| Sl. No. | Item Description |
| 1 | Material and labour in repair for earthing complete with GI earthplate 600mm x 600mm x 6.3 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3of MES schedule Part-I and incl 40 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate,reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete all as specified and as directed. |
| 2 | Material and labour in repair for earthing complete with GI earthplate 600mm x 600mm x 6.3 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3of MES schedule Part-I and incl 40 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-1+B500 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate,reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth workcomplete all as specified and as directed. |
| 3 | Material and labour in repair for earthing complete with copper earthplate 900mm x 900mm x 5 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI earth strip 50 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3of MES schedule Part-I and incl 80 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-1+B500 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate,reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth workcomplete all as specified and as directed. |
| 4 | Material and labour in repair for earthing complete with copper earth plate electrod600mm x 600mm x 3 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to copper earth strip 20 x 3mm by means of briazzing made out of copper steel all as shown in electrical plate No. 3of MES schedule Part-I and incl 40 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate,reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete all as specified and as directed. |
| 5 | S&F in repair copper strip of size 20mmx3 mm thickfor earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and as directed by Engineer-in-charge. |
| 6 | S&Fin repair 32x6 mm thick galvanised iron strip for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as specified and as directed by Engineer-in-charge. |
| 7 | S&Fin repair 25 x 4mm thick galvanised iron strip for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc , complete all as specified and as directed by Engineer-in-charge. |
| 8 | Material and labour in repair for galvanised steel wire of size 4mm dia for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc,complete all as specified and as directed. |
| 9 | Excavation in trenches in soft/loosesoil n exc 1.5 metre wide and not exc 1.5 metre deep and getting out including forming bottom surface forlaying LT cable, foundations, GI/CI/DI pipe etc complete all as specified and directed by Engr-in-charge. |
| 10 | Returning filling in includingspreading levelling watering and well ramming in layer not exceeding25 cm thick complete all as specified and directed byEngr-in-charge. |
| 11 | Removing excavated material n.exc 50 m and depositing where directed at alevel n exc 1.5 metre above the starting point complete all as specified and directed by Engr-in-charge.. |
| 12 | Supply and laying dry sand cushioning for UG cable protection in trenches withfine river sand 9 cm before laying cable and 9 cm deep cover after laying the cable complete all as specified and directed by Engr-in-Charge. |
| 13 | M&L for brick protection cover to underground cable with sub-class ‘B’ old size over burnt bricks laid dry and flat across the axis of cable, abutting each other with gaps between adjacent bricks not exceeding 10mm complete all as specified & directed. |
| 14 | M&L for making hole by suitable means for insertion of GI pipe 80 mmbore for passing cable across the road withoutcutting the road complete all as specified& directed. |
| 15 | Material and labour in repair including testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 Sqmm, 3.5 core complete all as specified and directed. |
| 16 | Material and labour in repair including testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 Sqmm, 3.5 core complete all as specified and directed. |
| 17 | Material and labour including testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm, 3.5 core complete all as specified and directed. |
| 18 | Material and labour in repair including testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm, 4 core complete all as specified and directed. |
| 19 | Material and labour in repair including testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 core complete all as specified and directed. |
| 20 | Material and labour in repair including testing XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 2 core complete all as specified and directed. |
