| 1 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, complete all as specified and directed |
| 2 | M&L machine cut Granite slab 15 mm thick fixed as in repairs for steps, pillars skirting/dad, window cills, cooking plateforms and like and incl 10mm thick (avg thickness) cement mortar 1:4 screeding and setting coat in cement morter 1:2. 3mm thick, set and jointed with white/coloured cement to match the shade of slab incl cutting, waste, rubbing and polshing etc complete all as specified and directed.Note:- (i) The rate of granite stone shall be deemed to incl for full rounded off comer/edges inci all cutting to make it square or rectangular.(ii) The rate shall also be deemed to incl for cutting and polishing machine and granite polishing to achive the desired granite finish. |
| 3 | M&L Glass mosaic tiles in vertical/floor surface of size 20x20x4 mm fixed with 2 to 3mm thick rubber grout pressed with rubber trowel to remove excess grout, domp sponge and subsequently with dry ray, Including dismantling of old mosaic tiles complete all as specified and directed. |
| 4 | Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out complete all as specified and directed. |
| 5 | All as per item ser No. 4.00 above but in hard/dense soil/cutting of road/hard standing/breaking of PCC etc. |
| 6 | Returning, filling in and including spreading, leveling watering and well ramming in layers in any type of soil not exceeding 25 cm to achieve desired compactness complete all as specified and directed |
| 7 | Removing surplus soil (material) to a distance exceeding 1.5Km and depositing where directed at a level not exceeding 5Km above the starting point complete all as specified and directed. |
| 8 | M&L for Brick work with sub class \"B\" bricks built in CM 1:4 straight or curved on plan exc 6M mean radius including demolition of old unserviceable brick work complete all as specified and directed. |
| 9 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in roof kerbs or mud stops rounded or chamfered on edges etc including demolition of old PCC complete all as specified and directed. |
| 10 | M&L for PCC 1:4:8 Type D2 (using 40 mm graded crushed stone aggregate) in foundations filling and mass concrete including demolition of old PCC complete all as specified and directed |
| 11 | M&L for rendering 10 mm thick on brick work/concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed |
| 12 | Taking up or down carefully steel water tubing 15mm to 25mm bore complete all as specified and directed. |
| 13 | All as per item ser No 12.00 above but 40 to 50mm bore. |
| 14 | All as per item ser No12.00 above but 80 to 100 mm bore. |
| 15 | Supply and laying Gl pipe medium grade ISI marked including all new fittings in position in trenches/wall/ floor of size 15mm bore complete all as specified and directed. |
| 16 | All as per item ser No.15.00 above but 20mm |
| 17 | All as per item ser No15.00 above but 25mm |
| 18 | All as per item ser No 15.00 above but 40mm |
| 19 | All as per item ser No.15.00 above but 50mm. |
| 20 | All as per item ser No 15.00 above but 80mm |
| 21 | All as per item ser No 15.00 above but 100mm |
| 22 | M&L for cutting existing Gl tubing for alteration or addition of 40mm to 50mm including screwing existing Gl tubing for tapping & making new connection etc complete all as specified & directed. |
| 23 | All as per item ser No 22.00 above but 80mm to 100mm |
| 24 | Supply and fix cast iron air release valves with single air outlets, confirming to (IS-14845) of size 50 mm dia bore PN-1.6 and fixing up in water supply mains duly painted with bitumen black paint complete all as specified and directed. |
| 25 | S&F cast iron Sluice Valve of dia 80 mm ISI marked (PN-1.6) with rising stem confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets including taking out old unserviceable complete all as specified and directed |
| 26 | All as per item ser No 25.00 above but 100mm |
| 27 | All as per item ser No25.00 above but 150mm |
| 28 | M&L for Rubber Gasket Joint (tyton joint) including jointing material for DI/CI pipe of size 150 mm bore dia including taking out old unserviceable joint complete as specified and directed. |
| 29 | Supply and fix in replacement cast iron non return (reflux) valve of 80mm bore with flanged ends in swing type design as per IS 5312 Part-1. PN-1.6 with gun metal sheet complete all as specified and directed. |
