|
| 1 | Excavation in trenches by mechnical means (hydraulic excavator) not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind ofsoil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, leveling watering and well ramming in layers of soil not exceeding 25cm. |
| 3 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point of rock. |
| 4 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store or staking at site ofsize 15mm dia. |
| 5 | All as per item No 4 above…. But for 20 mm dia |
| 6 | All as per item No 4 above…. But for 25 mm dia |
| 7 | All as per item No 4 above…. But for 40 mm dia |
| 8 | All as per item No 4 above…. But for 50 mm dia |
| 9 | All as per item No 4 above…. But for 80 mm dia |
| 10 | Refixing/laying old steel tubing of size 15mm dia and connections in new or old positons (wall/ ceiling, floor, intrenches etc) threading, rethreading and with fittings all as directed. |
| 11 | All as per item No 10 above…. But for 20 mm dia |
| 12 | All as per item No 10 above…. But for 25 mm dia |
| 13 | All as per item No 10 above…. But for 40 mm dia |
| 14 | All as per item No 10 above…. But for 50 mm dia |
| 15 | All as per item No 10 above…. But for 80 mm dia |
| 16 | Supply and fixing/laying in trenches steel tube medium grade with all fitting and fixed complete to wall, tubing and ceilings or laid in floor/ trench of size 15mm dia. |
| 17 | All as per item No 16 above…. But for 20 mm dia |
| 18 | All as per item No 16 above…. But for 25 mm dia |
| 19 | All as per item No 16 above…. But for 40 mm dia |
| 20 | All as per item No 16 above…. But for 50 mm dia |
| 21 | All as per item No 16 above…. But for 80 mm dia |
| 22 | Supply and fixing in replacement of gunmetal gate valve with iron wheel screwed both ends for iron pipe and fixed ofsize 15mm bore. |
| 23 | All as per item No 22 above…. But for 20 mm bore |
| 24 | All as per item No 22 above…. But for 25 mm bore |
| 25 | All as per item No 22 above…. But for 40 mm bore |
| 26 | All as per item No 22 above…. But for 50 mm bore |
| 27 | M&L for CI special/fittings suitable for CI flanged/socket ends pipe upto 80 to 150 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch \"Y\" junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint, including boring to fit existing pipe line and nut bolts and washers etc. complete all as specified and as directed, |
| 28 | M&L for CI special/fittings suitable for CI flanged/socket ends pipe upto 200 to 300 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch \"Y\" junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint, including boring to fit existing pipe line and nut bolts and washers etc. complete all as specified and as directed, |
| 29 | Taking up old U/S hume pipe line/CI/GI any type water mains pipes, any class,(including all fittings) of size 80mm bore,disconnecting pipes and fittings complete |
| 30 | All as per item No 29 above…. But for 100mm bore |
| 31 | All as per item No 29 above…. But for 150 mm bore |
| 32 | All as per item No 29 above…. But for 200mm bore |
| 33 | All as per item No 29 above…. But for 250mm bore |
| 34 | Relayingonly old pipe in good condition/pipe taken out from trenches for repairsin any length including fittings etc. of size 80mm bore. |
| 35 | All as per item No 34 above…. But for 100mm bore |
| 36 | All as per item No 34 above…. But for 150mm bore |
| 37 | All as per item No 34 above…. But for 200mm bore |
| 38 | All as per item No 34 above…. But for 250mm bore |
| 39 | Supply and fix cast iron pipes with spigot and socket ends centrifugally casted class LA in any length suitable for rubber tytan joint and Laid in trenches of size 80mm bore. |
| 40 | All as per item No 39 above…. But for 150mm bore |
| 41 | All as per item No 39 above…. But for 200 bore |
| 42 | All as per item No 39 above…. But for 250 bore |
| 43 | M&L for rubber tyton joints for suitable for sockets and spigot CI pipes including rubber gasket for size of 80mm. |
| 44 | All as per item No 43 above…. But for 150mm |
| 45 | All as per item No 43 above…. But for 200mm |
| 46 | All as per item No 43 above…. But for250mm |
| 47 | Supply and laying in trenches/surfaces100mm bore Ductile iron spigot and socket pipes as per IS:8329/2000 class K9 including EPDM rubber gasket suitable for and including push on rubber gasket joint with inside cement mortar lining and outside zinc bitumen coating complete all as specified and as directed. |