| 21 | Material and labour in repair for replacement of galvanised tubing light grade laid in trenches or fixed to pole and / or laid under road in any position with necessary clamp nut and bolt etc of 80mm bore size complete all as specified and as directed. |
| 22 | S&F in repair 50 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid in trenches, road crossing, drain crossing, under floor or fixed to iron structures/poles complete all as specified and directed. |
| 23 | Supplying, installing, commissioning and testingin repair factory made outdoor type LT Kiosk box with canopyof size 600mmx600mmx450mm made out of 3.15mm thick CRCA sheet duely powder coatedwith 4 nos 300 Amps copper busbarand 4 nos Mild steel legs of size 40mmx40mmx5mm of length 600 mmand locking arrangement with one Nos of MCCB of 125 Amp 4 pole 25 KAas incomming includinggroutingin PCC 1:3:6 type C-1complete all as specified and directed. |
| 24 | Taking up or down unserviceable GI tubing of any grade for replacement of distribution lineincluding all fittings such as bend, tee, socket and union etc and shifting to near site as directed and following sizes complete all as specified and directed. |
| 25 | (a) 80 mm bore complete all as specified and directed. |
| 26 | (b) 40/ 50 mm bore complete all as specified and directed. |
| 27 | (c)25/32 mm bore complete all as specified and directed. |
| 28 | (d)20 mm bore complete all as specified and directed. |
| 29 | S&F 3- layer PP-R (Polypropylene random copolymer) pipes 90 mm outer dia ,SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random, jointing complete including laid in trenches/floor at places where directedcomplete all as specified and directed. |
| 30 | S&F 3- layer PP-R (Polypropylene random copolymer) pipes 63 mm outer dia ,SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random, jointing complete including laid in trenches/floor at places where directedcomplete all as specified and directed. |
| 31 | S&F Tubes, \"medium grade\", galvanised, with all fitting; of size 25 mm dia laid in trenches jointing complete including laid in trenches/floor at places where directed complete all as specified and directed. |
| 32 | S&F Tubes, \"medium grade\", galvanised, with all fitting; of size 20 mm dia laid in trenches jointing complete including laid in trenches/floor at places where directed complete all as specified and directed. |
| 33 | S & F in repair PP-R Gate valves(brass insert)complete for outder dia of pipe 63 mm complete all as specified and directed. |
| 34 | S & F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 25 mm complete all as specified and directed. |
| 35 | S & F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm complete all as specified and directed. |
| 36 | S & F in repair ofCPVC pipes SDR 11 & PlainCPVC SDR 11 fittings of 25 mm outer dia complete laid on wall or laid in trenches complete all asspecified and directed. |
| 37 | S & F in repair 150 mm bore cast iron flanged & drilled both ends sluice valve, (ISI marked) long body type, conforming to IS 14846-2000; Class PN-1.6 with iron wheel head & brass spindle including all jointing materials and mild steel nuts, bolts, washers, rubber / fibre board gaskets etcand testingcomplete all as specified & directed. |
| 38 | S & F in repair 100 mm bore cast iron flanged & drilled both ends sluice valve, (ISI marked) long body type, conforming to IS 14846-2000; Class PN-1.6 with iron wheel head & brass spindle including all jointing materials and mild steel nuts, bolts, washers, rubber / fibre board gaskets etcand testingcomplete all as specified & directed. |
| 39 | S & F in repair 80 mm bore cast iron flanged & drilled both ends sluice valve, (ISI marked) long body type, conforming to IS 14846-2000; Class PN-1.6 with iron wheel head & brass spindle including all jointing materials and mild steel nuts, bolts, washers, rubber / fibre board gaskets etcand testingcomplete all as specified & directed. |
| 40 | Supply onlyAltoch GP/Altoch CH in granualer form in sealed 45 Kg drum completeall as specified and directed. |
| 41 | Supply onlybleaching powder in sealed 25 Kg packet/bag completeall as specified and directed. |
| 42 | M&L for construction of brick masonry valve pit of size 120x120x120cm (internal dimension) one brick thick wall built in CM (1:4) on 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4)both externally andinternally, external plaster shall be up to 25cm below GL, providing valve pit cover made of 1.60mm thick MS sheet/plate, including provision of hinges, handle and locking arrangement including40X40X3mm angle iron frame fixed on top of valve pit by means of MS hold fast 40x5mm and 150mm long, embedded in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) and wall of sub class \"B\" bricks, including two coats of anti-corrosive paint over a coat of red oxide zincChrome primer and necessary earth work in soft/loose soilcomplete all as specified and directed. |