| 30 | All as per item ser No 29.00 above but 100mm |
| 31 | S&F rotational moulded polythelene water storage tank (cylindrical vertical with Ea closed top) double layer of capacity 500 Itrs hoisted & fixed in position including taking down old unserviceable water tank complete all as specified and directed |
| 32 | All as per item ser No 31.00 above but 1000 Ltr |
| 33 | All as per item ser No 31.00 above but 2000 Ltr |
| 34 | S&F gun metal gate valve with iron wheel head screwed both ends for iron pipe, ISI marked as per IS: 778 of size 15 mm bore dia including taking out old unserviceable complete all as specified and directed |
| 35 | All as per item ser No 34.00 above but 20mm |
| 36 | All as per item ser No 34.00 above but 25mm |
| 37 | All as per item ser No 34.00 above but 40mm |
| 38 | All as per item ser No 34.00 above but 50mm |
| 39 | S&F in repair mild steel work such as MS Sheet, angle iron, flat iron etc including cutting, welding complete all as specified and directed. |
| 40 | M&L for preparation of new steel or iron surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete al as specified and directed. |
| 41 | Supply and fixing High light intensity empowered color changing & monochromatic LED under water fountain light with polarized light design & intelligent logarithmic control technology of 9 watt with all connections complete all as specified and directed please |
| 42 | M&L for Point wiring with 1.5 Sqmm multistranded copper conductor cable multistranded, FRLSH PVC insulated and unsheathed in and including PVC concealed connduit including cutting chasing for conduits with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Modular fittings including acessories as modular metal flush box 2mm thick surface cover plate with frame, for one light/Fan/Exhaust Fan/bell point complete all as specified and as directed |
| 43 | Taking shutdown dismantling of LT panel complete and S&F in replacement outdoor type cubical panel board suitable for 3 phase, 4 wired, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet of 2 mm thick having modern fabrication process powder coating in approved shade having thickriess not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS 8623/93. The LT Panel shall be front openable The panel should have suitable size of Aluminium bus bar three phase 4 wired system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer MCCB The panel should have the following incoming and outgoing controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engr in-Charge (PCC platform of suitable size for mounting the feeder pillar box is deemed to be included in the quoted rate) CPRI approved manufacturer and to accommodate the following incoming and outgoing controls and suitable size:INCOMING(i) 100 Amps, 35KA 4P EDO type Microprocessor based MCCB with ON/OFF/TRIP indicating lamps with MCB\"s and over current short circuit and earth fault releases - 1 No)(ii) Voltmeter and Ammeter digital type(iii) Phase indicator lamp (LED type) 1 set (set of three) and one indicator lamp for motorON/OFFOUT GOING(i) MCB 63 A, 16 kA 3 pole C Curve type -1 Nos(ii) MCB 20 A 10 kA 3 pole C Curve type-03 Nos(iii DOL Starter 5 HP-01 Nos 240 Volt. 50Hz(iv) Drawing of LT Panel shall be approved by GE. |
| 44 | Supplying and drawing 3 Core 6 Sqmm FRLS PVC insulated copper conductor, single core submersible cable in the existing surface recessed steel/ PVC conduit as required complete all as specified and directed. |
| 45 | Supply only submersible pump set hight efficiency dynamically balanced rotary parts outlet dia of pump not exceeding 50mm having capacity 7.5 HP at 30 Mtr Head with discharge range 640 LPM complete with submersible motor having corrosion free motor internals of suitable capacity, three phase in and including water & weather proof PVC insulated copper conductor multistrand cable 3 care, 1100 volts grade 40 meter length complete all as speified and directed Make KSB/Kirloskar or equivalent as approved by GE. |
| 46 | Material and Labour for earthing complete with Gl earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.50 meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same Gl plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolls and washers. Strip laid in 40mm dia light grade Gi pipe as protection from top of the plate up to test point with following: (a) Gl strip of size 25mm x 4mm (b) Watering pipe Gi light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit (G) Funnel should properly tightned on Gl watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 16 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. |
