 68 | Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box ofsluice valve spindle including taking apart and reassembling of 80 MM complete all as specified and directed byEngineer-in-Charge. |
| 69 | M&L in repair of rusted & crack CI water branch connection 80 to 100mm dia by using mechanical joint with connecting all accessoriescomplete all as specified and directed byEngineer-in-Charge. Note :(i)cost ofgasket and nut bolts ,washers\"jointing of materials as required are inclusive in above job.ii)Required T&P for job is provided by the Contractor is deemed to be included in the item rate.(iii)Excavation for pipe is included in job Work. |
| 70 | All as per item No 69 above…. But for size of pipe line 150 mm to 300 mm |
| 71 | M&L for dismantling old wall valve chamber and construction of brick masonary new valve pit chamber of size 900mmx900mmx900mm (internal ) size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6rendering in cement 1:6 finished even smooth using extra cement internally and 20mmthickin CM 1:4and finished fair and even supply and fix 2.00 mm thick MS sheet steel cover fixed on 50mmx50mmx6mm thick angle ironframe embeded in PCC copingwith locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron applyingtwo coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to matchsurrounding complete all as specified and directed. |
| 72 | All as per item No 71 above…. But for chamber of size 1200mmx1200mmx1200mm |
| 73 | Dismantaling of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level). |
| 74 | M&L for Cement concrete 1:2:4 B-2 using 40mm graded stone aggregatein foundations,filling and mass concrete |
| 75 | Supply and fix in replacement of ball valves high pressuremade out of PTMTMake- Prayag/Symet complete with epoxy coated Aluminium rod, high density ball etc of size 15mm bore. |
| 76 | All as per item No 75 above…. But for 20 mm bore |
| 77 | All as per item No 75 above…. But for25 mm bore |
| 78 | M & L for Cleaning and removing all dirt and scale etc from Not exc. 500 Ltrs tank and from the mouths of circulating pipes for the tanks ofcapacity Not exc. 500 Ltrs. |
| 79 | All as per item No 78 above…. But for Not exc. 1000 Ltrs |
| 80 | All as per item No 78 above…. But for Not exc. 2000 Ltrs |
| 81 | S&F in replacement inline automatic water pressure pump, house hold with wall mounting bracket suitable cap 0.5 HP single phase 230voltComplete all as specified and directed( Note- including all fittings and fixtures as required) Make-Crompton/Kirloskar/Grundfos |
| 82 | M&L for repaire inline automatic water pressure pump cap 0.5 HP single phase 230voltComplete including all fittingsand fixtures all as specified and directed. |
| 83 | S&F in repair Mild steel work in Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work con- forming to Fe.290.Gde-E-165 |
| 84 | Testing ofTreated water (Drinking water)sample as per IS - 10500 including collecting of sample from the pump house and handed over it to the authoriesed lab for the testing purpose all as specified and directed. |
| 85 | Testing ofRaw watersample as per IS - 10500 including collecting of sample from the pump house and handed over it to the authoriesed lab for the testing purpose all as specified and directed. |
| 86 | Horizontal mechanical trencheless Boring hole for crossing metaled road or footpath for GI/CI pipe of any size and making connection all as directed and specified. |
| 87 | S&F in replacement Air release valve of size 80/100 mm along with rubber washer nuts & bolts etc.Complete all as specified and directed |
| 88 | Disconnection and removing the 60 HP VT pumpset along with section, delivery pipe line,column pipe, control valves,shafts & shafts coupling etc and finding out the unserviceable parts and refixing the disconnected parts after replacing of unserviceable items with new of same size and capacity including testing and commissioning complete all as directed.Note:-Unserviceable parts will be measured and paid separately under respective items of sch \"A\"lubricating oil, Greasing, overhauling and packing kit of pump set including in the unit rate. |
| 89 | Material & labour rewinding of 60 HP VT electric motor with super enamelled winding wire of same gauge weight and turn along with insulating materials such as impregnated paper, cotton tape, varnish etc and keeping the rewinding in to the hot air oven till moisture evaporate and achieving proper insulation results and reassemble the motor including replacement of terminal plate and taking out old winding complete all as directed |
| 90 | Disconnection and removingthe unserviceable Electric motor 120 HP and transporting the same to work shop for rewinding and fixing the same in its original position after repairs, including testing and commissioning complete all as directed |
| 91 | Material & labour rewinding of 120 HP electric motor with fine enameled bared copper conductor of same gauge weight and turn along with insulating materials such as impregnated paper, cotton tap, varnish etc and keeping the rewinding in to the hot air oven till moisture evaporates and achieving proper insulation results and reassemble the motorincluding taking out old rewinding complete all as directed. |
| 92 | Trimming and cutting of tree branches 50mm to 200 mm girth by using automatic hexa machine coming across LT over head line clearing the line around 2m single/both sides and disposal of branches from the site exeeding 50m and not exceeding 250m from site comlete all as directd by engr-in-Charge :- (i) Due care is to be while trimming/cutting the tree branches that there should no damage to over head line conductor/pole /or bldgs. In case due to any negligence, damage is caused to be make good/renewal by the contractor from his own resources and nothing extra is admissible. (ii) All safety to labourer must be adhered by the contractor during trimming and cutting of tree branches |
| 93 | Supply of Electric chain saw machine with 16inch cutting bar for home and professional use, overall length (without bar) 436mm saw chain, pitch 3/8\" high performance , power 1300w chain /bar length 16\" chain speed 12m/s , No load speed 6000/min, chain gauge 1.1 mm all as directed by Engr-In -Charge. |
| 94 | a) Supply & fix of reputeded make full bore SCADA based Electromagnetic flowmeter, size 300mm callibrated with certificate, including all accesseries, cable length- as required, local display- manual reading, remote monitoring- reading see in mobile and laptopand also print last six month hestorical DATA/Excel formate. Enclosser panel- safty Cever Meter, UPS - To Give 3 hours battery backup. With One Year Warranty. b) Supply and installing of all fitting including CI flange addeptor and jointing matterial etc. and commisining of Meter al as directed by Engr-in -Charge. ( Gunjkheda Pump House) |
| 95 | Supply install, testing and commissioningOutdoor Panel Feeder Pillar (CPRI approved) Cubicle type,IP-65,outdoor type confirming to IS: 61439 Part I & II factory fabricated made out ofouter cover with 3 mm thick CRCA sheet & inner cover with 2mm thick CRCA sheet ofsuitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate the incoming MCCB and TPN bus bars and outgoing MCCBs feeders with 4 Hp Star delta motor starter. The TPN busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator at an interval of not more than 500 mm through out the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. The cubicle shall have a bottom and four legs (400mm long) of size 50x 50x6 mm, The panel shall be painted with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, andfixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of followingall as specified and directed by EIC.(a) incoming (i) Aluminium busbar, 4 Pole, 63 Amps (ii) MCCB 4P, 63A, 16 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 No. (iii)Ammeter Digital type, CT operated 0-100A range, (with selector switch and CT) - 01 Set (iv)Volt Meter Digital type 0-500 V range,(With selector switch) - 01 No. (v ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set.(b) Outgoing :- (i) MCB 4P, 63A, 16 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 01 Nos. (ii) MCB TPN, 32A, 10 KA, with thermal magnetic: O/L & S/Cprotection , ICS= 100% ICU= 04 Nos. (iii) Starter for 3 phase 3 to 5Hp cetrifugal motor.(iv) Single phase priventer -01 |
| 96 | Supply and fixing in replacement Onload changeover switch AC-23 (side handle) in sheet enclosure 415 Volt , 50 Hz doublepole 100 Amp all as specified and directed by EIC. |