| 43 | M & L for taking out the defective / burnt out compressor from Split type air conditioner/window type AC of 1.5 ton capacity from its position and providing new compressor Rotary / Reciprocating of approved make best suitable for the unit, cleaning the refrigeration system thoroughly with CTC, leak testing, vaccumisation, charging with new refrigerant gas suitable for the unit testing for its effective functioning, connecting up all electrical connections and finally testing and commissioning including cost of cutting, brazing , sealing the refrigeration tubing, replacement of stainer, CTC, refrigerant gas, CO2, etc. as required for the job complete all as specified and directed. Notes :- Quoted rate is deemed to be inclusive for cutting, brazing, sealing the refrigeration tubing, replacement of stainer, CTC, refrigernat gas including transportation charges from site to workshop and back. |
| 44 | All as per item No. 43 here in before but for 2.0 Ton capacity floor mounted / tower model Split/window type AC Conditioner complete all as specified and directed. |
| 45 | S & F in repairfor compressor suitable for refrigerator of 400 litres capacity including charging of refrigerant gas and testing including taking out old defective compressor complete all as specified and directed. |
| 46 | S & F in repair for compressor suitable for water cooler of 150 litres capacity including charging of refrigerant gas and testing including taking out old defective compressor complete all as specified and directed. |
| 47 | S & F in repair for compressor suitable for Deep freezer of any capacity including charging of refrigerant gas and testing including taking out old defective compressor complete all as specified and directed. |
| 48 | Supply and charging of refrigerant gas (R-410a) suitable for window / split air conditioners / water collers / refrigerators complete all as specified and directed. |
| 49 | M & L for leak testing with N2 gas of entire refrigeration system, rectification of leaks by welding / brazing and pressure testing as per the standards and holding the pressure for 24 Hrs and observe for any pressure drop in the system including evacuation with vaccum machine complete all as specified and directed. |
| 50 | S & F in repair blower fan motor for hot air upto 2.0 Ton capacity Split air conditioner/window Air conditioner with new fan motor double shaft type suitable for air conditioners 800 to 1250 RPM including testing complete all as specified and directed. |
| 51 | S & F in repair blower fan motor for water cooler upto 150 Ltr capacity complete all as specified and directed. |
| 52 | S & F in repair blower fan blade for hot air / cool air suitable for split type/window type air conditioner upto 2.0 Ton capacity, balancing for smooth rotation in the casing and testing complete all as specified and directed. |
| 53 | S & F in repair unserviceable blower fan blade for water cooler upto 150 Ltr capacity balancing for smooth rotation in the casing and testing complete all as specified and directed. |
| 54 | S & F in repairrunning capacitors with new capacitors 45 mfd rating complete all as specified and directed. |
| 55 | S & F in repair running capacitors with new capacitors 50 mfd ratingcomplete all as specified and directed. |
| 56 | S & F in repair running capacitors with new capacitors 25 mfd ratingcomplete all as specified and directed. |
| 57 | S & F in repairRelay suitable for Split AC upto 2.0 Ton capacity complete all as specified and directed. |
| 58 | M & L for servicing of Air conditioners of any make and capacity with electrical blower and motor, cleaning with castic soda and soap water to all the parts including evaporator, condenser, grills, etc and checking of all the electrical connections, etc complete all as specified and directed. |
| 59 | M & L for servicing of water coolers, Refrigerators and deep freezers of any make and capacity with electrical blower and motor, cleaning with castic soda and soap water to all the parts including evaporator, condenser, etc and checking of all the electrical connections, etc complete all as specified and directed. |