| 48 | Supply and laying in trenches/surfaces80mm bore Ductile iron spigot and socket pipes as per IS:8329/2000 class K9 including EPDM rubber gasket suitable for and including push on rubber gasket joint with inside cement mortar lining and outside zinc bitumen coating complete all as specified and as directed. |
| 49 | M&L for burning out lead joint in position , including removing lead to store / stacked at site to issue under credit and making new Run lead jointfor spigot socketcast iron pipes and fitting, including cauking properly and making joint leak proof for size of 80mm bore. |
| 50 | All as per item No 49 above…. But for 150 mm bore |
| 51 | All as per item No 49 above…. But for200 mm bore |
| 52 | Taking out old US sluice valves and supply and fix of new sluice valve PN-1.0 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and operating wheel ofsize 80mm boreall as directed. |
| 53 | All as per item No 52 above…. But for 150mm bore |
| 54 | All as per item No 52 above…. But for 200 mm bore |
| 55 | Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box of sluice valve spindle brass including taking apart and reassembling of 200 MM complete all as specified and directed by Engineer-in-Charge. |
| 56 | Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box ofsluice valve spindle including taking apart and reassembling of 150 MM complete all as specified and directed by Engineer-in-Charge. |
| 57 | M&L in repair of rusted & crack CI water branch connection 150 to 300mm dia by using mechanical joint with connecting all accessoriescomplete all as specified and directed byEngineer-in-Charge. Note :(i)cost ofgasket and nut bolts ,washers\"jointing of materials as required are inclusive in above job.ii)Required T&P for job is provided by the Contractor is deemed to be included in the item rate.(iii)Excavation for pipe is included in job Work. |
| 58 | All as per item No 57 above but for 80mm to 100 mm dia |
| 59 | M&L for dismantling old wall valve chamber and construction of brick masonary new valve pit chamber of size 900mmx900mmx900mm (internal ) size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6rendering in cement 1:6 finished even smooth using extra cement internally and 20mmthickin CM 1:4and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mmx50mmx6mm thick angle ironframe embeded in PCC copingwith locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron applyingtwo coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to matchsurrounding complete all as specified and directed. |
| 60 | All as per item No 59 above but for chamber of size 1200mmx1200mmx1200mm |
| 61 | Trimming and cutting of tree branches 50mm to 200 mm girth by using automatic hexa machine coming across LT over head line clearing the line around 2m single/both sides and disposal of branches from the site exeeding 50m and not exceeding 250m from site comlete all as directd by engr-in-Charge :-Note: (i) Due care is to be while trimming/cutting the tree branches that there should no damage to over head line conductor/pole /or bldgs. In case due to any negligence, damage is caused to be make good/renewal by the contractor from his own resources and nothing extra is admissible. (ii) All safety to labourer must be adhered by the contractor during trimming and cutting of tree branches |
| 62 | Supply & fix of reputeded make full bore SCADA based Electromagnetic flowmeter, size 300mm callibrated with certificate, including all accesseries, cable length- as required, local display- manual reading, remote monitoring- reading see in mobile and laptopand also print last six month hestorical DATA/Excel formate. Enclosser panel- safty Cever Meter, UPS - To Give 3 hours battery backup. With One Year Warranty. b) Supply and installing of all fitting including CI flange addeptor and jointing matterial etc. and commisining of Meter al as directed by Engr-in -Charge. ( CMPH and PKT Hill Pump House) |
| 63 | Supply and fixing in replacement Onload changeover switch AC-23 (side handle) in sheet enclosure 415 Volt , 50 Hz doublepole 100 Amp all as specified and directed by EIC. |