| 47 | S&F double pole 240 volts isolator of 63 A capacity in the existing MCB DB complete with connections complete all as specified and directed. |
| 48 | M&L for wiring for circuit/submain wiring alongwith earth wire with 2 run 10.0 sqmm and one run of 10.0 sqmm as earth continuty conductor FRLS PVC insulated copper conductor, single core cablein surface/recessed as required.Note :- 2 run of 10 Sqmm cable, one run of 10.0 sqmm and one run of PVC conduit including cutting & chasing shall be measured as one unit. |
| 49 | S&F MCB distribution board single phase and neutral (SPN) 240 volts 8 way double door on surface/recess complete with 200 amp rated bus bar earth bar , din bar connections, powder painted incl earthing etc as required complete all as specified and directed. |
| 50 | M&L for pointwiring as per site requirment with PVC insulated FR LS unsheathed copper conductor cable of size 2.5 sqmm including earth wire of size 1.5 Sqmm in and including concealedPVC conduit including MS bos suitable of modular fittings ,inner and outermodular top sheet top cover,for one 5 pin socket outlet 15 Amps independent all as specified . |
| 51 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connections etc as required. |
| 52 | Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.5meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron earth wire 4.00 mm dia by means of Copper nuts, bolts and washers.GI wire shall be laid in 20 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :-(a)GI wire of 4 mm dia.(b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm diamild steel TMT bars suitable for carrying of pit cover. |
| 53 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten/recess/chases/buried in ground/drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 4.0mm dia galvanised iron wire in and including 20 mm dia Gl pipe (in trenches) and 20 mm dia PVC conduit (In walls) complete all as specified and directed. |
| 54 | Supply and fix Single Phase digitalelectrical energy meter with electronic LCD display suitable for 0-30 Amp, 240 volts, AC 50 Hz of class accuracy 0.5 |
| 55 | Supply, laying and testing cable XPLE insulated armoured heavy duty cable with aluminium stranded conductor,1100 volts grade with standard of size 35 sqmm 3.5 core on wall surface as required. |
| 56 | Providing and fixing 125 Amps 4 pole 16 KA breaking capacity MCCB with thermomagnetic release and thermal spreader in existing DB inclmaking connections as required. |
| 57 | S&F MCB distribution board three pole and neutral (TPN) 415 volts 4 way double door on surface/recess complete with tinner copper bus bar & blanking plate earth bar, din bar connections, powder painted incl earthing etc as required. |
| 58 | Supply and Fixing 63 A rating MCB TPN, rupturing capacity 10 ΚΑ, \"C\" curve, 415V in the existing MCB DB complete with connections, testing and comissioning etc. as required. |
| 59 | Supply and fixing 6 A to 32 A rating rating 240/415 V, 10 KA \"C\" curve miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and comissioning etc as required. |
| 60 | M&L for wiring for circuit/submain wiring alongwith earth wire with 2 run 6.0 sqmm and one run of 6.0 sqmm as earth continuty conductor FRLS PVC insulated copper conductor, single core cablein surface/recessed as required.Note :- 3 run of 6 Sqmm cable and one run of PVC conduit including cutting & chasing shall be measured as one unit. |
| 61 | M&L for Wiring for light/power plug with 2X4 sqmm FRLS insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 62 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connections etc as required. |
| 63 | Supply and fixing 20 A , 240 V, SPN industrial type socket outlet, with two pole and earth, metal enclosed plug topalong with 20 A \"C\" curve, SP, MCB, in sheet metal enclosure on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and comissioning etc as required. |
| 64 | S&F DLP U-PVC trunking system size 105 x 50 mm with all accessories for fittings including flexible cover complete all as specified and directed. |