| 60 | M & L for rewinding of blower / fan motor of any capacity Split type/window type AC including dismantling the motor completely, removing old winding, cleaning the starter, rewinding the motor with appropriate gauge super enamelled copper conductor and insulating materials and fixing back the motor in original position including testingcomplete all as specified and directed. |
| 61 | M & L for rewinding of blower / fan motor of any capacity Deep freezer/Refrigeratorincluding dismantling the motor completely, removing old winding, cleaning the starter, rewinding the motor with appropriate gauge super enamelled copper conductor and insulating materials and fixing back the motor in original position including testing complete all as specified and directed. |
| 62 | M & L for Repairs toprinted circuit board of Split AC / Window AC / water cooler / refrigerator of 230 Volts single phase any capacity including testingcomplete all as specified and directed. |
| 63 | S & F in repairElectronic Printed Circuit board for outdoor unit of inverter type Split AC of 1.5/2.0 Ton capacityincluding testingcomplete all as specified and directed. |
| 64 | S & F in repair Electronic Printed Circuit board for indoor unit of inverter type Split AC of 1.5/2.0 Ton capacityincluding testingcomplete all as specified and directed. |
| 65 | S & F in repair copper tubing 24 SWG of size5/8\" along with tubular insulation suitable for Split ACincluding testingcomplete all as specified and directed. |
| 66 | S & F in repair copper tubing 24 SWG of size1/2\" along with tubular insulation suitable for Split ACincluding testingcomplete all as specified and directed. |
| 67 | S & F in repair copper tubing 24 SWG of size1/4\" along with tubular insulation suitable for Split ACincluding testingcomplete all as specified and directed. |
| 68 | S & F in repair PVC drain pipe of 20mm bore complete all as specified and directed by Engineer-in-Charge. |
| 69 | S & F in repair Split AC Valves made of high grade free cutting brass and copper for pipe of size 1/2\", 1/4\", 3/8\" and 5/8\"including testingcomplete all as specified and directed. |
| 70 | S & F in repair sheet metal enclosure with single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed. |
| 71 | S & F in repair lift/push cock chromium plated brass of 15mm size suitable for water cooler of capacity 40/80 Litresincluding testingcomplete all as specified and directed. |
| 72 | S & F in repair thermal insulation for indoor to outdoor copper pipe suitable for split type AC of any capacityincluding testing complete all as specified and directed. |
| 73 | S & F in repair Thermostat suitable for water cooler of capacity upto 150 Litreincluding testingcomplete all as specified and directed. |
| 74 | S & F in repair Overload protector suitable for water cooler of any capacityincluding testingcomplete all as specified and directed. |
| 75 | Supply and fixing in replacement of PVC insulated and round sheathed flexible muti stranded copper conductor of size 4 Sqmm 3 core, 1100 volts complete all as specified and directed. |
| 76 | S & F in repair swing motor suitable for split / tower AC of any capacity complete all as specified and directed. |
| 77 | S & F in repair voltage stabiliser for automatic operation, single phase naturally air cooled, copper wounded as per IS 8448-1989 with digital display, wall mounted, indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilsed at 230 Volts with accuracy of + 2.5% and of capacity 4 KVA complete all as specified and directed. |
| 78 | S&F in repair thermostat and suitable lamp indicators for 25 litres capacity geyser suitable for 230 volts, AC , 50 Hz supply and adjustable temperature control from 40 to 70 degree centrigrade including rubber washers and all necessary electrical connection complete all as specified and directed. |
| 79 | S&F in repair thermostat and suitable lamp indicators for 50 litres capacity geyser suitable for 230 volts, AC , 50 Hz supply and adjustable temperature control from 40 to 70 degree centrigrade including rubber washers and all necessary electrical connection complete all as specified and directed. |
| 80 | S&F in repair heating elements 2000 wattsas per sample suitable for geyser of 50 litres capacityincluding testingcomplete all as specified and directed. |
| 81 | S&F in repair heating elements 1500 wattsas per sample suitable for geyser of 25 litres capacityincluding testingcomplete all as specified and directed. |
| 82 | S&F in repair hot and cold pipe 15mm bore 450mm long with brass sockets at both endincluding washersincluding testing complete all as specified and directed. |
| 83 | S&F in repair apparatus plate assembly ( syphon type) of approved quality suitable for geyser of 50 litres capacity ( horizontal or vertical type) including testingcomplete all as specified and directed. |
| 84 | S&F in repair apparatus plate assembly ( syphon type) of approved quality suitable for geyser of 25 litres capacity ( horizontal or vertical type)including testingcomplete all as specified and directed. |
| 85 | S&F in repair inner shell made out of copper sheet of approved quality suitable for geyser of 50 litres capacity ( horizontal or vertical type)including testingcomplete all as specified and directed. |
| 86 | S&F in repair inner shell made out of copper sheet of approved quality suitable for geyser of 25 litres capacity ( horizontal or vertical type)including testingcomplete all as specified and directed. |
| 87 | S&F in repair for wall fastener of size 150mm long, 8mm dia with double washers properely grouted on wall and making good disturbed surfaces in cement mortar 1:4 for fixing of geyserincluding testingcomplete all as specified and directed. |
| 88 | S&F in repair damaged top / bottom plates ofgeyser 25/50 litres capacityincluding testingcomplete all as specified and directed. |
| 89 | M & L for providing Point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including PVCconcealed conduit of adequate size but not less than 20mm in dia and 1.2mm thick with all fittings and accessories including modular surface box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc. complete with all fittings and accessories fixed to wall/ ceiling for one light/ fan point controlled by one one way modular switches including one run 1.5 sqmm (nominal area) PVC insulated FRLSH unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly including taking down old unsv complete all as specified & directed |
| 90 | (a)One light/Fan point controlled by one one/way switch complete all as specified and directed. |
| 91 | (b) One light point controlled by two2 way switches complete all as specified and directed. |
| 92 | (c)One bell/buzzer point controlled by one push button on the same board with other switches or independentwith cables 1.5 sq.mm size complete all as specified and directed. |
| 93 | (d) One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed. |
| 94 | (e) One 3 pin 5 Amps socket outlet on independent board with cable of 2.5 sqmm size complete all as specified and directed. |
| 95 | All as per item No 89 above but here in before wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed. |
| 96 | M&L in repair for sub main wiring using two single core 6 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLSH) ISI marked drawing in and including 25mm dia rigid non metalic PVC Concealed conduit & accessories like bends, tee, etc fixed and connecting to earth dolly and including one single core6 Sqmm earth wire, PVC insulated & unsheathed complete. Note : 2 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length. Rate quoted by contractor is demed to be included to match the disturbed surfaces with exisitng wall and no extra payment shall be made on this account complete all as specified and directed. |
| 97 | M&L in repair for sub main wiring using two single core 4 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLSH) ISI marked drawing in and including 25mm dia rigid non metalic PVC Concealed conduit & accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including one single core4 Sqmm earth wire, PVC insulated & unsheathed complete. Note : 2 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length. Rate quoted by contractor is demed to be included to match the disturbed surfaces with exisitng wall and no extra payment shall be made on this account. |
| 98 | M&L in repair for sub main wiring using two single core 2.5 Sqmm FRLSH PVC insulated and unsheathed cable with copper conductor 1100 volts grade (FRLSH) ISI marked drawing in and including 20 mm dia rigid non metalic PVC Concealed conduit & accessories like bends, tee, etc fixed on recess of wall and ceiling and connecting to earth dolly and including one single core2.5 Sqmm earth wire, PVC insulated & unsheathed complete. Note : 2 runs of main wire, 1 run of earth wire, 1 run of conduit with accessories shall be measured as one length. Rate quoted by contractor is demed to be included to match the disturbed surfaces with exisitng wall and no extra payment shall be made on this account. |
| 99 | Supply and fixing in replacementLED Tubelight lights fitting 1x 18W / 20W (White/warm white/multicolouredand quantity as decided and directed by Engineer in Charge), 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 100 | Supply and fixing in replacementLED tubelight fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 101 | Supply and fixing in replacementLED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare freelightwhite/warm white/multi coloured (quantity as directed and decided by Engineer in Charge) complete with driver, holders & LED lamp suitable for false ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 102 | Supply and fixing in replacementround shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free white/Multicoloured light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 103 | Supply and fixing in replacementround shape 12 watt 220 volts AC recessed mounted LED downlighter with COB technologytype with high efficiency PMMA diffuser soft glare free White/warm white/multicoloured light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 104 | Supply and fixing in replacementpost top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 105 | Supply and fixing in replacementgarden lightLED type 08 watt 230 watt volts AC outdoor type with decorativefor 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, pole of requiredsize and height, PCC foundation and required qty of nuts, bolts, washers and junction boxes for conenction of electical cable etc complete all as specified and directed. |
| 106 | Supply and fixing in replacement of decorative LED AC strip light 60 LED/Mtr, CCT - 3000K, IP-65, 5 mtr length (White/Warm white/multi coloured as decided and directed by Engineer in Charge)water proof with jointer and adaptor suitable for 180 V to 280 Volt complete all as specified and directed. |
| 107 | Supply and fixing in replacement of decorative LED AC tricolour rope light having 560 lumen watt output per meter and 120 LEDs per meter, IP-65, 30 mtr length (White/Warm white/multi coloured as decided and directed by Engineer in Charge)water proof with jointer and adaptor (Quantity as directed by Engineer in charge) suitable for 180 V to 280 Volt complete all as specified and directed. |
| 108 | Supply and fixing in replacement of compact LED floodlight with system luminous efficacy of 110lm/w, protected to IP66, with front toughened glass,with discrete high lumen LED (White/Warm white/multi coloured as decided and directed by Engineer in Charge)water proof complete of 50Wsuitable for 180 V to 280 Volt complete all as specified and directed. |
| 109 | Supply and fixing in replacement ofcompact LED floodlight with system luminous efficacy of 110lm/w, protected to IP66, with front toughened glass,with discrete high lumen LED (White/Warm white/multi coloured as decided and directed by Engineer in Charge)water proof complete of 70Wsuitable for 180 V to 280 Volt complete all as specified and directed. |
| 110 | Supply and fixing in replacement ofcompact LED floodlight with system luminous efficacy of 110lm/w, protected to IP66, with front toughened glass,with discrete high lumen LED (White/Warm white/multi coloured as decided and directed by Engineer in Charge)water proof complete of 100Wsuitable for 180 V to 280 Volt complete all as specified and directed. |
| 111 | Supply and fixing in replacement ofcompact LED floodlight with system luminous efficacy of 110lm/w, protected to IP66, with front toughened glass,with discrete high lumen LED (White/Warm white/multi coloured as decided and directed by Engineer in Charge)water proof complete of 120Wsuitable for 180 V to 280 Volt complete all as specified and directed. |
| 112 | S&F in replacement Call bell, Ding Dong AC. 230 volts,single pole complete all as specified and directed. |
| 113 | S&F in replacement Modular switch one way 5/6 Amp,1 module, 240 Volts complete all as specified and directed. |
| 114 | S&F in replacement Modular switchtwo way 5/6 Amp,1 module, 240 Volts complete all as specified and directed. |
| 115 | S&F in replacement Modular Bell push6 Amp, 1 module, 240 Volts complete all as specified and directed. |
| 116 | S&F in replacement Modular socket2/3 pin, 6 Amps, 2 module240 Volts complete all as specified and directed. |
| 117 | S&F in replacement Modular switchone way, 16 Amp, 1 module, 240 Volts complete all as specified and directed. |
| 118 | S&F in replacement Modular socket 16A, 6 pin, 3 module 240 volts complete all as specified and directed. |
| 119 | S&F in replacement ceiling rose surface bakelite two to three terminal 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed. |
| 120 | Supply and fixing in replacement fan step regulator, 120W, 2 Module A/C 240 Volts complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail